• Title/Summary/Keyword: bulk decay

Search Result 56, Processing Time 0.021 seconds

Prediction of residual chlorine using two-component second-order decay model in water distribution network (이변량 감소모델을 적용한 배급수관망에서의 잔류염소농도 예측 및 이의 활용)

  • Kim, Young Hyo;Kweon, Ji Hyang;Kim, Doo Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.287-297
    • /
    • 2014
  • It is important to predict chlorine decay with different water purification processes and distribution pipeline materials, especially because chlorine decay is in direct relationship with the stability of water quality. The degree of chlorine decay may affect the water quality at the end of the pipeline: it may produce disinfection by-products or cause unpleasant odor and taste. Sand filtrate and dual media filtrate were used as influents in this study, and cast iron (CI), polyvinyl chloride (PVC), and stainless steel (SS) were used as pipeline materials. The results were analyzed via chlorine decay models by comparing the experimental and model parameters. The models were then used to estimate rechlorination time and chlorine decay time. The results indicated that water quality (e.g. organic matter and alkalinity) and pipeline materials were important factors influencing bulk decay and sand filtrate exhibited greater chlorine decay than dual media filtrate. The two-component second-order model was more applicable than the first decay model, and it enabled the estimation of chlorine decay time. These results are expected to provide the basis for modeling chlorine decay of different water purification processes and pipeline materials.

First-Principles Study on Thermodynamic Stability of UO2 with He Gas Incorporation via Alpha-Decay

  • Kwon, Choa;Lee, Kwanpyung;Han, Byungchan
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.368-371
    • /
    • 2019
  • Using first principles calculations we investigated the thermomechanical stability of spent nuclear fuels (SNF), especially how mechanical properties of $UO_2$, such as, bulk, shear and Young's moduli and Poisson's ratio vary through alpha-decay of U into Th with generation of He gas. Our results indicate that substitution of U by Th through alpha decay ($U_{1-x}Th_xO_2$) does not significantly affect the stability of the grain in a fuel matrix. In addition, we studied the transport properties of He in and boundaries of the $U_{1-x}Th_xO_2$ grain. Helium preferentially resides at the grain boundaries through diffusion. Our study can contribute to substantial reduction of environmentally risk and enhancement of our sustainability by safe control of radioactive materials.

Space Charge Measurement as a Diagnostic Tool to Monitor Ageing in Polymeric Materials

  • Chen, George
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.235-239
    • /
    • 2006
  • Charge dynamics in polymeric materials after aged under ac electric field using the pulsed electroacoustic (PEA) technique is reported. The emphasis is placed on charge decay. The charge dynamics of the ac aged additive free low density polyethylene (LDPE) samples under dc bias differ from the sample without ac ageing, indicating changes brought in by ac ageing. It is believed that a slow decay rate of charge in the ac aged sample is related to the formation of deep traps in the material. However, chemical analysis by infrared spectroscope (FTIR) and Raman microscope reveals no significant chemical changes taken place in the bulk of the material after ac ageing. Further experiments on irradiated LDPE have revealed a similar behaviour, i.e. the charge decay is slower in irradiated samples than that of fresh sample. The findings presented clearly indicate that space charge measurement can be used as a diagnostic tool to monitor ageing in polymeric materials.

Computing the Dosage and Analysing the Effect of Optimal Rechlorination for Adequate Residual Chlorine in Water Distribution System (배.급수관망의 잔류염소 확보를 위한 적정 재염소 주입량 산정 및 효과분석)

  • Kim, Do-Hwan;Lee, Doo-Jin;Kim, Kyoung-Pil;Bae, Chul-Ho;Joo, Hye-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.916-927
    • /
    • 2010
  • In general water treatment process, the disinfection process by chlorine is used to prevent water borne disease and microbial regrowth in water distribution system. Because chlorines were reacted with organic matter, carcinogens such as disinfection by-products (DBPs) were produced in drinking water. Therefore, a suitable injection of chlorine is need to decrease DBPs. Rechlorination in water pipelines or reservoirs are recently increased to secure the residual chlorine in the end of water pipelines. EPANET 2.0 developed by the U.S. Environmental Protection Agency (EPA) is used to compute the optimal chlorine injection in water treatment plant and to predict the dosage of rechlorination into water distribution system. The bulk decay constant ($k_{bulk}$) was drawn by bottle test and the wall decay constant ($k_{wall}$) was derived from using systermatic analysis method for water quality modeling in target region. In order to predict water quality based on hydraulic analysis model, residual chlorine concentration was forecasted in water distribution system. The formation of DBPs such as trihalomethanes (THMs) was verified with chlorine dosage in lab-scale test. The bulk decay constant ($k_{bulk}$) was rapidly decreased with increasing temperature in the early time. In the case of 25 degrees celsius, the bulk decay constant ($k_{bulk}$) decreased over half after 25 hours later. In this study, there were able to calculate about optimal rechlorine dosage and select on profitable sites in the network map.

Rechlorination for residual chlorine concentration equalization in distribution system (급배수시스템에서 잔류염소 농도 균등화를 위한 재염소 처리)

  • Kim, Jinkeun;Han, Ji-An
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.91-101
    • /
    • 2014
  • Three water treatment plants(WTPs) in Jeju island whose source water have different characteristics from those of the mainland of Korea were investigated. Coefficients of bulk water decay($k_b$) of free chlorine at $5^{\circ}C$ for ES, GJ, NW WTPs were $-0.003hr^{-1}$, $-0.002hr^{-1}$ and $-0.001hr^{-1}$ respectively based on bottle tests. To simulate the free chlorine variations in the distribution system using EPANET, ES WTP was chosen. Free chlorine concentrations of several sites were less than the drinking water quality standards(i.e., 0.1 mg/L); E5(0.03 mg/L), E6(0.02 mg/L), W21(0.02 mg/L) and W25(0.03 mg/L). To maintain more than 0.1 mg/L of free chlorine in the distribution system, at least 1.9 mg/L of chlorine was needed at the WTP, which suggested rechlorination was needed to supply palatable tap water to customers. Two sites, one that diverged into E5 and E6 in the east-line and another located before E21 in the west-line were selected for the appropriate rechlorination locations. The recommended rechlorination dosages were 0.42 mg/L for the east and 0.27 mg/L for the west. The simulated results indicated that the free chlorine could be reduced to 0.4 mg/L at the WTP with rechlorination, and taps with excessive free chlorine could be more stabilized(i.e., 0.1~0.4 mg/L).

Modeling Residual Chlorine and THMs in Water Distribution System (배급수계통에서 잔류염소 및 THMs 분포 예측에 관한 연구)

  • Ahn, Jae-Chan;Lee, Su-Won;Rho, Bang-Sik;Choi, Young-Jun;Choi, Jae-Ho;Kim, Hyo-Il;Park, Tae-Jun;Park, Chang-Min;Park, Hyeon;Koo, Ja-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.706-714
    • /
    • 2007
  • This study suggested a method for prediction of residual chlorine and THMs in water distribution system by measurement of residual chlorine, THMs, and other parameters, estimation of chlorine decay coefficients and THM formation coefficients, and simulation of water qualities using pipe network analysis. Bulk decay coefficients of parallel first-order were obtained by bottle tests, and pipe wall decay coefficients of first-order were estimated through evaluation of 5 models, which showed the lowest values of 0.03 for MAE(mean absolute error) and 0.037 MAE in comparison with the observed in field. And bottle tests were conducted to model first-order reaction of THM formation by nonlinear least square regression and the resultant coefficients were compared with the observed in field. As a result, the coefficients of determination$(R^2)$ for the observed and the predicted values were 0.98 in September and 0.82 in November, and the formation of THMs was predicted by modeling.

Prediction of Chlorine Residual in Water Distribution System (상수관망내 잔류염소농도 분포 예측)

  • Joo, Dae-Sung;Park, No-Suk;Park, Heek-Yung;Oh, Jung-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.118-124
    • /
    • 1998
  • To use chlorine residual as an surrogate parameter of the water quality change during the transportation in the water distribution system(WDS), the correct prediction model of chlorine residual must be established in advance. This paper shows the procedure and the result of applying the water quality model to the field WDS. To begin with, hydraulic model was calibrated and verified using fluoride as an tracer. And chlorine residual was predicted through simulation of water quality model. This predicted value was compared with the observed value. With adjusting the bulk decay coefficient(kb) and the wall decay coefficient(kw) according to the pipewall environment, the predicted chlorine residual can represent the observed value relatively well.

  • PDF

Decolorization of Rhodamine B Using UV/$TiO_2$ System (UV/$TiO_2$ 시스템을 이용한 Rhodamine B의 색도 제거)

  • 박영식;나영수;안갑환
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.59-64
    • /
    • 2002
  • The photocatalytic decolorization of the Rhodamine B (RhB) was studied using a UV/TiO$_2$ reactor. Yakuri titanium dioxide(anatase) was used as the suspended photocatalyst and proved to be effective for decolorization irradiated with UV light (254 mm). The photocatalyzed dioxide concentrations, light intensity and air flow rates. In 0.01 mM RhB, color could be completely photodegraded after 3 hours. Absorption spectrum of an aqueous solution containing RhB showed a continued diminution of the RhB concentration in the solution bulk : concomitantly, no new absorption peaks appeared. This confirmed the decolorization of RhB, i.e., the break up of the chromopore. The optimum loaded titanium dioxide for the decolorization was 0.75 g/(equation omitted). The light intensity showed exponential decay with distance. The decay of light intensity of RhB solution showed different tendency from TiO$_2$. These results suggested that the photocatalytic decolorization of dyes may be available method for decolorizing in wastewater.

The decay phenomenon of II-VI compound semiconductors (II-VI 화합반도체소자의 열화현상)

  • Young Kwon Sung
    • 전기의세계
    • /
    • v.17 no.2
    • /
    • pp.16-26
    • /
    • 1968
  • Cds is possible to add excess donors and to compensate partially using other group metals as acceptors. The impurities can ble incorporated either during crysta growth or by diffusion into a bulkcrystal. The addition of rimpurities leads also to the production of vacancies in a manner depending on the atmosphere surrounding the crystal during growth, during the diffusion process or using bulk. Cds of the mentioned above affects spectral sensitivity, speed of response, the variation on photocurrent, electron life time, and decay of photoconductivity with temperature and with intensity of illumination. In the work to be deseribed, these properties have been studied between liquid nitrogen and room temperature. In addition, the electron trap distribution has been correlated with speed of response, variation of photocurrent with temperature in various atmosphere. Four major trapping levels have been observed, and their identification with impurity and vacancy levels is discussed. And also the effects of lattice imperfections on the photoconductive properties CdS were investigated in detail.

  • PDF

An Experimental Consideration on the Decay of Surface Potential from Corona Charged Polysulfone Films (코로나기전된 폴리스로푼의 표면전위감쇠에 관한 실질적 고찰)

  • 이덕철;한상옥;서영일;김필성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.1
    • /
    • pp.21-27
    • /
    • 1984
  • Both of the isother mally and thermally stimulated surface potential decay characteristics(SPDC) have been investigated not only in corona charged polysulfone(PSF) which is one of heat resistant polymer, but also in corona charged polyethyleneterephthalate(PET) and polyfluoroethylene propylene(Teflon FEP) under the same experimental condition. PSF and PET shows similar SPDC in the high teperature region. Also the effect of polarity on SPDC observed from PSF and Teflon FEP shows almost the same phenomenon. From these results, we suggest that the mechanism on SPDC of PSF could be explained as the bulk conductivity from the characteristic analysis concerning PET and electron affivity from characteristic analysis concerning Teflon FEP.

  • PDF