• Title/Summary/Keyword: building rooftop

Search Result 128, Processing Time 0.032 seconds

A Study on Trend of Tensile Properties with Ratio of Water Mixture under Low and High Temperature Environment in Hydroponic Polyurethane Waterproofing Materials (수경화성 폴리우레탄 도막재의 물 혼합비에 따른 저온 및 고온 환경에서의 인장성능 변화 추이 연구)

  • Kim, Dong-Bum;An, Hyun-Ho;Kim, Sun-Do;Park, Wan-Goo;Park, Jin Sang;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.211-212
    • /
    • 2016
  • Due to a lack of objective and adequate study on the physical effects on hydroponic polyurethane waterproofing material water mixture ratio, construction site workers are having to rely on their hands-on experience to determine a mixture ratio, resulting in difficulty of maintaining quality management. Particularly in cases of rooftop exposed type hydroponic polyurethane materials, the varying temperature conditions make it further difficult for quality management control. in this regard, this study conducts tensile strength testing and compares the tensility change rates hydroponic polyurethane waterproofing materials with various water mixture ratios ranging from 0%~50% and exposed to alternating temperature change between -20℃ to 60℃ in the span of 1 hour after curing for 14 days.

  • PDF

Research on Separation Behavior Joint of Develop and Application in Sheet-Membrane Composite Waterproofing (시트-도막을 이용한 분리거동형 복합방수공법 개발 및 적용에 관한 연구)

  • Heo, Neung-Hoe;Kim, Dong-Bum;Oh, Je-Gon;Go, Gun-Woong;Go, Jang-Ryeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.165-166
    • /
    • 2014
  • The Composite waterproofing began to rise gradually 2000s in domestic. However, the sheet-membrane composite waterproofing method also acts as an abutment vulnerability that was a problem in a single method, and had the problem of damage to the formation of leakage paths. The existing non-overlap method, through vigorous research abutting sheet shall or could be developed to improve the seal performance of this method with the I-type joint coating material. Nevertheless, it has an integral top coat paint membrane and a sheet abutment limitation, damage to the upper membrane is damaged junction coating membranes has been generated. In this study, a method that has a layer of insulation on the joint bond breaker concept development, and to determine the physical properties with insulated joints to determine the breaking off of the upper joint is damaged coating membrane and tensile performance.

  • PDF

A Experimental Study on the Complex Waterproofing Method of Exposure using PE Textiles of Mesh type and Highly Viscous Urethane (망사형 PE직물과 고점도 우레탄을 이용한 복층형 노출 방수공법에 관한연구)

  • Shao, Xu-Dong;Song, Je-Young;Kim, Young-Suk;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.127-130
    • /
    • 2011
  • The duplex waterproofing construction method has been investigated to improve various problems (how to fix the sheet, breaking, air/water pocket, and cracks caused by different materials) of the existing rooftop exposed waterproofing construction method. By using fiber sheet, Net PE fabric, and thixotropy urethane with high viscosity, the waterproofing construction method is to glue the ground and waterproof course by circular dot. The method is also to construct the waterproof course with high hardness by using waterproof membrane coatings in upper hybrid system. By gluing the ground and the waterproof course by circular dot, the study is expected to be useful to minimize the simultaneous breaking in the waterproof course as tensile stress is buffer in case of the ground crackling. Also, since the waterproofing construction method is good at moving and emitting vapor from the ground, it is considered to be effective to minimize any damages caused by air/water pocket and get loose of the waterproof course.

  • PDF

A Study on the Four-Season Cooling Performance by Color of Water Proofing Membrane Materials Considering the View of Area (지역의 경관을 고려한 도막방수재의 색채별 사계절 차열 및 축열 성능에 관한 연구)

  • Ko, Jin-Soo;Kim, Byung-Yun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.2
    • /
    • pp.9-16
    • /
    • 2015
  • This study comparatively analyzed thermal characteristics of the green color, which is currently used the most, and other various colors of a rooftop urethane water proofing sheet. This study also analyzed the cooling performance by color of the water proofing sheet that fused cooling paints, and presented the effective water proofing sheet color for building energy savings. The experimental results are as follows: (1) The value of L (brightness) diminished, and brilliance also became lower from the white color to the black color, and thus, it was confirmed that relatively more heat was absorbed. In a and b chromaticity, which is the color attribute that ignores brightness, no special relationship was identified. (2) Considering that the cooling performance effect is bigger in summer than winter, due to heat reflection, the white water proofing sheet is more effective in building energy savings than the green water proofing sheet that is currently used the most. (3) The water proofing sheet's color has an impact more on cooling performance than the color of the background side of a structure on which water proofing sheet is installed. The experiment object of gray, of which background side is similar to cement mortar, was lower by $5.7^{\circ}C$ than the white background side.

Effect of Intercropping Ratio on the Cherry Tomato with Basil on the Growth, Physiological, and Productivity Parameters on the Rooftop in Urban Agriculture (옥상 도시농업에서 방울토마토(Lycopersicon esculentum)와 바질(Ocimum basilicum)간의 공영식재가 생육, 생리, 생산성에 미치는 영향)

  • Ju, Jin-Hee;Song, Hee-Yeon;Oh, Deuk-Kyun;Park, Sun-Yeong;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.30 no.9
    • /
    • pp.709-717
    • /
    • 2021
  • This study evaluated the growth, physiological responses and productivity based on the intercropping ratio of cherry tomato (Lycopersicon esculentum L.) with basil (Ocimum basilicum L.). on the rooftops to determine out the efficient ratio in urban agriculture. From April to September 2019, an experiment was conducted on the rooftop of Konkuk University Glocal Campus. Cherry tomato and basil were selected as companion plants for eco-friendly urban agriculture on the rooftops. Each plot was created with a width of 100 cm, length of 100 cm, and height of 25 cm. After installing drainage and waterproof layers from bottom to top, substrate was laid out with a height of 20 cm. Intercropping ratio was consisted of a single tomato plant (TC), 2:1 tomato to basil (T2B1), 1:1 tomato to basil (T1B1), 1:2 tomato to basil 2 (T1B2), and a single basil plant (BC), were conducted using a randomized complete plot design with five treatments and three replication (a total 15 plots). Measurements were divided into growth, physiological responses, and productivity parameters, and detailed items were investigated and analyzed by classifying them into plant height, leaf length, leaf width, number of leaves, root length, root collar caliper, chlorophyll contents, fresh weight, dry weight, number of fruit, fruit caliper, fruit weight, and sugar content. Comparative analyses of cherry tomato with basil plants by intercropping ratio, growth, physiological, and productivity responses are determined to be efficient when the ratio of cherry tomato to basil ratio is 2:1 or 1:1.

Wind-induced response of structurally coupled twin tall buildings

  • Lim, Juntack;Bienkiewicz, Bogusz
    • Wind and Structures
    • /
    • v.10 no.4
    • /
    • pp.383-398
    • /
    • 2007
  • The paper describes a study of the effects of structural coupling on the wind-induced response of twin tall buildings connected by a skybridge. Development of a dual high-frequency force balance used in wind tunnel investigation and background information on the methodology employed in analysis are presented. Comparisons of the wind-induced building response (rooftop acceleration) of structurally coupled and uncoupled twin buildings are provided and the influence of structural coupling is assessed. It is found that the adverse aerodynamic interference effects caused by close proximity of the buildings can be significantly reduced by the coupling. Neglecting of such interactions may lead to excessively conservative estimates of the wind-induced response of the buildings. The presented findings suggest that structural coupling should be included in wind-resistant design of twin tall buildings.

Nocturnal Radiant Cooling by a Plate Viewing the Sky (야간 하늘에 노출된 평판의 복사냉각효과)

  • Byun, Ki-Hong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1300-1305
    • /
    • 2004
  • The purpose of this experiment is to study the radiant cooling effects by a plate directly viewing the nighttime sky. The measurements are performed at a rooftop of the Engineering building at the Dongguk University in Seoul during the month of August in 2004. The radiant cooling effects are compared using three different types of plate surfaces such as galvanized Iron, black painted, and aluminum film coated galvanized iron plate. Among these plates, the black painted surface show the lowest temperature that is lower than its ambient temperature. The maximum radiant cooling temperature difference, that is ambient temperature minus plate temperature, observed is about 5K..

  • PDF

The Propagation Characteristics using Ray tracing in Urban area (전파추적기법을 이용한 마이크로셀 도심지 환경에서의 전파특성에 관한 연구)

  • 김희중;김관홍박병성박한규
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.177-180
    • /
    • 1998
  • In high frequency environment such as microcell, it is requried to adopt a new method different from the empirical channel modeling applied in macrocell. In this thesis, measurement for residential area in Sinrimdong and the result of the simulation are compared and analyzed. Simulation technique utilizes 3D ray launching method to consider some factors which were not included in the ray tracing method. Propagation environment in the urban area shows the typical channel characterisitics of the propagation environment. Using 3D ray launching method, pathloss of the wave and delay characteristics of the signal with respect to the height of the transmitter is researched. If the transmitter is located on the top of the building, radiowave experiences diffraction on the rooftop and it influences the total received signal strength.

  • PDF

A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Cracks Repairing Material using on the Underground Structure (지붕용 톱코팅재의 내구성 향상에 관한 성능 및 평가방법에 관한 기초적 연구)

  • Park, Jin-Sang;Kang, Hyo-Jin;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.517-520
    • /
    • 2006
  • The waterproofing of Building on the roof has been exposed more underground or the other part of waterproofing than environmental factor(solar heat, UV, salt, acid rain, wind, temperature, snow, rain, etc.) or physical factor. So it must be have a waterproofing performance and it has a special technique for the maintaining of concrete durability. Therefore, exposed waterproof layer has to protected from UV, solar heat, rain and the outside environment also, to endurance durability methods spread face plate topcoat material on the waterproof layer. But, actuality faceplate waterproof layer of topcoat materials are unbearable to UV, solar heat and moisture etc. and it doesn't have adhesion with waterproof layer in the middle. So it happens to crack, separating and heaving etc. Therefore, in the study, we will suggest that using of the exposed roof waterproof layer topcoat materials test method manage rooftop waterproof layer for the durability and the stability.

  • PDF

Building Modeling and Terrain Integration System on Satellite Image (위성영상을 이용한 건물 모델링 및 지형 정합 시스템)

  • Oh, Seon-Ho;Jung, Soon-Ki;Kim, Sang-Hee;Kim, Jeong-Hwan
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06c
    • /
    • pp.549-554
    • /
    • 2008
  • 도시와 같은 광범위한 영역에 대한 지형, 지물의 기하 정보를 추출 또는 복원하는 기술은 공간 영상정보 시스템을 비롯한 다양한 응용분야에서 사용되고 있으며, 이러한 필요에 따라 중요성이 더욱 커지고 있다. 본 논문은 위성 영상에서 건물의 footprint와 rooftop, 그림자 정보를 이용하여 건물을 반 자동으로 모델링하고, 이를 지형에 정합하는 시스템을 제안한다. 제안하는 시스템은 사용자의 직접적인 조작과 자동으로 이루어는 부분을 조합하여, 최소한의 사용자 조작으로 건물을 모델링하고, 지형에 의한 요소를 고려하여 건물의 실제 위치를 보정하여 지형과 정합을 수행한다.

  • PDF