• 제목/요약/키워드: building rooftop

검색결과 128건 처리시간 0.033초

복사냉각 시스템에서 커버의 영향 (The Experimental Study of Radiant Cooling Test System under Different Covers)

  • 변기홍
    • 설비공학논문집
    • /
    • 제19권11호
    • /
    • pp.797-802
    • /
    • 2007
  • The effects of window cover on the performance of the plate type radiant cooling test system are studied. The cover materials tested are 2mm, 1mm, 0.7mm glass, Cokin 007 filter, and PVC film. The measurements are performed during the September nights of 2005 at the rooftop of the building in Seoul. The equivalent height of the building is about a building with twelve floors. The radiant cooling performance of the black painted and aluminum film coated plate are compared under no cover condition. Also the results are compared when the system has cover over the plate. In general, the covers reduce the radiant cooling temperature differences during the nighttime. Among these covers, the PVC film cover shows the best performance. In some cases, the plate with PVC film cover shows lower temperatures than the system without cover.

통계적 방법을 이용한 복층 저소음포장의 소음저감효과 분석 (An Analysis on Noise Reduction Effects of Two-Layer Low Noise Pavements using Statistical Methods)

  • 이상혁;한대석;유인균;이수형
    • 한국도로학회논문집
    • /
    • 제19권6호
    • /
    • pp.1-11
    • /
    • 2017
  • PURPOSES : The purpose of this study is to compare noise reduction quantities between before/after two-layer low noise pavement implementation using equivalent noise level analysis and to analyze the noise reduction effects of the two layer low noise pavement with a statistical method such as the Anderson-Darling Test. METHODS : In order to compare and to analyze noise reduction effects between before/after two-layer low noise pavement implementation, data acquisition as noise levels on a roadside and an apartment rooftop was conducted in the study area. The equivalent noise level was estimated in order to compare noise reduction quantities and the Anderson-Darling Test was carried out for estimating noise reduction effects of the two-layer low noise pavement. RESULTS : The equivalent noise levels of before/after two-layer low noise pavement implementation for the roadside during the daytime are 65.355 dB and 63.520 dB and during the nighttime are 62.463 dB and 59.088 dB. The equivalent noise levels for the apartment rooftop during daytime are 57.301 dB and 59.088 dB and during the nighttime are 54.616 dB and 52.464 dB. Also two-layer low noise pavement decreased the noise reduction effects estimated with the statistical method as the Anderson-Darling test for the roadside during the daytime by around 66.68% and decreased noise reduction effects on the roadside during the nighttime by 0.70%. Moreover it reduced noise reduction effects in the apartment rooftop during the daytime and nighttime by 0% and 96.32%, respectively. CONCLUSIONS : Based on the result of this study, two-layer low noise pavement can positively affect noise reduction during both the daytime and nighttime according to the results of estimating the equivalent noise levels and the Anderson-Darling test.

The Research Regarding the Visual Continuity of the Green in the Re-development Area by Using the Aerial Photograph

  • Lee Hyuk-Hae;Koshimiz Hajime
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • 제2호
    • /
    • pp.102-108
    • /
    • 2004
  • In the city of Asia like Seoul and Tokyo, aggregate power is poured into the city making which is suitable in new age. Large-scale re-development is active in various places as the present condition, As for the various East Asian cities, high-level utilization conversion of the land and high conversion of the building are advanced. As for these realities, the re-development is advanced in the situation that has not been clarified enough though it is true that green of the city has decreased. This research was aimed at the clarifying the allocation of greenery when proceeding with town planning projects by quantifying the possibility of allocating greenery in the form of rooftop landscaping in redeveloped areas. Moreover, the distribution of the green in the re-development region was calculated and the coexistence level of green space was calculated, The realities of a desirable green were clarified in the spectacle by understanding a sight and spatial continuousness in the green. In order to clarify the potentiality of roof greenery revaluating, the research was conducted by analyzing from aerial photographs, in Tokyo and Seoul, And the flow of the research was conducted by selection of research object area, taking pictures, acquisition of the aerial photography, rearrangement the data and the analysis. As a result, I was able to prepare a land vegetation coverage classification chart and obtain data pertaining to the level of urban and green tract of land for the researched cities of Tokyo and Seoul. By analyzing this data, we were able to indicate patterns of greenery unable to be obtained through data from ratio of vegetation coverage and ascertain the effectiveness of rooftop landscaping.

  • PDF

서울 은평 뉴타운 1지구 조경설계 (A Landscape Design Proposal for Eunpyeong New Town, Seoul)

  • 김순분;진양교
    • 한국조경학회지
    • /
    • 제33권2호
    • /
    • pp.111-121
    • /
    • 2005
  • The Seoul Housing Corporation pronounced an alternative design competition and a bidding for Eunpyeong New Town in December of 2004. At first many construction companies were interested in the first New Town Project. But at last a few companies had proposed the alternative design and construction cost. This project needed a conjunction of design ideas and technology know-hows. And the client wanted the brand power of construction company. Ultimately the Corporation hoped that the first New Town Project will end up with high quality successfully. This competition had started with the original construction drawings. Then it needed some alternative ideas and the lowest cost. There were two drawings of non changeable part and changeable part. Non changeable parts are structure like housing unit plan, underground parking lots. Changeable parts are outdoor layout, interior design and building facade. So we tried all ideas of landscape technology and design principles within limited guidelines. The author applied new technology like tilted rooftop greening and sustained container greening on high-rise apartment house. This green technology will be the first trial in Seoul and in the world as well. Daewoo Corporation have accumulated greening technology through the researches by national funding since 2002. Through this New Town Project the green technology will go forward step by step.

Millimeter-wave diffraction-loss model based on over-rooftop propagation measurements

  • Kim, Kyung-Won;Kim, Myung-Don;Lee, Juyul;Park, Jae-Joon;Yoon, Young Keun;Chong, Young Jun
    • ETRI Journal
    • /
    • 제42권6호
    • /
    • pp.827-836
    • /
    • 2020
  • Measuring the diffraction loss for high frequencies, long distances, and large diffraction angles is difficult because of the high path loss. Securing a well-controlled environment to avoid reflected waves also makes long-range diffraction measurements challenging. Thus, the prediction of diffraction loss at millimeter-wave frequency bands relies on theoretical models, such as the knife-edge diffraction (KED) and geometrical theory of diffraction (GTD) models; however, these models produce different diffraction losses even under the same environment. Our observations revealed that the KED model underestimated the diffraction loss in a large Fresnel-Kirchhoff diffraction parameter environment. We collected power-delay profiles when millimeter waves propagated over a building rooftop at millimeter-wave frequency bands and calculated the diffraction losses from the measurements while eliminating the multipath effects. Comparisons between the measurements and the KED and GTD diffraction-loss models are shown. Based on the measurements, an approximation model is also proposed that provides a simple method for calculating the diffraction loss using geometrical parameters.

Building Integrated Photovoltaics: Technical and Aesthetic Prospects

  • Polgampola Chamani Madara;Hasnain Yousuf;Muhammad Aleem Zahid;Suresh Kumar Dhungel;Youngkuk Kim;Junsin Yi
    • 한국전기전자재료학회논문지
    • /
    • 제37권2호
    • /
    • pp.154-163
    • /
    • 2024
  • The energy demand in the world is expected to exceed 740 million TJ by 2040 and our dependence on fossil fuels needs to be switched to sustainable and renewable energy sources like solar energy. Building Integrated Photovoltaic (BIPV) is one of the best approaches to extracting solar energy. There are more than 200 BIPV products in the market currently but when it comes to integrating these products into the technical aspects such as buildings' structural integrity, thermal, daylight retainment and aesthetic prospects to be considered. The share of BIPV integration potential of different building types in the world of residential, agricultural, industrial, commercial and other buildings account for 66%, 4.8%, 8.1%, 19.9%, and 1.2% accordingly. Many solar technologies developed to achieve architectural requirements, but the main problem is the trade-off between efficiency and aesthetic appeal, which is less than 10% in coloured and transparent solar modules. This paper discusses the different applications of solar photovoltaics (PV) in building architecture, technical requirements, and different module technologies. The article provides a comprehensive guide for researchers and designers working on the development of BIPV integrations.

무인기를 이용한 Last-Mile 서비스를 위한 배송 자동화 및 영상기반 착륙 알고리즘 연구 (Research of the Delivery Autonomy and Vision-based Landing Algorithm for Last-Mile Service using a UAV)

  • 이한섭;정훈
    • 산업경영시스템학회지
    • /
    • 제46권2호
    • /
    • pp.160-167
    • /
    • 2023
  • This study focuses on the development of a Last-Mile delivery service using unmanned vehicles to deliver goods directly to the end consumer utilizing drones to perform autonomous delivery missions and an image-based precision landing algorithm for handoff to a robot in an intermediate facility. As the logistics market continues to grow rapidly, parcel volumes increase exponentially each year. However, due to low delivery fees, the workload of delivery personnel is increasing, resulting in a decrease in the quality of delivery services. To address this issue, the research team conducted a study on a Last-Mile delivery service using unmanned vehicles and conducted research on the necessary technologies for drone-based goods transportation in this paper. The flight scenario begins with the drone carrying the goods from a pickup location to the rooftop of a building where the final delivery destination is located. There is a handoff facility on the rooftop of the building, and a marker on the roof must be accurately landed upon. The mission is complete once the goods are delivered and the drone returns to its original location. The research team developed a mission planning algorithm to perform the above scenario automatically and constructed an algorithm to recognize the marker through a camera sensor and achieve a precision landing. The performance of the developed system has been verified through multiple trial operations within ETRI.

옥상 노출방수용 PVC 방수시트의 방위별(남, 북) 장기옥외폭로에 따른 물성 변화 연구 (A Study on Changes of Physical Properties of Rooftop Exposed Waterproofing PVC Sheet based on Longterm Outdoor Exposure Testing with Bearings (North, South))

  • 안기원;문유석;김천학;송제영;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.147-148
    • /
    • 2015
  • Exposed type waterproofing PVC sheets installed on structure rooftops are subject to changes in physical properties after longterm exposure to sunlight. Particularly when consideration the rotational movement of sunlight over the day through the course of the sun rising from the east and setting in the west, in the case of flat roofs the amount of UV ray the the surface of the PVC waterproofing sheet receives may be even throughout, but in cases of slanted rooftops the sunlight exposure may be uneven across the surface. In this regard, this study examines the effect uneven sunlight exposure on the exposed type waterproofing PVC sheets installed on slanted rooftops.

  • PDF

방수시트의 평행접합방법에 따른 인장성능 평가연구 (A Study on the Evaluation of Tensile Performance According to Pareral Jointing Methods of the Sheet Membrane Waterproofing System)

  • 이정윤;오미현;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술대회지
    • /
    • pp.39-44
    • /
    • 2004
  • A heat and room temperature construction method of asphalt have been mainly applying to rooftop waterproofing in concrete structure, and the rest construction method are sheet, membrane and mortar waterproofing construction method. In particular, joint method in sheet waterproof method is as overlap joint which on being reinforced with fiber and tape, have been applying for job site to mechanical fix using protection disk and anchorage and metal ironwork on the end of sheet. These construction method cause cutting off joint of sheet as behavior of structure according to repairs of sheet itself and thermal conduct, outdoor air environment. In conclusion, we analyzed and examined the application of various sheets and piece ashes about superior 'I' joint which divide from one and the other sheet and progressed about joint construction method of fixing method for overlap.

  • PDF

옥상 및 인공지반 방근공사에 적용되는 TPO시트의 재생 소재 적용에 따른 인장성능 변화 연구 (Study on tensile performance change by recycled materials of TPO sheet applied to rooftop and artificial ground Rootproofings)

  • 김선도;김진성
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.103-104
    • /
    • 2018
  • Recently, in addition to greening of roof and artificial soil, Rootproofing to prevent damage to the waterproof layer and structures by roots is recognized as an important task. Therefore, various related products and construction methods have been developed and applied in the field. However, in the case of synthetic polymer-based sheets most commonly used in domestic construction sites, Most are produced using 100% new materials that are not suitable for green trends such as resource conservation and environmental protection. Therefore, in this study, we developed TPO sheet using recycled material, which is a technology that can secure eco-friendliness by utilizing recycled resources. As a result of the evaluation of tensile performance of the TPO sheet according to the recycled material content, The tensile strength of the specimens with the recycled content of 50 ~ 70% was the highest, The elongation rate of the specimen with the recycled content of 30 ~ 40% was the best.

  • PDF