• 제목/요약/키워드: bubble sheets

검색결과 34건 처리시간 0.025초

건조수축 저감형 유동화제를 사용한 콘크리트의 현장적용 (Field Application of Concrete Using Drying Shrinkage-Reducing Superplasticizer)

  • 신재경;오치현;최진만;이성연;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.13-16
    • /
    • 2006
  • This study investigates filed application in Daebul Free Trade Zone of a flowing method using drying shrinkage-reducing superplasticizer(SRS) and an insulating curing method using double bubble sheets. Test showed that fresh concrete satisfied target slump and air content. A structure adding SRS significantly decreased the total bleeding capacity and accelerated the setting time. As for the crack occurrence, the structure applying the flowing method and double bubble sheets simultaneously exhibited the most favorable crack endurance, while conventional concrete showed more than 1mm size of crack in overall, and a structure applying only the flowing method partially presented micro crack. For the area proportion of crack occurrence, the structure using the double bubble sheets indicated 9.8%, while others applying flowing method was 28%, compared with 100% of conventional one. Standard curing specimens had about $3{\sim}6%$ higher compressive strength than that of specimens cured at adjacent field construction. In addition, using SRS improved about $5{\sim}7MPa$, than that of conventional concrete at 91 days elapse.

  • PDF

버블시트 피복방법 변화에 따른 동절기 노출철근의 온도분포 특성 (Features of Temperature Distribution of Exposed Reinforcement Bars Depending on Changes of Covering Methods of Bubble Sheets)

  • 이제현;이상운;이정교;양성환;경영혁;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.11-12
    • /
    • 2016
  • The contemporary buildings are becoming super-taller gradually as the industry evolves. Accordingly, winter concrete also became an important element for the year-round construction since shortening of a construction duration became important. Accordingly, this research team once developed a double bubble sheet as concrete cover curing compound during winter. But since there is no proper countermeasure for the exposed reinforcement bars, it is worried that the concrete can be damaged by exposed frozen reinforcement bars at a low temperature during the initial period. Therefore, in this study, it is intended to review the temperature history of the reinforcement bars depending on changes of the covering methods of the exposed reinforcement bars by using bubble sheets.

  • PDF

양생온도 변화 및 버블시트 두께변화에 따른 콘크리트의 온도이력특성 (Temperature History of Concrete Corresponding to Various Bubble Sheets Layer and Curing Temperature)

  • 홍석민;백대현;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.21-25
    • /
    • 2008
  • In this paper, the temperature history and the strength development of concrete corresponded to various bubble sheets layer and curing temperature. Based on the results, In case of the test temperature of -5℃, concrete subject in the exposure condition, result in a frost damage at initial stage by a fall of below zero temperature. In case of the combination of PE film and non woven fabric was after 36 hour, and combination of bubble sheet over double, a tremendous insulating effect of bubble sheet over double is confirmed due to the temperature of concrete fall of below zero temperature after 60 hours. Meanwhile, regarding the -15℃ of temperature, special measure for insulation curing is necessary to secure stability against early frost damage because frost damage was not affected by the lapping thickness of bubble sheet subjected to severe cold weather condition.

  • PDF

표면 양생시트 조합에 의한 서중콘크리트용 표면 양생공법 (Surface Curing Method of Hot weather Concreting with the Combination of Surface Curing sheets)

  • 이주석;김종백;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.785-788
    • /
    • 2006
  • This paper investigates the temperature history of slab mock-up specimens with various surface curing sheets, in order to determine a favorable surface curing method in hot weather condition. Test showed that insulating double bubble sheets+aluminum foil simultaneously on the upper section of a specimen prevented an increase of sudden temperature and a decrease of vaporization when placed during the hot weather condition. It also secured the high strength in early age. Therefore it is found that using the double bubble sheets+aluminum foil on concrete surface declined the plastic and drying shrinkage and inclined the early strength, thus improving the concrete quality.

  • PDF

건축물 해체공사용 친환경 방음/방진막 개발 (Eco-sound barrier and dust controller for building demolition )

  • 김영태;원지민;최하란;이은미
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.241-242
    • /
    • 2023
  • This paper discusses an innovative acoustic membrane developed by doAZ Co., Ltd., offering enhanced noise barrier and dust control for urban construction and demolition, surpassing the performance of traditional non-woven fabrics. The membrane is made from recyclable bubble sheets and designed to be seamlessly integrated into single and double-row scaffolding systems, ensuring broader applicability and sustainability.

  • PDF

건조수축 저감형 유동화제 및 2 중 버블시트를 사용한 콘크리트의 현장적용 (Field Application of the Concrete with the Combination of Drying Shrinkage-Reducing Superplasticizer and Double Layer Bubble Sheet)

  • 한천구;오치현;신재경
    • 한국건축시공학회지
    • /
    • 제7권1호
    • /
    • pp.107-113
    • /
    • 2007
  • This study investigates the filed application in Daebul Free Trade Zone applying both a flowing method using drying shrinkage-reducing superplasticizer(SRS) and an insulating curing method using double layer bubble sheet. Test results showed that fresh concrete satisfied target slump and air content. A structure adding SRS significantly decreased the total bleeding capacity and accelerated the setting time. As for the crack occurrence, the structure applying the flowing method and double bubble sheets simultaneously exhibited the most favorable crack endurance, while conventional concrete showed more than 1mm size of crack in overall. In addition, a structure applying the flowing concrete method partially presented the micro crack. For the area proportion of crack occurrence, the structure using the double bubble sheets indicated 9.8%, while others applying flowing concrete method was 28%, compared with that of conventional one. For the compressive strength of specimens, standard curing specimens indicated $3{\sim}33%$ higher value than that of specimens cured besides the field construction. The specimens containing SRS improved the strength of $2{\sim}6MPa$, which is $10{\sim}22%$ higher than that of conventional concrete.

이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용 (Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather)

  • 홍석민;백대현;김종;전충근;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.57-60
    • /
    • 2008
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete and mass concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 6 and 15℃ even in case outside temperature drops -9℃ below zero until the 2nd day from piling, and in the case of mass concrete, with the maximum temperature difference between the center and surface less than 4℃, crack occurrence index was close to 2 and no hydration heat crack occurred by internal constraint. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용 (Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather)

  • 홍석민;이일선;백대현;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.25-28
    • /
    • 2009
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 5 and $l0^{\circ}C$ even in case outside temperature drops $-11^{\circ}C$ below zero until the 4nd day from piling. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

광발열시트 및 2중 버블시트를 조합한 보온양생시트를 적용한 콘크리트의 양생 효과 (Effect of The Heat Curing Sheet Combined with Duble Layered Bubble Sheets and Light Heat Generating Materials on Surface Temperature History of the Concrete)

  • 한천구;한민철;정웅선;남상헌;김수호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.39-40
    • /
    • 2022
  • This study is intended to examine the curing effect of the combination of the bubble sheet on the concrete by analyzing the temperature profile and core strength of the simulated concrete structure. The test results relvealed that the average temperature of the concrete applying photothermal sheet overlapped with the double bubble sheet at the bottom was 23.5℃, which had the highest insulation and insulation effect compared to other types of surface insulation curing sheets, and the core strength increased by up to 56%.

  • PDF

저온환경에서의 양생시트 변화에 따른 콘크리트의 온도이력 특성 (Temperature History of the Concrete Corresponding to Various Curing Sheets in the Low Temperature)

  • 백대현;홍석민;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.781-784
    • /
    • 2008
  • 본 연구에서는 저온 환경에서 단열양생시트 변화에 따른 콘크리트의 온도이력 및 강도특성을 검토하였다. 실험결과 -5$^{\circ}$C에서 노출과 air cap포장지의 경우 초기 24시간 이내로 콘크리트의 온도가 영하의 온도로 저하되어 초기동해가 발생되었다. 반면, 비닐+부직포의 경우 초기 24시간이내의 최저온도가 약 3$^{\circ}$C로 영상의 온도를 유지하였고 이중버블시트의 경우 약 7$^{\circ}$C로 나타나 양호한 단열 보온성능을 나타내었다. 코어압축강도를 측정한 결과 비닐+부직포와 이중버블시트로 양생한 시험체의 압축강도가 양생초기의 우수한 단열효과로 인해 다른 시험체의 압축강도보다 높게 나타났다.

  • PDF