• 제목/요약/키워드: brittle failure

검색결과 585건 처리시간 0.03초

Mechanical Properties of Fiber Reinforced Rapid-Setting Cement Mortars (초속경섬유보강모르타르의 역학적 특성)

  • Oh, Byung-Hwan;Jang, Kyu-Hyoun;Shin, Kyung-Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.341-344
    • /
    • 2005
  • Recently, the application of Rapid Setting Cement has been gradually increased as an important construction. However, Rapid Setting Cement shows brittle failure. Therefore, in this study, tests are carried out using Rapid Setting Cement containing fiber in order to improve such a poor property. silica-cement ratio are varied. According to experimental results, Fiber reinforced Rapid -Setting Cement showed the high ductility and strain capacity regardless of silica-cement ratio. With 0.5 silica-cement ratio, a bending strength is the highest.

  • PDF

Flexural Test on Beam-Column Connections Using High Strength Concrete and GFRP bars (고강도 콘크리트와 GFRP 보강근을 사용한 보-기둥 접합부 휨 실험)

  • Lee, Hye-Jin;Kim, Si-Jun;Yang, Keun-Hyeok;Park, Sang-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.177-178
    • /
    • 2017
  • The beam-column connection using high-strength GFRP bars exhibited a comparable flexural strength but brittle failure mode, when compared with those of connection using high-strength steel reinforcement.

  • PDF

Stress Response of Cement Interface on Manufacturing Process of a Suspension Insulator (송전선용 현수애자 양생공정에서 발생하는 접착부의 응력변화)

  • Woo, Byung-Chul;Han, See-Won;Cho, Han-Goo
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1448-1450
    • /
    • 2003
  • The suspension insulators are subjected to harsh environment in service for a long time. Long term reliability of the insulators is required for both mechanical and electrical performances. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing.

  • PDF

Simulation of crack initiation and propagation in three point bending test using PFC2D

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Hedayat, Ahmadreza;Nezamabadi, Maryam Firoozi;Karbala, Mohammadamin
    • Structural Engineering and Mechanics
    • /
    • 제66권4호
    • /
    • pp.453-463
    • /
    • 2018
  • Three points bending flexural test was modelled numerically to study the crack propagation in the pre-cracked beams. The pre-existing double internal cracks inside the beam models were considered to investigate the crack propagation and coalescence paths within the modelled samples. Notch configuration effects on the failure stress were considered too. This numerical analysis shown that the propagation of wing cracks emanating from the tips of the pre-existing internal cracks caused the final breaking of beams specimens. It was also shown that when two notches were overlapped, they both mobilized in the failure process and the failure stress was decreased when the notches were located in centre line. However, the failure stress was increased by increasing the bridge area angle. Finally, it was shown that in all cases, there were good agreements between the discrete element method results and, the other numerical and experimental results. In this research, it is tried to improve the understanding of the crack propagation and crack coalescence phenomena in brittle materials which is of paramount importance in the stability analyses of rock and concrete structures, such as the underground openings, rock slopes and tunnel construction.

Shear Behaviour of RC Beams Strengthened by Multi directional channel-type FRP Plate (다방향 채널형 FRP판으로 보강된 철근콘크리트 보의 전단거동)

  • Han, Jae-Won;Hong, Ki-Nam;Han, Sang-Hoon;Kwon, Yong-Kil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.173-176
    • /
    • 2008
  • The aim of this paper is to clarify the shear behavior of RC beams strengthened with channel-type Fiber Reinforced Polymer(FRP) plates. Fourteen RC beams were specifically designed. All the beams were tested under four point bending and extensively instrumented to monitor strains, cracking, load capacity and failure modes. The structural response of all beams is then critically analyzed in terms of deformability, strength and failure processes. It is shown that with channel-type Fiber Reinforced Polymer(FRP) plates, a brittle debonding failure of beams bonding FRP in the concrete surface can be transformed to an almost ductile failure with well-defined enhancement of structural performance in terms of both deformation and strength.

  • PDF

Experimental investigation on optimal shear strengthening of RC beams using NSM GFRP bars

  • Ramezanpour, M.;Morshed, R.;Eslami, A.
    • Structural Engineering and Mechanics
    • /
    • 제67권1호
    • /
    • pp.45-52
    • /
    • 2018
  • Several techniques have been developed for shear strengthening of reinforced concrete (RC) members by using fiber reinforced polymer (FRP) composites. However, debonding of FRP retrofits from concrete substrate still deemed as a challenging concern in their application which needs to be scrutinized in details. As a result, this paper reports on the results of an experimental investigation on shear strengthening of RC beams using near surface mounted (NSM) FRP reinforcing bars. The main objective of the experimentation was increasing the efficiency of shear retrofits by precluding/postponing the premature debonding failure. The experimental program was comprised of six shear deficient RC beams. The test parameters include the FRP rebar spacing, inclination angle, and groove shape. Also, an innovative modification was introduced to the conventional NSM technique and its efficiency was evaluated by experimental observation and measurement. The results testified the efficiency of glass FRP (GFRP) rebars in increasing the shear strength of the test specimens retrofitted using conventional NSM technique. However, debonding of FRP bars impeded exploiting all retrofitting advantages and induced a premature shear failure. On the contrary, application of the proposed modified NSM (MNSM) technique was not only capable of preventing the premature debonding of FRP bars, but also could replace the failure mode of specimen from the brittle shear to a ductile flexural failure which is more desirable.

A STUDY ON THE FRACTURE MODES AND FAILURE LOADS OF THE VARIOUS TYPES OF RESTORATION FOR THE ENDODONTICALLY TREATED ANTERIOR TEETH (전치부 근관충전후 수복형태에 따른 파절형태 및 파단하중에 관한 연구)

  • Park, Young-Sook;Choi, Sung-Keun
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.45-51
    • /
    • 1982
  • An endodontically treated tooth is likely to be brittle than a vital tooth. Internal structure of the tooth has been weakened due to a significant removal of dentin by coronal access, canal preparation. There are many controversies concerning with various methods of reinforcing an intact anterior tooth that has endodontic treatment. In this experiment, 128 extracted maxillary anterior teeth were endodontically treated, and prepared with 4 methods of restorations; Composite resin filling with zinc phosphate cement, composite resin filling without zinc phosphate cement, composite resin filling with post, and metal crown with post. An Instron testing machine was used to measure the fracture loads of the specimens. The means of the failure loads for the 4 groups were compared by F-test statistically and the failure modes were observed. The results were as follows; 1. There were no statistically significant difference between the failure loads of the four methods of restoration. 2. Teeth without post were fractured in a horizontal or oblique plane through upper or middle third of the root. 3. In the posted teeth, fractures were occurred around the post. 4. In the metal crowned teeth with post, the fracture were occurred around the post or coronal area.

  • PDF

Static vulnerability of existing R.C. buildings in Italy: a case study

  • Maria, Polese;Gerardo M., Verderame;Gaetano, Manfredi
    • Structural Engineering and Mechanics
    • /
    • 제39권4호
    • /
    • pp.599-620
    • /
    • 2011
  • The investigation on possible causes of failures related to documented collapses is a complicated issue, primarily due to the scarcity and inadequacy of information available. Although several studies have tried to understand which are the inherent structural deficiencies or circumstances associated to failure of the main structural elements in a reinforced concrete frame, to the authors knowledge a uniform approach for the evaluation building static vulnerability, does not exist yet. This paper investigates, by means of a detailed case study, the potential failure mechanisms of an existing reinforced concrete building. The linear elastic analysis for the three-dimensional building model gives an insight on the working conditions of the structural elements, demonstrating the relevance of a number of structural faults that could sensibly lower the structure's safety margin. Next, the building's bearing capacity is studied by means of parametric nonlinear analysis performed at the element's level. It is seen that, depending on material properties, concrete strength and steel yield stress, the failure hierarchy could be dominated by either brittle or ductile mechanisms.

Retrofitting of shear damaged RC beams using CFRP strips

  • Altin, Sinan;Anil, Ozgur;Toptas, Tolga;Kara, M. Emin
    • Steel and Composite Structures
    • /
    • 제11권3호
    • /
    • pp.207-223
    • /
    • 2011
  • The results of an experimental investigation are presented in this paper for retrofitting of shear damaged reinforced concrete beams by using U shaped CFRP strips. The experimental program is consisted of seven shear deficient T cross sectioned 1/2 scale simply supported beam specimens. One beam was used as reference specimen, and the remaining six specimens were tested in two stages. At the first stage, specimens were shear damaged severely, and then were retrofitted by using CFRP strips with or without fan type anchorages. Finally, retrofitted beams were tested up to failure. Three different CFRP strip spacing were used such as 125 mm, 150 mm, and 200 mm. The effect of anchorages on shear strength and behavior of the retrofitted specimens is investigated. CFRP strips without anchorages improved the shear strength, but no flexural failure mode was observed. Specimens showed brittle shear failure due to peeling of CFRP strip from RC beam surface. Shear damaged specimens retrofitted with anchoraged CFRP strips showed improved shear strength and ductile flexural failure. Maximum strains at anchoraged strips were approximately 68% larger than that of strips without anchorages.

The Efficiency of Steel Brace Strengthening of School Buildings according to the Failure Mode of Columns (기둥 파괴모드에 따른 학교 건물 철골 가새 보강의 효율성)

  • Lee, Hee Seop;Kim, Taewan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • 제27권2호
    • /
    • pp.101-109
    • /
    • 2023
  • Steel brace strengthening is the most popular seismic rehabilitation method for school buildings. This is because the design can be conducted by using relatively easy nonlinear pushover analysis and standard modeling in codes. An issue with steel brace strengthening is that the reinforced building should behave elastically to satisfy performance objectives. For this, the size of steel braces should be highly increased, which results in excessive strengthening cost by force concentration on existing members and foundations due to the considerable stiffness and strength of the steel braces. The main reason may be the brittle failure mode of columns, so this study investigated the relationship between the efficiency of steel brace strengthening and column failure modes. The result showed that the efficiency is highly dependent on the shear capacity ratio of columns and structural analysis methods. School buildings reinforced by steel braces do not need to behave elastically when the shear capacity ratio is low, and pushover analysis is used, which means reducing steel material is possible.