A Study the Physicochemical Characteristics of Municipal Solid Wastes

  • Kim, Young-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.4
    • /
    • pp.35-41
    • /
    • 2003
  • The objective of this study was investigate the generation rates, composition, proportion and calorific values each of material in the municipal solid wastes as well as the effect of incineration residual leachate on the environment in Yangsan sanitary landfill site. The results were as follows ; The annual average generation rate of municipal solid wastes in Yang-san is approximately 2.0 kg/cㆍd. The weight percent of combustible matters is on average 78∼87% and the lower heating values of municipal solid wastes is measured to be more than 2,151 kcal/kg after removing the briquette component. The food waste was major source of solid wastes in Yang-san city as 35% and its variation by seasons was negligible. Combustible part was larger than incombustible part of the domestic solid wastes in spring and summer. It is recommended that municipal solid wastes be treated by multiple methods such as the sanitary landfill, resources and recovery, composting and incineration.

A Study on Indoor and Personal Exposures Concentrations to Carbon Monoxide in the Asan Area

  • Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.1-3
    • /
    • 2000
  • Indoor carbon monoxide (CO) concentration and personal CO exposures were measured Asan where CO poisoning from twenty coal usage briquette as a domestic fuel to cook and space heating. Twenty-five were houses selected from the Asan area for the survey conducted in February 1997. Newly developed passive CO samplers were placed in the kitchen and living room for the indoor concentration measurement and were worn by homemakers for personal exposure monitoring. The daily average of indoor CO concentration was 16ppm in the kitchen and 10ppm in the living room. The indoor concentration and personal exposures to CO were different in types of the space heating system. House ventilating methods and socioeconomic conditions were also important factors in determining the indoor and personal CO level in Asan.

  • PDF

Indoor and Personal Exposure to Carbon Monoxide in Homes (一酸化炭素의 家庭內 濃度 및 主婦의 個人曝露濃度에 關한 調査硏究)

  • 김윤신;손부순;유행행웅
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.97-102
    • /
    • 1990
  • A pilot field study was conducted to measure indoor and personal exposure to carbon monoxide (CO) levels using personal monitors from January to February in 1989. The principal objectives of the study was to design and evaluate the research protocol and the instrumentation performance for application to the conduct of a large-scale personal monitoring program. The mean CO concentrations in kitchen and in bedroom were 23.4 and 11.9 ppm, respectively, while mean concentration of personal CO exposure was 18.9 ppm. It was found that the mean CO concentrations in kitchen exceeded 20 ppm of the Korea ambient CO standard(8-hr average) not to be exceeded more than three times per year. The results suggest that indoor CO levels in Korean houses appear to be affected by use of coal briquette for heating any cooking.

  • PDF

An Improved Composite Estimator for Cut-off Sampling

  • Hwang, Hee-Jin;Shin, Key-Il
    • Communications for Statistical Applications and Methods
    • /
    • v.20 no.5
    • /
    • pp.367-376
    • /
    • 2013
  • Cut-off sampling is widely used for a highly skewed population like a business survey by discarding a part of the population (the take-nothing stratum). In this paper, we suggest a new composite estimator of the take-nothing stratum total obtained by use of the survey results of the take-nothing stratum and a take-some sub-stratum (a part of take-some stratum) for a more accurate estimate of the population total. Small simulation studies are conducted to compare the performances of known estimators and the new composite estimator suggested in this study. In addition, we use briquette consumption survey data for real data analysis.

A Study on the Component Analysis of Municipal Solid Wastes and the Effect of Landfill Leachate on the Evironment (폐기물 성상분석과 매립장 침출수가 환경에 미치는 영향에 관한 연구)

  • 윤오섭
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.1
    • /
    • pp.58-62
    • /
    • 1992
  • The objective of this study is to investigate the generation rates, composition, propertion and lower heating values of each material in the municipal solid wastes(MSW) as well as the effect of landfill leachate on the environment in Taejon. The results are as follows: 1. The annual average generation rate of MSW in Taejon is approximately 1.7kg/c.d. 2. The weight percent of combustible matters is on average 80 and the lower heating value of MSW is measured to be more than 1,700 kcal/kg after removing the briquette component. 3. It is necessary for us to take a proper management system for leachate treatment in the landfill because it has many problems in the sewage and groundwater. 4. It is recommeded that MSW be treated by multiple methods such as the sanitary landfill, resources and recovery, composting and incineration.

  • PDF

Study on the Reaction Characteristics of Self-reducing $Nb_2O_5$ Briquettes (자기 환원성 $Nb_2O_5$ 브리켓의 반응특성 연구)

  • Kim M. S.;You B. D.;Wi C. H.;Yun D. J.;Choi S. O.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.333-336
    • /
    • 2005
  • The reduction behavior of $Nb_2O_5$ in aluminum containing self-reducing briquettes(SRNB) was investigated. The time required for slag/metal equilibrium was estimated as about 20 minutes from the addition of SRNB on to the surface of molten steel. The maximum yield of Nb was expected with the slag composition of $60\%CaO-40\%Al_2O_3$. When $CaCO_3$ was used as a flux, the oxidation loss of Al by $CO_2$ should be compensated, and the chemical equivalent ratio of Al to $Nb_2O_5$ of about 1.43 was required to maximize the yield of Nb.

  • PDF

Study on the Flow of Briquette Gas in the Ondol Heating System (Chimney Draft of Low Temperature Moist Air) (온돌의 연탄개스유량에 관한 연구(1) (함습저온열기류의 굴뚝통풍력))

  • Min Man-Ki
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.2
    • /
    • pp.119-128
    • /
    • 1975
  • Natural draft and flow which low temperature moist gas produces in the chimney of an Ondol heating system were numerically analysed. Among several factors involved inlet gas temperature has the strongest influence on the chimney performance and then next specific humidity of the gas. Thermal conductivity of the chimney wall, however, has little influence on the performance of such a low temperature chimney. Under given flow conditions there exists an optimum chimney height which gives a maximum flow rate for a given chimney diameter. This optimum value of chimney height inereases with increase in chimney diameter, inlet gas temperature and specific humidity.

  • PDF

A case study of verifying a suicide by carbon monoxide intoxication committed by burning an ignition charcoal briquette (착화탄 연소에 의한 일산화탄소 중독사에서 자살입증에 관한 사례연구)

  • Sung, Tae-myung;Jo, Ju-ik;Ahn, Phil-sang
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.398-408
    • /
    • 2015
  • Carbon monoxide (CO) intoxication, arising from CO from an ignited charcoal briquette (ICB), is a popular means of committing suicide in Korea. Most CO intoxications are related to suicide attempts; however, the possibility of a homicide disguised as a suicide cannot be ruled out. Therefore, forensic investigation of the deceased and the crime scene is crucial to confirm that the deceased committed suicide. Detection of the components of an ICB on the objects suspected of being contacted by the deceased, such as the hands, nostrils, and doorknobs, is essential for linking the crime scene to the victim in the case of suicides by ignited ICBs. The traces from an ICB were analyzed by investigating the morphological characteristics and obtaining elemental compositions. The ICBs were completely different from blackened wood, as detected by discriminant analysis with the elements of carbon and oxygen. We analyzed one case of CO intoxication to demonstrate an excellent procedure for verifying whether a suicide occurred with an ICB. We employed SEM-EDX for the analysis of an ICB, microscope-FT/IR and pyrolysis-GC/MS for a partly burnt resin-type substance, GC/MS for diphenhydramine (a sleeping drug), and GC/TCD for the CO-Hb level. We detected traces of an ICB on the hands, nostrils, and doorknobs, which were all discriminated into an ICB group. Detection of ICB traces from the nostrils could indicate that the deceased started the fire themselves to commit suicide. The partially burnt black material was analyzed as an acrylronitrilestyrene polymer, which is normally used to make bags for carrying or wrapping and could be assumed to have been used to transport the ICB. Diphenhydramine, a sleeping drug, was detected at a level of 2.3 mg/L in the blood, which was lower than that in fatal cases (8-31 mg/L; mean 16 mg/L). A CO-Hb level of 79% was found in the blood, which means that the cause of death was CO intoxication. The steps shown here could represent an ideal method for reaching a verdict of suicide by CO intoxication produced by burning an ICB in a sealed room or a car.

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

Analysis of the Characteristics of Bulking Agents Used in Livestock Manure Composting (축산분뇨 퇴비화에 이용되는 수분조절제의 특성 분석)

  • Kim, Hyeon-Tae;Lee, Min-HO;qasim, Waqas;Lee, Yong-Jin;Kim, Won-Joong;Yoon, Yong-Cheol
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.81-88
    • /
    • 2018
  • This study analyzed the characteristics of 6 recyclable bulking agents which can replace sawdust and rice hulls that are commonly used in livestock manure composting. The content of all the hazardous chemicals found in the bulking agents used in this experiment was between 0.0 and 34.1 ppm, which was noticeably lesser than the maximum content levels of hazardous substances 5.0~900.0 ppm prescribed by the Rural Development Administration(RDA), which means that the bulking agents would be able to replace sawdusts and rice husks. The water content of the bulking agents ranged from a minimum of 12.4% to a maximum of 16.6% in the original state, which was much less than 60%, the optimal moisture content. These results indicate that they would be able to function fully as bulking agents. Their water absorption rate was in the range of minimum 31.9% ~ maximum 600.0%, which showed huge differences among the types of bulking agents. The most appropriate bulking agent in terms of water absorption rate was wood pellets. It was the highest in the wood briquette manufactured by A, which was followed by C and B in the order. The shear strength of the 5 types of bulking agents in the original state was 271.7 N on an average, the highest figure of all, except for the oak briquette whose shear strength could not be measured and the wood pellets in the absorption state. The shear strength in the dry and absorption states then followed, and were 78.0 N and 27.7 N on an average, respectively. The wood briquette of A recorded considerably lower shear strength than that of B and C. Overall, shear strength tended to increase according to lower water absorption rates. Since pine wood chips and oak cuts have relatively greater shear strength even in the absorbing state than the other materials, they will be able to endure some power in the case of stirring with pig droppings.