Optimization of Briquette Manufacturing Conditions Using Steel Sludge (제강슬러지를 이용한 브리켓 제조 조건 최적화 연구)

  • Lee, Dong Soo;Chae, Hui Gwon;Park, Tae Jun
    • Resources Recycling
    • /
    • v.31 no.4
    • /
    • pp.12-18
    • /
    • 2022
  • Korea depends on the import of raw materials such as iron ore and coal for the steel industry. These raw materials have a major impact on the cost, productivity, and quality competitiveness in the global steel industry. To secure the competitiveness of steel companies, it is necessary to reduce the country's dependence on raw materials. This can be achieved using byproducts with a high Fe content, which are primarily generated by the steel industry. These byproducts are available in the form of a very fine powder, which can disperse as dust when used directly in plant processes. Dust dispersion has a negative impact on the environment and can lead to the loss of raw materials. To enable the use of a wide range of Fe-containing byproducts, it is necessary to pretreat them in the form of larger aggregates such as pellets and briquettes. There are several methods to achieve such aggregates. There are two ways to produce briquettes: using a hot briquette, which supplies additional heat to produce briquettes, or using a cold briquette, which does not use heat. A method for producing cold briquettes using Fe-containing byproducts was investigated in this study. The yield ratio and briquette strength were examined under various manufacturing conditions.

촉매제에 의한 연탄깨스 제거에 관한 연구

  • Heo, Jin
    • Journal of the Korean Professional Engineers Association
    • /
    • v.5 no.19
    • /
    • pp.3-16
    • /
    • 1972
  • 1. Purposes and importances of the study. In gaining heating resources by combustion of briquette, which is the necessaries of every day's life, victims occur from poisonous affection of combustion gas (carbon mono-oxide) in every year and this gas attributable to increase death rate proportion to the high demand of briquette usage. It arise great problem ill point of national sanitation. Therefore, the study has a big aim to accomplish depressing CO gas or stimulating comlete combustion by both the methods of physical improvement of present combustion devices and chemical improvement by using V$_2$O$\sub$5/ catalyst to depress CO gas or fasten complete combustion Progress. Sucessful result of this study will not only to decrease the death rate but also to contribute fearless handling of briquette combustion so as to perform improving public Welfare. 2. Contents and scope of study. A. comparison of present and improved fuel hole device. B. Examination of effectness of improved elements. C. Effectness of miffed usage of catalyst. D. Comparison of Catalyst effectness. E. Examination of effectness of black slate containing V$_2$O$\sub$5/. 3. Results and recommendations of the study A. Absolute necessity of supplying secondary air by improved combustion device. B. Oxide Vanadium (V$_2$O$\sub$5/) has the greatest effectness to eliminate CO gas. C. Most effective catalyst of V$_2$O$\sub$5/ containing slate comes from "Samgoe" coal mine. D. By plastering catalyst on the cover plate of fire hole, it stimulate chemical reaction of re-combustion and preserving heat. E. Recommend to continute further precise study to practice with low-cost and handy devices to be applied the study results.

  • PDF

Distribution and Exposure Characteristics of Pneumoconiosis Patients in Fuel Complexes (연료단지 진폐증 환자 분포현황 및 노출특성)

  • Jong-Hyeon Jung
    • Journal of Environmental Science International
    • /
    • v.33 no.2
    • /
    • pp.161-168
    • /
    • 2024
  • This study was conducted to identify the pollutants generated by the fuel complex and to determine the health effects of the surrounding residents. In addition, based on the results of epidemiological surveys and health impact surveys of local residents, we analyze the distribution of patient groups and exposure characteristics according to the distance from the fuel complex boundary. Samples were collected from the briquette plant within the fuel complex and analyzed by SEM-EDXA, X-ray Fluorescence Spectrometer, and ICP. In addition, the distribution of patients and exposure characteristics were analyzed according to the distance from the fuel complex and yard boundaries. Analysis of briquette samples from the fuel complex showed that the average particle size was 10-30 ㎛, the shape was irregular, and SiO2 accounted for more than 50%. It is believed that silica, which causes pneumoconiosis, may have been scattered into the air. In particular, there was a large distribution of 5 ㎛ particles that affect respiratory diseases. According to the analysis of the residential addresses and distribution of pneumoconiosis cases, many pneumoconiosis cases were located in the area between 200 and 500 meters from the boundary of the fuel complex. In addition, 28 pneumoconiosis cases were identified as a result of the epidemiological survey and health impact survey at the fuel complex. In detail, there were 8 cases of occupational pneumoconiosis, 6 cases of environmental pneumoconiosis, and 14 cases of occupational and environmental pneumoconiosis. The confirmed pneumoconiosis cases were located between 0.3 and 1.1 kilometers from the fuel complex. It was found that environmental pollutants generated by the fuel complex adversely affect the health of local residents. In particular, there are many cases of pneumoconiosis in the area between 200 and 500 meters from the boundary of the fuel complex, and this distance is considered to be the direct and indirect impact zone of the briquette plant.

Effects of the Curing Temperature on the Strength of Mortar added Admixtures (양생온도(養生溫度)가 혼화재(混和材)를 사용(使用)한 Mortar의 강도(强度)에 미치는 영향(影響))

  • Kang, Sin-Up;Kim, Seong-Wan
    • Korean Journal of Agricultural Science
    • /
    • v.3 no.2
    • /
    • pp.214-224
    • /
    • 1976
  • This research was attempted as one of studies on the strength of mortar added admixtures at different curing temperatures. Variations of curing temperature to. test compressive strength, tensil strength and bending strength were $20^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$ and these results were summarized as follow : In strength of mortar added briquette ash, the compressive strength was increased: 1.58 percent, the tensile strength 0.96 percent, and the bending strength 1.26 percent compared with standard strength, by increasing one degree of celsius temperature. Also in strength of mortar added fly ash, the compressive strength increased on the average 1.3 percent, the tensile strength 0.99 percent, and the bending strength 1.18 percent at the above conditions. In case of using fly ash as admixture, maximum compressive strengths was attained at the level of 25 percent of fly ash, maximum tensile strength at the level of 20 percent of fly ash, and maximum bending strength at the level of 20 percent of fly ash. In case of using briquette ash, maximum compressive strength was attained maximum strength at 20 percent of the admixture, maximum tensile strength at the level of 15 to 20 percent of admixture and maximum bending strength at the level of 20 percent of admixture. Although addition of briquette ash was less effective in increasing the strength compared with the addition of fly ash, briquette ash might be used as one of admixtures because the control of curing temperature might affect in getting the required practical strength.

  • PDF

Briquetting of Waste Silicon Carbide Obtained from Silicon Wafer Sludges (실리콘 wafer sludge로부터 얻어진 SiC의 단광화 기술)

  • Koo, Seong Mo;Yoon, Su Jong;Kim, Hye Sung
    • Journal of Powder Materials
    • /
    • v.23 no.1
    • /
    • pp.43-48
    • /
    • 2016
  • Waste SiC powders obtained from silicon wafer sludge have very low density and a narrow particle size distribution of $10-20{\mu}m$. A scarce yield of C and Si is expected when SiC powders are incorporated into the Fe melt without briquetting. Here, the briquetting variables of the SiC powders are studied as a function of the sintering temperature, pressure, and type and contents of the binders to improve the yield. It is experimentally confirmed that Si and C from the sintered briquette can be incorporated effectively into the Fe melt when the waste SiC powders milled for 30 min with 20 wt.% Fe binder are sintered at $1100^{\circ}C$ upon compaction using a pressure of 250 MPa. XRF-WDS analysis shows that an yield of about 90% is obtained when the SiC briquette is kept in the Fe melt at $1650^{\circ}C$ for more than 1 h.

Study on the Reaction Behavior of Self-reducing TiO2 Briquette (자기 환원성 TiO2 단광의 반응특성에 관한 연구)

  • Baek, S.J.;Shin, D.Y.;Min, J.W.;Choi, S.O.;Yun, D.J.;You, B.D.
    • Transactions of Materials Processing
    • /
    • v.15 no.8 s.89
    • /
    • pp.615-620
    • /
    • 2006
  • The reduction behavior of $TiO_{2}$ in Al and Al/CaSi containing self-reducing $TiO_{2}$ briquettes(SRTB) was investigated. The maximum yield of Ti was expected with the slag composition of 45-55%CaO in the $CaO-Al_{2}O_{3}$ system. When $CaCO_{3}$ was used as a flux, the oxidation loss of reducing agent by $CO_{2}$ should be compensated, and therefore it leads to excessive requirement of the reducing agent. By using Al and CaSi mixture as a reducing agent of $TiO_{2}$, the reaction products both oxide and metal could be liquefied, and separated effectively with each other. As a result, the yield of Ti increases remarkably. The optimum mixing ratio of CaSi to Al is 78%CaSi-22%Al.

A Stochastic Study for the Emergency Treatment of Carbon Monoxide Poisoning in Korea (일산화탄소중독(一酸化炭素中毒)의 진료대책(診療對策) 수립(樹立)을 위한 추계학적(推計學的) 연구(硏究))

  • Kim, Yong-Ik;Yun, Dork-Ro;Shin, Young-Soo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.135-152
    • /
    • 1983
  • Emergency medical service is an important part of the health care delivery system, and the optimal allocation of resources and their efficient utilization are essentially demanded. Since these conditions are the prerequisite to prompt treatment which, in turn, will be crucial for life saving and in reducing the undesirable sequelae of the event. This study, taking the hyperbaric chamber for carbon monoxide poisoning as an example, is to develop a stochastic approach for solving the problems of optimal allocation of such emergency medical facility in Korea. The hyperbaric chamber, in Korea, is used almost exclusively for the treatment of acute carbon monoxide poisoning, most of which occur at home, since the coal briquette is used as domestic fuel by 69.6 per cent of the Korean population. The annual incidence rate of the comatous and fatal carbon monoxide poisoning is estimated at 45.5 per 10,000 of coal briquette-using population. It offers a serious public health problem and occupies a large portion of the emergency outpatients, especially in the winter season. The requirement of hyperbaric chambers can be calculated by setting the level of the annual queueing rate, which is here defined as the proportion of the annual number of the queued patients among the annual number of the total patients. The rate is determined by the size of the coal briquette-using population which generate a certain number of carbon monoxide poisoning patients in terms of the annual incidence rate, and the number of hyperbaric chambers per hospital to which the patients are sent, assuming that there is no referral of the patients among hospitals. The queueing occurs due to the conflicting events of the 'arrival' of the patients and the 'service' of the hyperbaric chambers. Here, we can assume that the length of the service time of hyperbaric chambers is fixed at sixty minutes, and the service discipline is based on 'first come, first served'. The arrival pattern of the carbon monoxide poisoning is relatively unique, because it usually occurs while the people are in bed. Diurnal variation of the carbon monoxide poisoning can hardly be formulated mathematically, so empirical cumulative distribution of the probability of the hourly arrival of the patients was used for Monte Carlo simulation to calculate the probability of queueing by the number of the patients per day, for the cases of one, two or three hyperbaric chambers assumed to be available per hospital. Incidence of the carbon monoxide poisoning also has strong seasonal variation, because of the four distinctive seasons in Korea. So the number of the patients per day could not be assumed to be distributed according to the Poisson distribution. Testing the fitness of various distributions of rare event, it turned out to be that the daily distribution of the carbon monoxide poisoning fits well to the Polya-Eggenberger distribution. With this model, we could forecast the number of the poisonings per day by the size of the coal-briquette using population. By combining the probability of queueing by the number of patients per day, and the probability of the number of patients per day in a year, we can estimate the number of the queued patients and the number of the patients in a year by the number of hyperbaric chamber per hospital and by the size of coal briquette-using population. Setting 5 per cent as the annual queueing rate, the required number of hyperbaric chambers was calculated for each province and for the whole country, in the cases of 25, 50, 75 and 100 per cent of the treatment rate which stand for the rate of the patients treated by hyperbaric chamber among the patients who are to be treated. Findings of the study were as follows. 1. Probability of the number of patients per day follows Polya-Eggenberger distribution. $$P(X=\gamma)=\frac{\Pi\limits_{k=1}^\gamma[m+(K-1)\times10.86]}{\gamma!}\times11.86^{-{(\frac{m}{10.86}+\gamma)}}$$ when$${\gamma}=1,2,...,n$$$$P(X=0)=11.86^{-(m/10.86)}$$ when $${\gamma}=0$$ Hourly arrival pattern of the patients turned out to be bimodal, the large peak was observed in $7 : 00{\sim}8 : 00$ a.m., and the small peak in $11 : 00{\sim}12 : 00$ p.m. 2. In the cases of only one or two hyperbaric chambers installed per hospital, the annual queueing rate will be at the level of more than 5 per cent. Only in case of three chambers, however, the rate will reach 5 per cent when the average number of the patients per day is 0.481. 3. According to the results above, a hospital equipped with three hyperbaric chambers will be able to serve 166,485, 83,242, 55,495 and 41,620 of population, when the treatmet rate are 25, 50, 75 and 100 per cent. 4. The required number of hyperbaric chambers are estimated at 483, 963, 1,441 and 1,923 when the treatment rate are taken as 25, 50, 75 and 100 per cent. Therefore, the shortage are respectively turned out to be 312, 791. 1,270 and 1,752. The author believes that the methodology developed in this study will also be applicable to the problems of resource allocation for the other kinds of the emergency medical facilities.

  • PDF

Influence of Environmental Exposures on Patients with Chronic Obstructive Pulmonary Disease in Korea

  • Hong, Yoonki;Lim, Myoung Nam;Kim, Woo Jin;Rhee, Chin Kook;Yoo, Kwang Ha;Lee, Ji-Hyun;Yoon, Ho Il;Kim, Tae-Hyung;Lee, Jin Hwa;Lim, Seong Yong;Lee, Sang Do;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.5
    • /
    • pp.226-232
    • /
    • 2014
  • Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation and results from environmental factors and genetic factors. Although cigarette smoking is a major risk factor, other environmental exposures can influence COPD. The purpose of this study is to investigate the clinical characteristics of COPD according to the history of environmental exposure. Methods: The study population comprised of 347 subjects with COPD who were recruited from the pulmonary clinics of 14 hospitals within the Korean Obstructive Lung Disease Study Group. We classified environmental exposures according to history of living near factory, and direct exposure history to firewood or briquette. According to living environmental exposures, we compared the frequency of respiratory symptoms, pulmonary function, quality of life, exercise capacity, and computed tomography phenotypes. Results: Thirty-one subjects (8.9%) had history of living near factory, 271 (78.3%) had exposure history to briquette, and 184 (53.3%) had exposure history to firewood. Patients with history of living near a factory had a significantly longer duration of sputum, while patients with exposure to firewood tended to have lower forced expiratory volume in one second, and patients with exposure to briquette tended to have lower six minute walk distance. Conclusion: COPD subjects with the history of living near factory had more frequent respiratory symptoms such as sputum. Our data suggest that environmental exposure may influence clinical phenotype of COPD.

Recent Epidemiologic Features of Carbon Monoxide Poisoning in Korea: A Single Center Retrospective Cohort Study (최근 국내 일산화탄소 중독의 역학적 특징: 일개 응급의료센터의 후향적 코호트 연구)

  • Choi, Byung Ho;Jeon, Jin;Ryoo, Seung Mok;Seo, Dong Woo;Kim, Won Young;Oh, Bum Jin;Lim, Kyoung Soo;Sohn, Chang Hwa
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.10 no.2
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The aim of this study was to describe the epidemiologic characteristics of adult patients with carbon monoxide poisoning who presented to the emergency department in recent years. Methods: This was a retrospective cohort study on adult consecutive patients with carbon monoxide (CO) poisoning who presented to the emergency department of a tertiary care university-affiliated hospital from January 1, 2008 to December 31, 2011. Results: A total of 91 patients were included in this study; there were 56(61.5%) unintentional and 35(38.5%) intentional poisonings. For the unintentional CO poisonings, the principal sources of exposure to CO were fire (39.3%), charcoal (17.9%), briquette charcoal (7.1%), wood burning boiler (7.1%), gas boiler (5.4%), automobile heater (3.6%), briquette boiler (3.6%), firewood (3.6%), and other items (12.5%). For the intentional CO poisonings, the sources were ignition charcoal (60.0%), briquette (31.4%), charcoal (5.7%) and butane gas (2.9%). For the unintentional CO poisonings, the places of poisoning were the home (58.9%), workplace (10.7%), public accommodation (8.9%), tent (8.9%), automobile (3.6%) and parking place (1.8%). For the intentional CO poisonings, the places of poisoning were the home (77.1%), public accommodation (11.4%) and automobile (11.4%). The proportion of intentional CO poisonings among total poisonings has increased significantly in recent years; 0.0% in 2008, 3.3% in 2009, 5.5% in 2010, and 29.7% in 2011. Conclusion: This study showed that in recent years in Korea, the source of CO has diversified broadly and intentional CO poisonings from burning ignition charcoal or briquettes has increased. Prevention efforts should consider these factors.

  • PDF