• Title/Summary/Keyword: breath-by-breath

Search Result 484, Processing Time 0.026 seconds

The Improvement of the Balance and Breath Abilities for Mental Retardation by Sensory Integrative Intervention: Single Subject Research (지적장애 아동의 균형과 호흡 기능 향상을 위한 감각통합치료: 개별 실험 연구)

  • Kim, Kyeong-Mi;Hong, Eun-Kyoung
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.9 no.1
    • /
    • pp.33-44
    • /
    • 2011
  • Objective : Sensory integration is the organization for sensation for use. The purpose of this study is to carry out the sensory integrative intervention for the mental retardation with child and to examine change of child's balance and breath abilities. Methods : The study performed from 25 May to 13 Autumn, 2009. The design is AB design(baseline 3sessions, intervention 21sessions) of single-subject research design. We carried out the sensory integrative intervention(3 sessions per week) for baseline period and the sensory integrative intervention(3 sessions per week) with sensory diet every day for intervention period. Results : The results of the sensory integrative intervention with sensory diet had positive effects for child's breathe and balance. Conclusion : The occupational therapists recognize the effects of the sensory integrative intervention with sensory diet and need to recommend for the family of child with disability.

  • PDF

Liver dose reduction by deep inspiration breath hold technique in right-sided breast irradiation

  • Haji, Gunel;Nabizade, Ulviye;Kazimov, Kamal;Guliyeva, Naile;Isayev, Isa
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.254-258
    • /
    • 2019
  • Purpose: Deep inspiration breath hold (DIBH) is a well-established technique that enables efficient cardiac sparing in patients with left-sided breast cancer. The aim of the current study was to determine if DIBH is effective for reducing radiation exposure of of liver and other organs at risk in right breast radiotherapy (RT). Materials and Methods: Twenty patients with right-sided breast cancer were enrolled in this study. Three-dimensional conformal RT plans were generated for each patient, with two different computed tomography scans of free breathing (FB) and DIBH. Nodes were contoured according to the Radiation Therapy Oncology Group contouring guidelines. Dose-volume histograms for the target volume coverage and organs at risk were evaluated and analyzed. Results: DIBH plans showed significant reduction in mean liver dose (5.59 ± 2.07 Gy vs. 2.54 ± 1.40 Gy; p = 0.0003), V20Gy (148.38 ± 73.05 vs. 64.19 ± 51.07 mL; p = 0.0003) and V10Gy (195.34 ± 93.57 vs. 89.81 ± 57.28 mL; p = 0.0003) volumes compared with FB plans. Right lung doses were also significantly reduced in DIBH plans. Heart and left lung doses showed small but statistically significant improvement with application of the DIBH technique. Conclusion: We report that the use of DIBH for right-sided breast cancer significantly reduces the radiation doses to the liver, lungs, and heart.

CHLOROFORM BODY BURDEN FROM BATHING (목욕으로 인한 클로로포름의 인체부담)

  • 조완근;황영미
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.277-284
    • /
    • 1995
  • There has been an increased awareness of the need to confirm the chloroform exposure associated with using chlorinated household water. Ten of a 30-minute tub bath were normally taken by two volunteers in a bathroom of an apartment. Chloroform concentrations were measured in bathing water and bathroom air, and exhaled breath of the subjects prior to and after bathing. Bathing using chlorinated tap water resulted in a chloroform exposure and caused a body burden. Based on the difference of chloroform concentrations between breath samples collected prior to and after bathing, the chloroform body burden from a 30-minute bath was estimated to be about 8 to 26 folds higher than that prior to the bath. The mean water and bathroom air chloroform concentrations measured to evaluate the body burden were $9.4\mu\textrm{g}/l$ and TEX>$14.9\mu\textrm{g}/m^3$, respectively. The chloroform level of the bathroom air was 각 to 130 times higher than that of the living-room air. The relationship between the bathroom air and the corresponding breath chloroform concentrations were significant with p=0.03 and $R^2=0.47$.

  • PDF

CHLOROFORM BODY BURDEN FROM BATHING (목욕으로 인한 클로로포름의 인체부담)

  • Jo, Wan-Kuen;Hwang, Young-Mee
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.125-125
    • /
    • 1995
  • There has been an increased awareness of the need to confirm the chloroform exposure associated with using chlorinated household water. Ten of a 30-minute tub bath were normally taken by two volunteers in a bathroom of an apartment. Chloroform concentrations were measured in bathing water and bathroom air, and exhaled breath of the subjects prior to and after bathing. Bathing using chlorinated tap water resulted in a chloroform exposure and caused a body burden. Based on the difference of chloroform concentrations between breath samples collected prior to and after bathing, the chloroform body burden from a 30-minute bath was estimated to be about 8 to 26 folds higher than that prior to the bath. The mean water and bathroom air chloroform concentrations measured to evaluate the body burden were $9.4\mu\textrm{g}/l$ and TEX>$14.9\mu\textrm{g}/m^3$, respectively. The chloroform level of the bathroom air was 각 to 130 times higher than that of the living-room air. The relationship between the bathroom air and the corresponding breath chloroform concentrations were significant with p=0.03 and $R^2=0.47$.

Use of Gas-Sensor Array Technology in Lung Cancer Diagnosis

  • Kim, Young Jun;Yu, Han Young;Baek, In-Bok;Ahn, Chang-Geun;Lee, Bong Kuk;Kim, Yarkyeon;Yoon, Yong Sun;Lim, Ji Eun;Lee, Byeong-Jun;Jang, Won Ik;Park, Jeong Ho;Choi, Chang-Auck
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.249-255
    • /
    • 2013
  • Gas-sensor array technology, which has been much utilized in the field of food technology by the name of 'electronic nose' is drawing attention in diagnosing lung cancer based on the analysis of the exhaled human breath. Much understanding has been accomplished about the composition of the volatile organic compounds (VOCs) of the human exhaled breath, in spite of some variations depending on research groups due mainly to lack of the standardization of the sensing procedures. Since VOCs may be produced during the process of cellular metabolism, difference in the cellular metabolism between healthy cells and lung cancer cells are expected to be reflected on the composition variation of the exhaled VOCs. Several studies have attempted to apply the gas-sensor array technology to lung cancer analysis using many different types of sensors including metal oxide, carbon black-polymer composite, surface acoustic wave, and gold nanoparticles. In this mini-review VOC as biomarkers, sensor array technology and application of the array technology for the diagnosis of cancer disease have been described.

Convergence Related Factors of Subjective Oral Care Awareness in Wonju city W High School Students (원주시 W고등학생의 주관적 구강관리인식과 융복합적 요인에 대한 연관성)

  • Cho, Min-Jin;Choi, Eun-Mi;Kim, Young-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.127-135
    • /
    • 2018
  • The purpose of this study is to investigate the convergence related factors of subjective oral care awareness in high school students. 218 data were analyzed; subjective oral care awareness were $3.59{\pm}0.44$, significantly affected by religion, intake of fast food and carbonated drink(p<.05). According to analysis, students who stated reasons for halitosis as 'Tooth brushing to eliminate bad breath' and 'Friends bad breath are discomfort' showed high subjective oral care awareness, however, it was low when students were not aware of their bad breath. Therefore, increasing tooth brushing frequency and reducing the intake of carbonated drink and junk food are needed to boost subjective oral care awareness. Also, it is considered that educational contents and materials for factors which affects subjective oral care awareness should be developed for high school student's Oral health education class.

Synthesis of Ce-doped In2O3 nanoparticles via a microwave-assisted hydrothermal pathway and their application as an ultrafast breath acetone sensor

  • Byeong-Hun Yu;Sung Do Yun;Chan Woong Na;Ji-Wook Yoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.6
    • /
    • pp.393-400
    • /
    • 2023
  • Acetone, a metabolite detected from the exhaled breath of people doing a diet, can be used for non-invasive monitoring of diet efficiency. Thus, gas sensors with rapid response and recovery characteristics to acetone need to be developed. Herein, we report ultrafast acetone sensors using Ce-doped In2O3 nanoparticles prepared by the one-pot microwave-assisted hydrothermal method. The pure In2O3 sensor shows a high response and fast response time (τres = 6 s) upon exposure to 2 ppm acetone at 300 ℃, while exhibiting a relatively sluggish recovery speed (τrecov = 1129 s). When 20 wt% Ce is doped, the τrecov of the sensor significantly decreased to 45 s withholding the fast-responding characteristic (τres = 6 s). In addition, the acetone response (resistance ratio, S) of the sensor is as high as 5.8, sufficiently high to detect breath acetone. Moreover, the sensor shows similar acetone sensing characteristics even under a highly humid condition (relative humidity of 60%) in terms of τres (6 s), τrecov (47 s), and S (4.7), demonstrating its high potential in real applications. The excellent acetone sensing characteristics of Ce-doped In2O3 nanoparticles are discussed in terms of their size, composition, phase, and oxygen adsorption on the sensing surface.

Sensor Mat using POF for Medical Application (의료용 플라스틱 광섬유 센서 매트)

  • Choi, Kyoo-Nam
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.74-78
    • /
    • 2007
  • Novel concept of sensor mat and its signal processing method is proposed for patient monitoring in medical application. Proposed sensor mat structure has sensing inner layer which has cross-linked arrangement using plastic optical fiber(POF). Large core diameter of plastic optical fiber behaved as band pass filter by averaging the noise component caused by unwanted environmental factors. Signal processor followed by sensor output added noise immune performance by filtering out unwanted component. Fail-proof patient breath monitoring scheme was realized by using intelligent decision algorithm. Unlike the conventional approach by using mechanical sensor, which have high sensitivity both to signal and to environmental noise, our approach provided reliable breath motion detection.

A Study on the Effects of the Breath Efficiency & Lung Capacity Improvement Using Recorder Playing Focused on Breath Training (리코더 연주를 통한 뇌졸중 노력성 폐활량과 호흡 효율성 향상 연구)

  • Choi, Sung Joo
    • Journal of Music and Human Behavior
    • /
    • v.4 no.1
    • /
    • pp.31-46
    • /
    • 2007
  • The purpose of the study was to improve the efficiency of Breath & Forced Vital Capacity(FVC) of Stroke Patients Using Record Playing Focused on Breath Training. The Training of Forced Vital Capacity(FVC) is focused on trunk muscles reinforce for Breathing. So the study tried to play Recorder for reinforcing FVC. The play included the two parts. One was for solo play, the other was play in concert base on solo play using Korea country song, Arirang. The Recorder play used abdominal breath, Pursed-lip & Paced methods. The course of play included Long Tone, Staccato, Crescendo, Decrescendo and throughout the course we tried to improve the efficiency & Quantity of breathe. Experiment performed at Social welfare institute for the old. They played & checked FVC, $FEV_1$, $FEV_1/FVC$ before & after breathe 19 times for 6 weeks using Spirovit SP-1, Schiller. After experiment we performed statical process(p<0.05) using statical Package software. The findings were as follows: Analysis for Experiment showed the numerical Value of increasing Of FVC, $FEV_1$, $FEV_1/FVC$. Increasing Percentage of Measured/Predicted FVC, $FEV_1$ (or calculated based on theory) ration was 25%, 13% and Quantity of FVC, $FEV_1$ 35%, 40%. Also $FEV_1/FVC$ Ratio(showed efficiency of breathe) raised 13%. And experiment data was confirmed by statical process. The experiment data was valuable under p<0.05. In Conclusion we think the results of experiment showed the efficiency of Music therapy for Breathe(FVC, $FEV_1$, $FEV_1/FVC$) reinforce.

  • PDF

Comparison of the Diagnostic Performance of $^{14}C$-urea Breath Test According to Counting Method for the Diagnosis of Helicobacter pylori Infection (Helicobacter pylori 감염 진단 시 $^{14}C$-요소호기검사의 계수측정 방법에 따른 진단성능 비교)

  • Kim, Min-Woo;Lim, Seok-Tae;Lee, Seung-Ok;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.21-25
    • /
    • 2005
  • Purpose: $^{14}C$-urea breath test (UBT) is a non-invasive and reliable method for the diagnosis of Helicobacter pylori (HP) infection. In this study, we evaluated the diagnostic performance of a new and rapid $^{14}C$-UBT (Heliprobe method), which was equipped with $Geiger-M\ddot{u}ller$ counter and compared the results with those obtained by using the conventional method. Materials and Methods: Forty-nine patients with dyspepsia underwent gastroduodenoscopy and $^{14}C$-UBT. A 37 KBq $^{14}C$-urea capsule was administered to patients and breath samples were collected. In Heliprobe method, patients exhaled into a Hellprobe BreathCard for 10 min. And then the activities of the BreathCard were countered using Heliprobe analyzer. In the conventional method, results were countered using liquid scintillation counter. During gastroduodenoscopy, 18 of 49 patients were underwent biopsies. According to these histologic results, we evaluated the diagnostic performance of two different methods and compared them. Also we evaluated the concordant and disconcordant rates between them. Results: In all 49 patients, concordant rate of both conventional and Heliprobe methods was 98% (48/49) and the discordant rate was 2% (1/49). Thirteen of 18 patients to whom biopsies were applied, were found to be HP positive on histologic results. And both Heliprobe method and conventional method classified 13 of 13 HP-positive patients and 5 of 5 HP-negative patients correctly (sensitivity 100%, specificity 100%, accuracy 100%). Conclusion: The Heliprobe method demonstrated the same diagnostic performance compared with the conventional method and was a simpler and more rapid technique.