• 제목/요약/키워드: breakdown point

검색결과 168건 처리시간 0.025초

MPPF 커패시터의 전기적, 열적 열화시 소체의 화학적특성에 관한 연구 (A Study on Chemical Characteristic of Electrically and Thermally Treated MPPF Capacitor Elements)

  • 구교선;송현석;이동준;곽희로;송길목
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.227-230
    • /
    • 2001
  • This paper divides the factors of an accident into two parts, that are electrical deterioration and thermal deterioration, to analyze a characteristic of the factor of an accident which can break out in the capacitor of metal vaporized polypropylene film. For the purpose of creating capacitor which is caused by electric deterioration, we applied DC overvoltage, induced self-healing and breakdown from element. We applied gradual heat to get an element which is cause by thermal deterioration. The chemical structure of the shape and surface is analyzed by thermogravimetric analyzer (TGA), Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectrometer(FT-IR). As a result, the peak of methylene group came out, in case of electrical deterioration, as observing the self-healing point. However, the peak is disappeared in the heat treated element by 500[$^{\circ}C$], and the peak of carbonyl group which has C=O came out in case of thermal deterioration.

  • PDF

Negative Exponential Disparity Based Deviance and Goodness-of-fit Tests for Continuous Models: Distributions, Efficiency and Robustness

  • Jeong, Dong-Bin;Sahadeb Sarkar
    • Journal of the Korean Statistical Society
    • /
    • 제30권1호
    • /
    • pp.41-61
    • /
    • 2001
  • The minimum negative exponential disparity estimator(MNEDE), introduced by Lindsay(1994), is an excellenet competitor to the minimum Hellinger distance estimator(Beran 1977) as a robust and yet efficient alternative to the maximum likelihood estimator in parametric models. In this paper we define the negative exponential deviance test(NEDT) as an analog of the likelihood ratio test(LRT), and show that the NEDT is asymptotically equivalent to he LRT at the model and under a sequence of contiguous alternatives. We establish that the asymptotic strong breakdown point for a class of minimum disparity estimators, containing the MNEDE, is at least 1/2 in continuous models. This result leads us to anticipate robustness of the NEDT under data contamination, and we demonstrate it empirically. In fact, in the simulation settings considered here the empirical level of the NEDT show more stability than the Hellinger deviance test(Simpson 1989). The NEDT is illustrated through an example data set. We also define a goodness-of-fit statistic to assess adequacy of a specified parametric model, and establish its asymptotic normality under the null hypothesis.

  • PDF

경계요소법을 이용한 전력케이블 접속부의 전계해석 (Electric Field Analysis of Power Cable Joint Point using Boundary Element Method)

  • 조경순
    • 한국컴퓨터산업학회논문지
    • /
    • 제4권4호
    • /
    • pp.579-588
    • /
    • 2003
  • 지중전선로에 있어서 케이블을 연결하는 중간 접속재에 발생하는 전계 집중, 각종 불순물의 침투 및 케이블 절연층의 손상은 궁극적으로 열화 및 절연파괴를 야기하게 되어 케이블의 수명을 단축시키고 있다. 본 연구에서는 경계요소법을 이용하여 초고압 케이블 절연재료로 널리 사용되고 있는 가교폴리에틸렌과 접속재 키트의 절연층으로 사용되고 있는 EPDM의 전계분포를 시뮬레이션 하였다. 시료는 두께 1[mm]로 3장을 중첩한 것으로 모델링하여 컴퓨터 시뮬레이션을 하였다. 전계해석 결과 보이드 내부의 defect는 silicone oil에 의해 전계집중을 약화시킴을 확인하였고, XLPB보다 EPDM의 전계분포가 낮게 유지됨을 확인하였다.

  • PDF

부분방전 패턴을 이용한 가교폴리에틸렌에서의 트리성장에 관한 연구 (The Study on tree growth in XLPE using PD patterns)

  • 강대용;오광영;신창면;박명섭;조규복;황보승;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.941-943
    • /
    • 1998
  • Exploitation of equipment with cross linked polyethylene (XLPE) insulation requires its condition monitoring and diagnostic. Traditionally diagnostics of insulation is carried out by means of partial discharge detection. Many researchers have developed a lot of methods to identify the defect by the PD form. However, such identification of a defect, for example, void, inclusion or treeing, does not say about its danger from a point of view of full insulation gap breakdown and insulation construction failure. The information about the form and size of formed upon high voltage treeing is necessary for prediction of the remained resource of XLPE insulation. For this purpose we carry out experimental research for determination of the dependencies between PD characteristics in XLPE upon time and three dimension PD patterns of corresponding treeing. The investigations were carried out by means of electrical measurement of PD current and simultaneous optical recording of treeing image. Test results show that the PD patterns can be applied for detecting tree growth well.

  • PDF

PLANE COURTESY: HOW PASSENGER ATTITUDES ON BOARD CAN DECREASE THE AIR RAGE PHENOMENON

  • Hunter, Joyce A
    • 한국항공우주법학회:학술대회논문집
    • /
    • 한국항공우주법학회 2008년도 제40회 국제학술발표대회
    • /
    • pp.153-161
    • /
    • 2008
  • What was once known as common courtesy is rapidly disappearing in the air travel industry, and the violent behavior known as air rage is a constant threat. Once sought after by other industries for advice because of its expertise in customer service, the air travel industry has now slipped to the lowest rungs of companies with unhappy customers. As airlines cut corners in order to avoid bankruptcy, passengers' patience is tested by the stress of flight delays, crowded airports and close packed seating on airplanes. This article examines the situation, strategies used by passengers and ways the airline industry might better inspire courteous behavior in passengers. A cultural expectation of entitlement and competitiveness for limited resources has led to a breakdown in civilized behavior throughout society, both in the United States and internationally. Air travelers faced with rude and intrusive behavior from others on the flight are beginning to find their own ways of coping, such as high quality headphones to block offensive noises, and mechanical devices to keep the seat in front from reclining to the point where it hits their knees. The most potentially effective remedies will come from airlines that enlist cooperation by offering effective passenger education and possibly even incentives. Acceptable airline behaviors need to be plainly defined and stressed for passengers, both before boarding and onboard. In this paper, some methods are suggested to motivate passengers and to inspire courteous behavior.

  • PDF

345kV 혼합송전선로에서 재폐로가 절연설계에 미치는 영향 (Effects of Reclosing for Insulation Coordination in 345kV Combined Transmission Lines)

  • 이종범;정채균;임광식;강지원
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.847-853
    • /
    • 2010
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with XLPE power cable. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as length ratio of power cable section, arrestor, inserting resistance, charging rate, grounding resistance, etc.. On the other hand sheath voltage on IJ(Insulated Joint) is analyzed to check dangerous condition on cable cover. Analysis is performed by EMTP/ATP. Analysis results show that reclosing can be operated as the single line-to-ground fault occurs on overhead line in 345kV combined transmission line, if the inserting resistance is considered before the operation of main circuit breaker.

홀 센서를 이용한 자동연료공급 제어장치에 관한 연구 (A Study on the Auto Fuel Feeding Control System using Hall Sensor)

  • 김규성;조명현
    • 전자공학회논문지 IE
    • /
    • 제43권3호
    • /
    • pp.34-40
    • /
    • 2006
  • 일반적으로 유체나 연료 공급 장치는 모터를 제어하기 위한 특별한 센서가 필요하고, 센서를 부착하기 위한 보조 장치와 부착하기 위한 공간이 필요하다. 또한 신호선 및 기타 배선 등이 필요하여 어려운 점이 따르게 된다. 본 논문에서는, 불편함과 문제점을 해결하기 위하여 홀센서를 이용한 제어시스템을 제안하였고, 시스템의 제어원리는 모터 동작 단계에 따라 전류흐름에 차이가 발생한다는 것을 이용하였다. 또한 제어 시스템이 우수할 뿐만 아니라 센서 설치에 따른 고장을 줄일 수 있었고, 재료비 및 인건비를 절감할 수 있다. Auto-Pumping 시스템은 Soft-Ware적응용을 통해 모든 유체 공급 시스템에 적용할 수 있으며, 차후에 시스템을 이용한 여러 종류의 장치를 개발할 수 있으리라 본다.

서울시 임차가계의 임대료부담과 가계경제문제지각 (A Study on Rent burden and Family Economic Problem Perception - Focus on Seoul City's Rental Households -)

  • 이기춘;배순영
    • 가정과삶의질연구
    • /
    • 제9권1호통권17호
    • /
    • pp.241-257
    • /
    • 1991
  • The objectives of this study are : to measure the level of rent burden. to examine the independent influences of the variables related to rent burden. to measure the level of family economic problem perception. to examine the differences in the level of family economic problem perception due to rent burden, household characteristics, housing characteristics and rent incresing. For these purpose, a survey is conducted using questionaires. The data used in this study included 369 renters living in Seoul. Statistics uses for data analysis were Frequency Distribution. Percentile, men, Pearson's Correlation, Partial Correlation, One-way ANOVA, Breakdown and Multiple Regression Analysis. Major findings are as follows : The average score of rent burden was 35.87, Therefore rent burden of large cities, rental households is very heavy. Family income, housing facility quality, rent type, and rent incresing have independent influences on rent burden. The average of family economic problem perception is above the mid-point of the scale. The level of family economic problem perception differs due to rent burden, family income, family life cycle, family size, occupation of household head, education leval of household head and homemaker, rent type, housing type, housing size, housing facility quality and rent increases. If the level of rent burden is below 25, family economic problem perception is adequate.

  • PDF

154kV 혼합송전선로 재폐로 결정에 관한 연구 (A Study on Reclosing Decision on 154kV Combined Transmission Lines)

  • 정채균;박흥석;강지원;이종범
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1761-1769
    • /
    • 2010
  • This paper describes switching surge analysis on reclosing decision in 154kV combined transmission line with power cables. Reclosing should be operated in combined transmission line based on the technical evaluation because of insulation problem of power cable section. If the surge strikes on power cable, the breakdown can occur at week point of cable insulation. Therefore the detailed analysis is required by considering several conditions such as length ratio of power cable, arrester, fault resistance, charging rate and grounding resistance, etc.. In addition, sheath voltage on IJ(Insulated Joint) is analyzed to confirm the protective level. Simulation is performed by EMTP/ATP. Analysis results show that reclosing can be operated without any special problem by the single line-to-ground fault with fault resistance of $1\Omega$ to $50\Omega$ occurred at the overhead transmission section in 154kV combined transmission lines and trap charge of 100% and 110%.

Electrical Characteristics of Enhancement-Mode n-Channel Vertical GaN MOSFETs and the Effects of Sidewall Slope

  • Kim, Sung Yoon;Seo, Jae Hwa;Yoon, Young Jun;Kim, Jin Su;Cho, Seongjae;Lee, Jung-Hee;Kang, In Man
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1131-1137
    • /
    • 2015
  • Gallium nitride (GaN) is a promising material for next-generation high-power applications due to its wide bandgap, high breakdown field, high electron mobility, and good thermal conductivity. From a structure point of view, the vertical device is more suitable to high-power applications than planar devices because of its area effectiveness. However, it is challenging to obtain a completely upright vertical structure due to inevitable sidewall slope in anisotropic etching of GaN. In this letter, we design and analyze the enhancement-mode n-channel vertical GaN MOSFET with variation of sidewall gate angle by two-dimensional (2D) technology computer-aided design (TCAD) simulations. As the sidewall slope gets closer to right angle, the device performances are improved since a gradual slope provides a leakage current path through the bulk region.