• Title/Summary/Keyword: branch-line hybrid coupler

Search Result 28, Processing Time 0.026 seconds

Balanced Amplifier using Three-Arm Branch $90^{\circ}$ Hybrid Coupler (Three-Arm Branch $90^{\circ}$ Hybrid Coupler를 이용한 평형증폭기 설계에 대한 연구)

  • Kim, Seon-Sook;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.2 s.344
    • /
    • pp.76-80
    • /
    • 2006
  • In this paper, broadband balanced amplifier has been realized with Three-Arm Branch $90^{\circ}$ Hybrid Coupler at center frequency 2GHz. $90^{\circ}$ Hybrid Branch-Line Coupler has been compared with Three-Arm Branch $90^{\circ}$ Hybrid Coupler. The bandwidth VSWR and gain or proposed amplifier have been 480MHz, 1.06 and 15.47dB, respectively.

Performance Analysis of Improved Direct Conversion Six-port Phase Correlator (대역폭이 향상된 직접변환 Six-port 위상 상관기 성능분석)

  • Yu, Jae-Du;Kim, Young-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.91-94
    • /
    • 2007
  • In this paper, the six-port phase correlator using $90^{\circ}$ hybrid branch-line coupler and three-arm branch $90^{\circ}$ hybrid coupler were designed. The performances for two six-port phase correlators were analyzed by using ADS2003A tool. Three-arm six-port phase collerator provides more wide dynamic frequency range than that of six-port using the conventional hybrid coupler in range of circa five times. Six-port phase correlators were fabricated to evaluate the performance of two six-port phase correlators. The measured performances for two six-port phase correlators show the good accordance with the simulation data.

  • PDF

A New Asymmetric Branch Line Hybrid Coupler without Ground Contact Problem of DGS (접지 접촉 문제가 없는 새로운 DGS 비대칭 브랜치 라인 하이브리드 결합기)

  • Lim, Jong-Sik;Cha, Hyeon-Won;Jeong, Yong-Chae;Park, Ung-Hee;Ahn, Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1416-1421
    • /
    • 2008
  • A 10 dB branch line hybrid coupler included with defected ground structure (DGS) is proposed. In this contribution, a contact between the grounded metal housing and DGS is avoided, which has been a serious problem in applying DGS to high frequency circuits. An isolation between the metal housing and the DGS pattern is provided by inserting additional substrate between DGS and the metal package. Therefore, it is possible to design branch line hybrid couplers having highly asymmetric power dividing ratio using these DGS structure, which is demonstrated in this paper. The designed and fabricated branch line hybrid coupler using DGS is well packaged in a metal housing without touching the ground metal directly. The measurement is performed under realistic practical operating situations because it is packaged in a metal housing. The measured performances of the fabricated 10dB coupler shows a 1:9 asymmetric power dividing ratio at output ports, as predicted. In addition, the measured performances in terms of matching, isolation, and phase difference are in excellent agreement with the simulated characteristics.

Design of an extremely miniaturized branch-line coupler

  • Kang, In Ho;Li, Xi Qiang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.995-999
    • /
    • 2014
  • In this paper, a new size-reduction approach for branch-line coupler is introduced which uses parallel end-shorted coupled lines with lumped capacitors. The characteristic of the new design was analyzed using even-odd mode method, and simulated on HFSS before fabricated on the FR4 epoxy glass cloth copper-clad plat (CCL) PCB substrate at center frequency of 1 GHz. The electrical length of transmission line was reduced to 15 degrees, therefore the size of branch-line coupler was largely reduced approximately maintaining the same characteristic around the stable center frequency. The insertion loss of the branch-line coupler filter was -4.39 dB. The size of the overall hybrid is $20mm{\times}20mm$. Measurements results were well agreed with the simulated ones.

A Study on the Microwave Transmission Line frequency Discriminator Using Branch-Line Hybrid 3dB coupler (Branch-LIne 하이브리드 3dB 결합기를 이용한 마이크로파 전송선로 전파수 판별기에 관한 연구)

  • 조홍구;이충웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.6
    • /
    • pp.97-102
    • /
    • 1985
  • A new microwave transmission line frequency discriminator in MIC is described, which is composed of a branch-line hybrid 3dB coupler, a λ/2-short stub and a λ/4-opcn stub. It is experimentally verified that the discriminator is linear in a 400 MHz bandwidth at center frequency 4.94 GHz and has return loss more than 15dB in that range.

  • PDF

RF Front-end Design of Direct Conversion Receiver using Six-Port (6-단자를 이용한 직접 변환 수신 전 처리부 설계)

  • Jang Myoung-shin;Kim Young-wan;Ko Nam-young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.7
    • /
    • pp.1534-1540
    • /
    • 2005
  • The direct conversion method is classified into the structure using the mixing technology and six-port scheme. In the view point of complexity and integration the direct conversion method using the six-port scheme is superior to that with mixing technology. Expecially, the six-port direct conversion technology provides the low power consumption and the broad-band characteristic. In this paper, the six-port direct conversion receiver with the branch-line coupler and the ring hybrid coupler is desisted respectively. The performances of the designed six-port schemes are analyzed and the six-port scheme with superior performance characteristics is proposed.

RF Front-end Design of Direct Conversion Receiver using Six-Port (6-단자를 이용한 직접 변환 수신 전 처리부 설계)

  • Jang, Myoung-Shin;Yang, Woo-Jin;Oh, Dae-Ho;Kim, Young-Wan;Ko, Nam-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.481-484
    • /
    • 2005
  • The direct conversion method is classified into the structure using the mixing technology and six-port scheme. In the view point of complexity and integration the direct conversion method using the six-port scheme is superior to that with mixing technology. Expecially, the six-port direct conversion technology provides the low power consumption and the broad-band characteristic. In this paper, the six-port direct conversion receiver with the branch-line coupler and the ring hybrid coupler is designed respectively. The performances of the designed six-port schemes are analyzed and the six-port scheme with superior performance characteristics is proposed.

  • PDF

Design and Performance Analysis of Wideband Six-port Phase correlator (대역폭이 향상된 Six-port 위상 상관기 설계 및 성능 분석)

  • Kim, Young-Wan;Yu, Jae-Du
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.3
    • /
    • pp.414-419
    • /
    • 2008
  • The six-port correlator is comprised of a power divider and three hybrid couplers. In this paper, the six-port phase correlator using three-arm branch $90^{\circ}$ hybrid coupler were designed with the center frequency of 11.85 GHz. The performances for the six-port phase correlator was analyzed by using ADS2003A tool. Three-arm six-port phase correlator provides more wide dynamic frequency range than that of six-port using the conventional hybrid coupler in range of circa five times, which is range of 10.8 to 12.3GHz (1.5 GHz). The phase errors among the output ports of the six-port phase correlator are below $5^{\circ}$. The six-port Phase correlator was fabricated to evaluate the Performance of the proposed six-port phase correlator. The measured performance of the six-port phase correlator shows the good accordance with the simulation data.

A New Dual Band Branch Line Hybrid Coupler with Arbitrary Power Division Ratio (임의의 분배비를 갖는 새로운 이중 대역 가지 선로 결합기)

  • Kim, Kwi-Soo;Gwon, Chil-Hyeun;Dorjsuren, Baatarkhuu;Lim, Jong-Sik;Ahn, Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.5
    • /
    • pp.444-449
    • /
    • 2009
  • This paper presents the design of a dual band branch line hybrid coupler(BLHC) with different power division ratios at two bands. In the proposed design, transmission lines of the BLHC are transformed to $\pi$-type equivalent circuits which represent different impedances and $\lambda/4$ electrical length at two frequency bands. In order to verify the proposed method, a dual band coupler with different power division ratios is designed for 0.9 GHz and 2 GHz applications. The desired power division ratios are 1:1 and 1:3 at the two operating frequency bands. The measured results show excellent performance with an insertion loss of less than 0.33 dB, a return loss of less than -18.07 dB, and good isolation characteristics.

Compact Hybrid Branch-line Couplers and Rat-Race Couplers with Periodic Stepped Stubs (주기적인 계단형 스터브를 갖는 소형화된 하이브리드 Branch-Line 결합기와 Rat-Race 결합기)

  • Lee Chang On;Kim Won-Ki;Kim Sang-Tae;Shin Chull-Chai
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.12
    • /
    • pp.115-124
    • /
    • 2004
  • In this paper, we introduce the advanced compact transmission line with periodic stepped stubs. They are more effective than normal stubs in ATL. The short stepped stubs loading of transmission line work as effective shunt capacitance and that was proved by equivalent circuit based on transmission line theory and quasi-static analysis. And the compact branch-line coupler and the compact rat-race coupler via proposed compact microstrip line were designed at 1.8 ㎓. They have 677 ㎟ and 913 ㎟, respectively, and they are 62% and 45% of normal design.