• Title/Summary/Keyword: brain structure

Search Result 407, Processing Time 0.023 seconds

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

Relationship between Alcohol Use Disorders Identification Test Fractional Anisotropy Value of Diffusion Tensor Image in Brain White Matter Region (알코올 선별 검사법(Alcohol Use Disorders Identification Test)과 뇌 백질 영역의 확산텐서 비등방도 계측 값의 관련성)

  • Lee, Chi Hyung;Kim, Gyeong Rip;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.575-583
    • /
    • 2022
  • Magnetic resonance diffusion tensor imaging (DTI) has revealed the disruption of brain white matter microstructure in normal aging and alcoholism undetectable with conventional structural MR imaging. we plan to analyze the FA measurements of the ROI of dangerous drinkers selected from Alcohol Use Disorders Identification Test (AUDIT) and Tract-Based Spatial Statics (TBSS) tool was used to extract FA values in the ROI from the image acquired through the pre-processing process. TBSS has a higher sensitivity of the FA value and MD value in the white matter than the brain gray matter, and has the advantage of quantitatively deriving the unlimited degree of brain nerve fibers, and more specialized in the brain white matter. We plan to analyze the fractional anisotropy (FA) measurement value for damage by selecting the center of the anatomical structure of the white matter region of the brain with high anisotropy among the brain neural networks that are particularly vulnerable to alcohol as the region of interest (ROI). In this study, we expected that alcohol causes damage to the brain white matter microstructure from FA value in various areas including both Choroid plexus. Especially, In the case of the moderate drunker, the mean value of FA in Lt, Rt. Choroid plexus was 0.2831 and 0.2872, whereas, in the case of the severe drunker, the mean value of FA was 0.1972 and 0.1936. We found that the higher the score on the AUDIT scale, the lower the FA value in ROI region of the brain white matter. Using the AUDIT scale, the guideline for the FA value of DTI can be presented, and it is possible to select a significant number of potentially severe drinkers. In other words, AUDIT was proved as useful tool in screening and discrimination of severe drunker through DTI.

A Tapered Slot Antenna with Asymmetric Corrugations for a Microwave Brain Imaging System (전자파 두뇌 영상장치용 비대칭형 Corrugated 테이퍼드 슬롯 안테나)

  • Lee, Juneseok;Park, Joongki;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.348-351
    • /
    • 2013
  • Recently, a brain imaging system with microwave devices has been proposed. The brain imaging system requires a small antenna which has ultra wide band(UWB) operating frequency bandwidth(0.5~2 GHz) and non-varying boresight of antenna over the frequency band. This paper proposes asymmetric corrugations on a tapered slot antenna (TSA) so that the size of the TSA is reduced by 14 % while 10 dB return loss bandwidth is satisfied over the operating frequency band from 0.5 GHz to 2 GHz. A miniaturized TSA with symmetric corrugations shows tilted boresight whilst frequency is getting lower; however, the proposed TSA with asymmetric corrugations maintains direction of boresight for different frequencies. This enhancements make an asymmetric corrugated TSA meet the requirement of the brain imaing system.

Moleculay Cloning of the cDNA Encoding the 16 kDa Subunit of V-ATPase in Rat Brain (흰쥐 뇌에서 발현되는 16 kDa Vacuolar (H$^{+}$)-ATPase의 유전자 클로닝)

  • Shin, Song-Woo;Yoo, Min
    • Biomedical Science Letters
    • /
    • v.6 no.3
    • /
    • pp.165-170
    • /
    • 2000
  • Vacuolar (H$^{+}$)-ATPase (V-ATPase) is an intracellular protein which consists of multiple subunits. It carries out acidification by pumping protons in the cell. This enzyme has also been found in the synaptic vesicles and may play an important role in the neurotransmission. We cloned cDNA fragments encoding the 16 kDa subunit of V-ATPase from the rat brain by RT-PCR and PCR using total RNA or recombinant phage DNA as templates. They contained the full coding sequences (468 bp) and one nucleotide at 3' region turned out to be different (A to C) when compared to the liver counterpart. However, this polymorphic difference did not cause any significant change in the primary structure of the protein because both GCA and GCC code for alanine. Our study would contribute to the understanding of the function of 16 M)a V-ATPase in the brain and of the mechanisms of neurotransmission.

  • PDF

A Study on the Shielding of Orbit by 3D Printed Filament in Brain CT (Brain CT검사 시 3D프린터 필라멘트에 따른 수정체 차폐 연구)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.101-108
    • /
    • 2021
  • The CT can accurately present the anatomical structure of an organ in the human body, and the resolution of the image is excellent. On Brain CT examination, the radiation sensitivity of the orbit is high and it is subject to many exposure effects. To reduce exposure dose of lens, this study compares change of exposure dose and shielding rate about non-shielding and shielding in a way of using two shielding materials, bismuth and tungsten. In this study, we used bismuth and tungsten filament as shielding materials made by 3D printing to measure the exposure dose according to the materials thickness and each of slices. To compare each shielding rate, 1 mm to 5 mm of two materials was measured with the head phantom fixed and the Magicmax universal dosimeter placed on the eye when the shielding material is not placed, and the shielding material is placed on it. In the 1 mm thick filament, the bismuth filament showed 26.8% and the tungsten filament showed 43.1% shielding rate. Therefore, tungsten presents much greater shielding effect than bismuth.

Identification and confirmation of 14-3-3 ζ as a novel target of ginsenosides in brain tissues

  • Chen, Feiyan;Chen, Lin;Liang, Weifeng;Zhang, Zhengguang;Li, Jiao;Zheng, Wan;Zhu, Zhu;Zhu, Jiapeng;Zhao, Yunan
    • Journal of Ginseng Research
    • /
    • v.45 no.4
    • /
    • pp.465-472
    • /
    • 2021
  • Background: Ginseng can help regulate brain excitability, promote learning and memory, and resist cerebral ischemia in the central nervous system. Ginsenosides are the major effective compounds of Ginseng, but their protein targets in the brain have not been determined. Methods: We screened proteins that interact with the main components of ginseng (ginsenosides) by affinity chromatography and identified the 14-3-3 ζ protein as a potential target of ginsenosides in brain tissues. Results: Biolayer interferometry (BLI) analysis showed that 20(S)-protopanaxadiol (PPD), a ginseng saponin metabolite, exhibited the highest direct interaction to the 14-3-3 ζ protein. Subsequently, BLI kinetics analysis and isothermal titration calorimetry (ITC) assay showed that PPD specifically bound to the 14-3-3 ζ protein. The cocrystal structure of the 14-3-3 ζ protein-PPD complex showed that the main interactions occurred between the residues R56, R127, and Y128 of the 14-3-3 ζ protein and a portion of PPD. Moreover, mutating any of the above residues resulted in a significant decrease of affinity between PPD and the 14-3-3 ζ protein. Conclusion: Our results indicate the 14-3-3 ζ protein is the target of PPD, a ginsenoside metabolite. Crystallographic and mutagenesis studies suggest a direct interaction between PPD and the 14-3-3 ζ protein. This finding can help in the development of small-molecular compounds that bind to the 14-3-3 ζ protein on the basis of the structure of dammarane-type triterpenoid.

An Enlarged Perivascular Space: Clinical Relevance and the Role of Imaging in Aging and Neurologic Disorders (늘어난 혈관주위공간: 노화와 신경계질환에서의 임상적의의와 영상의 역할)

  • Younghee Yim;Won-Jin Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.538-558
    • /
    • 2022
  • The perivascular space (PVS) of the brain, also known as Virchow-Robin space, consists of cerebrospinal fluid and connective tissues bordered by astrocyte endfeet. The PVS, in a word, is the route over the arterioles, capillaries, and venules where the substances can move. Although the PVS was identified and described first in the literature approximately over 150 years ago, its importance has been highlighted recently after the function of the waste clearing system of the interstitial fluid and wastes was revealed. The PVS is known to be a microscopic structure detected using T2-weighted brain MRI as dot-like hyperintensity lesions when enlarged. Although until recently regarded as normal with no clinical consequence and ignored in many circumstances, several studies have argued the association of an enlarged PVS with neurodegenerative or other diseases. Many questions and unknown facts about this structure still exist; we can only assume that the normal PVS functions are crucial in keeping the brain healthy. In this review, we covered the history, anatomy, pathophysiology, and MRI findings of the PVS; finally, we briefly touched upon the recent trials to better visualize the PVS by providing a glimpse of the brain fluid dynamics and clinical importance of the PVS.

Electrochemical Properties of Ti-30Ta-(3~15)Nb Alloys Coated by HA/Ti Compound Layer (HA/Ti 복합층 코팅한 Ti-30Ta-(3~15)Nb 합금의 전기화학적 특성)

  • Jeong, Yong-Hoon;Choe, Han-Cheol;Ko, Yeong-Mu
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.2
    • /
    • pp.57-62
    • /
    • 2008
  • Electrochemical properties of Ti-30Ta-$(3{\sim}15)$Nb alloys coated by HA/Ti compound layer have been studied by various electrochemical method. Ti-30Ta binary alloys contained 3, 7, 10, and 15 wt% Nb contents were manufactured by the vacuum furnace system. The specimens were homogenized for 24 hrs at $1000^{\circ}C$. The samples were cut and polished for corrosion test and coating. It was coated with HA/Ti compound layer by magnetron sputter. The HA/Ti non-coated and coated morphology of Ti alloy were analyzed by x-ray diffractometer(XRD) and filed emission scanning electron microscope(FE-SEM). The corrosion behaviors were investigated using potentiodynamic method in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The homoginazed Ti-30Ta-$(3{\sim}15wt%$)Nb alloys showed the ${\alpha}+{\beta}$ phase, and ${\beta}$ phase peak was predominantly appeared with increasing Nb content. The microstructure of Ti alloy was transformed from needle-like structure to equiaxed structure as Nb content increased. HA/Ti composite surface showed uniform coating layer with 750 nm thickness. The corrosion resistance of HA/Ti composite coated Ti-alloys were higher than those of the non-coated samples in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. Especially, corrosion resistance of Ti-Ta-Nb system increased as Nb content increased.