• 제목/요약/키워드: boundary damping

검색결과 296건 처리시간 0.027초

Numerical modelling for evaluating the TMD performance in an industrial chimney

  • Iban, A.L.;Brownjohn, J.M.W.;Belver, A.V.;Lopez-Reyes, P.M.;Koo, K.
    • Wind and Structures
    • /
    • 제17권3호
    • /
    • pp.263-274
    • /
    • 2013
  • A numerical technique for fluid-structure interaction, which is based on the finite element method (FEM) and computational fluid dynamics (CFD), was developed for application to an industrial chimney equipped with a pendulum tuned mass damper (TMD). In order to solve the structural problem, a one-dimensional beam model (Navier-Bernoulli) was considered and, for the dynamical problem, the standard second-order Newmark method was used. Navier-Stokes equations for incompressible flow are solved in several horizontal planes to determine the pressure in the boundary of the corresponding cross-section of the chimney. Forces per unit length were obtained by integrating the pressure and are introduced in the structure using standard FEM interpolation techniques. For the fluid problem, a fractional step scheme based on a second order pressure splitting has been used. In each fluid plane, the displacements have been taken into account considering an Arbitrary Lagrangian Eulerian approach. The stabilization of convection and diffusion terms is achieved by means of quasi-static orthogonal subscales. For each period of time, the fluid problem was solved and the geometry of the mesh of each fluid plane is updated according to the structure displacements. Using this technique, along-wind and across-wind effects have been properly explained. The method was applied to an industrial chimney in three scenarios (with or without TMD and for different damping values) and for two wind speeds, showing different responses.

Dynamic analysis by impact load in viscoelastic sandwich plates with FRP layer utilizing numerical method

  • Bayati, Mohammad Reza;Mazaheri, Hamid;Bidgoli, Mahmood Rabani
    • Steel and Composite Structures
    • /
    • 제43권2호
    • /
    • pp.229-240
    • /
    • 2022
  • The main objective of this work is presenting a mathematical model for the concrete slab with fiber reinforced polymer (FRP) layer under the impact load. Impacts are assumed to occur normally over the top slab and the interaction between the impactor and the structure is simulated using a new equivalent three-degree-of-freedom (TDOF) spring-mass-damper (SMD) model. The structure is assumed viscoelastic based on Kelvin-Voigt model. Based on the sinusoidal shear deformation theory (SSDT), energy method and Hamilton's principle, the motion equations are derived. Applying DQM, the dynamic deflection and contact force of the structure is calculated numerically so that the effects of mass, velocity and height of impactor, boundary conditions, FRP layer, structural damping and geometrical parameters of structure are shown on the dynamic deflection and contact force of system. Results show that considering structural damping leads to lower dynamic deflection and contact force. In addition, increasing the impact velocity of impactor yields to increases in the maximum contact force and deflection while the contact duration is decreased. The result shows that the contact force and the central deflection of the structure decreases and the contact time decreases with assuming FRP layer.

비특이화 간접경계적분방정식방법을 이용한 2차원 수치수조 개발 및 적용 (Development and Application of Two-Dimensional Numerical Tank using Desingularized Indirect Boundary Integral Equation Method)

  • 오승훈;조석규;정동호;성홍근
    • 한국해양공학회지
    • /
    • 제32권6호
    • /
    • pp.447-457
    • /
    • 2018
  • In this study, a two-dimensional fully nonlinear transient wave numerical tank was developed using a desingularized indirect boundary integral equation method. The desingularized indirect boundary integral equation method is simpler and faster than the conventional boundary element method because special treatment is not required to compute the boundary integral. Numerical simulations were carried out in the time domain using the fourth order Runge-Kutta method. A mixed Eulerian-Lagrangian approach was adapted to reconstruct the free surface at each time step. A numerical damping zone was used to minimize the reflective wave in the downstream region. The interpolating method of a Gaussian radial basis function-type artificial neural network was used to calculate the gradient of the free surface elevation without element connectivity. The desingularized indirect boundary integral equation using an isolated point source and radial basis function has no need for information about the element connectivity and is a meshless method that is numerically more flexible. In order to validate the accuracy of the numerical wave tank based on the desingularized indirect boundary integral equation method and meshless technique, several numerical simulations were carried out. First, a comparison with numerical results according to the type of desingularized source was carried out and confirmed that continuous line sources can be replaced by simply isolated sources. In addition, a propagation simulation of a $2^{nd}$-order Stokes wave was carried out and compared with an analytical solution. Finally, simulations of propagating waves in shallow water and propagating waves over a submerged bar were also carried and compared with published data.

Damping and vibration response of viscoelastic smart sandwich plate reinforced with non-uniform Graphene platelet with magnetorheological fluid core

  • Eyvazian, Arameh;Hamouda, Abdel Magid;Tarlochan, Faris;Mohsenizadeh, Saeid;Dastjerdi, Ali Ahmadi
    • Steel and Composite Structures
    • /
    • 제33권6호
    • /
    • pp.891-906
    • /
    • 2019
  • This study considers the instability behavior of sandwich plates considering magnetorheological (MR) fluid core and piezoelectric reinforced facesheets. As facesheets at the top and bottom of structure have piezoelectric properties they are subjected to 3D electric field therefore they can be used as actuator and sensor, respectively and in order to control the vibration responses and loss factor of the structure a proportional-derivative (PD) controller is applied. Furthermore, Halpin-Tsai model is used to determine the material properties of facesheets which are reinforced by graphene platelets (GPLs). Moreover, because the core has magnetic property, it is exposed to magnetic field. In addition, Kelvin-Voigt theory is applied to calculate the structural damping of the piezoelectric layers. In order to consider environmental forces applied to structure, the visco-Pasternak model is assumed. In order to consider the mechanical behavior of structure, sinusoidal shear deformation theory (SSDT) is assumed and Hamilton's principle according to piezoelasticity theory is employed to calculate motion equations and these equations are solved based on differential cubature method (DCM) to obtain the vibration and modal loss factor of the structure subsequently. The effect of different factors such as GPLs distribution, dimensions of structure, electro-magnetic field, damping of structure, viscoelastic environment and boundary conditions of the structure on the vibration and loss factor of the system are considered. In order to indicate the accuracy of the obtained results, the results are validated with other published work. It is concluded from results that exposing magnetic field to the MR fluid core has positive effect on the behavior of the system.

비선형 수치해석을 통한 단자유도 얕은기초 구조물의 지진 응답특성 검증 (Verification of Nonlinear Numerical Analysis for Seismic Response of Single Degree of Freedom Structure with Shallow Foundation)

  • 추연욱;이진선;김동수
    • 한국지반공학회논문집
    • /
    • 제29권3호
    • /
    • pp.29-40
    • /
    • 2013
  • 본 논문에서는 얕은기초를 가지는 단자유도 구조물의 지진시 응답특성을 시간영역 비선형 유한차분해석을 이용하여 살펴보았다. 해석결과는 중력가속도 20g에서 시행된 동일한 제원을 가지는 동적원심모형실험 결과를 통하여 검증되었다. 검증결과 실험과 해석의 통제운동지점 경계조건 차이에서 발생하는 차이는 지반의 비선형 거동특성으로 발생하는 이력감쇠에 지반의 감쇠비를 추가하여 감소시킬 수 있었다. 이로부터 얻어진 구조물과 지반에서 계측된 가속도 시간이력 및 주파수대역 응답곡선 모두 유사한 결과를 나타내어, 시간영역 비선형 유한차분해석을 통한 지반-구조물 상호작용 해석의 신뢰성을 확보할 수 있었으며, 향후 동적원심모형으로 계측이 어려운 구조물의 잔류변위, 작용토압 등을 효과적으로 판단할 수 있을 것으로 사료된다.

직교 격자계 기반 유동해석기법을 이용한 파랑 중 해양구조물의 운동 해석 (Numerical Study on Wave-induced Motion of Offshore Structures Using Cartesian-grid based Flow Simulation Method)

  • 남보우;김용환;양경규;홍사영;성홍근
    • 한국해양공학회지
    • /
    • 제26권6호
    • /
    • pp.7-13
    • /
    • 2012
  • This paper presents a numerical study of the wave loads acting on offshore structures using a Cartesian-grid-based flow simulation method. Finite volume discretization with a volume-of-fluid (VOF) method is adopted to solve two-phase Navier-Stokes equations. Among the many variations of the VOF method, the CICSAM scheme is applied. The body boundary conditions are satisfied using a porosity function, and wave generation is carried out by using transient (wave or damping) zone approaches. In order to validate the present numerical method, three different basic offshore structures, including a sphere, Pinkster barge, and Wigley model, are numerically investigated. First, diffraction and radiation problems are solved using the present numerical method. The wave exciting and drift forces from the diffraction problems are compared with potential-based solutions. The added mass and wave damping forces from the radiation problems are also compared with the potential results. Next, the wave-induced motion responses of the structures are calculated and compared with the existing experimental data. The comparison results are fairly good, showing the validity of the present numerical method.

강제동요를 이용한 원형실린더 점성 롤댐핑 연구 (Study on the Viscous Roll Damping around Circular Cylinder Using Forced Oscillations)

  • 양승호
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.71-76
    • /
    • 2017
  • 선박 및 해양구조물 설계에 있어 롤댐핑에 관한 문제는 유체점성과 현상자체의 비선형성으로 인해 공학자들에게 있어 난제로 남아있다. 본 연구에서는 강제동요방법을 이용하여 원형실린더의 점성 롤감쇠에 관한 연구를 수행하였다. 토크 센서를 이용하여 강제동요 시 발생하는 롤모멘트(roll moment)를 강제동요 주기별로 계측하였고 이를 실험식(empirical formula)과 비교 검토 하였다. 점성에 의한 전단력으로부터 계측된 토크의 크기가 상대적으로 작은 값임에도 불구하고 실험식으로부터 얻어진 계산값들과 정성적으로 유사한 결과를 보였고, 일부 주기에서는 정량적으로도 잘 일치하는 결과를 보였다. 또한, PIV 계측기법을 통해 원형실린더 벽면주위의 유동을 면밀히 관찰하였으며, 유체점성으로 인해 원형실린더 벽면근처에서 경계층이 형성되고 자유수면에서 원형실린더의 주기적인 강제회전동요로 인해 미소한 크기의 파가 생성(wave making)됨을 PIV 계측결과의 분석을 통해 확인하였다. 본 연구에서는 점성 롤감쇠로 인한 실험식의 적합성을 모형시험을 통해 확인하였고, PIV 계측기법을 통해 벽면주위의 유체점성으로 인한 조파현상을 입증하였다.

댐의 시간영역 지진응답 해석을 위한 호소의 집중변수모델 (Lumped Parameter Model of Transmitting Boundary for the Time Domain Analysis of Dam-Reservoir System)

  • 김재관;이진호;조정래
    • 한국지진공학회논문집
    • /
    • 제5권4호
    • /
    • pp.27-38
    • /
    • 2001
  • 반무한 호소의 동적 모델링을 위한 역학적 집중변수모델을 제안하였다. 깊이가 일정한 2차원 반무한 호소의 전달경계의 정해를 구하였다. 정해의 거동특성을 주파수 영역과 시간 영역에서 조사하였다. 고유진동수와 합성곱 적분의 핵함수인 베셀 함수의 모양 등과 같은 해의 주요 특성이 변하지 않도록 질량, 감쇠기, 스프링 계수를 구한다. 최종 집중 변수 모델은 각각의 고유값에 대해 2개의 질량, 1개의 스프링, 2개의 감쇠기로 구성된다. 적용 예제를 통하여 새로운 집중변수모델이 댐-호소계의 시간 영역 해석에 효율적으로 사용될 수 있음을 확인하였다.

  • PDF

스트립 배열된 다수 부이에 의한 파력에너지 추출 (Wave Power Extraction by Strip Array of Multiple Buoys)

  • 조일형
    • 한국해양공학회지
    • /
    • 제28권5호
    • /
    • pp.474-483
    • /
    • 2014
  • The majority of existing WECs (wave energy converters) are designed to achieve maximum power at a resonance condition. In the case of a single WEC, its size must be large enough for tuning, and it has high efficiency only within a limited frequency band. Recently, wave power extraction by deploying many small buoys in a compact array has been studied under the assumption that the buoy's size and separation distance are much smaller than the water depth, wave length, and size of the array. A boundary value problem involving the macro-scale boundary condition on the mean surface covered by an infinite strip of buoys is solved using the eigenfunction expansion method. The energy extraction efficiency (${\varepsilon}=1-R^2_f-T^2_r$), where $R_f$ and $T_r$ are the reflection and transmission coefficients for a strip array of buoys, is assessed for various combinations of packing ratio, strip width, and PTO damping coefficient.

Optimal layout of a partially treated laminated composite magnetorheological fluid sandwich plate

  • Manoharan, R.;Vasudevan, R.;Jeevanantham, A.K.
    • Smart Structures and Systems
    • /
    • 제16권6호
    • /
    • pp.1023-1047
    • /
    • 2015
  • In this study, the optimal location of the MR fluid segments in a partially treated laminated composite sandwich plate has been identified to maximize the natural frequencies and the loss factors. The finite element formulation is used to derive the governing differential equations of motion for a partially treated laminated composite sandwich plate embedded with MR fluid and rubber material as the core layer and laminated composite plate as the face layers. An optimization problem is formulated and solved by combining finite element analysis (FEA) and genetic algorithm (GA) to obtain the optimal locations to yield maximum natural frequency and loss factor corresponding to first five modes of flexural vibration of the sandwich plate with various combinations of weighting factors under various boundary conditions. The proposed methodology is validated by comparing the natural frequencies evaluated at optimal locations of MR fluid pockets identified through GA coupled with FEA and the experimental measurements. The converged results suggest that the optimal location of MR fluid pockets is strongly influenced not only by the boundary conditions and modes of vibrations but also by the objectives of maximization of natural frequency and loss factors either individually or combined. The optimal layout could be useful to apply the MR fluid pockets at critical components of large structure to realize more efficient and compact vibration control mechanism with variable damping.