• Title/Summary/Keyword: bottom temperature

Search Result 1,361, Processing Time 0.024 seconds

A Study on the Characteristics of Natural Convection in a Partially Opened Enclosure with a Heat Source (발열체와 부분 열림 수직벽을 갖는 사각 공간내 자연대류 특성 해석)

  • Shim, Dong-Sik;Kang, Bo-Seon;Cha, Dong-Jin;Ju, Won-Jong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.322-327
    • /
    • 2000
  • Natural convection heat transfer in an enclosure with an opening in the right vertical wall and a heat source at the bottom surface is investigated using a holographic interferometric technique. The effects of the opening length, divider length attached to the top wall, and heater temperature on the temperature distribution are examined. The openging length as well as the divider length greatly affects the degree of inflow and outflow of air. With a small opening, the opening doesn't affect much the upward warm air flow resulting in the symmetric temperature distribution. On the other hand, with the increase of the opening length, the inward cold flow moves the upward flow to the left direction. With the increase of the divider length, temperature in the lower region of enclosure becomes higher for the small opening and lower for the large opening.

  • PDF

Buoyant Convection in a Cylinder with Azimuthally-varying Sidewall Temperature (방위각방향 온도변화를 가지는 실린더 내의 부력 유동)

  • Chung, K.H.;Hyun, J.M.;Song, T.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.45-50
    • /
    • 2000
  • A numerical investigation is made of three-dimensional buoyant convection of a Boussinesq-fluid in a vertical cylinder. The top and bottom endwalls are thermally insulated. Flow is driven by the substantial azimuthal variations in thermal boundary conditions. Comprehensive numerical solutions to the Navier-Stokes equations are obtained. The representative Rayleigh number is large, thus, the overall flow pattern is of boundary layer-type. Three-dimensional (low characteristics are described. Specially, the global flow and the heat transfer features are delineated when the severity of azimuthal variation of sidewall temperature n, is intensified. Temperature and velocity fields on the meridional planes and the planes of constant height are presented. The global flow weakens as n becomes large. The pattern of the local Nusselt number on the surface of cylinder is similar regardless of n. The convective gain in heat transfer activities is reduced as n increases.

  • PDF

The study of phase-change according to temperature and voltage in chalcogenide thin film (칼코게나이드 박막의 온도, 전압에 따른 상변화에 관한 연구)

  • Yang, Sung-Jun;Shin, Kyung;Park, Jung-Il;Nam, Lee-Ki;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.416-419
    • /
    • 2003
  • There is a growing need for a nonvolatile memory technology with faster speed than existing nonvolatile memories. We studied of phase-change according to temperature and voltage in chalcogenide thin film base on $Ge_2Sb_2Te_5$. Searching for Tg(Glass transition temperature) temperature controlled on hotplate with RT quenching. We measure I-V characteristic through out bottom electrode(ITO) and top electrode(Al) between $Ge_2Sb_2Te_5$. And compared with I-V characteristics after impress the variable stress.

  • PDF

A Thermal hydraulic Investigation on ADSR Liquid Lead Target

  • Kim, Ju Y.;Byung G. Huh;Chang H, Chung;Tae Y. song;Park, Won S.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.666-671
    • /
    • 1998
  • Computational fluid dynamics(CFD) code FLUENT[11 was used to simulate the thermal hydraulic processes occuring in conceptual design of the accelerator-driven subcritical reactor(ADSR) liquid lead target. The purpose of the analysis is to investigate the thermal hydraulic characteristics of liquid lead as ADSR target material with various target geometries and injection locations of proton beam. In the calculation analysis, the local temperature of the liquid lead target rises to the boiling temperature very rapidly When the proton beam is injected from the bottom of the target system, the duration time to reach the boiling temperature is longer and the temperature distribution is flatter than other cases.

  • PDF

Fundamental Properties and Adiabatic Temperature Rise of Concrete with the Combination of Mineral and Chemical Admixture (혼화재료의 조합사용에 따른 콘크리트의 기초물성 및 단열온도상승 특성)

  • Jeon Chung Keun;Kim Jong;Shin Dong-An;Yoon Gi-Won;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.345-348
    • /
    • 2005
  • This paper presents the result of adiabetic temperature rise and fundamental properties of concrete combining admixtures. According to results, difference of setting time with I5.5hours is observed between S-P and R-F30 mixture. Based on the adiabetic temperature rise test, 8$^{circ}C$of heat producted occurs between E-P and R-F30 mixture. is applied to estimate the temperature rising under adiabetic curing condition, which exhibits closer consistency with tested value. The function mentioned above can account for the effect of dormant period in hydration process at early stage on hydration heat production. It reveals that the consideration of placing layer based on the mixture adjustment(E-P mixture at top layer and R-F30 mixture at bottom layer) in mass concreting will contribute to reduce hydration heat as well as alleviate tensile stress discrepancy between placing layer.

  • PDF

A Study on the Indoor Thermal Environment of House Using Earth Brick Wall (황토벽돌벽 주택의 실내온열환경에 관한 연구)

  • 이재윤
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.25-32
    • /
    • 2004
  • The purpose of this study is to understand the indoor thermal environment in the earth brick wall building what is called a ecological Architecture. To investigate thermal performances of the earth brick walls, it measured indoor and outdoor air temperature, relative humidity, globe temperature and PMV in reference house. The result of this study were summarized as the followings; 1) When the outdoor average air temperature was $21.8^{\circ}$, livingroom was $24.9^{\circ}$, kitchen was $25.1^{\circ}$ and 2nd floor room was $25.6^{\circ}$ at 150 cm height from the floor. 2) Although the average outdoor relative humidity was 78%, the livingroom was 67.5%. 3) As the air temperature difference between at the top and bottom was $0.6^{\circ}$ in living room, this value was below 1 % of PPD by ASHRAE Handbook. 4) Predicted Mean Vote(PMV) by ISO-7730 was +0.41.

Structural and Electrical Properties of Bismuth Magnesium Niobate Thin Films deposited at Various Temperatures

  • Park, Jong-Hyun;Yoon, Soon-Gil
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.153-156
    • /
    • 2007
  • Structural and electrical properties of the fully crystallized-bismuth magnesium niobate ($Bi_2Mg_{2/3}Nb_{4/3}O_7$, BMN) films with 15 mol% excess bismuth deposited on Pt bottom electrode by pulsed laser deposition are characterized for various deposition temperatures. The BMN films were crystallized with a monoclinic structure from $300^{\circ}C$ and the surface roughness slightly decreases with increasing deposition temperature. The capacitance density of the films increases with increasing deposition temperature and especially, films deposited at $400^{\circ}C$ exhibit a capacitance density of approximately $620nF/cm^2$. The crystallized BMN films with approximately 170 nm thickness exhibit breakdown strength above 600 kV/cm (${\leq}10V$) irrespective of deposition temperature and a leakage current density of approximately $2{\times}10^{-8}A/cm^2$ at 590kV/cm (at 10 V).

SURGE LINE STRESS DUE TO THERMAL STRATIFICATION

  • Jhung, Myung-Jo;Choi, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.239-250
    • /
    • 2008
  • If there is a water flow with a range of temperature inside a pipe, the wanner water tends to float on top of the cooler water because it is lighter, resulting in the upper portion of the pipe being hotter than the lower portion. Under these conditions, such thermal stratification can play an important role in the aging of nuclear power plant piping because of the stress caused by the temperature difference and the cyclic temperature changes. This stress can limit the lifetime of the piping, even leading to penetrating cracks. Investigated in this study is the effect of thermal stratification on the structural integrity of the pressurizer surge line, which is reported to be one of the pipes most severely affected. Finite element models of the surge line are developed using several element types available in a general purpose structural analysis program and stress analyses are performed to determine the response characteristics for the various types of top-to-bottom temperature differentials due to thermal stratification. Fatigue analyses are also performed and an allowable environmental correction factor is suggested.

Mock-up Test on the Reduction of Hydration Heat of Mass Concrete for Transfer Girder (전이보 매스콘크리트의 수화열 저감에 관한 Mock-up 실험)

  • Yoon Seob;Hwang Yin Seong;Baik Byung Hoon;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.707-710
    • /
    • 2004
  • This paper reported the results of mock-up test on mass concrete for transfer girder using setting time difference of super retarding agent(SRA). According to test results, two mock-up structures were made. Plain concrete without placing layer reached maximum temperature after 24hours since placement and caused surface hydration cracks at top section. However, concrete with placing layer reached maximum temperature after 72hours and surface temperature was higher than center temperature, which did not cause surface crack. After form removing, no crack was observed at side surface of plain concrete, while concrete using SRA at mid section had surface scaling and settling crack. According to coring results, concrete with placing layer had a penetration crack from top section to bottom section. Therefore, the setting time difference method to reduce hydration heat will have difficulty in applying the mass concrete for transfer girder.

  • PDF

Spring Length Effect on the Flow Capacity of automatic Flow-Temperature Control Valve (자동 정유량 온도조절밸브의 스프링 길이가 밸브 용량에 미치는 영향)

  • Yoo, Seon-Hak;Kang, Seung-Duk;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.174-177
    • /
    • 2003
  • The automatic temperature control valve is used to control the flow rate of heating water in the large apartment complex and buildings. It is important to have simillar heating flow rate in the apartments, even though the apartment is top or bottom floors. To achieve those purposes, the automatic flow-temperature control valve was developed. The perfromance of this control valve is effected by the catridge shape and spring length. The flow capacity of this control valve is obtained with the different shape of catridges and with change of spring length.

  • PDF