• 제목/요약/키워드: bottom loss

검색결과 264건 처리시간 0.023초

남해 연안해역의 부영양화 2. 남해 연안해역의 저질 및 수질의 부영양화 실태 (Eutrophication in the Namhae Coastal Sea 2. The Aspects of Eutrophication of Bottom Mud and Surface Seawater in the Namhae Coastal Seas)

  • 김성재
    • 한국습지학회지
    • /
    • 제3권2호
    • /
    • pp.107-118
    • /
    • 2001
  • The aim of this paper is to grasp eutrophication aspects in Namhae coastal seas, statistically analyzing existing data for their surface seawater and bottom mud. A pollution level(ignition loess) of bottom mud, on the whole, trended to increase as moving the coastal sea around Mokpo-Wando toward the east(Gyeongnam Namhae coastal seas). Especially, the pollution level(ignition loss=10.5%) of bottom mud for the coastal sea around Tongyeong-Keoje-Gosung was similar to that(10.3%) for the coastal sea around Masan-Jinhae, whose coastal marine pollution was the severest in Namhae coastal seas. It indicates that large amounts of pollutant from aqualculture facilities have been, thus far, accumulated on the coastal sea around Tongyeong-Keoje-Gosung, considering there was no significant inflow of sewage and industrial wastewater into this coastal sea. A COD, T-N, and T-P level of surface seawater, on the whole trended to increase as moving the coastal sea around Mokpo-Wando toward the east(Gyeongnam Namhae coastal seas). A COD level appeared to be the second grade of coastal water quality over the entire year throughout all Namhae coastal seas A T-N level exceeded the third grade of coastal water quality throughout all Namhae coastal seas except the coastal sea around Mokpo-Wando. Especially, a T-N level exceeded as many as three and six times over the third grade of coastal water quality in the coastal sea around Tongyeong-Keoje-Gosung and Masan-Jinhae, respectively. A T-P level appeared to be the second grade of coastal water quality in the coastal sea around Mokpo-Wando and the third grade of coastal water quality in the coastal sea around Yosu-Narnhae and Tongyeong-Keoje-Gosung, while it exceeded as many as two times over the third grade of coastal water quality. A degree of eutrophication of the surface seawater was 1.5 in the coastal sea around Mokpo-Wando and 11.9 In the coastal sea around Tongyeong-Keoje-Gosung, gradually increasing as moving toward the east(Gyeongnam Narnhae coastal seas). It sharply increased to 146.1 in the coastal sea around Masan-Jinhae. Because the degree of eutrophication throughout all Namhae coastal seas exceeded 1, a red tide organism could pose a possibility of proliferation at any place of Namhae coastal seas if other requirements were satisfied. It indicates that a red tide may move to another place once a red tide breaks out at a place of Namhae coastal seas.

  • PDF

고성${\cdot}$자란만 패류양식장 저이의 부영양화 (Eutrophication of Bottom Mud in Shellfish Farms, the Goseong-Jaran Bay)

  • 조창환;박경양
    • 한국수산과학회지
    • /
    • 제16권3호
    • /
    • pp.260-264
    • /
    • 1983
  • 고성${\cdot}$자란만 패류 양성장 저질의 부영양화정도와 부영양화속도를 구명하고 양성장의 적절한 관리, 보존을 위한 기초자료를 얻고저 1981년 하계중앙성장 저니중에 함유된 유기물량 및 유화물량을 측정하였다. 1. 표충저니 중 COD양은 $12.5{\sim}19.5mg/g$으로 평 군 15.3 mg/g이었고 강열감량은 $6.7{\sim}12.4\%$로 평균 $9.1\%$, 페오파이친색소량은 $6.8{\sim}11.0{\mu}g/g$으로 평균 $9.1{\mu}g/g$이었다. 유화물량은 $0.18{\sim}0.64{\mu}g/g$으로 평균 0.36 mg/g이었다. 2. 상기 양들은 유화물의 경우, 부영양화의 상한치인 0.3mg/g을 약간 상회하고 있지만, 그 밖의 값들은 대체로 낮은 값이고, 1976년의 조사치와 비교해도 6년간 약간만이 증가한것으르 보아, 부영양화의 속도는 매우 완만하였다. 3. 저이오염도로 보아, 득량만과 가막양만에 비하면 약간 나쁜 편이었지만 인근에 위치한 진해만이나 한산${\cdot}$거제만에 비하aus 매우 양호한 편이었다. 또, 페오파이친색소량이 적은 것으로 보아 양성패에 의한 배설물의 다량 축적으로 인한 문제는 없는 것 같다.

  • PDF

3차원 해석적 방법에 의한 사다리꼴 휜 해석 (Trapezoidal Fin Analysis by the 3-D Analytical Method)

  • 이성주;강형석
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.388-397
    • /
    • 2000
  • Comparison of the heat conduction into a trapezoidal fin and the heat loss from the fin by convection is made in this study Also, the ratio of heat loss from each surface to the total heat loss and the temperature distribution are analyzed using a 3-D analytical method. A trapezoidal fin whose tip height is half the root height is chosen as the model. The results show that the heat transfer rates from the tip and from both sides are comparable with each other as the non-dimensional width and length vary while the heat transfer rate from the bottom and top is dominant.

  • PDF

박막형 FBAR 공진기 설계 및 제작 (FBAR devices for RF bandpass filter applications)

  • Yoon, Gi-Wan;Park, Sung-Chang
    • 한국정보통신학회논문지
    • /
    • 제5권7호
    • /
    • pp.1321-1325
    • /
    • 2001
  • 본 논문에서는 압전박막 및 이들의 FBAR소자 응용에 대한 연구를 발표 한다. FBAR소자는 상부 및 하부 전극 사이에 압전체가 삽입되어 있는 공진부와 SiO2/W 이 여러층으로 적층되어 있는 음향반사층부분 크게 두 부분으로 구성되어 있다. 시뮬레이션 및 측정을 통하여 제작된 여러가지 FBAR 소자들을 평가하였다. 실험결과 우수한 삽입손실, 반사손실 및 풀질계수가 얻어졌다. 따라서 FBAR 기술은 RF 대역 필터 응용을 위해서 대단히 유망한 기술로 생각된다.

  • PDF

주위의 열대류계수가 다를때 사각핀으로부터의 열손실에 대한 비대칭적인 핀바닥온도의 영향 (Effect of Asymmetric Root Temperature on the Heat Loss From a Rectangular Fin Under Unequal Surrounding Heat Convection Coefficient)

  • 강형석;김성준
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1567-1571
    • /
    • 1994
  • Under the assumption that thermal conductivity of the fin is constant and the conditions ate steady state, effects of non-constant and thermally asymmetric root temperature and unequal surrounding convection coefficients of the fin on the heat loss from a fin of rectangular profile are investigated. The heat loss form a rectangular fin becomes maximum when the highest root temperature deviates from the fin center to the fin side which has a higher convection coefficient as surrounding convection coefficients of the fin increase and as the difference between the convection coefficient of fin top side and that of fin bottom side increases.

Performance Analysis of A Modified Asymmetric Rectangular Fin

  • Kang, Hyung Suk
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제6권2호
    • /
    • pp.109-120
    • /
    • 2002
  • The dimensionless heat loss from a modified asymmetric rectangular fin is investigated as a function of the fin top and tip Biot numbers using the two-dimensional separation of variables method. A rectangular fin is modified by attaching the wing on the top side of the fin. Fin effectiveness and efficiency with the variation of the location of the wing and the width of the wing are presented. The relationship between top surface Biot number and bottom surface Biot number as well as the relationship between the dimensionless wing height and the location of the wing for equal amount of heat loss is also discussed.

  • PDF

RF 대역통과필터 응용을 위한 FBAR 소자 (FBAR devices for RF bandpass filter applications)

  • Giwan Yoon;Park, Sungchang
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 추계종합학술대회
    • /
    • pp.621-625
    • /
    • 2001
  • 본 논문에서는 압전박막 및 이들의 FBAR 소자 응용에 대한 연구를 발표 한다. FBAR 소자는 상부 및 하부 전극 사이에 압전체가 삽입되어 있는 공진부와 SiO$_2$/W 이 여러층으로 적층되어 있는 음향반사층부분 크게 두 부분으로 구성되어 있다. 시뮬레이션 및 측정을 통하여 제작된 여러가지 FBAR 소자들을 평가하였다. 실험결과 우수한 삽입손실, 반사손실 및 품질계수가 얻어졌다. 따라서 FBAR 기술은 RF 대역 필터 응용을 위해서 대단히 유망한 기술로 생각된다.

  • PDF

마이크로핀관과 평활관에서의 증발열전달과 압력손실 특성 (Evaporation heat transfer and Pressure loss in micro-fin tubes and a smooth tube)

  • 장세환;정시영;홍영기
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.215-223
    • /
    • 1999
  • Evaporation heat transfer coefficient and pressure loss were measured for three different micro-fin tubes and a smooth tube. The experiments were carried out with R-22 over a wide range of vapor Quality, mass velocity and heat flux. Heat transfer coefficient of the tube with slightly modified fin shape was found to be higher than that of the commercial reference tube by 60%. The improvement of heat transfer has been achieved without noticeable increase of pressure loss. Heat transfer coefficient was increased with increasing quality, refrigerant mass flux, and heat flux. However, the effect of refrigerant mass flux and heat flux was not great. Heat transfer coefficient at bottom was lower than that at top of the tube in low quality region, which suggested the existence of stratification in the micro-fin tube. Pressure drop was linearly increased with increasing refrigerant quality and was proportional to about square of mass flux.

  • PDF

음선 모델에 적용된 이층 해저 바닥 모델의 유효성 (Validity of Two-layered Ocean Bottom Model for Ray Model)

  • 이근화;성우제
    • 한국음향학회지
    • /
    • 제34권6호
    • /
    • pp.470-478
    • /
    • 2015
  • 음선 모델링에서 다층 해저 바닥을 고려하는 경험적 방법 중 하나는 단일층 가정으로써, 다층 구조에 대한 평면파 반사계수를 사용하는 것이다. 본 연구자는 이층 해저 바닥에 대해 단일 층 가정의 유효성을 조사하고, 음속비, 송수신 거리 당 층 두께, 1차 반사파의 스침각의 함수로 표현되는 간단한 부등식 조건을 얻었다. 부등식 조건으로부터, 단일 층 가정이 실제 해양 환경의 중주파수 음선 모델링에 적용될 수 있음을 보였다. 마지막으로 한국 동해와 유사한 해양환경에 대해 수치실험을 수행하였다. 다층 해저 바닥에 대한 평면파 반사계수를 적용한 기하학적 빔 모델을 이용하여 비상관 전달손실을 계산하고, 서울대학교에서 개발한 포물선 방정식 패키지인 SNUPE 2.0의 결과와 비교하였다.

수중드론을 활용한 선박 선저검사용 수중 카메라 영상보정에 대한 연구 (A Study on Underwater Camera Image Correction for Ship Bottom Inspection Using Underwater Drone)

  • 하연철;박준모
    • 융합신호처리학회논문지
    • /
    • 제20권4호
    • /
    • pp.186-192
    • /
    • 2019
  • 일반적으로 운항 중인 선박이나 건조 중인 선박의 선저에는 많은 해양 생물들이 부착된다. 이러한 현상으로 인해 선박 표면의 거칠기가 증가하여 선박속도의 손실이 발생하게 되고 결과적으로 경제적 손실 및 환경오염 등의 발생을 초래하게 된다. 본 연구에서는 선박 선저에 부착된 해양생물 및 선저 상태를 검사하는 수중드론 등의 카메라 영상을 획득/활용한다. 획득된 해당 영상은 관리자 육안확인에 의해 해양 생물들에 따른 거칠기 등을 판단하게 된다. 이에 영상을 보정하는 필터 알고리즘을 원본 영상에 적용함으로써 해양 생물들 부착 여부 등에 대한 올바른 판단에 도움을 줄 수 있다. 수중 영상의 보정 알고리즘에는 다양한 필터가 필요하며, 어두운 수중 환경에 맞는 조명이 판단에 많은 영향을 미치므로 조명의 밝기 정도에 따른 해양 생물 부착 여부 판단에 대한 내용도 소개하고자 한다. 본 연구에서 적용된 보정 알고리즘 및 각 알고리즘별 조명 밝기에 따른 연구테스트 결과는 많은 분야에 적용 가능할 것으로 사료된다.