• Title/Summary/Keyword: bone state

Search Result 368, Processing Time 0.021 seconds

Precipitation of Calcium Phosphate at pH 5.0 for the β Tri-calcium Phosphate Cement

  • Chang, Myung Chul
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.4
    • /
    • pp.275-279
    • /
    • 2013
  • The purpose of this study was to prepare calcium phosphate cement [CPC] for use in artificial bone. Nano-crystalline calcium phosphate [CaP] was precipitated at $37^{\circ}C$ using highly active $Ca(OH)_2$ in DI water and an aqueous solution of $H_3PO_4$. From the XRD measurements, the nano-CaP powder was close to apatitic TCP phase and the powders fired at $800^{\circ}C$ showed a critical ${\beta}$-TCP phase. A mixture of one mole $CaCO_3$ and two moles di-calcium phosphate was calcined at $1100^{\circ}C$ to make a reference ${\beta}$-TCP material. The nano-CaP powders were added to the normal ${\beta}$-TCP matrix and fired at $900^{\circ}C$ to make a ${\beta}$-TCP block. The sintered block showed improved mechanical strength, which was caused by the solid state interaction between nano-CaP and normal ${\beta}$-TCP.

Animal Performance and Carcass Characteristics of Bulls (1/2 Purunã vs 1/2 Canchim) Slaughtered at 16 and 22 Months Old, and Three Different Weights

  • Prado, Ivanor Nunes Do;Eiras, Carlos Emanuel;Fugita, Carlos Alberto;Passetti, Rodrigo Augusto Cortez;Ornaghi, Mariana Garcia;Rivaroli, Dayane Cristina;Pinto, Adriana Aparecida;Moletta, Jose Luiz
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.5
    • /
    • pp.612-619
    • /
    • 2015
  • Current study aimed to evaluate the performance of bulls (1/2 Purun$\tilde{a}$ vs 1/2 Canchim) slaughtered at two ages and three different weights. One hundred and thirteen bulls were divided into two slaughter ages (16 and 22 months) and three different slaughter weights (light, 422 kg; medium, 470 kg; and heavy, 550 kg). The body weight was higher for bulls slaughtered at 16 months. Daily gain, carcass weight and dressing were higher for bulls slaughtered at 16 months. Feed intake was higher for bulls slaughtered at 22 months although feed efficiency was better for bulls slaughtered at 16 months. Carcass characteristics were better for bulls slaughtered at 16 months. The percentages of muscle, fat and bone and meat characteristics were similar between two slaughter ages. Feed intake and animal performance was lower for lighter animals. Feed conversion and carcass dressing were similar in the three slaughter weights. Muscle percentage was higher for heavier animals but fat and bone percentages were lower. Slaughter weight had no effect on meat characteristics.

Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysis

  • Hussein, Mostafa Omran
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.333-340
    • /
    • 2013
  • PURPOSE. This study was accomplished to assess the biomechanical state of different retaining methods of bar implant-overdenture. MATERIALS AND METHODS. Two 3D finite element models were designed. The first model included implant overdenture retained by Hader-clip attachment, while the second model included two extracoronal resilient attachment (ERA) studs added distally to Hader splint bar. A non-linear frictional contact type was assumed between overdentures and mucosa to represent sliding and rotational movements among different attachment components. A 200 N was applied at the molar region unilaterally and perpendicular to the occlusal plane. Additionally, the mandible was restrained at their ramus ends. The maximum equivalent stress and strain (von Mises) were recorded and analyzed at the bone-implant interface level. RESULTS. The values of von Mises stress and strain of the first model at bone-implant interface were higher than their counterparts of the second model. Stress concentration and high value of strain were recognized surrounding implant of the unloaded side in both models. CONCLUSION. There were different patterns of stress-strain distribution at bone-implant interface between the studied attachment designs. Hader bar-clip attachment showed better biomechanical behavior than adding ERA studs distal to hader bar.

Fabrication and Cell Culturing on Carbon Nanofibers/Nanoparticles Reinforced Membranes for Bone-Tissue Regeneration

  • Deng, Xu Liang;Yang, Xiao Ping
    • Carbon letters
    • /
    • v.13 no.3
    • /
    • pp.139-150
    • /
    • 2012
  • Poly-L-lactic acid (PLLA), PLLA/hydroxyapatite (HA), PLLA/multiwalled carbon nanotubes (MWNTs)/HA, PLLA/trifluoroethanol (TFE), PLLA/gelatin, and carbon nanofibers (CNFs)/${\beta}$-tricalcium phosphate (${\beta}$-TCP) composite membranes (scaffolds) were fabricated by electrospinning and their morphologies, and mechanical properties were characterized for use in bone tissue regeneration/guided tissue regeneration. MWNTs and HA nanoparticles were well distributed in the membranes and the degradation characteristics were improved. PLLA/MWNTs/HA membranes enhanced the adhesion and proliferation of periodontal ligament cells (PDLCs) by 30% and inhibited the adhesion of gingival epithelial cells by 30%. Osteoblast-like MG-63 cells on the randomly fiber oriented PLLA/TEF membrane showed irregular forms, while the cells exhibited shuttle-like shapes on the parallel fiber oriented membrane. Classical supersaturated simulated body fluids were modified by $CO_2$ bubbling and applied to promote the biomineralization of the PLLA/gelatin membrane; this resulted in predictions of bone bonding bioactivity of the substrates. The ${\beta}$-TCP membranes exhibit good biocompatibility, have an effect on PDLC growth comparable to that of pure CNF membrane, and can be applied as scaffolds for bone tissue regeneration.

Dose Comparison Analysis of Temporal bone CT scan to conventional scan method during helical scan method (Temporal bone CT 검사 시 conventional scan 방식과 helical scan방식에 따른 선량 비교분석)

  • Gang, Su-hong;Park, Yong-Seong;Lee, Rae-Gon;Hwang, Seon-Kwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.49-56
    • /
    • 2015
  • Temporal bone CT scan side skull fracture. In addition to the confirmation of the ossicles, such as fractures and dislocations, temporomandibular facial fractures, deformities surgery helps to establish a science plan. Cochlear implant surgery has been performed in the state before and after identifying purposes. Test methods are being implemented by the Conventional direct axial and Direct coronal scan, the basic method of Temporal bone CT. Helical scan is a fast Volumetric data obtained compared with the Conventional scan, the patient reduced the dose, and there are some advantages, such as reduced Beam hardening streak artifacts caused by dental fillings. This study is a comparative analysis by dose reduction for patients with a dose according to the conventional scan method and then effective from 2015 by helical scan method performed in 2014 through the retrospective survey, which was then optimized for the purpose of inspection.

  • PDF

Fracture behavior modeling of a 3D crack emanated from bony inclusion in the cement PMMA of total hip replacement

  • Mohamed, Cherfi;Abderahmane, Sahli;Benbarek, Smail
    • Structural Engineering and Mechanics
    • /
    • v.66 no.1
    • /
    • pp.37-43
    • /
    • 2018
  • In orthopedic surgery and in particular in total hip arthroplasty, the implant fixation is carried out using a surgical cement called polymethylmethacrylat (PMMA). This cement has to insure a good adhesion between implant and bone and a good load distribution to the bone. By its fragile nature, the cement can easily break when it is subjected to a high stress gradient by presenting a craze zone in the vicinity of inclusion. The focus of this study is to analyze the effect of inclusion in some zone of cement in which the loading condition can lead to the crack opening leading to their propagation and consequently the aseptic loosening of the THR. In this study, the fracture behavior of the bone cement including a strange body (bone remain) from which the onset of a crack is supposed. The effect of loading condition, the geometry, the presence of both crack and inclusion on the stress distribution and the fracture behavior of the cement. Results show that the highest stresses are located around the sharp tip of bony inclusion. Most critical cracks are located in the middle of the cement mantle when they are subjected to one leg standing state loading during walking.

Association of a Single Codon Deletion in Bone Morphogenetic Protein 15 Gene with Prolificacy in Small Tail Han Sheep

  • Guo, W.;Chu, M.X.;Deng, X.M.;Feng, J.D.;Li, Ning;Wu, Changxin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.11
    • /
    • pp.1491-1495
    • /
    • 2004
  • Small Tail Han Sheep has significant characteristics of high prolificacy and non-seasonal ovulatory activity and is an excellent local sheep breed in P. R. China. Recently a novel member of the transforming growth factor $\beta$ (TGF$\beta$) superfamily termed bone morphogenetic protein 15 (BMP15) was shown to be specifically expressed in oocytes and to be essential for female fertility. Therefore, BMP15 is a candidate gene for reproductive performance of Small Tail Han Sheep. The whole genomic nucleotide sequence of BMP15 gene in Small Tail Han Sheep was searched for polymorphisms by PCR-SSCP and direct sequencing, and only one polymorphism was found. The polymorphism was a result of a 3 base pair deletion, which eliminated a single Leu codon (CTT). The allelic frequencies for A (without deletion) and B (with a codon deletion) are 0.73 and 0.27 respectively. The effects of BMP15 genotype on litter size were evaluated using the least squares model. This indicated that there was a significant association between litter size of Small Tail Han Sheep and a deletion in BMP15 gene (p=0.02<0.05). Small Tail Han Sheep ewes with AA and AB genotype produce on average 0.5 and 0.3 more lambs per litter than those ewes with BB genotype.

Texture analysis in cone-beam computed tomographic images of medication-related osteonecrosis of the jaw

  • Polyane Mazucatto Queiroz;Karolina Castilho Fardim;Andre Luiz Ferreira Costa;Ricardo Alves Matheus;Sergio Lucio Pereira Castro Lopes
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.109-115
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate changes in the trabecular bone through texture analysis and compare the texture analysis characteristics of different areas in patients with medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: Cone-beam computed tomographic images of 16 patients diagnosed with MRONJ were used. In sagittal images, 3 regions were chosen: active osteonecrosis(AO); intermediate tissue (IT), which presented a zone of apparently healthy tissue adjacent to the AO area; and healthy bone tissue (HT) (control area). Texture analysis was performed evaluating 7 parameters: secondary angular momentum, contrast, correlation, sum of squares, inverse moment of difference, sum of entropies, and entropy. Data were analyzed using the Kruskal-Wallis test with a significance level of 5%. Results: Comparing the areas of AO, IT, and HT, significant differences (P<0.05) were observed. The IT and AO area images showed higher values for parameters such as contrast, entropy, and secondary angular momentum than the HT area, indicating greater disorder in these tissues. Conclusion: Through texture analysis, changes in the bone pattern could be observed in areas of osteonecrosis. The texture analysis demonstrated that areas visually identified and classified as IT still had necrotic tissue, thereby increasing the accuracy of delimiting the real extension of MRONJ.

Effect of Microbial Phytase on Performance, Nutrient Absorption and Excretion in Weaned Pigs and Apparent Ileal Nutrient Digestibility in Growing Pigs

  • Zeng, Z.K.;Piao, X.S.;Wang, D.;Li, P.F.;Xue, L.F.;Salmon, Lorraine;Zhang, H.Y.;Han, X.;Liu, L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.8
    • /
    • pp.1164-1172
    • /
    • 2011
  • Two experiments were conducted to evaluate the efficacy of Trichoderma reesei derived phytase for pigs fed diets with fixed calcium to total phosphorus ratios (1.5:1). In Exp. 1, 280 weaned pigs (initial BW of $10.32{\pm}1.94$ kg) were allocated to one of five dietary treatments on the basis of weight and gender in a randomized complete block design. Treatments were the low phosphorus (0.6% Ca, 0.4% total P and 0.23% available P) diets supplemented with 0, 250, 1,000, or 2,000 FTU phytase/kg of diet and a positive control diet (PC; 0.85% Ca, 0.58% total P and 0.37% available P). The treatments were applied to seven pens with eight pigs per pen, half male and half female. In Exp. 2, six barrows fitted with ileal T-cannula (initial BW = $35.1{\pm}1.6$ kg) were assigned to three dietary treatments with a double $3{\times}3$ Latin square design. The dietary treatments were the low-phosphorus diet (0.53% Ca, 0.34% total P and 0.14% available P), the low phosphorus diet plus 1,000 FTU phytase/kg and a positive control diet (0.77% Ca, 0.50% total P and 0.30% available P). In Exp. 1, there were linear increases (p<0.01) in weight gain, phosphorus absorption, bone strength, calcium and phosphorus content of fat-free dried bone and plasma phosphorus concentrations with increasing dose rate of phytase. The performance of pigs fed the diets with 250, 1,000, or 2,000 FTU of phytase/kg did not differ from pigs fed the PC diet. Pigs fed diets with 1,000 or 2,000 FTU of phytase/kg did not differ from pigs fed the PC diet in bone characteristics. The apparent digestibility of dry matter, crude protein, ash and energy was not affected by dietary treatment. However, pigs fed the PC diet excreted more fecal phosphorus (g/d, p<0.01) and fecal phosphorus per BW gain (g/kg) than pigs fed the diets with phytase. Phytase linearly decreased (p<0.01) fecal phosphorus excreted per BW gain (g/kg), plasma calcium concentration as well as plasma and bone alkaline phosphatase activity. In Exp. 2, phytase supplementation in the low-P diet increased (p<0.05) the apparent ileal digestibility (AID) of Ca, P, leucine, lysine, phenylalanine, alanine and cysteine, tended to AID of crude protein, isoleucine, threonine, asparagine and serine. In conclusion, the novel phytase originated from Trichoderma reesei is effective in releasing Ca, P, and amino acids from corn soy based diet for pigs.

HISTOLOGIC COMPARATIVE STUDY ON THE BONE-IMPLANT INTERFACE OF HYDROXYLAPATITE AND TITANIUM PLASMA SPRAY COATED IMPLANTS (Hydroxylapatite 및 Titanium Plasma Spray 피복임프란트와 골조직 계면의 조직학적 비교 연구)

  • Cho, Ju-Oh;Song, Kwang-Yeob;Park, Charm-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.492-516
    • /
    • 1995
  • This study evaluated the responses of mandibular bones of mongrel dogs to loaded hydro xylapatite(HA) and titanium plasma spray(TPS) coated endosseous dental implants, using unloaded ones as the control group. after HA and TPS coated implants were implanted, their bone reactions with vital bones have been observed with light and scanning electron microscope(SEM) at the three periods of the 4th, 12th and 20th week. These reactions have been also compared in a histomorphometric method. The elemental distribution state of implants and the interface neighboring bone tissues have been measured with the energy dispersive analysis of X-rays(EDAX). The following results were obtained ; 1. The light microscopic analysis showed osseointegration in both the control group and the occlusal force loaded group ; Its degree was shown to be higher in the long-maintained and occlusal force groups. 2. The SEM analysis showed that both groups had osseointegration, In the case of TPS-coated implants, the coated layer was divided on the bone interface. In the case of HA-coated implants, there appeared a division between the metal and coated interface. 3. In the histomorphometric analysis, the measured ratio contaction bone of TPS-coated implants was $70{\pm}19$% in the case of no occlusal force ; it was $84{\pm}13$% in the case of occlusal force. The measured ratio contacting bone of HA-coated implants was $75{\pm}18$% in the case of no occlusal force ; it was $94{\pm}9$% in the case of occlusal force. However, there was no significant difference statistically(p>0.05). 4. Both groups showed that the ratio of calcium and phosphorous increased more in the bone tissues than on the bone to implant interface.

  • PDF