• Title/Summary/Keyword: bone implants

Search Result 1,283, Processing Time 0.03 seconds

Long-term Retrospective Clinical Study Comparing Submerged Type with External Hex Connection and Non-submerged Type with Internal Morse Taper Connection Implants

  • Kwoen, Min-Jeong;Kim, Sang-Yun;Kim, Young-Kyun
    • Journal of Korean Dental Science
    • /
    • v.12 no.1
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose: This study was aimed to compare the survival and success rates, and long-term crestal bone loss according to the use of 2 connection types of dental implants (submerged-USII and non-submerged-SSII; Osstem $Implant^{(R)}$) by analyzing the change in alveolar bone height after 1 year under load and during final follow-up period. Materials and Methods: Between December 2004 and August 2008, patients with two types of Osstem implants (USII and SSII) were retrieved retrospectively. A total of 92 patients with 284 implants (USII=60, SSII=224) was finally selected. Their mean follow-up period was 7.5 years. The mesial and distal alveolar crestal bone changes were measured using radiographic images and the average was calculated at 1 year after loading and during final follow-up period. Result: Among the 284 implants, 4 USII and 7 SSII implants were removed, indicating 93.3% and 96.9% survival rates. Of the survived implants, mean crestal bone loss 1 year after loading was 0.39 mm for USII and 0.19 mm for SSII (P=0.018). During the final follow-up, mean crestal bone loss was 0.63 mm and 0.35 mm for USII and SSII, respectively, without statistical significance (P=0.092). According to the criteria for the success and failure of the implant by Albreksson and colleagues, final success rate was estimated as 86.7% for USII and 91.5% for SSII, respectively. Conclusion At 1 year after loading, the average crestal bone loss was significantly different between USII and SSII; however, both types met the criteria for implant success. During the final follow-up, both groups showed insignificant bone resorption patterns and did not show any pathological clinical symptoms. Therefore, both implants exhibited high long-term stability.

THE LITERATURE REVIEW ON THE SINUS BONE GRAFT USING DEPROTEINIZED BOVINE BONE MINERAL WITH LATERAL APPROACH (탈단백 우골 (Deproteinized Bovine Bone Mineral)을 이용한 상악동 골이식술: 측면 접근법의 문헌 고찰)

  • Hong, Soon-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.5
    • /
    • pp.482-487
    • /
    • 2006
  • As the uses of dental implants are prevailing, the need for sinus bone graft is increasing. Deproteinized bovine bone mineral (DBBM) was not mentioned in 1996 Sinus Bone Graft because of the deficit of the available data. Since then, many clinical and laboratory reports support the use of DBBM in the sinus bone graft procedure. In this report, the histological and clinical successes of sinus bone grafting with DBBM is discussed with available literatures. After sinus bone grafts with DBBM, the proportion of new bone formed was similar or superior to natural maxillary posterior alveolar bone after healing period of 6 months to 1 year. It seems that the grafted DBBM is not be either resorbed nor replaced with bone, but this may not disturb the osseointegration of dental implants installed into it. The clinical survival rates of dental implants installed on the sinus grafted with DBBM was similar to those installed on the ungrafted posterior maxillary alveolar ridge or grafted with autogenous bone. So, it can be concluded that DBBM can be used successfully in the sinus bone graft.

Clinical Study on the Survival Rate and Marginal Bone Resorption of Short Implants (짧은 임플란트의 생존율과 변연골 흡수량에 관한 임상적 연구)

  • Myung, Tae-Soo;Jung, Seung-Hyun;Kim, Tae-Young;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • Short implants are used in parts which have anatomical structures like maxillary sinus, inferior alveolar nerve and limited alveolar height due to severe alveolar bone resorption. In these case, there are no need of additional bone augmentation so there are advantages like reduced entire treatment time, reduced patient's discomfort and protection of important anatomical structures. The aim of this study is, in implants whose length is less than 10mm, to analyze the impact of implant length, diameter, location of implant placement, presence of bone graft, presence of prosthesis splinting on survival rates and marginal bone resorption. The samples used in this study were 227 implants, less than 10mm, placed in 137 patients in Wonkwang university dental hospital implant center. From dental charts the information about implant length, diameter, location of implant placement, presence of bone graft, presence of prosthesis splinting were obtained. Emago advanced v5.6(Oral diagnostic systems, Amsterdam, The Netherlands)program was used to measure the amount of marginal bone resorption. Out of total 227 implants, resulting in 96.5 % of survival rate. There was a tendency toward higher failure rates for the maxilla and bone graft site. No significant difference in marginal bone resorption was found associated with length of implants(p>0.05) and neither with the diameter of implants. Among the risk factors examined, more failure rates of short implants can be attributed to poor bone quality in the maxilla and presence of bone graft. At implants under 10mm, length, diameter, location of implant placement, bone graft and splinting of prosthesis didn't affect marginal bone loss.

Influence of crown-to-implant ratio on periimplant marginal bone loss in the posterior region: a five-year retrospective study

  • Lee, Kyung-Jin;Kim, Yong-Gun;Park, Jin-Woo;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.6
    • /
    • pp.231-236
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the influence of the crown-to-implant (C/I) ratio on the change in marginal bone level around the implant and to determine the site-related factors influencing the relationship between the C/I ratio and periimplant marginal bone loss. Methods: A total of 259 implants from 175 patients were evaluated at a mean follow-up of five years. Implants were divided into two groups according to their C/I ratios: ${\leq}$ 1, and >1. Site-related factors having an influence on the relationship between C/I ratio and periimplant marginal bone loss were analyzed according to the implant location, implant diameter, implant manufacturer, prosthesis type, and guided bone regeneration (GBR) procedure. Results: It was found that 1) implants with a C/I ratio below 1 exhibited greater periimplant marginal bone loss than implants with a C/I ratio more than 1, 2) site-related factors had an effect on periimplant marginal bone loss, except for the implant system used, 3) the C/I ratio was the factor having more dominant influence on periimplant marginal bone loss, compared with implant diameter, prosthesis type, implant location, and GBR procedure, 4) implants with a C/I ratio below 1 showed greater periimplant marginal bone loss than implants with a C/I ratio greater than 1 in the maxilla, but not in the mandible, 5) and periimplant marginal bone loss was more affected by the implant system than the C/I ratio. Conclusions: Within the limitations of this study, implants with a higher C/I ratio exhibited less marginal bone loss than implants with a lower C/I ratio in the posterior regions. The C/I ratio was a more dominant factor affecting periimplant marginal bone loss in the maxilla than the mandible. Meanwhile, the implant system was a more dominant factor influencing periimplant marginal bone loss than the C/I ratio.

Marginal bone loss around crestal or subcrestal dental implants: prospective clinical study

  • Sargolzaie, Naser;Zarch, Hosein Hoseini;Arab, Hamidreza;Koohestani, Tahereh;Ramandi, Mahdiye Fasihi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.3
    • /
    • pp.159-166
    • /
    • 2022
  • Objectives: The stability of crestal bone has been reported as a major factor in the success of dental implants. Implants can be placed in an equicrestal (crestal) or subcrestal position. The aim of this study was to evaluate the effect of implant depth placement on marginal bone loss. Materials and Methods: The study was created in a split-mouth design. Immediately after implant surgery, digital parallel radiographs were prepared and levels of bone were measured where marginal bone loss and bone level changes occurred. These measurements were repeated at 3-month and 6-month follow-up periods. Results: In this interventional study, 49 implants were evaluated in 18 patients. Primary bone height was not significant between the intervention and control groups in both mesial and distal aspects at 3 months and 6 months from the baseline. The mean marginal bone loss on the mesial side was 1.03 mm in the subcrestal group and 0.83 mm in the crestal group. In addition, mean marginal bone loss on the distal side was 0.88 mm and 0.81 mm in the subcrestal and crestal groups, respectively. Marginal bone loss was not significantly different between sexes, the maxilla or mandible, and in the anterior or posterior regions as well as between different lengths and diameters of implants. Conclusion: Based on the results of this study, there was no significant difference in terms of marginal bone loss between crestal and subcrestal implants.

EFFECTS OF EARLY FUNCTIONAL LOADING ON BONE FORMATION AROUND TITANIUM PLASMA SPRAYED IMZ IMPLANTS IN DOGS (성견에서 Titanium Plasma Sprayed IMZ 임플란트에 가해진 조기 기능하중의 골유착 및 골형성에 미치는 영향)

  • Jeon, Young-Sik;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.550-568
    • /
    • 1995
  • The purpose of this study was to observe the effects of early functional on bone formation around titanium plsama sprayed IMZ implants. 15 IMZ implants were inserted on the mandibular premolar areaa in 5 mondgrel dogs. The inplants were divided into 4 groups according to it’s loading schedule : Temporary abutments were connected for functional loading 6weeks, 9weeks, and 12weeks after implants installation in group I, II, and III, respectively. Abutments were not connected in the control group. After polyfluorochrome sequential labeling, all animals were sacrificed and bone sections includig implants and the 1st. molar were removed and processed for histologic evaluation. From light and fluorescence microscopic evaluation as well as histomorphometric and EPMA analysis, following results were obtained : 1. Light microscopically, the osteoid tissues were observed much in the compact bone of unloaded group, and cancellous bone formation observed more in early loaded group. 2. Calcification and remodeling of bone took place faster in loaded group, especially in 6 weeks group. 3. Moderate to severe marginal bone resorption was observed in 6 weeks group, mainly on buccal crest. 4. There was no difference in the percentages of bone-to-metal contact among the experimental groups. 5. In quantitative analysis using EPMA, there was no difference in the content of calcium and phosphorus among the experimental groups, regardless of distance.

  • PDF

Assessment of trabecular bone changes around endosseous implants using image analysis techniques: A preliminary study

  • Zuki, Mervet El;Omami, Galal;Horner, Keith
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.129-135
    • /
    • 2014
  • Purpose: The objective of this study was to assess the trabecular bone changes that occurred around functional endosseous dental implants by means of radiographic image analysis techniques. Materials and Methods: Immediate preoperative and postoperative periapical radiographs of de-identified implant patients at the University Dental Hospital of Manchester were retrieved, screened for specific inclusion criteria, digitized, and quantified for structural elements of the trabecular bone around the endosseous implants, by using image analysis techniques. Data were analyzed using SPSS version 11.5. P values of less than 0.05 were considered statistically significant. Results: A total of 12 implants from 11 patients were selected for the study, and 26 regions of interest were obtained. There was a significant increase in the bone area in terms of the mean distance between nodes (p=0.006) and a significant decrease in the marrow area in terms of the bone area (p=0.006) and the length of marrow spaces (p=0.032). Conclusion: It appeared that the bone around the implant underwent remodeling that resulted in a net increase in bone after implant placement.

Removal Torque and Histomorphometric Investigation of Surface Modified Commercial Implants: An Experimental Study in the Rabbit Tibia (상용화된 치과용 임플란트의 뒤틀림 제거력 및 조직학적 분석 연구: 가토 경골에서의 연구)

  • Park, Jong-Hyun;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.41-56
    • /
    • 2008
  • The methods of surface modification of commercial implants were various according to the manufacturer. Surface modification of implant may produce diverse physical and chemical surface characteristics resulted from the treatment method and treatment condition. As a result, the bone response might be different. Even though surface modified implants have been used clinically, most researches are focusing on the bone response of surface modified implants comparing to machined implants rather than surface modified commercial implants. This study compare and analyze bone responses of 4 surface modified commercial implants with different shapes and surfaces. Eighty surface modified commercial implants with 4 different surface characteristics were installed in the tibia of white Newzealand rabbits. Biomechanical stability tests and histomorphometric evaluation were done. The results were as follows: 1. Surface modified commercial implants showed stable osseointegration at 6 weeks after installation. 2. Histomorphometric evaluation showed that there was no significant differences in bone to implant contact among 4 different commercial titanium implants. In comparing the implants with different shape the measurement of bone growth in subcortical area would be more reliable than entire bone to implant contact length. 3. Resonance Frequency Analysis showed that there was no significant differences among 4 types of implants, even though they were significantly different in installation. 4. There was significant differences in interfacial shear strength among 4 type of implants. 5. It is difficult to observe accurate bone to implant interface using Micro-CT. However, it is possible to measure the entire contact length of the implant to the bone.

Marginal bony changes in relation to different vertical positions of dental implants

  • Yi, Jung-Myung;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok;Lee, Min-Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.5
    • /
    • pp.244-248
    • /
    • 2010
  • Purpose: The purpose of this study was to radiographically evaluate marginal bony changes in relation to different vertical positions of dental implants. Methods: Two hundred implants placed in 107 patients were examined. The implants were classified by the vertical positions of the fixture-abutment connection (microgap): 'bone level,' 'above bone level,' or 'below bone level.' Marginal bone levels were examined in the radiographs taken immediately after fixture insertion, immediately after second-stage surgery, 6 months after prosthesis insertion, and 1 year after prosthesis insertion. Radiographic evaluation was carried out by measuring the distance between the microgap and the most coronal bone-to-implant contact (BIC). Results: Immediately after fixture insertion, the distance between the microgap and most coronal BIC was $0.06{\pm}0.68\;mm$; at second surgery, $0.43{\pm}0.83\;mm$; 6 months after loading, $1.36{\pm}0.56\;mm$; and 1 year after loading, $1.53{\pm}0.51\;mm$ ($mean{\pm}SD$). All bony changes were statistically significant but the difference between the second surgery and the 6-month loading was greater than between other periods. In the 'below bone level' group, the marginal bony change between fixture insertion and 1 year after loading was about 2.25 mm, and in the 'bone level' group, 1.47 mm, and in 'above bone level' group, 0.89 mm. Therefore, the marginal bony change was smaller than other groups in the 'above bone level' group and larger than other groups in the 'below bone level' group. Conclusions: Our results demonstrated that marginal bony changes occur during the early phase of healing after implant placement. These changes are dependent on the vertical positions of implants.

Tilted implants for implant-supported fixed hybrid prostheses: retrospective review

  • Woo-Hyun Seok;Pil-Young Yun;Na-Hee Chang;Young-Kyun Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.5
    • /
    • pp.278-286
    • /
    • 2023
  • Objectives: This review assessed the performance of implant-supported fixed hybrid prostheses in 21 patients who received a total of 137 implants between 2003 and 2010. The implants were evaluated for marginal bone resorption, complications, success rate, and survival rate based on their vertical angularity, type of bone graft, and measured implant stability. Materials and Methods: One-way ANOVA and chi-square tests were used to analyze the relationships among long-term evaluation factors and these variables. The mean initial bone resorption in the implant group with a vertical angle of more than 20° was 0.33 mm and mean final bone resorption was 0.76 mm. In contrast, the mean initial bone resorption in the implant group with a vertical angle of less than 10° was 1.19 mm and mean final bone resorption was 2.17 mm. Results: The results showed that mean bone resorption decreased with an increase in the vertical placement angle of the implants used in fixed hybrid prostheses, as well as in the group without additional bone grafts and those with high implant stability. The success rate of implants placed after bone grafting was found to be higher than those placed simultaneously. Conclusion: These results suggest that implant-supported fixed hybrid prostheses may be an effective treatment option for edentulous patients, and intentionally placing implants with high angularity may improve outcomes.