• Title/Summary/Keyword: bone SPECT

Search Result 47, Processing Time 0.024 seconds

Assessment of Vascularization within Hydroxyapatite Ocular Implant by Bone Scintigraphy: Comparative Analysis of Planar and SPECT Imaging (Hydroxyapatite 안구보충물삽입술 후 골신티그라피를 이용한 섬유혈관증식 평가: 평면영상과 SPECT 영상에서의 비교)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Park, Soon-Ah
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.475-483
    • /
    • 1999
  • Purpose: Complete fibrovascular ingrowth within the hydroxyapatite ocular implant is necessary for peg drilling which is performed to Prevent infection and to provide motility to the ocular prosthesis. We compared planar bone scintigraphy and SPECT for the evaluation of the vascularization within hydroxyapatite ocular implants. Materials and Methods: Seventeen patients (M:F: 12:5, mean age; $50.4{\pm}17.5$ years) who had received a coralline hydroxyapatite ocular implant after enucleation surgery were enrolled. Patients underwent Tc-99m MDP planar bone and SPECT imaging by dual head gamma camera after their implant surgery (interval: $197{\pm}81$ days). Uptake on planar and SPECT images was graded visually as less than (grade 1), equal to (grade 2), and greater than (grade 3) nasal bridge activity. Quantitative ratio of implanted to non-implanted intraorbital activity was also measured. Vascularization within hydroxyapatite implants was confirmed by slit lamp examination and ocular movement. Results: All but three patients were considered to be vascularized within hydroxyapatite implants. In visual analysis of planar image and SPECT, grade 1 was noted in 9/18 (50%) and 6/18 (33%), respectively. Grade 2 pattern was 7/18 (39%) and 4/18 (22%), and grade 3 pattern was 2/18 (11%) and 8/18 (44%) respectively. When grade 2 or 3 was considered to be positive for vascularization, the sensitivity of planar and SPECT imaging were 60% (9/15) and 80% (12/15), respectively. In 3 patients with incomplete vascularization, both planar and SPECT showed grade 1 uptake The orbital activity ratios on planar imaging were not significantly different between complete and incomplete vascularization ($1.96{\pm}0.87$ vs $1.17{\pm}0.08$, p>0.05), however, it was significantly higher on SPECT in patients with complete vascularization ($8.44{\pm}5.45$ vs $2.20{\pm}0.87$, p<0.05). Conclusion: In the assessment of fibrovascular ingrowth within ocular implants by Tc-99m MDP bone scintigraphy, SPECT image appears to be more effective than planar scintigraphy.

  • PDF

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

Evaluation of Radiation Exposure to Medical Staff except Nuclear Medicine Department (핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가)

  • Lim, Jung Jin;Kim, Ha Kyoon;Kim, Jong Pil;Jo, Sung Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.32-35
    • /
    • 2016
  • Purpose The goal for this study is to figure out that medical staff except Nuclear Medicine Department could be exposed to radiation from the patients who take Nuclear Medicine examination. Materials and Methods Total 250 patients (Bone scan 100, Myocardial SPECT 100, PET/CT 50) were involved from July to October in 2015, and we measured patient dose rate two times for every patients. First, we checked radiation dose rate right after injecting an isotope (radiopharmaceutical). Secondly, we measured radiation dose rate after each examination. Results In the case of Bone scan, dose rate were $0.0278{\pm}0.0036mSv/h$ after injection and $0.0060{\pm}0.0018mSv/h$ after examination (3 hrs 52 minutes after injection on average). For Myocardial SPECT, dose rate were $0.0245{\pm}0.0027mSv/h$ after injection and $0.0123{\pm}0.0041mSv/h$ after examination (2 hrs 09 minutes after injection on average). Lastly, for PET/CT, dose rate were $0.0439{\pm}0.0087mSv/h$ after examination (68 minutes after injection on average). Conclusion Compared to Nuclear Safety Commission Act, there was no significant harmful effect of the exposure from patients who have been administered radiopharmaceuticals. However, we should strive to keep ALARA(as low as reasonably achievable) principle for radiation protection.

  • PDF

Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy (검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가)

  • Kang, Young-Eun;Jung, Woo-Young;Hong, Bo-Ruem
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Purpose An examination guide is a useful medium to provide the patient with an overview, pre- and post-test preparation, and precautions of nuclear testing. The design and arrangement of existing written texts and announcements were evaluated to elucidate the comprehension of patients undergoing testing. Materials and Methods Informational material describing bone scanning and $^{201}thallium$ myocardium perfusion single-photon emission computed tomography (SPECT), as a secondary examination, which accounts for the largest portion of gamma imaging at Asan Hospital (Seoul, South Korea), was selected as an improvement target in consultation with a national innovation center. Existing informational material was dispensed to patients scheduled for bone scans from November 2016 to February 2017 and the revised material was issued from March 2017 to May 2017. A survey was conducted of 200 patients who underwent $^{201}thallium$ myocardium perfusion SPECT before and after the revisions (n = 100 each time period) to assess the patients' understanding of the informational material. Results When comparing the use of the conventional vs. revised material, the number of patients who received treatment before bone scanning had decreased from 130 to 60, while the number of those who required additional imaging decreased from 53 to 14. Prior to the revision, 43% of patients underwent testing before preparation and 18% underwent additional testing. The decreased need for additional image acquisition after revision of the informational material resulted in a decrease in acquisition time of about 2 min, from 16.5 to 14.2 min. In the case of $^{201}thallium$ myocardium perfusion SPECT, patient comprehension of all five items surveyed had increased, while the number of patients who had repeatedly asked about various facets of the procedure pre- and post-testing had decreased from 36% to 16% and 31% to 14%, respectively. Conclusion Lower patient comprehension is accompanied by a decrease in image quality due to non-compliance during pre-testing and may lead to repetitive questions from the patient, which may also negatively affect the fatigue and work efficiency of the examiner. Improved readability and visibility of informational material through visualization was correlated with greater patient comprehension as well as improved image quality and acquisition time.

Usefulness of "Volumetrix Suite" with SPECT/CT (SPECT/CT 영상에서 Volumetrix Suite의 유용성)

  • Cho, Seung-Wook;Shin, Byeong-Ho;Kim, Jong-Pil;Yoon, Seok-Hwan;Kim, Tae-Yeub;Seung, Yong-Joon;Moon, Il-Sang;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.166-171
    • /
    • 2010
  • Purpose: The SPECT/CT is able to acquire diagnostic information resolved the difficult problems that discriminate regions of focals by intergrating functional images and anatomical images. We introduce the usefulness of "Volumetrix Suite" which can describe 3D images by the convergence of the SPECT/CT images and reference CT images. Materials and Methods: We applied Volumetrix Suite program (Volumetrix IR, Volumetrix 3D) to patients, Bone, Venography, Parathyroid, WBC, taken diagnostic CT examination which have same regions of focal in Seoul Metropolitan Government Seoul National University Boramae Medical Center. After acquiring SPECT/CT images and reference CT images, we fused a couple of scans applying for this programs. The CT scan of Infinia Hawkeye 4 shows limitation of anatomical information. For this reason, we tried to transfer CT images that have lots of diagnostic informations as the form of Dicom file in PACS, and changed from 2D images to 3D images after image registering in Xeleris Workstaion of Hawkeye 4. Results & Conclusion: By using Volumetrix Suite program, we're able to acquire more accurate anatomical informations with 3D rendering which can distinguish both location and range of focals in Infinia Hawkeye 4. Thus, the result of utilizing this program indicate that nuclear medicine anatomical images can be improved by providing more diagnostic imformations produced by its program.

  • PDF

Osteoporotic Vertebral Fractures: SPECT Findings (골다공증에 동반된 척추골절의 골 SPECT 소견)

  • Baik, Jun-Hyun;Park, Young-Ha;Ihn, Yon-Kwon;Kim, Sung-Hoon;Chung, Yong-An;Yoo, Ie-Ryung;Kim, Jee-Yeung;Jung, Hyun-Seok;Sohn, Hyung-Seon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.522-527
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate the usefulness of single photon emission computed tomography (SPECT) of bone using Tc-99m MDP in the diagnosis of osteoporotic vertebral fractures. Materials and Methods: Thirty two patients with osteoporotic vertebral fracture were included in this study (mean age: $67{\pm}8$, male: 5, female: 27). Seventy nine vertebral fractures were detected (38 thoracic/thoracolumbar lesions and 41 lumbar lesions), which were classified by type of deformity (wedge, biconcave or compression). The patterns and locations of increased uptakes were examined and analyzed. Results: Forty seven wedge fractures, 20 biconcave fractures and 12 compression fractures were found. Diffuse and asymmetric uptakes were common in fractured bodies. More than one uptake were examined in 69 posterior elements of fractured vertebrae (87.3%) including 40 of 47 wedge fractures (85.1%), 17 of 20 biconcave fractures (85.0%) and 12 of 12 compression fractures (100%). Wedge fractures were predominant fracture in thoracic/thoracolumbar spine whereas incidence of biconcave or compression type war similar to that of wedge fracture in lumbar spine (p=0.04). Spinous process uptake was more frequently seen in lumbar lesions than thoracic/thoracolumbar lesions (p=0.009). Facet joint uptake in biconcave fracture was more common in lumbar spine (92.3%) than thoracic/thoracolumbar spine (57.1%). Spinous process uptake in biconcave fracture was also more frequently detected in lumbar spine (p=0.043). Conclusion: Bone SPECT was useful in the evaluation of osteoporotic vertebral fracture, especially posterior elements of vertebrae.

The Usefulness of Bone Scintigraphy in SAPHO Syndrome (SAPHO 증후군에서 골신티그라피의 유용성)

  • Lim, Seok-Tae;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.255-260
    • /
    • 2002
  • Purpose: SAPHO syndrome is well known to various disease entities including synovitis, acne, pustulosis, hyperostosis and polyarthritis. The purpose of this study is to evaluate sicntigraphic findings and to compare with radiologic findings in SAPHO syndrome. Materials and Methods: Five patients (M:F=5.0, Age $22.8{\pm}4.78$ yrs) with SAPHO syndrome were enrolled in our study. All patients underwent whole-body bone scintigraphy with intravenous administration of 740 MBq of Tc-99m MDP. Among them, two patients were additionally perfomed SPECT of the spine to evaluate the location and extort of spinal lesion. Results: All patients were demonstrated abnormal increased uptakes in sternoclavicular joint (SC), sacroiliac joint (SI), and small joints of both hands. Among them, three patients were bilateral involvement (3/5) and two were unilateral (2/5) in SC. involvement of SI showed bilateral in four patients (4/5) and unilateral in one (1/5). SPECT images demonstrate that the lesion sites of the lumbar spine are more likely facet joints than vertebral bodies or pedicles. Conclusion: As SAPHO syndrome is the disease entity involved polyarticular joints with various dermatologic manifestations, the bone scintigraphy may be a very useful method to evaluate the location and extent of joint involvement, and to avoid inadequate surgical management or ineffective antibiotic treatment.