• 제목/요약/키워드: bonding glass

검색결과 429건 처리시간 0.027초

섬유보강 철근콘크리트 보의 전단강도에 대한 실험적 연구 (An Experimental Study on Shear Strength of Reinforced Concrete Beams Strengthened by Fiber Reinforced Polymer)

  • 황현복;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.371-374
    • /
    • 2005
  • The research reported in this paper provides the test results of eleven reinforced concrete beams strengthened with FRP composites. Three parameters were considered in this investigation: the amount of FRP composites, the types of bonding schemes(continuous sheets or strips), and the material types of FRP composites (Carbon or Glass). The experimental results indicated that because the rupture strain of FRP composites was relatively higher that the yield strain of steel bars, the RC beams strengthened with FRP composites failed due to concrete crushing before the FRP composites arrived at its rupture strain. The compatibility-aided truss model showed reasonable agreement between the predicted and experimental shear stress-strain curves of the beams throughout the entire loading history.

  • PDF

Epi poly를 이용한 MEMS 소자용 웨이퍼 단위의 진공 패키징에 대한 연구 (A Study on Wafer Level Vacuum Packaging using Epi poly for MEMS Applications)

  • 석선호;이병렬;전국진
    • 반도체디스플레이기술학회지
    • /
    • 제1권1호
    • /
    • pp.15-19
    • /
    • 2002
  • A new vacuum packaging process in wafer level is developed for the surface micromachining devices using glass silicon anodic bonding technology. The inside pressure of the packaged device was measured indirectly by the quality factor of the mechanical resonator. The measured Q factor was about 5$\times10^4$ and the estimated inner pressure was about 1 mTorr. And it is also possible to change the inside pressure of the packaged devices from 2 Torr to 1 mTorr by varying the amount of the Ti gettering material. The long-term stability test is still on the way, but in initial characterization, the yield is about 80% and the vacuum degradation with time was not observed.

  • PDF

주파수와 대역폭 조정이 가능한 bandstop 공진기 (Frequency and bandwidth tuneable bandstop resonator)

  • ;김정무;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2392-2394
    • /
    • 2005
  • This paper presents a tuneable bandstop resonator with two possible configurations, it can be used to tune its center frequency, or it can be used to tune its bandwidth. The tuneable bandstop resonator has potential application in microwave communications receivers, where it can be used to tune out interfering signals. The proposed resonator is comb actuated, where the resonator's displacement produces different values of frequency or bandwidth, this is achieved by decoupling electromagnetic energy from a main transmission line. The proposed fabrication process for the resonator is by anodic bonding pyrex glass and tow resistivity silicon, where the comb resonator structure is patterned by deep reactive ion etching (DRIE). This paper presents the resonator and actuator design in both configurations, as well as the fabrication process intended for its development.

  • PDF

역류방지형 유리계 마이크로 펌프 개발 (Development of Backflow prevented Micropump)

  • 최종필;조기철;김헌영;김병희
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.229-232
    • /
    • 2005
  • This paper presents the design and fabrication of backflow prevented Micropump using the metal membrane. The Micropump is consisted of the lower plate, metal membrane, upper plate and the piezoelectric-element. The lower plate includes the micro channel and the inlet, outlet of the Micropump. The upper plate includes the micro channel and connects the piezoelectric-element. These plate are fabricated on the Pyrex glass wafer by sandblasting process. The metal membrane does roll of check valve that is prevented backflow of the Micropump. The metal membrane is fabricated on the stainless steel by laser machining. Piezoelectric-element is actuated the Micropump and controlled flowing of fluid. The Micropump is fabricated by bonding process of these multi-layer.

  • PDF

ACA COG의 접합특성에 대한 고온시효의 영향 (The effect of High Temperature Aging on the Bonding Characteristics of ACA COG)

  • 한정인;홍성제
    • 한국재료학회지
    • /
    • 제6권11호
    • /
    • pp.1146-1152
    • /
    • 1996
  • 실제 사용시 신뢰성을 보장하기 위하여, 고온에서 장시간 동안의 시효로 인한 ACA COG(Anisotropic Conductive Chip On Glass) 접합 특성의 변화가 연구되었다. 모든 접합 시편들은 16$0^{\circ}C$에서 156시간 동안 유지되었고 시효하는 동안의 접촉저항의 변화는 감소하였다. 특히, 156시간이후, 4000개 /$\textrm{mm}^2$의 입자밀도를 가진 ACA에서는 접촉저항의 벼노하가 나타나지 않았다. 입자크기의 경우 작은 입자를 가진 ACA는 16$0^{\circ}C$에서 시효후에도 접촉저항의 변화를 보이지 않았다. 또한 4000개/$\textrm{mm}^2$ 및 5$\mu\textrm{m}$ 입자를 가진 ACA를 사용한 시편은 접합상태가 안정하였기 때문에 16$0^{\circ}C$에서도 경화수지의 팽창 및 리플로우(reflow)에 의한 영향을 받지 않았다. 따라서 이 ACA에서는 16$0^{\circ}C$에서 156시간 동안 시효한 후에도 오픈(open)이 나타나지 않았다.

  • PDF

Hydrolytic stability of novel silane coupling agents with phenyl group

  • NiHeil, T.;Kuratal, S.;Ohashi, K.;Omotol, N.;Kondo, Y.;Memoto, K.U;Yoshino, N.;Teranaka, T.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.605-605
    • /
    • 2003
  • Novel silane coupling agents containing hydrophobic phenyl group 3-(3-methoxy-4-methacryloyloxyphenyl) propyl-trimethoxysilane(p-MPS), -triisocyanatesilane (p-MBI), -trichlorosilane (p-MBC) were synthesized. The bonding durability of these silanes against water immersion and thermal stress was investigated. 3-methacryloyloxypropyltrimethoxysilane (3-MPG) was used as a control. The glass modified with those silanes at a concentration of 2wt% were kept for 3 minutes at $120^{\circ}C$, and then were bonded to the heaped metal with self-cured resin composite.(omitted)

  • PDF

Plasticization in Unclustered Poly(methyl methacrylate) Ionomers

  • 김준섭;김희석;Adi Eisenberg
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권6호
    • /
    • pp.625-628
    • /
    • 1998
  • The dynamic mechanical properties of the unclustered cesium neutralized poly(methyl methacrylate-co-methacrylic acid) ionomers plasticized with three different plasticizers of low molecular weight were investigated. It was found that the effectiveness of the plasticization followed the order: glycerol (Gly) 4-decylaniline (4DA) >dioctyl phthalate (DOP). For the ionomer plasticized with Gly, the only effect was a significant decrease in the Tg. Thus it is concluded that the polar plasticizer not only increases the mobility of the ionomer but also dissolves the ionic groups. In the case of the 4DA-plasticized ionomer, both a drastic decrease in the Tg and the appearance of a second glass transition were observed. Therefore, it is suggested that the nonpolar 4DA molecules partition evenly in the poly(methyl methacrylate) matrix and cluster phases via hydrogen bonding between the aniline group of the plasticizer and the carbonyl groups of the ionomer. As a result, the Tg is lowered, multiplets can form, and the material behaves like a clustered ionomer.

Experimental analysis of damage in short-fiber-reinforced composite waste polyethylene terephthalate as a pile foundation material

  • Jang, Hongseok;Seo, Segwan;Cho, Daesung
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.147-157
    • /
    • 2022
  • This study assessed the compressive and tensile strengths and modulus of elasticity of waste polyethylene terephthalate (PET) using the ASTM standard tests. In addition, short carbon and glass fibers were mixed with waste PET to examine the improvements in ductility and strength during compression. The bonding was examined via field-emission scanning electron microscopy. The strength degradation of the waste PET tested under UV was 40-50%. However, it had a compressive strength of 32.37 MPa (equivalent to that of concrete), tensile strength of 31.83 MPa (approximately ten times that of concrete), and a unit weight of 12-13 kN/m3 (approximately half that of concrete). A finite element analysis showed that, compared with concrete, a waste PET pile foundation can support approximately 1.3 times greater loads. Mixing reinforcing fibers with waste PET further mitigated this, thereby extending ductility. Waste PET holds excellent potential for use in foundation piles, especially while mitigating brittleness using short reinforcing fibers and avoiding UV degradation.

상아질 접착 지각과민 처치제에 대한 치수반응에 관한 연구 (A STUDY ON THE HUMAN PULPAL RESPONSE TO DENTIN BONDING DESENSITIZER)

  • 유희승;이성복;우이형;박남수;최부병
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.483-495
    • /
    • 1998
  • The purpose of this study was to evaluate the human pulpal response to Dentin Bonding Desensitizer. Class V cavities were prepared on the buccal surfaces of the first premolars and Dentin Bonding Desensitizer(ALL-BOND Desensitizer, Bisco, Inc. U.S.A.) was applicated in ten experimental teeth, or ZOE(PROPAC, GC Co. TOKYO, JAPAN) cement in eight control teeth and cavities were filled with light curing glass ionomer(Fuji II LC, GC Co., TOKYO, JAPAN). At 3-day and 25-day postoperative interval. pulpal response was observed and evaluated histologically with light microscope. The results were as follows. ; 1. At 3-day postoperative interval, the control teeth were grade 1 inflammatory cell response and grade 1 connective tissue response. 2. At 25-day postoperative interval, all control teeth were grade 1 inflammatory cell response and in three control teeth grade 1 connective tissue response were observed, and one teeth showed grade 2 connective tissue response. 3. At 3-day postoperative interval, the experimental teeth were grade 1 inflammatory cell response and grade 1 connective tissue response. Below the cavity, a few inflammatory cell(PMNs) in odontoblastic layer, increased blood vessels and pulpal cells were seen and this pulpal response was similar to control teeth. 4. At 25-day postoperative interval, in four experimental teeth grade 1 inflammatory cell response and grade 1 connective tissue response were observed, and one experimental teeth showed mild inflammatory response. 5. At 3-day and 25-day postoperative interval, no reparative dentin deposition was seen. 6. Both experimental and control group, pulpal response showed difference between 3 and 25-day of postoperative interval. In control teeth, increased predentin and pulpal cells were seen and in experimental teeth, congestion of blood vessels and increased pulpal cells were seen. In conclusion, the pulpal irritation due to this Dentin Bonding Desensitizer was not severe, and it was considered that the agent was not harmful to the human pulp.

  • PDF

Forced Potential Scheme 미세 가열기를 이용한 부분 가열 저온 Hermetic 패키징 (Low Temperature Hermetic Packaging by Localized Heating using Forced Potential Scheme Micro Heater)

  • 심영대;신규호;좌성훈;김용준
    • 마이크로전자및패키징학회지
    • /
    • 제10권2호
    • /
    • pp.1-5
    • /
    • 2003
  • 기존 형상의 미세 가열기를 이용한 마이크로 시스템 패키징의 문제점을 해결하기 위해 새로운 형상의 미세 가열기를 제작하여 패키징 실험을 시행하였다. 기존 형상의 미세 가열기와 새로운 미세 가열기의 형상을 각각 제작하여 접합시에 미세 가열기에 발생하는 열분포를 IR카메라를 이용하여 실험하였다. 기존 형상의 미세 가열기가 불균일하게 가열되는 반면, 새로운 형상의 미세 가열기는 매우 균일하게 가열되는 형상을 나타내었고, IR 카메라를 이용한 실험 결과를 바탕으로 각기 다른 형상의 미세 가열기를 이용하여 접합 실험을 실시하였다. 접합 실험시 사용한 미세 가열기는 폭 $50{\mu}m$, 두께 $2{\mu}m$로 제작하였으며, 0.2Mpa 의 압력을 Pyrex glass cap에 가한 상태에서 150mA의 전류를 공급하여 접합을 완료하였다. 접합이 완료된 시편들에 대해서 IPA를 통한 leakage check실험을 실시하였으며, 기존 형상의 미세 가열기를 이용한 시편들은 66%가 테스트를 통과한 반면 새로운 형상의 미세 가열기를 이용한 시편들은 85%이상이 테스트를 통과하였다. Leakage 실험을 통과한 각각의 시편들에 대해서 접합력 측정을 실시한 결과, 기존 형상의 미세 가열기를 이용한 시편들은 15∼21Mpa의 접합력을 나타내었고, 새로운 형상의 미세 가열기를 이용한 시편들은 25∼30Mpa의 우수한 접합력을 나타내었다.

  • PDF