• Title/Summary/Keyword: bonding glass

Search Result 429, Processing Time 0.022 seconds

An Experimental Study on Shear Strength of Reinforced Concrete Beams Strengthened by Fiber Reinforced Polymer (섬유보강 철근콘크리트 보의 전단강도에 대한 실험적 연구)

  • Hwang Hyun-Bok;Lee Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.371-374
    • /
    • 2005
  • The research reported in this paper provides the test results of eleven reinforced concrete beams strengthened with FRP composites. Three parameters were considered in this investigation: the amount of FRP composites, the types of bonding schemes(continuous sheets or strips), and the material types of FRP composites (Carbon or Glass). The experimental results indicated that because the rupture strain of FRP composites was relatively higher that the yield strain of steel bars, the RC beams strengthened with FRP composites failed due to concrete crushing before the FRP composites arrived at its rupture strain. The compatibility-aided truss model showed reasonable agreement between the predicted and experimental shear stress-strain curves of the beams throughout the entire loading history.

  • PDF

A Study on Wafer Level Vacuum Packaging using Epi poly for MEMS Applications (Epi poly를 이용한 MEMS 소자용 웨이퍼 단위의 진공 패키징에 대한 연구)

  • 석선호;이병렬;전국진
    • Journal of the Semiconductor & Display Technology
    • /
    • v.1 no.1
    • /
    • pp.15-19
    • /
    • 2002
  • A new vacuum packaging process in wafer level is developed for the surface micromachining devices using glass silicon anodic bonding technology. The inside pressure of the packaged device was measured indirectly by the quality factor of the mechanical resonator. The measured Q factor was about 5$\times10^4$ and the estimated inner pressure was about 1 mTorr. And it is also possible to change the inside pressure of the packaged devices from 2 Torr to 1 mTorr by varying the amount of the Ti gettering material. The long-term stability test is still on the way, but in initial characterization, the yield is about 80% and the vacuum degradation with time was not observed.

  • PDF

Frequency and bandwidth tuneable bandstop resonator (주파수와 대역폭 조정이 가능한 bandstop 공진기)

  • Liamas-Garro, Ignacio;Kim, Jung-Mu;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2392-2394
    • /
    • 2005
  • This paper presents a tuneable bandstop resonator with two possible configurations, it can be used to tune its center frequency, or it can be used to tune its bandwidth. The tuneable bandstop resonator has potential application in microwave communications receivers, where it can be used to tune out interfering signals. The proposed resonator is comb actuated, where the resonator's displacement produces different values of frequency or bandwidth, this is achieved by decoupling electromagnetic energy from a main transmission line. The proposed fabrication process for the resonator is by anodic bonding pyrex glass and tow resistivity silicon, where the comb resonator structure is patterned by deep reactive ion etching (DRIE). This paper presents the resonator and actuator design in both configurations, as well as the fabrication process intended for its development.

  • PDF

Development of Backflow prevented Micropump (역류방지형 유리계 마이크로 펌프 개발)

  • Choi J. P.;Cho K. C.;Kim H. Y.;Kim B. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.229-232
    • /
    • 2005
  • This paper presents the design and fabrication of backflow prevented Micropump using the metal membrane. The Micropump is consisted of the lower plate, metal membrane, upper plate and the piezoelectric-element. The lower plate includes the micro channel and the inlet, outlet of the Micropump. The upper plate includes the micro channel and connects the piezoelectric-element. These plate are fabricated on the Pyrex glass wafer by sandblasting process. The metal membrane does roll of check valve that is prevented backflow of the Micropump. The metal membrane is fabricated on the stainless steel by laser machining. Piezoelectric-element is actuated the Micropump and controlled flowing of fluid. The Micropump is fabricated by bonding process of these multi-layer.

  • PDF

The effect of High Temperature Aging on the Bonding Characteristics of ACA COG (ACA COG의 접합특성에 대한 고온시효의 영향)

  • Han, Jeong-In;Hong, Seong-Je
    • Korean Journal of Materials Research
    • /
    • v.6 no.11
    • /
    • pp.1146-1152
    • /
    • 1996
  • 실제 사용시 신뢰성을 보장하기 위하여, 고온에서 장시간 동안의 시효로 인한 ACA COG(Anisotropic Conductive Chip On Glass) 접합 특성의 변화가 연구되었다. 모든 접합 시편들은 16$0^{\circ}C$에서 156시간 동안 유지되었고 시효하는 동안의 접촉저항의 변화는 감소하였다. 특히, 156시간이후, 4000개 /$\textrm{mm}^2$의 입자밀도를 가진 ACA에서는 접촉저항의 벼노하가 나타나지 않았다. 입자크기의 경우 작은 입자를 가진 ACA는 16$0^{\circ}C$에서 시효후에도 접촉저항의 변화를 보이지 않았다. 또한 4000개/$\textrm{mm}^2$ 및 5$\mu\textrm{m}$ 입자를 가진 ACA를 사용한 시편은 접합상태가 안정하였기 때문에 16$0^{\circ}C$에서도 경화수지의 팽창 및 리플로우(reflow)에 의한 영향을 받지 않았다. 따라서 이 ACA에서는 16$0^{\circ}C$에서 156시간 동안 시효한 후에도 오픈(open)이 나타나지 않았다.

  • PDF

Hydrolytic stability of novel silane coupling agents with phenyl group

  • NiHeil, T.;Kuratal, S.;Ohashi, K.;Omotol, N.;Kondo, Y.;Memoto, K.U;Yoshino, N.;Teranaka, T.
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.605-605
    • /
    • 2003
  • Novel silane coupling agents containing hydrophobic phenyl group 3-(3-methoxy-4-methacryloyloxyphenyl) propyl-trimethoxysilane(p-MPS), -triisocyanatesilane (p-MBI), -trichlorosilane (p-MBC) were synthesized. The bonding durability of these silanes against water immersion and thermal stress was investigated. 3-methacryloyloxypropyltrimethoxysilane (3-MPG) was used as a control. The glass modified with those silanes at a concentration of 2wt% were kept for 3 minutes at $120^{\circ}C$, and then were bonded to the heaped metal with self-cured resin composite.(omitted)

  • PDF

Plasticization in Unclustered Poly(methyl methacrylate) Ionomers

  • 김준섭;김희석;Adi Eisenberg
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.6
    • /
    • pp.625-628
    • /
    • 1998
  • The dynamic mechanical properties of the unclustered cesium neutralized poly(methyl methacrylate-co-methacrylic acid) ionomers plasticized with three different plasticizers of low molecular weight were investigated. It was found that the effectiveness of the plasticization followed the order: glycerol (Gly) 4-decylaniline (4DA) >dioctyl phthalate (DOP). For the ionomer plasticized with Gly, the only effect was a significant decrease in the Tg. Thus it is concluded that the polar plasticizer not only increases the mobility of the ionomer but also dissolves the ionic groups. In the case of the 4DA-plasticized ionomer, both a drastic decrease in the Tg and the appearance of a second glass transition were observed. Therefore, it is suggested that the nonpolar 4DA molecules partition evenly in the poly(methyl methacrylate) matrix and cluster phases via hydrogen bonding between the aniline group of the plasticizer and the carbonyl groups of the ionomer. As a result, the Tg is lowered, multiplets can form, and the material behaves like a clustered ionomer.

Experimental analysis of damage in short-fiber-reinforced composite waste polyethylene terephthalate as a pile foundation material

  • Jang, Hongseok;Seo, Segwan;Cho, Daesung
    • Steel and Composite Structures
    • /
    • v.45 no.1
    • /
    • pp.147-157
    • /
    • 2022
  • This study assessed the compressive and tensile strengths and modulus of elasticity of waste polyethylene terephthalate (PET) using the ASTM standard tests. In addition, short carbon and glass fibers were mixed with waste PET to examine the improvements in ductility and strength during compression. The bonding was examined via field-emission scanning electron microscopy. The strength degradation of the waste PET tested under UV was 40-50%. However, it had a compressive strength of 32.37 MPa (equivalent to that of concrete), tensile strength of 31.83 MPa (approximately ten times that of concrete), and a unit weight of 12-13 kN/m3 (approximately half that of concrete). A finite element analysis showed that, compared with concrete, a waste PET pile foundation can support approximately 1.3 times greater loads. Mixing reinforcing fibers with waste PET further mitigated this, thereby extending ductility. Waste PET holds excellent potential for use in foundation piles, especially while mitigating brittleness using short reinforcing fibers and avoiding UV degradation.

A STUDY ON THE HUMAN PULPAL RESPONSE TO DENTIN BONDING DESENSITIZER (상아질 접착 지각과민 처치제에 대한 치수반응에 관한 연구)

  • You, Hee-Seung;Lee, Sung-Bok;Woo, Yi-Hyung;Park, Nam-Soo;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.483-495
    • /
    • 1998
  • The purpose of this study was to evaluate the human pulpal response to Dentin Bonding Desensitizer. Class V cavities were prepared on the buccal surfaces of the first premolars and Dentin Bonding Desensitizer(ALL-BOND Desensitizer, Bisco, Inc. U.S.A.) was applicated in ten experimental teeth, or ZOE(PROPAC, GC Co. TOKYO, JAPAN) cement in eight control teeth and cavities were filled with light curing glass ionomer(Fuji II LC, GC Co., TOKYO, JAPAN). At 3-day and 25-day postoperative interval. pulpal response was observed and evaluated histologically with light microscope. The results were as follows. ; 1. At 3-day postoperative interval, the control teeth were grade 1 inflammatory cell response and grade 1 connective tissue response. 2. At 25-day postoperative interval, all control teeth were grade 1 inflammatory cell response and in three control teeth grade 1 connective tissue response were observed, and one teeth showed grade 2 connective tissue response. 3. At 3-day postoperative interval, the experimental teeth were grade 1 inflammatory cell response and grade 1 connective tissue response. Below the cavity, a few inflammatory cell(PMNs) in odontoblastic layer, increased blood vessels and pulpal cells were seen and this pulpal response was similar to control teeth. 4. At 25-day postoperative interval, in four experimental teeth grade 1 inflammatory cell response and grade 1 connective tissue response were observed, and one experimental teeth showed mild inflammatory response. 5. At 3-day and 25-day postoperative interval, no reparative dentin deposition was seen. 6. Both experimental and control group, pulpal response showed difference between 3 and 25-day of postoperative interval. In control teeth, increased predentin and pulpal cells were seen and in experimental teeth, congestion of blood vessels and increased pulpal cells were seen. In conclusion, the pulpal irritation due to this Dentin Bonding Desensitizer was not severe, and it was considered that the agent was not harmful to the human pulp.

  • PDF

Low Temperature Hermetic Packaging by Localized Heating using Forced Potential Scheme Micro Heater (Forced Potential Scheme 미세 가열기를 이용한 부분 가열 저온 Hermetic 패키징)

  • 심영대;신규호;좌성훈;김용준
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.2
    • /
    • pp.1-5
    • /
    • 2003
  • In this project, the efficiency of localized heating for micro systems packaging is developed by using a forced potential scheme microheater. Less than 0.2 Mpa contact pressure was used for bonding with a 200 mA current input for $50{\mu}m$ width, $2{\mu}m$ height and $8mm{\times}8mm$, $5mm{\times}5mm$, $3mm{\times}3mm$ sized phosphorus-doped poly-silicon microheater. The temperature can be raised at the bonding region to $800^{\circ}C$, and it was enough to achieve a strong and reliable bonding in 3 minutes. The IR camera test results show improved uniformity in heat distribution compared with conventional microheaters. For performing the gross leak check, IPA (Isopropanol Alcohol) was used. Since IPA has better wetability than water, it can easily penetrate small openings, and is more suitable for conducting a gross leak check. The pass ratio of bonded dies was 67%, for conventional localized heating, and 85% for our newly developed FP scheme. The bonding strength was more than 25Mpa for FP scheme packaging, which shows that FP scheme can be a good candidate for micro-scale hermetic packaging.

  • PDF