• Title/Summary/Keyword: bond performance

Search Result 696, Processing Time 0.031 seconds

A Study on the Methodology to Performance Security on the Korea Small/Medium Sized Construction Firms for Venturing into International Market (국내 중소건설업체의 해외 진출 활성화를 위한 건설 보증 확대 방안에 관한 연구)

  • Ahn, Hyoung-Jun;Kim, Ju-Hyung;Kim, Jae-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.225-229
    • /
    • 2009
  • International construction market has been open to other countries, and it derives the development of our overseas construction industry quantitatively as well as qualitatively. Until now, the major companies have an absolute majority in the overseas construction market, and the small and medium enterprises have had difficulty to get a leadership in the international construction market because of the lack of the technical expertise and the capital strength. Especially in the Middle East Asia, our construction companies has touched off a boom, so our market share also has grown, which derived from the up toward ratchet oil prices and a worldwide boom in real estate development. The small and medium enterprise minority have recognition that the overseas construction market is the major company's native territory. But Data from the existing researches and many statistics indicate the most companies tend to underestimate the capacity and international competitiveness of the small and medium enterprises. As a matter of fact, hundreds of small and medium enterprise cut a conspicuous figure in overseas market. Consequently, it is indispensable to overcome the international financial crisis by revitalizing our overseas construction industry which obtains excellent results in international market. this study suggested the ways to expand overseas bonding capacity of Korean financial institution. This study proposed the Korean government to allow Construction Guarantee (former Korea Construction Financial Cooperative) to deal with foreign exchange so that Construction Guarantee will underwrite the overseas construction bond.

  • PDF

Compressive resistance behavior of UHPFRC encased steel composite stub column

  • Huang, Zhenyu;Huang, Xinxiong;Li, Weiwen;Zhang, Jiasheng
    • Steel and Composite Structures
    • /
    • v.37 no.2
    • /
    • pp.211-227
    • /
    • 2020
  • To explore the feasibility of eliminating the longitudinal rebars and stirrups by using ultra-high-performance fiber reinforcement concrete (UHPFRC) in concrete encased steel composite stub column, compressive behavior of UHPFRC encased steel stub column has been experimentally investigated. Effect of concrete types (normal strength concrete, high strength concrete and UHPFRC), fiber fractions, and transverse reinforcement ratio on failure mode, ductility behavior and axial compressive resistance of composite columns have been quantified through axial compression tests. The experimental results show that concrete encased composite columns with NSC and HSC exhibit concrete crushing and spalling failure, respectively, while composite columns using UHPFRC exhibit concrete spitting and no concrete spalling is observed after failure. The incorporation of steel fiber as micro reinforcement significantly improves the concrete toughness, restrains the crack propagation and thus avoids the concrete spalling. No evidence of local buckling of rebars or yielding of stirrups has been detected in composite columns using UHPFRC. Steel fibers improve the bond strength between the concrete and, rebars and core shaped steel which contribute to the improvement of confining pressure on concrete. Three prediction models in Eurocode 4, AISC 360 and JGJ 138 and a proposed toughness index (T.I.) are employed to evaluate the compressive resistance and post peak ductility of the composite columns. It is found that all these three models predict close the compressive resistance of UHPFRC encased composite columns with/without the transverse reinforcement. UHPFRC encased composite columns can achieve a comparable level of ductility with the reinforced concrete (RC) columns using normal strength concrete. In terms of compressive resistance behavior, the feasibility of UHPFRC encased steel composite stub columns with lesser longitudinal reinforcement and stirrups has been verified in this study.

Titanized or Zirconized Porous Silica Modified with a Cellulose Derivative as New Chiral Stationary Phases

  • Seo, You-Jin;Kang, Gyoung-Won;Park, Seong-Tae;Moon, Myeong-Hee;Park, Jung-Hag;Cheong, Won-Jo
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.6
    • /
    • pp.999-1004
    • /
    • 2007
  • Spherical porous silica supports modified with titanium or zirconium alkoxides were prepared, and allyl groups were chemically attached to the titanized or zirconized silica supports, and the product was cross-polymerized with a double bond containing cellulose derivative to yield new CSPs (chiral stationary phases). Magic angle spinning 13C solid state NMR and elemental analysis were used to characterize the CSPs. The performances of the chiral stationary phases were examined in comparison with a conventional chiral stationary phase. Spherical porous silica particles modified with 3,5-dimethylphenylcarbamate of cellulose were prepared and used as the conventional chiral stationary phase. Chromatographic data were collected for a few pairs of enantionmers in heptane/2-propanol mixed solvents of various compositions with the three chiral columns and the results were comparatively studied. The separation performance of the chrial phase made of the titanized silica was better than the others, and the separation performance of the chiral phase of the zirconized silica was comparable to that of the conventional chiral phase. The superiority of titanized silica over bare or zirconized silica in chiral separation seemed to be owing to the better yield of crosslinking (monitored by increase of carbon load) for titanized silica than for the others.

An Experimental Study on the Physical Properties of Concrete Spread with Liquefied Organic and Inorganic Complex Antibiotics (액상 유·무기 복합 항균제를 도포한 콘크리트의 물리적 특성에 관한 실험적 연구)

  • Kim, Mu-Han;Kim, Jae-Hwan;Jo, Bong-Suk;Lee, Eui-Bae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.67-75
    • /
    • 2006
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. In this study, to prevent biochemical corrosion of the sewer concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed and antimicrobial performance of it was investigated. After that, to consider applicability of antibiotics to concrete, physical properties of concrete spread with antibiotics were investigated. As a results of the study, it was proved that the antimicrobial performance of antibiotics was available. Also compressive strength and bond strength of concrete didn't closely connected with antibiotics, and resistance to abrasion, water absorption and air permeability of concrete was improved remarkably by spraying with it.

Performance of Wood-plastic Panel Made from Populus alba × glandulosa and Low Density Polyethylene (은수원사시나무와 저밀도 폴리에틸렌으로 제조된 목질플라스틱패널의 성능)

  • Kwak, Jun-Hyuk;Oh, Yong-Sung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.67-72
    • /
    • 2004
  • Wood/polyethylene panels were manufactured from Populus alba × glandulosa particles and low density polyethylene particles at three mixing rates, 50:50, 60:40, and 70:30. A total of 15 wood/polyethylene panels was made at 145℃ and 5 minutes hot-press time. Wood/polyethylene panels were tested for internal bond, bending, and dimensional stabilities such as thickness swell and water absorption. Panel performance data were analyzed using the SAS programing package. The test results of the wood/polyethylene panels showed that as the polyethylene mixing rates were increased, the panel property values increased. Based on panels' dimensional stabilities, the optimum wood/polyethylene mixing ratio appeared to be 60:40.

Experimental Study on Bond Behavior of 1/12.5 Scale Model of the Steel Tubular Joint Connection Subjected to Compressive Loads (압축하중을 받는 1/12.5 축소모형 강관 연결부의 부착전단 거동에 대한 실험적 연구)

  • Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.19-26
    • /
    • 2024
  • In this study, the compressive behavior of a 1/12.5 scale model of a wind tower support structure connection was experimentally analyzed. A high-performance cementitious grout with a compressive strength of 140 MPa was used to fill the connection, and experiments were conducted with shear key spacing, the shape, and connection length as variables. When the number of shear keys in the connection is the same, the smaller the spacing of the shear keys than the length of the connection, the higher the shear strength, and for the same spacing and connection length, the higher the height of the shear keys, the higher the strength. In addition, it was found that the strength showed a linear behaviour until the connection slip reached 1.0 mm, and it reached the maximum strength at 7.0 mm connection slip showing a non-linear behaviour as the load increased. It was found that the failure mode changed from interfacial shear failure to grout failure as the strength increased according to the shape and spacing of the shear key, and brittle failure did not occur due to steel fibers.

Structure/Property of Adhesives and Adhesion Performance (접착제의 구조물성과 접착특성)

  • Hiroshi Mizumachi
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.29 no.1
    • /
    • pp.73-83
    • /
    • 1997
  • Most of the materials used in various industrial fields and also in our daily life are multi-component materials or composite materials, and it is well known that there are many cases where adhesion between the constituents within the bonded systems plays an important role. There are various types of performance evaluation tests for the bonded materials, among which tests for evaluating the bond performance under various conditions may be regarded as the most interesting ones for those engaged in work related to adhesion. I have studied on the mechanism of adhesion form the rheological standpoint with my colleagues, including some students from Korea, and I am very happy to be able to have a talk on some of our research works. In Japan, the so-called "adhesives" are usually classified into two categories;adhesives and pressure sensitive adhesives (PSA). Adhesives are the materials which solidify after bonding and are after used as the structural adhesives because the adhesive strength is comparatively strong. On the other hand, the pressure sensitive adhesives never solidify and are used as PSA tapes, labels or decals. About the adhesives, we have examined the dependence of adhesive strength(shear, tensile, peel) upon both temperature and rate of deformation, and found out some empirical rules which are applicable to most of the adhesive systems. We have also developed a simplified theory of adhesion, which is deseribed in terms of mechanical equivalent mode1 and a few failure criteria. Although some of the common rules can be accounted for according to this theory, it must be pointed out that a fracture mechanical approach ms inevitable especially in the region where the meehanical relaxation time of the adhesive is extremely large [W. W. Lim and H. Mizumachi]. About the pressure sensitive adhesives, we have studied on the PSA performance (peel, tack, holding power) as a function of both the viscoelastic properties and surface chemical properties of the materials, and found out some rules, and again we have developed a theory which deseribes the mechanism. And in addition, we have studied on the miscibility between linear polymers and oligomers, because PSA is generally manufactured by blending gums and tackifier resins. Many phase diagrams have been found and some of them have been analyzed on thermodynamic basis, and it became evident that the miscibility is a very important factor in PSA [H. J. Kin and H. Mizumachi]. In this presentation, I want to emphasize the fact that the adhesion performance is closely related to the structure/property of the adhesives.adhesives.

  • PDF

Experimental Studies on Bond and Splice Performance of Splice Sleeve for Connecting Rebar (철근연결용 스플라이스 슬리브의 이음 및 부착성능에 대한 실험적 연구)

  • Kang, Duk Man;Park, Yong Gul;Lee, Hyeon Gi;Moon, Do Young
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.257-264
    • /
    • 2017
  • The PC (Precast Concrete) construction method is a technique where concrete members that have been produced in a plant are constructed on site. Thus, continuity and secure integration of a structure that can be obtained by connecting rebars at splicing joint for PC members are the main areas of concern for this method. To evaluate the splicing and bonding performance according to application of a splice sleeve for connecting rebar in this research study, the diameter of rebar, development length, grouting strength etc. were set as variables. The performance and stiffness of splicing according to the development length of grout strength were measured and evaluated. In addition, by conducting comparative analysis on each of the variables, the factors that affected the splice sleeve for connecting rebar were discussed. The results confirmed that the strength and stiffness of the splice sleeve for connecting rebar were significantly affected by the development length while the increase in performance according to grout strength was not as significant.

Effects of Fiber Blending Condition and Expansive Admixture Replacement on Tensile Performance of Rebar Lap Splice in Strain-Hardening Cement-Based Composites (SHCCs) (섬유혼입조건 및 팽창재 대체에 따른 변형 경화형 시멘트 복합체 내의 철근 겹침이음 성능)

  • Ryu, Seung-Hyun;Lee, Young-Oh;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.111-120
    • /
    • 2012
  • This paper is a report about lap splice performance of rebar embedded in the strain-hardening cement-based composites (SHCCs) under monotonic and repeated tension loading. Ten mix proportions of cement-based composites such as SHCCs and normal concrete were investigated. The study parameters are comprised of (1) types of reinforcing fibers (polyethylene and steel fiber), (2) replacement levels of expansive admixture (EXA, 0% and 10%), and (3) compressive strength (30 and 100 MPa) of cement-based composites. Lap splice lengths (ld) of rebars in SHCC materials and normal concrete were 60% and 100% of splice length calculated by code requirements for structural concrete, respectively. Test results indicated that SHCCs materials can lead to enhancements in the lap splice performance of embedded rebar. All of the fiber reinforcement conditions (PE-SHCC and PESF-SHCC) considered in this study produced considerable improvements in the tensile strength, cracking behavior, and bond strength of lap-spliced rebar. Furthermore, adding EXA to SHCC matrix improved the tensile lap splice performance of rebar in SHCC materials. However, for controlling crack behavior, the performance of PE-SHCC was better than that of PESF-SHCC due to its mechanical properties. This study demonstrated an effective approach for reducing required development length of lap spliced rebar by using SHCC materials.

An Experimental Study and Value Analysis for Performance Assessment of the Embo-thane Membrane Waterproofing Method (엘보탄도막방수공법의 성능평가를 위한실험적 연구 및 VE분석)

  • Yoon, Cha-Woong;Lee, Seung-Soo;Kim, Sang-Rok;Seo, Jong-Won
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.5
    • /
    • pp.123-134
    • /
    • 2009
  • Since 1970s, urethane waterproofing method is broadly used in rooftops, underground spaces, and sports stadium for its outstanding ultraviolet blockage, watertightness, and elasticity. However, development of slippage-resistance and endurance, improvement of function considering convenience and visually pleasing of users, urethane waterproofing method is necessary, since rooftops and underground spaces have slippage and external force risks. Therefore, many improved waterproofing methods are being developed and, recently, embo-thane waterproofing method, which applies embo-spray coating system, has been developed. This paper explains exposure, nonexposure, and floor-material of embo-thane waterproofing method, and then perform experimental study for comparison with urethane waterproofing method about tensile strength, coefficient of expansion, performance of bond, anti-abrasion, and slippage-resistance. In addition, the performance index was presented for the superiority of embo-thane waterproofing method compared to urethane by setting up evaluation criteria considering not only physical performance but also design side of embo-thane waterproofing method, and Value Analysis applying AHP. Also for an assessment considering uncertain result, Monte Carlo Simulation Method was used to operate reliability analysis through statistic approach method.