• 제목/요약/키워드: bolt spacing

검색결과 29건 처리시간 0.026초

보수.보강된 철근 콘크리트보의 구조적 거동에 관한 연구 (Structural Behavior of Strengthened RC Beams)

  • 오병환;조재열;강동옥
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.501-507
    • /
    • 1996
  • The final objectives of this study are to present the theoretical formula for reasonable structural analysis and practical codes on the repair/strengthening of damaged reinforced concrete structrues. For that purpose, in last year, preliminary experiments for flexure and shear of beam structure using carbon sheet and steel plate were performed, and in sequence, in this year, using aramid fiber sheet and steel plate more extensive experiment were performed. Repair for the performance of flexure and shear was focused on, and main variables were selected considering aplicablilty for practical field, such as, spacing of anchor bolt, lapping, jacking up, preloading level, and fiber difection as well as length of repairing plate and thickness. so new results from various angles are to be presented.

  • PDF

강판 휨보강된 철근 콘크리트보의 구조적 거동 (Structural Behavior of RC Beam Strengthened with Steel Plate)

  • 오병환;강동욱;조재열;채성태;이명규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.598-604
    • /
    • 1997
  • In recent years, strengthening by epoxy-bonded steel plates, carbon fiber sheets, aramid fiber sheets and so on, is spotlighted. Among them, the method using steel plates is most widely applied. Most studies have dealt with strengthening by epoxy-bonded steel plates. However the actual behavior of strengthened RC beams are not well established. Particularly, the studies on the separation load thar affects failure load of the beam are relatively insufficient. In this study, test parameters are the magnitude of pre-load, plate length, plate thickness, existence and spacing of anchor bolt, the number of plate layer and the height of side strengthening, 17reinforced concrete beams are strengthened by steel plates according to test parameters. Deflection, failure load, strains of reinforcing bar, concrete and plate are measured from tests(4 points loading). The failure mode, and separation load are analyzed from these measured data. The difference between Robert's theory and test results is discussed, and the prediction equation for separation load in the case of rip off is proposed.

  • PDF

수직 행거 내진설계용 스티프너의 단조 압축 실험 (Monotonic Loading Tests on Seismic Stiffeners for Vertical Hangers)

  • 오창수;공하성
    • 대한안전경영과학회지
    • /
    • 제25권2호
    • /
    • pp.187-192
    • /
    • 2023
  • In piping systems, trapeze hangers are subjected to vertical and horizontal seismic loads and stiffeners are used. In this study, monotonic compression tests were conducted with the removable stiffeners using three variables: stiffener clamp fixing position, section length, and installation direction. The maximum load reinforced with stiffeners could withstand a compressive load of 11kN by applying a safety factor of 10%. It could be estimated that the fixing clamp spacing or the length of shape and load had a proportional relationship. And the stiffener must be fixed in the direction of the strong axis on hinge parts. Also the stiffener buckiling load design proposes to use a method of calculate the flexural buckling compressive strength of and unreinforced full threaded bolt.

정하중 재하 시 실물 강성벽 일체형 철도보강노반의 성능평가 (Performance Evaluation of Full Scale Reinforced Subgrade for Railroad with Rigid Wall Under Static Load)

  • 김대상
    • 한국지반신소재학회논문집
    • /
    • 제14권3호
    • /
    • pp.31-42
    • /
    • 2015
  • 강성벽 일체형 철도보강노반의 열차하중 하에서의 성능을 평가하기 위하여 실물 단선 철도 노반과 동일한 규모인 높이*폭*길이(5m*6m*20m)의 보강노반을 건설하였다. 철도보강노반은 높이의 30~40%의 짧은 보강재와 강성벽체, 보강재 연직배치간격 30와 40cm를 적용한 특징이 있다. 경제성 및 시공성 향상을 위하여 강성벽체와 보강토체와의 일체화 연결방식을 3종류(용접형, 힌지볼트형, 굵은 철사형)로 다르게 설계하였다. 철도 설계하중 50kPa의 19.6배에 해당되는 0.98MPa (최대시험하중 5.88MN) 최대하중에 대하여 2회 정하중 재하시험을 실시하였다. 철도보강노반의 성능은 파괴에 대한 안정성, 지지력과 침하, 벽체 발생 수평변위, 보강재 발생 변형률에 대한 검토로부터 평가하였다. 실물 실대형 시험결과로부터 높이의 35% 수준의 짧은 보강재와 힌지 볼트형 연결방식을 채택한 강성벽체 일체형 철도보강노반에서 40cm의 보강재 연직간격을 적용하여도 열차 설계하중 하에서 좋은 성능을 보이는 것을 확인할 수 있었다.

부착식 후설치 앵커로 연결된 내민보의 구조 안전성에 대한 실험적 평가 (Experimental Verification on the Structural Safety of Cantilever Beam Connected with Post-installed Adhesive Anchor Bolts)

  • 오홍섭;박성락
    • 콘크리트학회논문집
    • /
    • 제23권4호
    • /
    • pp.529-536
    • /
    • 2011
  • 최근 들어 국내의 교량 확장 보도부에 대한 관심이 고조되고 있다. 교량 확장 보도부에 적용되는 내민보는 부착식 앵커 볼트를 이용한 구조를 사용하고 있다. 그러나 현재 적용되고 있는 내민보의 경우 정확한 기준이 없는 상태로 설치 간격 및 단면 등이 과다 설계되고 있으며 과다한 중량에 의한 시공상의 문제점들도 발생하고 있다. 또한 연결되는 부착식 후설치 앵커 볼트에 관한 실험 및 해석 결과 등이 충분치 않기 때문에 불필요한 앵커 볼트의 수량을 증대시키고 있다. 이에 이 논문에서는 앵커 연결된 내민보의 구조 거동 평가 실험을 통해 기존의 내민보의 단면을 최적화하여 단면의 효율성을 확보하고, 불필요한 앵커 볼트의 수량을 줄일 수 있는 기법을 제안하고자 하였다. 실험 결과 내민보의 파괴는 부착식 앵커의 부착 파괴에 지배되는 것으로 나타났으며, 압축 측의 앵커 개수를 감소시켜도 부재의 안전성에는 크게 문제가 없는 것으로 관찰되었다. 또한 내민보의 형상을 변화시키고 프리스트레싱을 도입함으로서 사용 상태의 사용성도 향상시킬 수 있는 것으로 나타났다.

Investigating the supporting effect of rock bolts in varying anchoring methods in a tunnel

  • Wang, Hongtao;Li, Shucai;Wang, Qi;Wang, Dechao;Li, Weiteng;Liu, Ping;Li, Xiaojing;Chen, Yunjuan
    • Geomechanics and Engineering
    • /
    • 제19권6호
    • /
    • pp.485-498
    • /
    • 2019
  • Pre-tensioned rock bolts can be classified into fully anchored, lengthening anchored and point anchored bolts based on the bond length of the resin or cement mortar inside the borehole. Bolts in varying anchoring methods may significantly affect the supporting effect of surrounding rock around a tunnel. However, thus far, the theoretical basis of selecting a proper anchoring method has not been thoroughly investigated. Based on this problem, 16 schemes were designed while incorporating the effects of anchoring length, pretension, bolt length, and spacing, and a systematic numerical experiment was performed in this paper. The distribution characteristics of the stress field in the surrounding rock, which corresponded to various anchoring scenarios, were obtained. Furthermore, an analytical approach for computing the active and passive strengthening index of the anchored surrounding rock is presented. A new fully anchoring method with pretension and matching technology are also provided. Then, an isolated loading model of the anchored surrounding rock was constructed. The physical simulation test for the bearing capacity of the model was performed with three schemes. Finally, the strengthening mechanism of varying anchoring methods was validated. The research findings in this paper may provide theoretical guidelines for the design and construction of bolting support in tunnels.

볼트접합 앵글을 사용한 PSRC 합성기둥의 편심 압축실험 (Eccentric Axial Load Test of Prefabricated Composite Columns Using Bolt-connected Steel Angles)

  • 김현진;황현종;박홍근;김동관;양종민
    • 한국강구조학회 논문집
    • /
    • 제29권3호
    • /
    • pp.249-260
    • /
    • 2017
  • 볼트접합 앵글을 사용한 선조립-SRC 합성기둥(이하 PSRC 합성기둥)의 구조성능을 평가하기 위하여 PSRC 기둥실험체 6개와 일반 SRC 기둥실험체 2개에 대하여 편심축 압축실험을 수행하였다. 횡보강재의 수직간격 및 단면형상과 축하중의 편심율을 실험변수로 고려하였다. 실험결과, 편심율이 큰 경우 PSRC 실험체는 단면 코너에 위치한 고강성 앵글로 인하여 압축하중 재하능력 및 변형능력이 기존 SRC 실험체보다 향상되었다. PSRC 기둥 실험체에서 횡방향 강판의 좁은 횡보강 간격과 Z형 단면의 횡방향 강판은 우수한 횡구속력을 제공하였으며, 하중재 하능력을 향상시켰다. 실험 및 수치해석을 통한 합성기둥의 휨 압축 강도는 현행설계기준에 의한 휨-압축 상관도를 상회하였다. 수치해석결과는 각 실험체의 강성, 최대강도, 최대하중 이후 강도감소거동을 비교적 잘 예측하였다.

볼트접합 앵글을 사용한 합성기둥의 중심축 압축실험 (Axial Load Test of Prefabricated Composite Columns Using Bolt-connected Steel Angles)

  • 김현진;황현종;박홍근;김동관;양종민
    • 한국강구조학회 논문집
    • /
    • 제29권2호
    • /
    • pp.147-158
    • /
    • 2017
  • 본 연구에서는 볼트조립 앵글을 적용한 선조립 합성기둥(이하 PSRC 합성기둥)의 압축성능을 연구하였다. 2/3 축소비율의 PSRC 기둥실험체 4개와 기존 SRC 기둥실험체 2개에 대하여 중심축 압축실험을 수행하였다. 횡보강재의 수직간격 및 단면형상과 앵글의 단면형상을 실험변수로 고려하였다. 실험결과, PSRC 기둥실험체는 기존 SRC 기둥실험체와 비교하여 비슷한 압축하중 재하능력 및 변형능력을 발휘하였다. PSRC 합성기둥의 경우, 횡방향 강판의 좁은 횡보강 간격과 Z형 단면의 강판이 압축강도 및 변형능력 향상에 효과적인 것으로 나타났다. 또한 PSRC 합성기둥은 현행설계기준에 의한 공칭 압축강도보다 큰 압축하중 재하능력을 나타내었다. 실험체들에 대한 수치해석결과는 피복 콘크리트 탈락으로 인한 하중감소를 제외하고 초기강성 및 하중재하능력을 비교적 잘 예측하였다.

철근 콘크리트 보의 보강을 위한 하이브리드 조립형 보강기법에 관한 해석적 연구 (Analytical Study on Hybrid Prefabricated Retrofit Method for Reinforced Concrete Beams)

  • 문상필;이성호;이영학;김민숙
    • 한국공간구조학회논문집
    • /
    • 제20권3호
    • /
    • pp.71-79
    • /
    • 2020
  • In this paper, the hybrid prefabricated retrofit method that improve structural performance and reduce construction period was developed by using a finite element analysis. The hybrid prefabricated retrofit method consist of a Z-shaped side plate, a L-shaped lower plate, and a bottom plate containing an steel plate with openings. This shape has advantage that a retrofit method is possible regardless of the size of the beams and a follow-up process such as reinforcement bars placing are not required. The finite element analysis of hybrid Prefabricated retrofit method showed the most ideal stress distribution when the thickness of bottom plate was 10mm, the thickness of the L-shaped lower plate was 5mm, the thickness of the Z-shaped side plate was 2.5mm, and the bolt spacing was 200mm. The bending strength equation of Hybrid prefabricated retrofit method was proposed through the plastic stress distribution method in KDS 41 31 00. The result of Comparison the proposed equation with the finite element analysis, it is determined that the design of hybrid prefabricated retrofit method is possible through the KDS 41 31 00.

Comparison of structural foam sheathing and oriented strand board panels of shear walls under lateral load

  • Shadravan, Shideh;Ramseyer, Chris C.;Floyd, Royce W.
    • Advances in Computational Design
    • /
    • 제4권3호
    • /
    • pp.251-272
    • /
    • 2019
  • This study performed lateral load testing on seventeen wood wall frames in two sections. Section one included eight tests studying structural foam sheathing of shear walls subjected to monotonic loads following the ASTM E564 test method. In this section, the wood frame was sheathed with four different types of structural foam sheathing on one side and gypsum wallboard (GWB) on the opposite side of the wall frame, with Simpson HDQ8 hold down anchors at the terminal studs. Section two included nine tests studying wall constructed with oriented strand board (OSB) only on one side of the wall frame subjected to gradually applied monotonic loads. Three of the OSB walls were tied to the baseplate with Simpson LSTA 9 tie on each stud. From the test results for Section one; the monotonic tests showed an 11 to 27 percent reduction in capacity from the published design values and for Section two; doubling baseplates, reducing anchor bolt spacing, using bearing plate washers and LSTA 9 ties effectively improved the OSB wall capacity. In comparison of sections one and two, it is expected the walls with structural foam sheathing without hold downs and GWB have a lower wall capacity as hold down and GWB improved the capacity.