Browse > Article
http://dx.doi.org/10.4334/JKCI.2011.23.4.529

Experimental Verification on the Structural Safety of Cantilever Beam Connected with Post-installed Adhesive Anchor Bolts  

Oh, Hong-Seob (Dept. of Civil Engineering, Gyeongnam National University of Science and Technology)
Park, Sung-Rak (Dept. of Civil Engineering, Gyeongnam National University of Science and Technology)
Publication Information
Journal of the Korea Concrete Institute / v.23, no.4, 2011 , pp. 529-536 More about this Journal
Abstract
Recently, there has been a growing interest in expanded sidewalks for existing bridges. The cantilever beam system applied to expanded sidewalks for existing bridges are connected with the concrete structure by adhesive anchor bolts. However, the extended sidewalks are currently constructed without standardized regulations, which lead to excessive design of the beam spacing and installation and the construction difficulties due to the excessive over-weight. Moreover, there is only limited analysis and experiment data on the post-installed adhesive anchor bolts, so the excessive number of bolts is used for the connection. This paper deals with a method to increase the effectiveness of beam sections and anchor bolts geometry for expanded sidewalk of existing bridge. The study results showed that the failure of cantilever beam connected by adhesive anchor bolts was dominated by bond failure of interface between concrete and bolt. Also, the results indicated the possibilities of improving serviceability as well as safety of the sidewalks by changing of beam section and prestressing the bolts.
Keywords
cantilever beam; post installed adhesive anchor bolt; prestressing; expanded sidewalk;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Eligehausen, R., Mallee, R., and Silva, F. J., Anchorage in Concrete Construction, Ernst & Sohn, 2006, 378 pp.
2 유성원, 정상화, 곽기석, 이주형, "부착식 앵커의 인발 특성에 관한 실험적 연구," 대한토목학회 논문집, 26권, 3호, 2006, pp. 555-563.   과학기술학회마을
3 김익현, 이득원, 이성재, 최동욱, "콘크리트앵커설계법과 국내 실험 데이터 비교," 콘크리트학회지, 17권, 5호, 2005, pp. 29-38.
4 Matthew Miltenberger, P. E., Capacity Design of Grouted Anchors, SMiRT 16, Wasington DC, 2001, pp. 1790-1797.
5 ASTM E488, Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements, ASTM, 1996, 21 pp.
6 건설교통부, 도로교 설계 기준, 2005, 510 pp.
7 국토해양부, 자전거도로 시설기준 및 관리지침, 2009, 196 pp.
8 고원준, 김길희, 김승훈, 김세훈, 김익현, 이남호, 이대용, 이득원, 이왕희, 최동욱, 하상수, 콘크리트용 앵커 설계법 및 예제집, 한국콘크리트학회, 2010, 338 pp.
9 ACI Committee 318, Building Code Requirements for Structural Concrete and Commentary (ACI318M-05), American Concrete Institute, 2005, 443 pp.
10 김익현, 김길희, 천성철, 이성재, 이왕희, 최완철, "앵커의 설계기준 (ACI318-05)," 한국콘크리트학회 학술대회논문집 2006, pp. 53-63.
11 Lehr, R., "Tragverhalten von Verbunddübeln im Ungerissenen unter Zentrischer Belastung im Ungerissenen Beton-Gruppenbefestigungen und Befestigungen am Bauteilrand," Doctoral Thesis, University of Stuttgart, Stuttgart, Germany, 2003, 320 pp.
12 Cook, R. A., Kunz, J., Funchs, W., and Konz, R. C., "Behavior and Design of Single Adhesive Anchors under Tensile Load in Uncracked Concrete," ACI Structural Journal, Vol. 95, No. 1, 1998, pp. 9-26.
13 Eligehausen R., Cook R., and Appl, J., "Behavior and Design of Adhesive Bonded Anchors," ACI Structural Journal, Vol. 103, No. 6, 2006, pp. 822-831.