• Title/Summary/Keyword: boiler safety

Search Result 94, Processing Time 0.028 seconds

Basic characteristic of non-sintered binder using by CFBC ash (순환유동층 보일러애시를 활용한 비소성 결합재 기초 특성)

  • Kang, Yong-Hak
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.225-226
    • /
    • 2017
  • Recently, there has been a growing interest in the development of non-sintered binder to reduce CO2 emissions from the cement clinker manufacturing process and a number of studies have been conducted on fly ashes as an industrial by-product. However, in order to utilize fly ashes as a non-sintered binder, it is necessary to solve problems such as safety issues and economical efficiency due to use of an alkali activator. This study evaluates the material properties and compressive strength characteristics of three types of circulating fluidized bed boiler ashes. As a result, it was confirmed that the characteristics of each binder vary depending on the location of the power plant and the types of raw materials. In addition, it has been confirmed that the fluidized bed boiler ash shows a high compressive strength and can be used sufficiently as an non-sintered binder.

  • PDF

Combustion Characteristics of Non-premixed VIStA Burner in Once-Through-Type Boiler (관류보일러 연소실에서 비예혼합 VIStA 버너의 연소 특성)

  • Ahn, Joon;Kim, Hyouck-Ju;Choi, Kyu-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.547-552
    • /
    • 2010
  • A modified VIStA (vortex inertial staged air) burner was developed and used in a once-through-type boiler. For safety, the combustion in this burner is of the non-premixed type. An air damper is installed to control the distribution of air to each combustion chamber. The effects of the air-fuel ratio and air distribution on NOx formation were investigated. The newly modified VIStA burner gives NOx reduction effect by maximum 20% in the combustion chamber of a boiler, while it yields more uniform flame than the conventional burner.

An Ontology-based Generation of Operating Procedures for Boiler Shutdown : Knowledge Representation and Application to Operator Training (온톨로지 기반의 보일러 셧다운 절차 생성 : 지식표현 및 훈련시나리오 활용)

  • Park, Myeongnam;Kim, Tae-Ok;Lee, Bongwoo;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.47-61
    • /
    • 2017
  • The preconditions of the usefulness of an operator safety training model in large plants are the versatility and accuracy of operational procedures, obtained by detailed analysis of the various types of risks associated with the operation, and the systematic representation of knowledge. In this study, we consider the artificial intelligence planning method for the generation of operation procedures; classify them into general actions, actions and technical terms of the operator; and take into account the sharing and reuse of knowledge, defining a knowledge expression ontology. In order to expand and extend the general operations of the operation, we apply a Hierarchical Task Network (HTN). Actual boiler plant case studies are classified according to operating conditions, states and operating objectives between the units, and general emergency shutdown procedures are created to confirm the applicability of the proposed method. These results based on systematic knowledge representation can be easily applied to general plant operation procedures and operator safety training scenarios and will be used for automatic generation of safety training scenarios.

A Study on Accident Cases of Gas Boiler Carbon monoxide (가스보일러 일산화탄소 중독사고에 대한 사례 연구)

  • Lee, J.W.;Yeo, C.H.;Park, C.O.;Park, C.I.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.10 no.1
    • /
    • pp.29-35
    • /
    • 2007
  • 가스보일러의 확대 보급으로 2006년도 932만대가 주택, 상가 및 산업현장 등에 보급되어 생활의 편리성이 높아지고 있으나 가스보일러의 설치불량, 관리소홀 및 제품의 노후 등으로 사고가 끊이지 않고 발생하고 있다. 가스보일러가 연소 중에 발생하는 배기가스가 실내에 유출되어 최근 5년간 30건의 사고로 사상자가 92명이 발생하는 등 1건의 사고로 3명이상의 높은 인명 피해를 나타냈다. 본 연구에서는 가스보일러의 사고통계분석과 2건의 사고사례를 분석한 결과 가스보일러의 제품의 안전성 향상과 실내에 배기가스가 누출되었을 때 신속히 검지할 수 있는 경보시스템의 방안이 필요할 것으로 보인다.

  • PDF

Evaluation on Performance of Hybrid Heating System with Solar Collector of Thermosyphon Tube Type (열사이폰관형 태양열집열기를 주열원으로 하는 하이브리드 난방시스템 성능 평가)

  • Chun, Tae-Kyu;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.356-361
    • /
    • 2012
  • Recently, even though the researches on renewable energy like geothermal, wind, solar energy have been performed widely, its use-rate in total energy is still low. This study was carried out to investigate the performance of hybrid heating system, which consisted of solar collector of thermosyphon tube type and X-L pipe boiler. Especially, new type of solar collector was tried and compared with double tube type and, futhermore, performance and safety on X-L pipe boiler were investigated. As the results, efficiency of solar collector of thermosyphon tube type was higher 20.7% than that of double tube type, mainly due to its structural characteristics. It was also confirmed that temperature of special heat medium used X-L pipe boiler rose up about 20% rapidly in comparison with that of pure water.

A Study on Wire-rope Type Furnace Scaffolding and Its Lifting System for Large-sized Boiler (대형 보일러 와이어로프 노내비계 및 인양시스템에 관한 연구)

  • HA, Seung Woo;Lee, Tae Ho;Lee, Hae Seung;Kim, Jeung Min;You, Tai Woo;Cho, Sun Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.7
    • /
    • pp.679-683
    • /
    • 2016
  • Boilers of large-sized coal-fired power plants are being operated under very poor conditions such as continuous operation or repeating of start-up and shutdown for a stable supply of electricity. Thus periodic inspection and maintenance are required to ensure reliability of operation. The loads of existing scaffolding systems for the maintenance of boilers are concentrated in the lower parts structurally, which may cause a serial collapse of the overall scaffolding system when there are problems in some members. Therefore, in this study, a safe furnace scaffolding system is developed by dispersing the loads in the upper part, as well as minimizing the hazards of serial collapsing. In addition, for cases where the direct installation of furnace scaffolding is challenging owing to the structure of the boiler tube, a lifting system for the installation of furnace scaffolding is developed so that furnace scaffolding can be supported to secure the integrity of the power generating facility.

Flaw Discrimination for Welding Points in Boiler Tubes by Phased Array Ultrasonic Testing (위상배열초음파탐상검사에 의한 보일러관 용접부의 결함 판별)

  • Cho, Kuk-Hyung;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.14 no.2
    • /
    • pp.45-50
    • /
    • 2018
  • Nuclear safety law's amendment caused many problems to use radiography testing(RT). Phased array ultrasonic testing(PAUT) was adapted instead of RT for NDE of welding points in boiler tubes these days. Unfortunately, PAUT doesn't give us the discrimination characteristics about flaws distinction and flaws size clearly. In this thesis, the distinction characteristics of flaw types and the detection characteristics of flaw size using PAUT of welding points in boiler tubes were analyzed. It was concluded that PAUT can distinguish between planar flaws and rounded flaws, but it is hard to tell apart the types of flaw respectively. We paid attention to the discrimination of flaws size because PAUT tends to underestimate the flaw size of porosity and underestimate or overestimate the flaw size of porosity.

  • PDF

The Development of Boiler Furnace Pressure Control Algorithm and Distributed Control System for Coal-Fired Power Plant (석탄화력발전소 보일러 노내압력 제어알고리즘과 분산제어시스템의 개발)

  • Lim, Gun-Pyo;Hur, Kwang-Bum;Park, Doo-Yong;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.117-126
    • /
    • 2013
  • This paper is written for the development and application of boiler furnace pressure control algorithm and distributed control system of coal-fired power plant by the steps of design, coding, simulation test, site installation and site commissioning test. The control algorithms were designed in the shape of cascade control for two parts of furnace pressure control and induced draft fan pitch blade by standard function blocks. This control algorithms were coded to the control programs of distributed control systems. The simulator for coal-fired power plant was used in the test step and automatic control, sequence control and emergency stop tests were performed successfully like the tests of the actual power plant. The reliability was obtained enough to be installed at the actual power plant and all of distributed control systems had been installed at power plant and all signals were connected mutually. Tests for reliability and safety of plant operation were completed successfully and power plant is being operated commercially. It is expected that the project result will contribute to the safe operation of domestic new and retrofit power plants, the self-reliance of coal-fired power plant control technique and overseas business for power plant.

Development of a Fault Diagnosis System for Circulating Fluidized Bed Boiler Tube (순환유동층 보일러 튜브 결함 진단을 위한 진단장치 개발)

  • Kim, Yu-Hyun;Jeong, In-Kyu;Ban, Jae-Kyo;Kim, JaeYoung;Kim, Jong-Myon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.07a
    • /
    • pp.53-54
    • /
    • 2018
  • 최근 화력 발전소 보일러 튜브의 노후화로 인해서 불시정지 빈도수 및 재가동 시간이 늦춰지고 있다. 이는 막대한 경제적, 사회적 손실로 이어지며, 이를 예방하기 위해서는 상태기반 정비가 필요하다. 현재의 상태기반 정비는 센서, 신호 수집장치, 신호 분석단계를 거쳐 전문가가 진단하기 때문에 즉각적으로 대응하기 어려운 문제점이 있어서 설비의 재가동 시간이 늦춰지고 있다. 따라서 본 논문에서는 전문가의 도움 없이 자동으로 상태를 진단하기 위해서 머신러닝 기법 중 하나인 서포트 벡터 머신(SVM)을 이용한 진단 알고리즘을 구현하고, 이를 탑재한 진단장치를 개발하여 비전문가들도 즉각적으로 대응할 수 있게 하여 불시정지 시간과 빈도수를 줄이고자 한다.