• 제목/요약/키워드: boiler building

검색결과 62건 처리시간 0.028초

건축물내 일산화탄소 경보기 설치에 관한 연구 (A Study on Installation of Carbon Monoxide Detector in a Building)

  • 강승규;최경석;오정석
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2008년도 춘계학술 발표회
    • /
    • pp.217-222
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

온돌 난방에 대한 동적 시뮬레이션 및 분석 (Method and Analysis of Dynamic Simulation for Ondol Heating)

  • 홍희기;김시환
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.375-382
    • /
    • 2010
  • Ondol heating, a kind of radiant floor heating, is a main method used in housing units in Korea. Building energy simulation including ondol and relevant facilities has not been performed due to its complexity. For evaluating energy consumption and indoor temperature variation, a new method should be proposed. At the present work, a dynamic simulation on ondol heating was tried by combining TRNSYS and EES. Characteristic functions for a pump, hot water coils and a gas boiler were simultaneously solved by EES, and calculated flow rates and supply temperature of hot water were provided as inputs of the active layer of TYPE 56 in TRNSYS. The results by the simulation on a typical housing unit in Korea shows a good trend in a viewpoint of actual behavior of ondol heating.

열병합시스템 경제성 평가 프로그램의 개발 및 적용에 관한 연구 (Development and Application of an Economic Assessment Program of Cogeneration Systems)

  • 박차식;김용찬
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1547-1554
    • /
    • 1998
  • The object of this study was to develop an economic assessment program for the optimal design of the cogeneration systems composed of combining engine, generator, waste heat recovery exchanger, absorption chiller, and boiler, etc. The energy demand categorized by electric power, heating, cooling and water supply was determined by statistical data of the existing cogeneration systems. An economic assessment was performed by comparing the total cost of cogeneration system with that of non-cogeneration system. The total cost was evaluated by adding initial investment to operational cost considering efficiency of equipment, cost of equipment, fuel and electricity. To confirm the validity of the developed program, a hotel building with an area of $127,960m^2$ was selected, and the simulated results were compared with the measured data. The difference between the simulated and the measured values for the selected hotel building was approximately 12% for annual electric consumption.

바이오매스 플라이애시를 활용한 무시멘트 경화체의 특성 (Properties of Non-cement Matrix Using Biomass Fly Ash)

  • 김대연;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.185-186
    • /
    • 2020
  • This study In order to reduce the amount of cement that generates a large amount of carbon dioxide and attempts to find a recycling method to solve environmental problems by using biomass fly ash. Experiments were conducted according to replacement ratio of biomass fly ash based on GGBFS, The test items are flowability, air content, unit volume weight, water absorption, flexural strength and compressive strength. As a result of the experiment, as increased replacement ratio of biomass fly ash, the flowability and air content was increased. As increased replacement ratio, the density was decreased and water absorption was increased. The compressive strength tended to decrease as increased replacement ratio. The flexural strength tended to increased as increased replacement ratio.

  • PDF

가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발 (The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology)

  • 박찬일;류기윤
    • 한국가스학회지
    • /
    • 제25권3호
    • /
    • pp.27-38
    • /
    • 2021
  • 본 연구에서는 가스보일러 가동 중 배기통이 이탈하는 상황이 발생했을 때, 시스템적으로 인지하고 자동으로 보일러 가동을 중지하여 일산화탄소를 포함한 유해 배기가스가 실내로 유입되는 상황을 근원적으로 차단하는 방안을 제시하였다: (1) 연소에 필요한 공기량을 제어하기 위해 설치된 풍압센서(APS : Air Pressure Sensor)의 출력전압을 측정하여 배기통의 정상상태와 이탈상태를 감시하는 기능을 추가한다. (2) 배기통이 이탈하면 APS의 출력전압이 상시 운전범위에서 일시적으로 상승하게 된다. 보일러 제어부인 PCB가 이 상태를 배기통 이탈로 간주하여 보일러 가동을 멈추면서 배기통 이탈 상태를 실내온도 조절기에 표시하도록 한다. 또한 국토교통부령으로 정한 「건축물의 설비기준 등에 관한 규칙」에서 명시한 공동주택 및 다중이용시설의 환기시설 기준에 따라, 실내공기 교환횟수에 맞는 풍량을 적용하여 실내공기를 환기하는 실험을 실시하였다. 이 실험 결과 실제 일산화탄소가 실내에 누출된 최악의 상태에서, 중독사고 예방이 가능하다는 것을 확인하였다. 다만, 동 규칙에서 정의한 시간당 실내공기 교환횟수를 기존 0.7회에서 0.5회로 2013년부터 완화하여 운영하고 있는데, 실험결과 8시간 가중평균 노출기준인 TWA 30 ppm을 초과하는 농도가 측정되어 기준을 강화할 필요성이 있다. 본 연구 결과에 기초하여 가스보일러 배기압력의 기계적 인지를 통해 배기통 이탈을 감지하는 기술과 일산화탄소 경보기와 연동된 실내공기 환기시스템 기술을 도입한다면 일산화탄소 중독사고가 크게 감소될 것으로 판단된다. 제조 및 검사단계의 문제점을 보완하고, 올바른 설치 및 수리, 사용자의 배기통 이탈에 대한 관심이 더해졌을 때, 일산화탄소 중독으로 인한 인명사고를 예방하는데 효과적인 대책이 될 것으로 사료된다.

부분부하 특성을 고려한 열원기기의 운전성능 평가 (EA Study on the Operation Performance of Central Plant Equipment According to Part Load Characteristics)

  • 이왕제;강은철;이의준;오병칠;신우철
    • 설비공학논문집
    • /
    • 제25권7호
    • /
    • pp.392-397
    • /
    • 2013
  • To fulfill the demands concerning energy efficiency for zero energy buildings, various technologies of architects and engineers are required. This study aims to estimate the thermal performance of heat source equipment in which part load characteristics are considered in an office building. Overestimation of heat source equipment was reviewed through literature survey, and heating and cooling loads depending on the capacity and division of the equipment were analyzed through a simulation program (DOE-2.1E). The conclusions gained from this study are as follows; 1) The more the division of equipment, the less the heating and cooling energy consumption. 2) When a large item of equipment is divided into two small items of equipment, the optimum application rate showed as 5:5 for chiller, and 7:3 for boiler, respectively.

집단에너지 열연계운전 분석을 위한 시뮬레이터 개발 (Development of a simulation program for the analysis of a thermal networking operation in District Heating)

  • 임용훈;박화춘;정모
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.825-832
    • /
    • 2008
  • A simulation program is developed for analysing thermal networking process between the District heating and the CES(Community Energy Supply) systems. The effects of thermal networking on the District heating facilities previously being operated are implemented using mathematical correlations in terms of the fuel consumption and energy load such as heating and electricity. The operational characteristics according to the prime movers is modeled based on the materials of efficiency as a function of operational load. The unit energy load model is also developed extensively for several building types such as apartment complex, hotel, hospital, buildings for business and commercial use respectively. The specific features of the newly developed program in simulation of thermal networking process in district heating is described in terms of the reliability and the easiness for operating it etc.

  • PDF

업무용 건물의 지열 히트펌프 시스템에 대한 성능 예측 (Performance Prediction on the Application of a Ground-Source Heat Pump(GSHP) System in an Office Building)

  • 손병후;권한솔
    • 설비공학논문집
    • /
    • 제26권9호
    • /
    • pp.409-415
    • /
    • 2014
  • Ground-source heat pump (GSHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy efficiency. These systems use the ground as a heat source and the heat sink for cooling mode operation. The purpose of this simulation study is to evaluate the performance of a hypothetical GSHP system in an office building and to assess the energy saving effect against the existing HVAC systems (boiler and turbo chiller). We collected monthly energy consumption data from an actual office building ($32,488m^2$) in Seoul, and created a model to calculate the hourly building loads with EnergyPlus. In addition, we used GLD (Ground Loop Design) V8.0, a GSHP system design and simulation software tool, to evaluate hourly and monthly performance of the GSHP system. The energy consumption for the GSHP system based on the hourly simulation results were estimated to be 582.6 MWh/year for cooling and 593.2 MWh/year for heating, while those for the existing HVAC systems were found to be 674.5 MWh/year and 2,496.4 MWh/year, respectively. The seasonal performance factor (SPF) of the GSHP system was also calculated to be in the range of 3.37~4.28.

전통민속마을의 주거변형실태에 관한 연구 - 낙안민속마을을 중심으로 - (A Study on the Deformation of Folk Village)

  • 박익수
    • 한국농촌건축학회논문집
    • /
    • 제6권3호
    • /
    • pp.63-74
    • /
    • 2004
  • This study is focusing on the Nagan Folk Village, primarily because of its historical and cultural values. The purpose of this study, accordingly, analysis the fact of the dwelling change through spot-survey and case-investigation, and is to find a way to improve for the rational preservation of the traditional dwelling analyzing on the actual condition and the reason for such changes in the Nakan Folk Village. The dwelling change is stemmed from the physical factors, and some modifications of internal composition, exterior formation, building equipment. As a result, The changes of internal composition are included in the reduction of garnering room, the enlargement of bed/service room, the establishment of mechanical room. The changes of exterior formation with structural material are included in the glass door for the internalization of 'TOEMARU', the extra glass door for the brightening of room, the cement plastering for the endurance of wall. The changes of building equipment are included in the establishment of oil-boiler, wash closet, sink for convenient life All houses should be graded on their qualitative value, managed in a cycle. And its own criterion for acceptable deformations should be established.

  • PDF

지오폴리머 기반 순환골재 혼입율에 따른 친환경성 인조석재의 특성 (Properties of Eco-friendly Artificial Stone according to the mixing ratio of Geopolymer-based recycled Aggregate)

  • 경석현;최병철;강연우;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.126-127
    • /
    • 2020
  • Recently, as interest in environmental issues increases, minimizing carbon dioxide generated during cement manufacturing is a problem to be solved. In order to solve such a problem, it is required to use an industrial by-product of recycled aggregate, blast furnace slag, and circulating fluidized bed boiler fly ash to replace it on the basis of geopolymer(=cementless). This study examines the characteristics of eco-friendly artificial stone according to the mixing ratio of geopolymer-based recycled aggregate. As a result of the experiment, when the addition rate of the alkali stimulant was 15% and the mixing ratio of the circulating aggregate was 70%, the flexural strength and compressive strength were the highest. Density and water absorption decreased as density of circulating aggregates increased and water absorption increased. However, when the mixing ratio of the circulating aggregate exceeded 70%, the flexural strength and compressive strength decreased. Therefore, in order to obtain strengths meeting the KS standards, the mixing ratio of recycled aggregate was set to 70%, and artificial stone was manufactured using industrial by-products.

  • PDF