• Title/Summary/Keyword: boil test

Search Result 32, Processing Time 0.023 seconds

Studies on the Calculating Method of Conditioned Weight by dry Weight after Boiling-off in Raw Silk (생사정량산정에 있어서 연감후 무수량의 도입에 관한 연구)

  • 김수현;이상근;김영진
    • Journal of Sericultural and Entomological Science
    • /
    • v.13 no.1
    • /
    • pp.73-78
    • /
    • 1971
  • The purpose of this study is to find out the method of conditioned weight test by which the dealing weight of raw silk can be calculated from true fiber in order to do the fair trading. The results of this study were as follows. 1. It is more reasonable than the current test that conditioned weight as a dealing weigh can be calculated by boil-off and moisture regain which is a percentage of boil-on and moisture regain to net weight. Because the boil-off and moisture regain can show directly the amount of true fiber and reproductibility in raw silk. In this study the boil-off and moisture regain is to take dry weight after boiling-off from net weight. 2. To calculate the conditioned weight from boil-of and moisture regain it would be proper that the standard additional ratio is 44 per cent of dry weight after boiling-off. 3. Boil-of percent of the sizing sample skein used in the size test did not show a statistical significance comparing with the boil-off percent of sample skeins (24 skeins) which may represent that of a lot. To observe this result boil-off percent of the sizing sample skein may represent that of a lot. 4. In Korea if conditioned weight test substitute for test of boil-off and moisture regain, we make a profit of two billion won in a year at the current market-price.

  • PDF

Fundamental Studies on the Boiling off Test of Raw Silk (생사연감검사에 관한 기초시험)

  • 김현수;이덕로;김영진
    • Journal of Sericultural and Entomological Science
    • /
    • v.13 no.1
    • /
    • pp.69-72
    • /
    • 1971
  • 1. To study proper sample size in boiling-of test, we extracted samples in size of 200, 100, 50, 20, and 10 grams and tested them. In the result of this test we couldn't find a statistical significance among them, but it is seemed that the proper sample size is 100 gram to think about the errors of measurement and treatment when the sample size is either too little or too much in ordinary test. 2. We tested boil-of result by twisted sample skein (sizing skein) and untwisted sample. In this test to use sodium carbonate (Na$_2$CO$_3$) having powerful sericin dissolving power as a scouring agent, boil-off percents made no statistical significance between two kinds of sample skein. And to use marseilles soap having less powerful sericin dissolving power as a scouring agent, boil-off percents made a difference between twisted and untwisted sample skein. 3. We compared five kinds of scouring agent, for example sodium carbonate, monogen, synthetic detergent (HiTi), marseilles soap A (made in Japan) and marseilles soap B (made in Korea). Among them synthetic detergent and marseilles soap B showed no statistical significance compared with marseilles soap A which we used in ordinary boil-off test. So synthetic detergent and marseilles soap B can be substituted for marseilles soap A. 4. Generally the higher pH value of boil of solution, tile more sericin dissolution, showed and vice versa.

  • PDF

Effect of Mixing and Placing in Hot Weather on Hardened Concrete Properties

  • Ham, Suyun;Oh, Taekeun
    • International Journal of Concrete Structures and Materials
    • /
    • v.7 no.2
    • /
    • pp.165-174
    • /
    • 2013
  • Portland cement concrete exposed to high temperatures during mixing, transporting, casting, finishing, and curing can develop undesirable characteristics. Applicable requirements for such the hot weather concrete differ from country to country and government agencies. The current study is an attempt at evaluating the hardened properties of the concrete exposed to hot weather in fresh state. First of all, this study reviews the current state of understanding and practice for hot weather concrete placement in US and then roadway sites with suspected hot weather concrete problems were investigated. Core samples were obtained from the field locations and were analyzed by standard resonance frequency analysis and the boil test. Based on the results, there does not appear to be systematic evidence of frequent cracking problems related to high temperature placement. Thus, the suspicious deteriorations which are referable to hot weather concreting would be due to other factors.

A Study on Thermal Performance Evaluation Procedures of LNG Fuel Tank (LNG 연료탱크의 단열성능 평가 절차에 관한 연구)

  • Cho, Sang-Hoon;Sim, Myung-Ji;Jung, Young-Jun;Kim, Ik-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.45-52
    • /
    • 2018
  • As guidelines for exhaust gases of ship are reinforced by the International Maritime Organization, the necessity for LNG fuelled ship is emerging. The relevant research is actively progressing to develop technologies and promote commercialization. When the residual quantity of LNG fuel tank is less than 70% by consuming fuel during operation, sloshing should be considered. We applied the Type C LNG fuel tank because medium sized LNG fuelled ships are difficult to equip with re-liquefaction system. Structural integrity and thermal performance are very important, especially in LNG fuel tanks that apply to LNG fuelled ship. Through this study, we proposed evaluation procedure of thermal performance for the Type C LNG tank, and verified the validity and effectiveness of BOR(Boil-Off Rate) test Procedure by comparing and analyzing changes in temperature, pressure, BOG(Boil-Off Gas).

Experimental Analysis of Boil-Off Gas Occurrence in Independent Liquefied Gas Storage Tank (독립형 액화가스 저장탱크의 BOG 발생에 대한 실험적 분석)

  • Cha, Seung-Joo;Bae, Jin-Ho;Lee, Dong-Ha;Kim, Tae-Wook;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.380-385
    • /
    • 2018
  • With the tightening of environmental regulations (i.e., IMO Tier III), natural gas (NG) has been spotlighted as an eco-friendly fuel with few air pollutants other than nitrogen oxides (NOx) and sulfur oxides (SOx). For reasons of economic efficiency, it is mainly stored and transported in a liquid state at $-163^{\circ}C$, which is a cryogenic temperature, using a liquefied gas storage tank. Accordingly, it is necessary to reduce the boil-off gas (BOG) occurrence due to the heat flow according to the temperature difference between the inside and outside of the storage tank. Therefore, in this study, a BOG measurement test on an independent-type storage tank made up of SUS304L was carried out. The test results showed the tendency for BOG occurrence according to the temperature under different filling ratios.

Insulation Performance and BOR of Pressurized Large-capacity Liquid Hydrogen Storage Tank (가압식 대용량 액체수소 저장탱크의 단열 성능과 BOR)

  • HEUNG SEOK SEO;YEONGBUM LEE;DONGHYUK KIM;CHANGWON PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.6
    • /
    • pp.650-656
    • /
    • 2023
  • In order to efficiently control boil-off rate of a liquefied hydrogen tank, the important thing is to maintain an appropriate vacuum level. however, compared to small and medium-sized storage tank, it is very difficult to create and maintain vacuum in large-capacity storage tanks. In this study, we aim to determine the target level of future large-capacity storage tank technology development and secure basic data on performance test methods by analyzing the corelation between evaporation gas and thermal conductivity of liquefied hydrogen storage tanks.

Measurement of Heat Leak through Multi-Layer Insulation (적층단열재의 열침입량 측정)

  • Kim D. L.;Yang H. S.;Jung W. M.;Lee B. S.;Shin P. K.;Hwang S. D.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.39-42
    • /
    • 2005
  • In this paper, the thermal characteristics of multilayer insulation (MLI) were experimentally investigated by using boil-off calorimetry method for seeking optimum standards of thermal insulation conditions. It is necessary to design the thermal insulating efficiency for applying to cryogenic instruments such as HTS power cable system. It is well known that the thermal characteristics and heat transfer of MLI are greatly affected by various MLI structures such as the number of layers and layer density, etc. However, it is difficult to know the thermal characteristics of MLI correctly. The heat leak by MLI between room temperature and liquid nitrogen temperature was measured at various conditions using a cylindrical cryostat. The cryostat consists of two guard vessels located at both end sides and a test vessel between them. The guard vessels are also filled with liquid nitrogen to prevent radiation heat leak through the both end side of the cylindrical test vessel to measure the heat leak only through MLI.

A Study on the Women's Behavior of Underwear Consumption (여성의 내의 소비 행동에 관한 연구)

  • 정혜원
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.3_4
    • /
    • pp.422-432
    • /
    • 2004
  • This study investigated underwear consumption behavior of women, who were 20∼59 years old and resided in Incheon during 2002 summer. 372 women completed questionnaires, and data were analyzed using factor analyses, t-test, ANOVA, $\chi$$^2$-analyses. They usually purchased underwear considering comfort and economic factor at a discount store. They wore sleeveless T-shirts, but they didn't wear underpants except panties highly all the year round. Higher rate of them wore pantyhose instead of underpants during autumn, winter and spring. They demanded unstitching of stitches and lengthened sleeves in most of the groups. And older and lowly educated women group wanted widen armhole of upper underwear, and tighten waistband of panties. They generally washed in washing machine using cold water. Besides they added oxygen bleach and softner during wash and final rinse. Older than 20's boil their underwear frequently. The women in a group of boiling commonly answered the looseness of waistband. It is recommended not to boil but to soak with bleach added warm water for improving the whiteness and durability of underwear. For a treatment with higher temperature deprives the elasticity of spandex.

Manufacturing and Tests of Cryostat for SMES (I) (SMES용 Cryostat 시제작 및 평가 (I))

  • 조전욱;심기덕;하홍수;김해종;김봉태;성기철;권영길;류강식;고득용
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.117-120
    • /
    • 2001
  • In this paper we present the results of manufacturing and tests of prototype cryostat for micro-SMES. The prototype cryostat with HTS current leads and refrigerator had been designed and manufactured for micro-SMES. The cryostat had been tested the helium boil-off and mechanical stress during transfer and vibration test. These results will be applied to micro-SMES cryostat.

  • PDF

Manufacture and Tests of Cryostat for Micro SMES (Micro SMES용 크라이오스테l트 제작 및 특성평가)

  • 조전욱;심기덕;하홍수;김해종;성기철;권영길;고득용;염한길;류충식
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.44-48
    • /
    • 2001
  • SMES consists of Superconducting magnet, a power converter, a cryostat and HTS current leads The prototype cryostat with HTS current leads and refrigerators was designed and manufactured for developing micro SMES. The temperature rise under dc current in HTS current leads was measured. The performances of helium boil-off and mechanical stress were evaluated during transfer and vibration tests. The results will be used to develope the micro-SMES system.

  • PDF