• Title/Summary/Keyword: boil

Search Result 252, Processing Time 0.024 seconds

Experimental research about thermal insulation performance of various powder insulation methods (다양한 파우더 충전 단열 방법의 단열 성능에 대한 실험적 연구)

  • Kim, H.S.;Jeong, S.;Jeong, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.49-54
    • /
    • 2010
  • This paper presents apparent thermal conductivity of various powder at different vacuum levels for cryogenic insulation. Four kinds of powder insulator are examined by using boil-off calorimetry at pressure range from 50 Torr to 3 mTorr. The first material is perlite which is widely used in cryogenic application. Microsphere is the second one that is recently proposed as a replacement powder for liquid hydrogen storage tanks. It is a hollow sphere made of silica with the diameter in the order of 10 to $100{\mu}m$. Popped rice and polystyrene beads are also selected as candidates for powder insulation even though they are polymers. With their porous elliptic and spherical configuration and light density, they demonstrate fairly good thermal insulation performance at pressure range from 50 Torr to 3 mTorr. According to the experimental investigation in this paper, microsphere and polystyrene beads possess promising insulation characteristic as powder insulators and further study is desired.

Analysis of LH2 Tank Behavior through Computational Simulation of C-Type LH2 Carrier on Voyage and Unloading Process (C-Type LH2 운송선박 운항 및 하역공정 전산모사를 통한 LH2 탱크 거동 분석)

  • DONGHYUK KIM;YEONGBEOM LEE;HEUNGSEOK SEO;YONGGI MO;CHIHUN LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.827-837
    • /
    • 2022
  • If the hydrogen industry is activated, the introduction of C-type and pressurized liquefied hydrogen (LH2) tank suitable for small and medium-sized transp- ortation and storage will be given priority in the future. Therefore in this paper, the behavior for the LH2 property changes and boil-off gas (BOG) treatment of the C-type cargo tank through voyage of the LH2 carrier and pressurized tank of the LH2 receiving terminal were analyzed through computational simulations by making assumptions about the carrier operation and unloading conditions.

CFD procedure of Multi-phase flow to predict the trend of Boil-off for the various filling ratio of C-Type liquefied hydrogen tank subject to sloshing motion (슬로싱에 놓인 C-Type 액화수소 탱크의 적재율에 따른 BOG 발생량 경향 예측을 위한 다상 유동 CFD 해석 절차)

  • Jin-Ho Lee;Sung-Je Lee;Se-Yun Hwang;Jang Hyun Lee
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.06a
    • /
    • pp.213-213
    • /
    • 2022
  • 본 논문은 슬로싱(Sloshing) 거동에 놓인 극저온 액체수소 화물창의 BOG 예측을 위한 CFD 해석 절차를 다루고 있다. 특히, 적재율(Filling Ratio)에 따라 달라지는 열 유입과 그에 따른 액체수소의 기화 경향을 파악하기 위한 목적으로 수행되었다. 액체수소와 기체수소의 혼재에 의한 다상 열유동(Multiphase-Thermal flow) 특성을 반영하고 유동에 따른 강제 대류 현상을 열유속에 반영하기 위한 CFD 해석을 수행하였다. 다상 유동 모델의 정확성을 검증하기 위하여 슬로싱 실험의 압력 계측 값과 해석의 압력 값 및 자유수면(Free surface) 형상을 비교하였다. 소형 C-Type 독립형 액화수소 탱크를 대상으로 슬로싱 유동과 BOG 발생을 수치적으로 예측하였다. 해석 과정에서 VOF(Volume of fraction) 모델과 Eulerian 모델을 모두 적용하여, 액체수소에 유입되는 열 유속(Heat flux)의 예측 정확성을 비교하였다. 슬로싱 유무에 따라 액체수소에 유입되는 열 유속을 비교하여 슬로싱 유동의 포함 여부에 따른 BOG 발생량의 변화를 제시하였으며, 최종적으로 액체수소의 충전율(Filling ratio) 별로 BOG 발생량의 경향성을 제시하였다.

  • PDF

A Study on Method of Selecting Five Su Point(五輸穴) According to the Turning of Season in "Hwangjenaegyeong(黃帝內經)" ("황제내경(黃帝內經)"의 사시별(四時別) 오수혈(五輸穴) 취혈법(取穴法)에 대한 소고(小考))

  • Kim, Jong-Hyun;Jeong, Chang-Hyun;Jang, Woo-Chang;Baik, You-Sang
    • Journal of Korean Medical classics
    • /
    • v.22 no.1
    • /
    • pp.121-130
    • /
    • 2009
  • Traditionally, Korean Medicine put emphasis on the treatment and health-preserve method that corresponds with circulation of nature. And acupuncture is no exception to this rule. In "Hwangjenaegyeong(黃帝內經)", some chapters present method that is changed according to the seasons. Among the chapters, there are some difference, but we can find a general theory. In spring, Yanggi(陽氣) is coming out but not strong and cannot diffuse. so the Yanggi(陽氣) hang up the middle of outer layer. Therefore, we can take some acupoints around the muscle interspace[分腠] or tiny branches of Meridian[孫絡]. In summer, Yanggi(陽氣) flourish and boil all around of the outer layer. So, we can take some acupunctural points from skin to the yang-meridian. In both fall and winter, five su point[五輸穴] make up almost of point. in fall, yanggi begin convergence. we can remove the Eum-pathogen[陰邪] and help the normal convergence by using Stream point[腧穴], River point[經穴] and Sea point[合穴]. In winter, Eum surround so solidly that the neo Yanggi(陽氣) cannot come out. So, we can break the yin by using Well point[井穴] and make be strong by Spring point[滎穴]. If we Study the method that correspond with the seasonal circulation more, we will be able to treat diseases more minutely.

  • PDF

A Study on the Dyeability and Physical Properties of Mordanted and natural-dyed Fabrics (천연염료의 매염에 따른 염색성 및 물성에 관한 연구;소목과 꼭두서니를 중심으로)

  • 차옥선;김소현
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.6
    • /
    • pp.788-799
    • /
    • 1999
  • This study was performed to investigate the effect of mordants on the dyeability colorfastness to light and to laundering and biological properties of mordanted and natural-dyed cotton and silk substrates. Natural red dyes were extracted from Caesalpinia Sappan L. (Sappan wood) and Rubia Akane Nakai (Madder) by boil water Five different compounds of Al, Cr, Cu, Fe and Sn were used as mordanting agents. The result of this study are sumarized as follows ; 1. In the of the fabrics mordanted and dyed with sappan wood K/S value increases and λmax shifts to the longer wavelength as mordant concentration increases. Color of the fabrics dyed with sappan wood and madder change to redder bluer and lighter after mordanting. 2. As the number of repetition of dyeing-mordnating process increase the color of the dyed fabrics tend to be redder bluer and darker. Mordanted dyes with Al and Sn make chroma increase. The quantity of mordant absorbed in the silk fabric increase as mordant concentration increase. More Fe is absorbed in silk than Cr is. 3. After being exposed to light the fabrics dyed with sappan wood and madder change to less red Fe and Cu mordanting yeild better colorfastness to light than others does. Natural-dyed fabrics exposed to light tend to be faded and whitened in CIELAB chromaticity co-ordinates. So we might trace back the original color of ancient faded fabrics by changes in color of natural dyes. 4. After washing the colors of natural dyes change to more blue, Fe and Cu mordanting give better colorfastness to wash than others do. 5. The soil-burial cotton is more susceptible to mildew and rot than the silk is. Antimicrobial activity of the natural-dyed cotton can be enhanced by Cu and silk can be enhanced by Cu and Cr mordanting respectively.

  • PDF

A Study on Mitigating Accidents for Liquid Hydrogen (액체수소 사고피해 완화기술에 대한 연구)

  • Jo, Young-Do;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.29-33
    • /
    • 2012
  • This paper is an attempt to give a concise overview of the state-of-the-art in the recent liquid hydrogen safety researches with unwanted event progress. The vessel of liquified hydrogen may fail and liquid hydrogen spilled. The hydrogen will immediately start to evaporate above a pool and make a hydrogen cloud. The cloud will disperse and can produce a vapor cloud explosion. The vessel containing the liquid hydrogen may not be able to cope with the boil-off due to heat influx, especially in case of a fire, and a BLEVE may occur. In equipment where it exists as compressed gas, a leak generates a jet of gas that can self-ignite immediately or after a short delay and produce a jet flame, or in case it ignites at a source a certain distance from the leak (delayed ignition), a flash fire occurs in the open and with confinement a deflagration or even detonation may develop. The up-to-date knowledge in these events, recent progress and future research are discussed in brief.

Provenance and Concept of 10 Symptoms of Para-cold Damage(類傷寒) from Yixuerumen(醫學入門) (『의학입문(醫學入門)·상한편(傷寒篇)』 유상한(類傷寒) 병증(病症) 10종의 유래와 개념에 대한 연구)

  • Jo, Hak-jun
    • Journal of Korean Medical classics
    • /
    • v.29 no.4
    • /
    • pp.17-36
    • /
    • 2016
  • Objectives : This paper seeks to study the provenances of 10 Symptoms of Para-cold damage from Yixuerumen, and discovers the rationality and originality of para-cold damages recognized by Li Chan. Methods : The paper looks through the books referenced by Yixuerumen to investigate the source text for Yixuerumen's Para-cold Damage chapter, and the contents of the referenced books will be compared to that of Yixuerumen. Results : The sources of the 10 symptoms of para-cold damage from Yixuerumen Chapter of Cold Damage can be traced to Leizhenghuorenshu (expectoration, indigestion, rising temperature due to lack of energy, and beriberi), Wang Zhen's Shanghanzhengzhimingtiao Xinzengxuleishanghansizheng(the infection in a boil, blood sattis, caused overexertion, and pox), and Liu Chun's Yujiweiyi's chapter on Common Cold. Here, Li Chan made his own addition of internal damage and damage of overworking. Li Chan seems to have considered para-cold damage not as a type of cold damage but as a "concept relative to the broader range of cold damage." In reflection of this understanding, Li Chan limited the number of categories to ten in accordance with the developmental trace leading from Leizhenghuorenshu to Shanghanzhengzhimingtiao. When we understand para-cold damage as a "concept relative to the narrower range of cold damage," it could be used as a mean as for "Wenbin diagnosis," but Yixuerumen's para-cold damage is only utilized for the "diagnosis of a broader concept of cold damage." Conclusions : Li Chan deserves credits for his academic rationality and originality displayed by the method he used to form para-cold damages where he used real cold damage and para-cold damage as principles, by the division of para-cold damage symptoms into ten provenances, by the creation of the concept of para-cold damage, and by his broad collection of prescription and treatment corresponding to each type.

Numerical Model of Heat Diffusion and Evaporation by LNG Leakage at Membrane Insulation (LNG 화물창 방열재 균열에 따른 액화천연가스의 확산 및 온도 예측을 위한 수치 모델)

  • Lee, Jang Hyun;Kim, YoonJo;Hwang, Se Yun
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.517-526
    • /
    • 2014
  • The leakage of cryogenic LNG through cracks in the insulation membrane of an LNG carrier causes the hull structure to experience a cold spot as a result of the heat transfer from the LNG. The hull structure will become brittle at this cold spot and the evaporated natural gas may potentially lead to a hazard because of its flammability. This paper presents a computational model for the LNG flow and heat diffusion in an LNG insulation panel subject to leakage. The temperature distribution in the insulation panel and the speed of gas diffusion through it are simulated to assess the safety level of an LNG carrier subject that experiences a leak. The behavior of the leaked LNG is modeled using a multiphase flow that considers the mixture of liquid and gas. The simulation model considers the phase change of the LNG, gas-liquid multiphase interactions in the porous media, and accompanying rates of heat transfer. It is assumed that the NO96-GW membrane storage is composed of glass wool and plywood for the numerical simulation. In the numerical simulation, the seepage, heat diffusion, and evaporation of the LNG are investigated. It is found that the diffusion speed of the leakage is very high to accelerate the evaporation of the LNG.

Feasibility Study of Underground LNG Storage System in Rock Cavern (LNG 지하공동 비축시스템의 타당성분석)

  • Chung, So-Keul;Han, Kong-Chang;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.16 no.4 s.63
    • /
    • pp.296-306
    • /
    • 2006
  • It is difficult to solve problems regarding the adjustment on demand and supply of LNG due to seasonal variations of domestic demand of LNG, a discordance among import pattern and limits of storage facilities and so on. Also, there may be instability in LNG supply due to chances of accidents at LNG producing areas. Therefore, it is very important to secure large LNG storage facilities and to stabilize LNG supply management on a long term basis. The objective of this study is to examine the real-scale applicability of a lined underground rock storage system, which have been verified by a successful operation of the Daejeon LNG pilot plant. The new technology has many advantages of better economy, safety and environment protection, for above-ground and in-ground storage systems. The results of this study may promote the first ever real scale underground LNG storage system in a rock cavern.

A Study on the Strength Safety of the Prestressed Concrete Outer Tank for a Membrane LNG Storage Tank (멤브레인식 LNG 저장탱크용 PC 외부탱크의 강도안전성에 관한 연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.21-27
    • /
    • 2009
  • This paper presents the numerical study on the strength safety of the prestressed concrete outer tank for a LNG storage tank, which is manufactured by sets of membrane panels with special corrugations. This study for a finite element analysis assumes that the membrane panel of the inner tank was fractured and the liquefied natural gas stored in the inner membrane tank was leaked to the prestressed concrete outer tank. The stress and displacement of the outer tank have been analyzed for five different loadings, which are originated by a hydrostatic pressure and a weight of a LNG, a temperature difference, a weight of the prestressed concrete and a boil-off gas pressure. The computed FEM results indicate that the PC outer tank with a storage capacity of 200,000$m^3$ has a good strength safety for a leaked LNG from the membrane inner tank, but the increased cryogenic loadings in which are originated by a leaked LNG decreases the strength safety of the PC structure. This may lead to the collapse of the outer storage tank.

  • PDF