• Title/Summary/Keyword: body temperature measuring

Search Result 145, Processing Time 0.029 seconds

A Study on the Temperature Measuring System of an Oral Cavity (구강 내부 온도 계측을 위한 센서 시스템 연구)

  • Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1165-1169
    • /
    • 2007
  • In this study, a novel sensor system for measuring the temperature inside an oral cavity is proposed. With this aim, a small size of thermistor was used for resolving the cavity's temperature with the resolution of $0.1^{\circ}C$. To evaluate effectiveness of our sensor system, the temperature and its output voltage characteristic, and the specifications of response are investigated. It turned out to be that our sensor system has a linear property in terms of temperature variations for a healthy subject's body temperature range and has a good response time within 3 seconds. Also, in order to investigate the medical application, our sensor system is sought to measure the real temperature variations of a subject's oral cavity and ark shell especially for 'before' and 'after' exercise mode.

A Study on Emergency Monitoring Robot System by Back-Propagation Algorithm

  • Yoo, Sowol;Kim, Miae;Lee, Kwangok;Bae, Sanghyun
    • Journal of Integrative Natural Science
    • /
    • v.7 no.1
    • /
    • pp.62-66
    • /
    • 2014
  • This study aims to implement the emergency monitoring robot system which predicts the current state of the patients without visiting the medical institutions by measuring the basic health status of the user's blood pressure, heartbeat, and basic health status of body temperature in the disaster emergency situation based on the Smart Grid. By arranging a large number of sensor(blood pressure, heartbeat, body temperature sensor) and measuring the bio signs, so the attached wireless XBee sensor can be stored in DB of robot, and it aims to draw the current state of the patients by analysis of stored bio data. Among 300 data obtained from the sensor, 1st data to 100th data were used for learning, and from 101st data to 300th data were used for assessment. 12 results were different among the total 300 assessment data, so it shows about 96% accuracy.

The Foot Pressure Change Caused by Functional Leg Length Having an Effect on the Foot Temperature (기능적인 하지길이 차이에 따른 족저압 변화가 족부체열에 미치는 영향)

  • Kim, Minju;Kim, Juyeon;Lee, Hyewon;Yim, Juyeon;Ha, Hyunjin;An, Jinho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.1 no.2
    • /
    • pp.37-46
    • /
    • 2013
  • Purpose : The purpose of the research was to analyze foot pressure, foot temperature, and correlation between foot pressure and foot temperature to grasp impact on foot pressure and body temperature distribution chart depending on functional difference of leg length. Method : After measuring leg length, put 15 students whose functional difference of leg length was over 10mm to difference group and 15 students whose functional difference of leg length was under 5mm to normal group and categorize soles of foot into 6 sections of hallux head, 1st metatarsal head, 2-4 metatarsal head, 5 metatarsal head, lateral heel, and then measure by foot pressure analyzer to analyze characteristic of pressure distribution and classify into front of the lower leg, back of the lower leg, soles of foot and measure by body temperature analyzer to analyze by checking body temperature. Result : Weight difference depending on foot pressure and body temperature was bigger when functional difference of leg length was bigger, and it could be confirmed that foot pressure and body temperature of short leg side were higher than those of short leg side. Thus, if difference exists in leg length, weight load on short leg side increases which results in higher foot pressure and body temperature, therefore enabling an assumption that mechanical problem will occur in short leg. Conclusion : When functional leg length inequality, weight bearing and pressure was getting high as a result, temperature was getting high in short leg.

Development of Sensor Node for Temperature Monitoring of Livestock Based on IEEE 802.15.4 (IEEE 802.15.4 기반의 가축 체온 모니터링 센서 노드 개발)

  • Lee, S.J.;Kim, Do Hyeun
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.7
    • /
    • pp.886-894
    • /
    • 2014
  • Recently, domestic animal disease caused tremendous damage to farmhouses and the damage stretched in nationwide with the spread of epidemic disease. To prevent animal diseases from happening again, the system development to easily measure the temperature of sick animals and identify of them is needed, thereby quickly treat them, reducing losses of farmhouses. However, a lack of related equipment and human resource hampered its effort to minimize its losses. This study tries to develop diagnosis system as part of measures to curb these domestic animal diseases. This paper present the 센서 node based on IEEE 802.15.4 which can be attached to the animal body for real-time temperature measurement. We design and implement tiny chip-type that can be attached to the body of animals. Then, we use available power only when measuring temperatures in a long term-basis. In this paper, the 센서 node was applied to horse's neck. We measure the horse's body temperature between $32.2^{\circ}C{\sim}33.7^{\circ}C$ and analyze phenomenon data for 4 months.

Implementation of Unmanned Remote supervisory System having Multipurpose Measuring Modules

  • Park, Jung-Hoon;Hong, Sung-Hoon;Kang, Moon-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.132.1-132
    • /
    • 2001
  • In this paper, we have studied for development of unmanned remote supervisory system using mobile communication network, not wire network, not to be affected by space or distance. The unmanned remote supervisory system consists of data processing unit main part and measuring systems (modules part)-temperature measuring module, humidity measuring module and human body sensing module. The data processing unit to collect and process informations of each measuring module has the functions of data communication between a mobile cellular telephone and measuring systems. Each measuring module has supervisory and warning functions for a target of supervision. And then we have designed each system and evaluated accuracy and reliability of the combined total system.

  • PDF

Implementation of Measuring Modules & Data Processing Unit for Unmanned Remote Supervisory System (무인 원격감시 시스템용 계측 모듈 및 데이터 처리장치의 구현)

  • Park, Jung-Hoon;Hong, Sung-Hoon;Seo, Kang-Myun;Kang, Moon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2209-2211
    • /
    • 2001
  • Unmanned remote supervisory system consists of data processing unit and measuring systems-temperature measuring module, humidity measuring module and human body sensing module. The data processing unit to collect and process informations of each measuring modules has functions of data communication between a mobile cellular-telephone and measuring systems.

  • PDF

A Study on the Comfortability of Wearing Pantyhose (시판 Stocking의 착용에 따른 쾌적성 연구)

  • Sim, Bu-Ja;Park, Hye-Jun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.71-90
    • /
    • 1999
  • This study was conducted to examine the comfortability of wearing pantyhose in summer. To satisfy this purpose. 4 types of pantyhose were chosen from the market: a Mono type(M), a Wooly type(W), and two Support types(Sl, S2), were chosen. After the performances of samples were measured, these were worn by 8 healthy adult women. Under the summer field environment, psychological comfort ability was examined through the 5 steps of SD method. Physiological comfort ability was examined by measuring the body reactions(clothing pressure, skin temperature, total body weight loss, rectal temperature, pulse rates, and blood pressure), under the artificial environment($28.5{\pm}0.5^{\circ}C$, $82{\pm}3%$). The results of this examination were as follows : The order of comfortability which people felt in the field was W>M>S1>S2. The number of items which showed the highest correlation with comfort ability decreased and the correlation was lowered on the whole as time went by. There was positive high correlation between the performances of samples and comfort ability in compressibility, air permeability, water vapor permeability, while a negative high correlation in thickness, weight, compressional resiliency, strain (course) and moisture regain. The mean skin temperature was in the comfort zone, and rectal temperature, pulse rates, blood pressure were mostly in the normal range. Also it was showed that the correlation between the performance of samples and body reactions, except total body weight loss, was low.

  • PDF

Implementation of Measuring Modules for Unmanned Remote Supervisory System using Mobile Communication Network (이동통신망을 이용한 무인 원격감시 시스템용 계측 모듈의 구현)

  • Park, Jung-Hoon;Hong, Sung-Hoon;Seo, Kang-Myun;Kang, Moon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2416-2418
    • /
    • 2000
  • The new-type measuring modules for unmanned remote supervisory system using mobile communication network have been designed in this study. Measuring modules consist of temperature measuring module, humidity measuring module and human body sensing module. And we will design a main part to collect and process informations of each modules, evaluate reliability of combined total system.

  • PDF

Differences in ruminal temperature between pregnant and non-pregnant Korean cattle

  • Kim, Dae Hyun;Ha, Jae Jung;Yi, Jun Koo;Kim, Byung Ki;Kwon, Woo-Sung;Ye, Bong-Hae;Kim, Seung Ho;Lee, Yoonseok
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.36 no.1
    • /
    • pp.45-50
    • /
    • 2021
  • In recent years, various methods of measuring body temperature have been developed using wireless biosensors to facilitate an early detection of pregnancy and parturition in cows. However, there are no studies on real-time monitoring of cattle body temperature throughout pregnancy. Therefore, we investigated the daily mean ruminal temperature in pregnant cows throughout pregnancy using a ruminal bio-capsule sensor and then evaluated the temperature variation between pregnant and non-pregnant cows. In pregnant cows, the mean and standard deviation of ruminal temperature was 38.86 ± 0.17℃. Ruminal temperature in pregnant cows slowly decreased until 180 to 190 days after artificial insemination and after that, the temperature increased dramatically until just before parturition. Furthermore, the means ruminal temperature was significantly different between pregnant and nonpregnant cows. The mean and standard deviation of ruminal temperature were as follows: 38.68 ± 0.01℃ from days 80 to 100, 38.78 ± 0.02℃ from days 145 to 165, 38.99 ± 0.45℃ from days 200 to 220, 39.14 ± 0.38℃ from days 250 to 270 before parturition. Therefore, our results could provide useful data for early detection of pregnancy and parturition in Korean cows.

An Experimental study on the human's physiological in Smart Textile Materials by Using Medical Infrared Thermo graphic Imaging (적외선 체열 영상 진단법을 이용한 스마트 섬유소재와 휴대폰 통화량에 따른 인체 생리반응 연구)

  • Lee Tae-il;Lee Su-jeong;Lee Kyung-mi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.7 s.144
    • /
    • pp.918-925
    • /
    • 2005
  • The following are the results from the infrared body temperature image test to verify the changes in facial temperature according to call duration with a cellular phone. As for the body temperatures, it appears to be the mean value at the upper central point of phone's battery among 7 different points that are measured, and to be the highest at srernocleido-mastoid and scapular trapezius muscle triangle zone$(34.25^{\circ}C\; and\;34.05^{\circ}C\;each)$. The changes of body temperature according to the time duration shows that the body temperature rises according to the length of phone use because of the heat emitted from the battery. As for the temperature changes according to blocking materials, the one without processing appears to be higher in the mean temperature compared to the others that are processed, NSS(Nano Silver Silk) and NSG(Nano Silver Silk Gold) appear to be the lowest in the temperature to show the best blocking property. As for the temperature changes according to measuring points, it appears to be the highest at P4, P5 with all materials, and one with NSG to be the lowest at Pl, P2, P3, and one with NSS to be the lowest at P3, P4, P5, P6, which is due to the thermal conduction of Au and Ag. And the mean temperature at each point appears to be different according to the materials. Therefore, the study conducted with human participants requires a proper particle size of it which would not penetrate cellular tissues and a proper binder and binding treatment for it, to prevent the physical fatigues and the potential diseases. However, it is highly required for back-up researches to verify various aspects in applying nano silver to textile products.