• 제목/요약/키워드: body scanning

검색결과 470건 처리시간 0.029초

자루이형흡충(Stictodora fuscatum)의 표면 미세구조 (Surface Ultrastructures of Stictodora fuscatum (Trematoda: Heterophyidae))

  • 손운목
    • Applied Microscopy
    • /
    • 제30권2호
    • /
    • pp.205-212
    • /
    • 2000
  • Present study was performed to observe the surface ultrastructures of Stictadora furcatum (Trematoda: Heterophyidae). Adult worms were recovered from the cat experimentally infected with metacercariae, and were prepared for scanning electron microscopy. The body was leaf-like and ventrally concave. The oral sucker armed with prominent tegumental spines on the inner surface, and it's lips were obscure. Sensory papillae (type I) in single or grouped forms symmetrically arranged around the oral sucker. The ventrogenital opening retained protruding gonotyl spines and sperms discharged from the genital pore . The body surface was covered with scale-like multipointed tegumental spines. The density and digitated point of spines were gradually decreased toward the posterior end of the body. The digitated points of spines on the anterior portion were 9-12, on the middle were 7-8 and 5-6, and on the posterior were 2-3 and peg-like. Although the tegumental ultrastructure of S. fuscatum was generally similar to those of other heterophyid flukes , the oral sucker with tegumental spines on the inner surface and without obvious lips, and the ventrogenital opening with protruding gonotyl spines were suggested to be the characteristic features.

  • PDF

몬테카를로 방법을 적용한 bed type 전신계측기의 방사선작업종사자 외부오염 검출 응용 (Application of the Detection of External Contamination on Radiation Workers for Bed Type Whole Body Counting Using Monte Carlo Method)

  • 김정인;이병일
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.242-245
    • /
    • 2013
  • 원전 방사선작업종사자의 내부선량평가를 위해 일반적으로 사용되고 있는 bed type 전신계측에 몬테카를로 방법을 적용하여 작업자에 대한 외부오염 계측특성을 평가하였다. 한국인 체형을 반영하는 voxel 모의 피폭체를 이용하여 내부오염시 측정 특성을 평가하였다. 외부오염 판별을 위해 BOMAB 모의 피폭체를 이용하여 신체 각 부위별 오염시 나타나는 측정 특성을 평가하였다. 가슴 부위 오염시 누운 자세와 엎드린 자세로 구분하여 외부오염시 계측 특성을 확인하였다. 정량적인 분석을 통해 bed type 전신계측기를 이용한 외부오염 판별이 가능함을 확인하였다.

Comparison of Virtual Avatars by Using Automatic and Manual Method

  • Lim, Ho-Sun;Istook, Cynthia L.
    • 한국의류학회지
    • /
    • 제34권12호
    • /
    • pp.1968-1979
    • /
    • 2010
  • New technology that includes 3D body scanning, digital virtual human, and digital virtual garments has had a significant impact on the current apparel industry. Virtual simulation technology enables the visualization of a 3D virtual garment on a virtual avatar so that consumers can try on garments with their virtual avatars before purchasing. However, the manual virtual avatar provided for online apparel shopping currently has revealed limitations on the different body sizes and shapes of customers. This study analyzes the process of designing the automatic virtual avatar and the manual virtual avatar using OptiTex software; in addition, the study compares the practicality of the automatic virtual avatar with that of the manual virtual avatar. Data was examined by evaluating how much each virtual avatar is similar to the real body and how well it matched the needs of the current apparel industry. In the study, Avatar 1 was automatically created from three-dimensional body scan data and Avatar 2 was manually created from body measurements. The virtual avatar images laid over a real body image and the results were evaluated by comparing the simulated sizes of virtual avatars with those of a real body. Consequently, Avatar 1 was evaluated as more similar to the real body than Avatar 2 in all five body shapes. This study illustrates that an automatic virtual avatar might solve the fit problem that is the most common reason for a high return rate for online shopping. The results show that future virtual simulation technology needs to be improved for the practicality of the virtual avatars.

Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구 (Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System)

  • 윤한식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

전산화(電算化) 단층촬영기(斷層撮影機)의 보유현황(保有現況) 및 이용실태(利用實態) (부산시내(釜山市內) 병원(病院)을 중심(中心)으로) (A Study on the Status and Utilization of Computed Tomography Units in Pusan Area)

  • 오문영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제14권1호
    • /
    • pp.29-44
    • /
    • 1991
  • A Study on the distribution and types of the total 40 CT units, as of 1st October 1990, in Pusan area(29 for whole body CT units, 11 for brain CT units) were carried out during the period from January 1989 to December 1989 to find out the status of operation and utilization of whole body CT units. The results were as following ; 1. As of 1st October 1990 in Pusan area, a total of 40 CT units(29 for whole body CT units, 11 for brain CT units) were set up and operated. The number of cases of CT examination performed per day per unit were appeared to be less than 5 cases among 59.5% of CT units, and 2.7% of the total units has peformed more than 16 examinations. 2. The CT units under operation occupied 93.5% of the total and 2.6% of the total units was not properly been operated due to mechanical breakdown. This results is appeared to be better than other reports. 3. The average number of scanning per week for each CT were 35 cases and the average days under operation of the unit per week were 6.7 days. Consequently, the average days under operation of units was higher than that of the other reports, but the average number of scanning was lower. 4. The cases referred from other institutes to hospitals were 6.4% of total cases. 5. As a site of scanning, the brain appeared most frequently with 71.2% of the total cases and followed by spine 12.4%, abdomen 8.5%, and thorax 3.6%, respectively. 6. Positive rate by scanning was 70.8% of total cases, and it was 98.9% with thorax, abdomen 96.3%, spine 93.1%, and brain 38.4%, respectively. According to the results of this study, it is highly recommended that the regulations and the guidelines for setting-up of such high cost medical equipments as CT units be provided in order to ensure the cost-effectiveness of the system.

  • PDF

비수도권(非首都圈) 지역(地域)에서의 전신용(全身用) X선(線) CT의 이용(利用) (Utilization of Body Computed Tomography Scanners in Non-Metropolitan Area)

  • 박영선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.29-45
    • /
    • 1985
  • Computed Tomography Scanner (CT) is highly expensive in operation as well as purchasing. That reason may cause not only to increase the burden of patients but also to waste the capital resources leading to financial difficulties. However the numbers of CT installed throughout the country is increasing, because of efficiency in medical care, patient's concern, competitions among the hospitals within the same area. In the non-Metropolitan area the scanners were expected to be less utilized and less profitable. Nine hospitals equipped with the CT were studied on the utilization of that equipment during the period from November 1984 to February 1985 in non-Metropolitan area and break-even point in one hospital was analyzed for estimating profitabilities. The results were as follows ; 1. Among those nine hospitals, four hospitals had less than 400 beds, which is one of the restrictive minimum standards on the installation of Whole-body Computed Tomography Scanner. 2. The operating time during the normal operation period was longer than those of any other studies, but the accumulated down time was also longer than those of any other studies. The average number of scanning per week for each CT was 45, while the estimated number of for the break-even point was 56.7 cases. 3. When the downtime was excluded in calculating the average operation would be much closer to the cases for the break-even point. Therefore the break-down of the equipment was to be a main cause of the low profitability. 4. The average scanning rate for head area was 33.6%, however three of the nine hospitals showed about 20%. 5. If scanning ratio for the body parts excepting head was increased, the number of scanning for the break-even point would be diminished. 6. The small size hospital especially located near the Metropolitan area showed largest loss in the CT operation. In purchasing the highly expensive equipments in hospitals, demand should be taken into account and planning is recommended.

  • PDF

전산화 단층사진술에 의해 예증된 구치부 무치악 하악골의 골개조 (The Remodeling of the Posterior Edentulous Mandible as Illustrated by Computed Tomography)

  • 박창서
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.43-53
    • /
    • 1999
  • Purpose: The aim of this study was to analyze radiologically the location and course of the mandibular canal and to observe the alveolar and basal bone changes during the remodeling procedures of atrophic mandible. Materials and Methods: CT scanning was performed on dry 30 edentulous or partially dentulous mandibles. In 48 edentulous lower halves, measuring areas were determined by three points in the length of the mandibular canal. The distance from the mandibular canal towards cranial and caudal edges, buccal and lingual external borders of the body of the mandible were measured. A statistical comparison between the mean values of different classes of mandibular body was carried out in the selected areas. Results: The distance between the mandibular canal and caudal borders of the body of the mandible and lingual borders dose not change in the atrophic process of mandible. The mandibular canal within the mandible courses downwards from mandibular foramen towards mesial and subsequently it gets to the mental foramen. The distance between the mandibular canal and buccal external border of basal bone changes similar to the change of cranial borders of alveolar bone in the atrophic process of mandible. Conclusion: CT scanning was very effective and practicable to analyze the location and course of the mandibular canal and to observe the alveolar and basal bone changes of atrophic mandible. Also more detailed investigation of basal bone changes observed during the remodeling procedures of atrophic mandibles seems reasonable to rely on the massive anthropologic collections of atrophic mandibles combined with CT scanning.

  • PDF

인체모델과 3차원 일러스트레이션을 이용한 의복패턴개발 (Direct Clothing Pattern Development from the 3D Illustration on the Personal Human Body Model)

  • 박혜준;홍경희
    • 한국의류학회지
    • /
    • 제32권2호
    • /
    • pp.340-347
    • /
    • 2008
  • A prototype of 3D clothing design system with a direct pattern development function was suggested, reflecting intuitive design functions and design modifications while considering the fit of clothing patterns with the 3D human body in the virtual 3D space. The research method was as follows. Clothing models were created using a 3D design tool, 3ds max on the surface of 3D human body model made by scanning an actual human body. 3D illustrations were completed by revising the fit and sizing of the human body and clothing models. 2D T-shirt pattern was produced 3D illustrations using from a 3D scanning data modeling solution RapidForm 2004, a 2D conversion program for 3D data called 2C-AN, and Yuka CAD. As a result, the following conclusions were made. The fit of the clothing and human body can be adjusted by reflecting individual body figure characteristics and 3D illustrations over the actual 3D body model. Furthermore, intuitive design support functions were intensified overcoming the weak point of existing 3D clothing design system by developing the direct clothing design in the virtual 3D space. 3D illustration design modifications can be directly reflected on clothing patterns from 3D illustrations by 3D clothing design system developed in this study.

3차원 스캔 기술과 니트 소재의 신축성을 적용한 밀착형 스포츠웨어 상의 설계 (Technical Design of Tight Upper Sportswear based on 3D Scanning Technology and Stretch Property of Knitted Fabric)

  • 김태규;박순지;박정환;서추연;최신애
    • 한국의류산업학회지
    • /
    • 제14권2호
    • /
    • pp.277-285
    • /
    • 2012
  • This research studied how to develop tight upper sportswear from 3D scan data considering fabric stretch property. Subjects were five Korean men of average figure in their 20's. Scanning was done for ten postures via vitus smart/pro(Techmath LTD). Analyzing from 3D scan data, more than 70% of the upper body surface showed surface change rate under 20%. It was shoulder and under arm side part that showed most noticeable body surface change when moving. A parametric model with convex surface was generated and flattened onto the plane, resulting 2D pattern. The error rate occurring in the process of 3D to 2D conversion was 0.2% for outline and 0.13% for area, respectively. Thirteen kinds of stretchable fabrics in the market were collected for this study. Stretch property was in the range of 16.0~58.2% for wale direction; 23.1~78.4% for course. Based on wear trial test, four fabrics were chosen for making the 1st experimental garment and finally one fabric was chosen for the 2nd one, which was developed applying 4 kinds of crosswise reduction rate on 2D pattern: 0, 5, 10, and 15%. Through wear trial test and garment pressure measurement, experimental garment applied with 10% pattern reduction rate was evaluated as most comfortable and considerable.