• Title/Summary/Keyword: body image

Search Result 2,321, Processing Time 0.031 seconds

Effects of Eucommiae Cortex (杜冲) on the Bone Histomorphometry and Metabolism in Ovariectomized Rats (두충(杜冲)이 난소적출(卵巢摘出) 흰쥐의 골조직(骨組織) 형태(形態)와 골대사(骨代謝)에 미치는 영향(影響))

  • Yang, Sung-Woo;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.18 no.1
    • /
    • pp.128-141
    • /
    • 2005
  • Objective : This study was undertaken to investigate the effects of Eucommiae Cortex on the osteoporosis in ovariectomized rats. Materials and Methods : We used Sprague-Dawley female rats in 8-week-old. They were divided into three groups. Sample group was ovariectomized and administered with 10 mg/100 g/day Eucommiae Cortex extract solution for 10 weeks. Control group was ovariectomized and sham group was conducted by sham's operation. And control group and sham group were administered with normal saline as the same way. We measured rats's body and uterus weight and also measured the serum levels of Ca, phosphorus and ALP. We stained the specimens of rat's tibial bones with Goldner's modified Masson's Trichrome and then examined bone histomorphometry with Bioquant computer program of image analysis system. We measured the thickness of osteoid and callus as static parameters and measured bone volume and mineral apposition rate as dynamic parameters. We observed the expressions of RANKL and OPG mRNA of the tibial bone by RT-PCR. Results : The body weight was significantly (p<0.05) increased in control and sample groups compared with sham group, respectively. The uterus weight was significantly (p<0.05) decreased in control and sample group compared with sham group. In the change of Ca, phosphorus and ALP there were no significant changes among three groups. There were no significant changes of trabecula cortical and osteoid bones' thickness and volume. But trabecula mineral apposition rate (MAR) was significantly (p<0.05) increased in sham and sample group compared with control group. In the expression of RANKL mRNA, sample group was decreased compared with control group, and in that of OPG mRNA, sample group was increased compared with control group. Conclusion : This study shows that Eucommiae Cortex has the beneficial effects on bone histomorphometry and metabolism in the ovariectomized rats. We suggest that Eucommiae Cortex be useful for the treatment of osteoporosis.

  • PDF

FMD response cow hooves and temperature detection algorithm using a thermal imaging camera (열화상 카메라를 이용한 구제역 대응 소 발굽 온도 검출 알고리즘 개발)

  • Yu, Chan-Ju;Kim, Jeong-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.292-301
    • /
    • 2016
  • Because damages arising from the occurrence of foot-and-mouth disease (FMD) are very great, it is essential to make a preemptive diagnosis to cope with it in order to minimize those damages. The main symptoms of foot-and-mouth disease are body temperature increase, loss of appetite, formation of blisters in the mouth, on hooves and breasts, etc. in a cow or a bull, among which the body temperature check is the easiest and quickest way to detect the disease. In this paper, an algorithm to detect FMD from the hooves of cattle was developed and implemented for preemptive coping with foot-and-mouth disease, and a hoof check test is conducted after the installation of a high-resolution camera module, a thermo-graphic camera, and a temperature/humidity module in the cattle shed. Through the algorithm and system developed in this study, it is possible to cope with an early-stage situation in which cattle are suspected as suffering from foot-and-mouth disease, creating an optimized growth environment for cattle. In particular, in this study, the system to cope with FMD does not use a portable thermo-graphic camera, but a fixed camera attached to the cattle shed. It does not need additional personnel, has a function to measure the temperature of cattle hooves automatically through an image algorithm, and includes an automated alarm for a smart phone. This system enables the prediction of a possible occurrence of foot-and-mouth disease on a real-time basis, and also enables initial-stage disinfection to be performed to cope with the disease without needing extra personnel.

Clinical Analysis of the Prognosis of the Patients with Cerebral Diffuse Axonal Injuries, Based on Gradient-echo MR Imaging (경사에코자기공명영상을 이용한 뇌미만성 축삭 손상 환자의 예후 분석)

  • Kim, Hyoung Jong;Park, In Sung;Kim, Jae Hyoung;Kim, Ki Jeong;Hwang, Soo Hyun;Kim, Eun-Sang;Jung, Jin-Myung;Han, Jong Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.168-172
    • /
    • 2001
  • Objective : The authors have studied the clinical outcome of patients with diffuse axonal injuries(DAI) to evaluate the prognostic value of gradient-echo MR imaging findings. Materials and Methods : From March 1995 to March 1998, there were nineteen patients with DAI whose initial Glasgow coma scales were eight or less. Authors divided them into two groups according to Glasgow outcome scales ; those patients with GOS 3 or less(group A ; 9) and those with 4 or more(group B ; 10). We subdivided the lesions as superficial and deep lesion, and analyzed the numbers, anatomical loci of the lesions on the gradient echo images of each group. Results : Mean numbers of the lesions were 15 per case in group A(135/9) and 10 in group B(100/10). The common loci involved in DAI were cerebral cortex, brain stem, and corpus callosum. Cortical lesions were 31.1% in group A(42/135) and 47% in group B(47/100). Brain stem lesions were 25.9%(35/135) and 15%(15/100) each. Callosal lesions were 31.1%(26/135) and 13%(13/100) each. The frequency of callosal and brain stem lesions was significantly different between two groups(p<0.05). We divided callosal lesions as genu, body, and splenium and body lesions as anterior, middle, posterior, but no significant topographical difference of lesions was observed between two groups. Deep lesions were observed more frequently in group A(58.5%, 79/135) than group B(36%, 36/100). Conclusion : The poor outcome group showed more numbers of lesion and more frequent involvement of brain stem and corpus callosum than favorable outcome group. Gradient-echo MR imaging seems to have predictive value for clinical outcome in patients with DAI.

  • PDF

A Study on School Uniform Modification According to Lifestyle in High School Girls (여고생의 라이프스타일에 따른 교복변형행동 비교)

  • Wee, Eun-Hah
    • Journal of Korean Home Economics Education Association
    • /
    • v.20 no.3
    • /
    • pp.201-213
    • /
    • 2008
  • This study was intended to examine the relationship between lifestyle and school uniform design modification in high school girls and provide basic data for guidance in the wearing of school uniform. The subjects of this study were 585 girls who were in the first and second grades of high schools throughout Gwangju. This study was executed using a questionnaire. The data from this study was processed using SPSS WIN 12.0(Kr). The results were as follows; This study hypothesized that the perception and attitude on school uniform modification would be significantly difference depending on lifestyles in high school girls. The significant differences appeared in a few items. So the results suggested that school uniform modification was a common that appeared in most high school girls. However it was affected by their lifestyle. specifically, a digital-dependence lifestyle group has a few different perceptions and attitudes on school uniform modification than the others. In other words, school uniform modification in high school girls who spend their most time in school is a general and universal clothing behavior by psychological factors rather than the effect of lifestyle. It is considered that rules concerning school uniform modification should allow students to express their individuality within certain limits. Teachers should instruct students to wear appropriate underwear rather than keep students under control with a fixed set of rules. If High school girls have a negative body image as a result of their exposed body, they should receive active educational guidance.

  • PDF

Discovery of the Dmitri Donskoi ship near Ulleung Island(East Sea of Korea), using geophysical surveys (물리탐사기술을 이용한 침몰선 Dmitri Donskoi호 탐사)

  • Yoo, Hai-Soo;Kim, Su-Jeong;Park, Dong-Won
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.104-111
    • /
    • 2005
  • Dmitri Donskoi, the Russian cruiser launched in 1883, is known to have sunk near Ulleung Island (East Sea, Korea) on May 29, 1905, while it was participating in the Russo-Japanese War. In order to find this ship, information about its possible location was obtained from Russian and Japanese maritime historical records. The supposed location of the ship was identified, and we conducted a five-year geophysical survey from 1999 to 2003. A reconnaissance three-dimensional topographic survey of the sea floor was carried out using multi-beam echo sounder, marine magnetometer, and side-scan sonar. An anomalous body identified through the initial reconnaissance survey was identified by a detailed survey using a remotely operated vehicle, deep-sea camera, and the mini-submarine Pathfinder. Interpretation of the acquired data showed that the ship is hanging on the side of a channel, at the bottom of the sea 400 m below sea level. The location is about 2 km from Port Jeodong, Uleung Island. We discovered 152 mm naval guns and other war materiel still attached to the hull of the ship. In addition, the remnants of the steering gear and other machinery that were burnt during the final action were found near the hull. Strong magnetic fields, resulting from the presence of volcanic rocks in the survey area, affected the resolution of the magnetic data gathered; as a result, we could not locate the ship reliably using the magnetic method. Severe sea floor topography in the gully around the hull gave rise to diffuse reflections in the side-scan sonar data, and this prevented us from identifying the anomalous body with the side-scan sonar technique. However, the sea-floor image obtained from the multi-bean echo sounder was very useful in verifying the location of the ship.

Contrast Optimization using of Weight-based Injection Protocol in Pediatric Abdomen CT Examination (소아 복부 CT 검사에서 체중에 기반한 조영제 주입 프로토콜 적용에 따른 조영증강의 최적화)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.575-584
    • /
    • 2021
  • The aim of this study was to achieve optimal portal phase while reducing contrast medium by applying weight-based dose protocol compared to standard fixed dose protocol to performing of pediatric abdominal CT examination. Discovery 750HD (General Electric Medical Systems, Milwaukee, USA) was used, and a total of 167 children consisting of 85 men and 82 women under the age of 18 were studied. The group in which the 300 mgI/ml(Xenetix, Guerbet, France) contrast medium was fixedly injected at twice body weight and the group injected with physiological saline while gradually decreasing the injection amount by 10% while applying the weight-based protocol were distinguished. Also, the CT number and SNR of abdominal organs were compared and evaluated while changing the scan delay time. Subjective image quality of enhancement and beam-hardening artifacts of around the heart was assessed with five-point criterion. The group adapted weight-based protocol with 20% reduction in contrast medium was most similar in contrast enhancement in the group with fixed injection at twice body weight. Furthermore, the group with a delay time of 20% had the highest contrast enhancement effect, and the difference in CT attenuation coefficient from the group scanned immediately after injection of the contrast media. Therefore, the appropriate delay time after injection of the contrast agent increased the contrast enhancement of the parenchymal organ. In addition, the weight-based injection protocol with normal saline reduced artifacts around the heart, and the effect of contrast enhancement could be maintained. In conclusion, it is possible to reduce dosage of contrast media through the application of weight-based injection protocols and appropriate latency, and to characterize optimal portal phase imaging on pediatric abdominal CT.

A Study on the Vibration Characteristics of Attitude Maneuvering of Satellite (위성의 자세기동에 따른 진동특성에 관한 연구)

  • Pyeon, Bong-Do;Bae, Jae-Sung;Kim, Jong-Hyuk;Park, Jung-Sun
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.3
    • /
    • pp.23-31
    • /
    • 2019
  • The design requirements of modern satellites vary depending on the purpose of operation. Like conventional medium and large-scale satellites, small satellites which operate on low orbit may also serve military purposes. As a result, there is increased demand for high-resolution photos and videos and multi-target observation becomes important. The most important design parameter for multi-target observation is the satellites' maneuverability. For increased maneuverability, the miniaturization is required to increase the stiffness of the satellite as this decreases the mass moment of inertia of the satellite. In the case of a solar panel having relatively low stiffness compared to the satellites' body, vibrations are generated when the attitude maneuver is performed, which greatly influences the image acquisition. For verification of such vibrational characteristics, the satellites is modeled as a reduced model, and experimental zig for simulating attitude maneuver is introduced. A rigidity simulator for simulating the stiffness of the satellite is also proposed. Additionally, the objective of the experimental method is to simulate the maneuvering angle of the satellite based on the winding length of the wire using a step motor, and to experimentally verify the vibration characteristics of the satellite body and the solar panel generated during the maneuvering test.

Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT' (고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가)

  • Kim, Jaeil;Lim, Jeongjin;Cho, Seongwook;Noh, Kyeongwoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.54-58
    • /
    • 2019
  • Purpose At now, there are many kind of dedicated heart SPECT machine in clinical nuclear medicine. Among those, the fixed focusing type SPECT can make a good quality, quantity image because a detectors of this SPECT arranged forward a special ROI and didn't rotate around of body. So, in this paper, we will evaluate a spatial uniformity about resolution and sensitivity at a same plane of a fixed focusing type SPECT. Materials and Methods We used D-SPECT as a fixed focusing type SPECT and Cario MD as a rotated parallel type SPECT to comparing each other. We injected $^{99m}Tc(14.8MBq/1cc)$ to 10 capillary tube (diameter=1mm), and we set those line sources a tfield of view of each SPECT. And then we acquired SPECT date, we applied are construction by recommended methods. By using two tomography images, we calculated a full width of half maximum as a resolution and total counts as a sensitivity, and we compared a CV (coefficientofvariation) values between two images as a spatial uniformity. Results In case of D-SPECT, a CV of resolution and sensitivity are 7.45%, 12.34%. In case of Cario MD, an CV of resolution and sensitivity are 12.49%, 21.84% Conclusion As a results, CV of resolution and sensitivity of a fixed focusing type SPECT is 67.75%, 77.00% higher than ones of a rotated parallel type SPECT. It means that a fixed focusing type SPECT is more uniformed, because this new SPECT can reduce a motion blur artifact by rotating detector around body, also all of detector that made by semiconductor arrange forward a special FOV like heart.

FBX Format Animation Generation System Combined with Joint Estimation Network using RGB Images (RGB 이미지를 이용한 관절 추정 네트워크와 결합된 FBX 형식 애니메이션 생성 시스템)

  • Lee, Yujin;Kim, Sangjoon;Park, Gooman
    • Journal of Broadcast Engineering
    • /
    • v.26 no.5
    • /
    • pp.519-532
    • /
    • 2021
  • Recently, in various fields such as games, movies, and animation, content that uses motion capture to build body models and create characters to express in 3D space is increasing. Studies are underway to generate animations using RGB-D cameras to compensate for problems such as the cost of cinematography in how to place joints by attaching markers, but the problem of pose estimation accuracy or equipment cost still exists. Therefore, in this paper, we propose a system that inputs RGB images into a joint estimation network and converts the results into 3D data to create FBX format animations in order to reduce the equipment cost required for animation creation and increase joint estimation accuracy. First, the two-dimensional joint is estimated for the RGB image, and the three-dimensional coordinates of the joint are estimated using this value. The result is converted to a quaternion, rotated, and an animation in FBX format is created. To measure the accuracy of the proposed method, the system operation was verified by comparing the error between the animation generated based on the 3D position of the marker by attaching a marker to the body and the animation generated by the proposed system.

Evaluation of Scattered Rays of Jelly Type Shielding Body by L-spine AP using X-ray (L-Spine X-선 촬영에서의 Jelly type 차폐체의 산란선 차폐평가)

  • Jang, Hui-Min;Kim, Do-Gwon;Kim, Hyeong-Bin;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.907-913
    • /
    • 2020
  • There have been continuous controversies on medical X-ray protection and numerous researchers have been trying to prevent unnecessary exposure to radiation. As X-ray passes through the patient and obtains an image, it creates scattered ray due to interactions such as photoelectric effect and Compton scattering with the subject. As a result, both medical radiation staff and patient are exposed to unnecessary radiation on areas other than the target area. In response, this study will be assuming a body of a female, radiating X-ray on the phantom under the conditions of lumbar spine AP test, and measuring scattered ray around breasts and thyroid glands. Then, The experiment results were as follows. After application of non-shielding material, the average of scattered ray was 0.88 mR in thyroid measurement, 3.34 mR, Lt Axillary 3.54 mR, and Rt Axillary 3.03 mR in mamonary measurement but, After application of shielding material, the average of scattered ray was 0.16 mR in thyroid measurement, 0.60 mR, Lt Axillary 0.64 mR, and Rt Axillary 0.54 mR in mamonary measurement showing average scattered ray protection effect of about 82%. This study suggested the manufacturing method of a Jelly-type shielding material, identified the possibilities of researches on mixing various substances with radiology field, and verified the usability of the Jelly-type shielding material as a substitute for existing protection tools.