• Title/Summary/Keyword: body camera

Search Result 424, Processing Time 0.023 seconds

Influence of Iodinated Contrast Media and Paramagnetic Contrast Media on Changes in Uptake Counts of 99mTc

  • Cho, Jae-Hwan;Lee, Jin-Hyeok;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Jin;Moon, Deog-Hwan;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

Characteristics of Remote Sensors on KOMPSAT-I (다목적 실용위성 1호 탑재 센서의 특성)

  • 조영민;백홍렬
    • Korean Journal of Remote Sensing
    • /
    • v.12 no.1
    • /
    • pp.1-16
    • /
    • 1996
  • Korea Aerospace Research Institute(KARI) is developing a Korea Multi-Purpose Satellite I(KOMPSAT-I) which accommodates Electro-Optical Camera(EOC), Ocean Color Imager(OCI), Space Physics Sensor(SPS) for cartography, ocean color monitoring, and space environment monitoring respectively. The satellite has the weight of about 500 kg and is operated on the sun synchronized orbit with the altitude of 685km, the orbit period of 98 minutes, and the orbit revisit time of 28days. The satellite will be launched in the third quarter of 1999 and its lifetime is more than 3 years. EOC has cartography mission to provide images for the production of scale maps, including digital elevation models, of Korea from a remote earth view in the KOMPSAT orbit. EOC collects panchromatic imagery with the ground sample distance(GSD) of 6.6m and the swath width of 15km at nadir through the visible spectral band of 510-730 nm. EOC scans the ground track of 800km per orbit by push-broom and body pointed method. OCI mission is worldwide ocean color monitoring for the study of biological oceanography. OCI is a multispectral imager generating 6 color ocean images with and <1km GSD by whisk-broom scanning method. OCI is designed to provide on-orbit spectral band selectability in the spectral range from 400nm to 900nm. The color images are collected through 6 primary spectral bands centered at 443, 490, 510, 555, 670, 865nm or 6 spectral bands selected in the spectral range via ground commands after launch. SPS consists of High Energy Particle Detector(HEPD) and Ionosphere Measurement Sensor(IMS). HEPD has mission to characterize the low altitude high energy particle environment and to study the effects of radiation environment on microelectronics. IMS measures densities and temperature of electrons in the ionosphere and monitors the ionospheric irregularities in KOMPSAT orbit.

Analysis of movement in (2013) (<셜리에 관한 모든 것>(2013)에 나타난 움직임 분석)

  • Moon, Jae-Cheol;Lee, Jin-Young
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.6
    • /
    • pp.43-52
    • /
    • 2020
  • This paper is a study of Gustav Deutsch's film (2013). The film transformed the painting of Edward Hopper into an homage film. So it gives the impression that the picture is moving. In this regard, it raises the issue of 'remediation' between film and pictures. In this study, We ask how (2013) dealt with the movement in turning Hopper's paintings into movies. To that end, To this end, we look at two aspects of movement: the actor's movement and the screen's movement. The concepts of "tableau vivant," Agamben's gesture and mediation were used in the process. The actor's movement in the film is not an act of making and developing events. It is a gesture that moves a person's body and expression itself. It is not a story-oriented acting, but a gesture that Giorgio Agamben said. Editing and camera movements are used while maintaining frontality. This suggests that the movement of the screen is the eye of the audience. At first glance, it embodies the voyeuristic gaze of the original work. However, But the audience isn't looking at the image unilaterally, as in mainstream fiction films, but they are also being seen by that image. Also, the camera's movement to take a closer look at the details of the screen shows the movement itself rather than the means to reveal the details. The 'vision of reality' in a film is made through movement. The film questions the vision of reality between painting and film, between words and images. The move is a means of mediating reality, but the film is regaining the "lost gesture" that Giorgio Agamben once said by revealing its mediated nature. This tells us that the vision of reality appears when it obscures its mediated nature.

A Study on the Measurement of Respiratory Rate Using Image Alignment and Statistical Pattern Classification (영상 정합 및 통계학적 패턴 분류를 이용한 호흡률 측정에 관한 연구)

  • Moon, Sujin;Lee, Eui Chul
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.10
    • /
    • pp.63-70
    • /
    • 2018
  • Biomedical signal measurement technology using images has been developed, and researches on respiration signal measurement technology for maintaining life have been continuously carried out. The existing technology measured respiratory signals through a thermal imaging camera that measures heat emitted from a person's body. In addition, research was conducted to measure respiration rate by analyzing human chest movement in real time. However, the image processing using the infrared thermal image may be difficult to detect the respiratory organ due to the external environmental factors (temperature change, noise, etc.), and thus the accuracy of the measurement of the respiration rate is low.In this study, the images were acquired using visible light and infrared thermal camera to enhance the area of the respiratory tract. Then, based on the two images, features of the respiratory tract region are extracted through processes such as face recognition and image matching. The pattern of the respiratory signal is classified through the k-nearest neighbor classifier, which is one of the statistical classification methods. The respiration rate was calculated according to the characteristics of the classified patterns and the possibility of breathing rate measurement was verified by analyzing the measured respiration rate with the actual respiration rate.

The Effect of Exercise Program for Prevention of Falling on Physical Fitness, Posture and Fall Prevention Self-Efficacy for Elderly Women (넘어짐 예방 운동이 여성노인의 체력, 자세, 낙상효능감에 미치는 영향)

  • Son, Nam Jeong;Yi, Kyung Ock;An, Ju Yeun
    • 한국노년학
    • /
    • v.37 no.1
    • /
    • pp.237-250
    • /
    • 2017
  • The purpose of this study is to analyze the effects of exercise program for prevention of falling on physical fitness, posture and fall prevention self-efficacy for elderly women. 30 females above the age of 65 were subjects for this study. Over an twelve week period, 14women in the experimental group performed exercise 2 times a week for 60 minutes per session. 16women in the control group didn't participate in the exercise program. The independent variable was a exercise program for prevention of falling. Dependent variables were physical fitness, posture and fall prevention self-efficacy. Prevention of falling exercise program is consisted of an elastic band using exercise and Korean dance movement exercise. Physical fitness consisted of grip strength, upper and lower body endurance, cardiovascular endurance, flexibility, balance, coordination. The posture was measured the static posture when standing, using a high-resolution camera, body style to automatically measure the distance and angle(M-zen, Korea). Posture was measured in both the coronal and sagittal plane via reference board. Fall prevention self-efficacy was measured via questionnaire using the Korea Falls Self-Efficacy Scale (FES-K). The physical fitness, posture and fall prevention self-efficacy were measured twice with pre and post exercise, and the difference between groups with Wilcox signed rank test, and the group-specific post verification was carried out with U-validated methods (Mann Whitney U test). Statistical significance level was verified by setting the p<.05. Lower body endurance, cardiovascular endurance, flexibility, balance and coordination significantly increased in the experimental group. The control group was no significant increase in physical fitness variables. shoulder slope angle, pelvic slope angle(coronal/sagittal), leg length difference, scapular inferior angle and left/right calcaneus angle significantly decreased in the experimental group. Both the experimental group and control group were no significant increase in fall prevention self efficacy. The prevention of falling exercise program for elderly women indicated the positive changes in physical fitness(except grip strength) and posture(except upper body slope). However, there are no significant differences of falling prevention self-efficacy between the both group. Thus, the prevention of falling exercise program for the elderly has been proved that it is highly efficient on improving physical fitness and posture proofreading. However, we still need to consider supplement exercise for grip strength and upper body slope.

The Biometric Authentication Scheme Capable of Multilevel Security Control (보안레벨 조절이 가능한 바이오메트릭 인증 기법)

  • Yun, Sunghyun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.2
    • /
    • pp.9-14
    • /
    • 2017
  • A fingerprint is unique to each person and can be represented as a digital form. As the fingerprint is the part of human body, fingerprint recognition is much more easy to use and secure rather than using password or resident card for user authentication. In addition, as the newly released smart phones have built-in camera and fingerprint sensors, the demand for biometric authentication is increasing rapidly. But, the drawback is that the fingerprint can be counterfeited easily and if it's exposed to the hacker, it cannot be reused. Thus, the original fingerprint template should be transformed for registration and authentication purposes. Existing transformation functions use passcode to transform the original template to the cancelable form. Additional module is needed to input the passcode, so it requires more cost and lowers the usability. In this paper, we propose biometric authentication scheme that is economic and easy to use. The proposed scheme is consisted of cancelable biometric template creation, registration and user authentication protocols, and can control several security levels by configuring the number of fingerprints and scan times. We also analyzed that our scheme is secure against the brute-force attack and the active attacks.

The Biomechanical Analysis of a One-Legged Jump in Traditional Korean Dance According to Breathing Method (호흡 방법에 따른 한국무용 외발뛰기 동작의 운동역학적 분석)

  • An, Ju-Yeun;Yi, Kyung-Ock
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.199-206
    • /
    • 2015
  • Objective : The purpose of this study was to conduct a biomechanical analysis of a one-legged jump in a traditional Korean dance (Wae Bal Ddwigi) according to breathing method. Method : Participants for this study were 10 dancers with experience for at least 10 years in traditional Korean dance. Independent variables for this test were two different types of breathing methods. Dependent variables were ground reaction force and lower extremity kinematic variables. The jumping movement was divided into three separate stages, take off, flight, and landing. The subjects were asked a questionnaire regarding the degree of impact force and stability of landing posture after the experiment. The Kistler Force Plate (9281B, Switzerland) was used to measure ground reaction force. A digital camera was used to look into angles of each joint of the lower part of body. SPSS was used for statistical analysis via the dependent t-test(p<.05). Results : There were significant differences in jumping according to breathing method. The inhalation & exhalation method yielded significantly longer flight times combined with greater ground reaction force. The breath-holding method required more core flexion during landing, increasing movement at the hips and shoulders. Conclusion : Consequently, there was more flexion at the knee to compensate for this movement. As a result, landing time was significantly higher for breath-holding.

Kinematical Analysis of the Back Somersault in Floor Exercise (마루운동 제자리 뒤공중돌기 동작의 운동학적 분석)

  • Chung, Nam-Ju
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.157-166
    • /
    • 2007
  • This study was to compare the major kinematic factors between the success and failure group on performing the back somersault motion in floor exercise. Three gymnasts(height : $167.3{\pm}2.88cm$, age : $22.0{\pm}1.0years$, body weight : $64.4{\pm}2.3kg$) were participated in this study. The kinematic data was recorded at 60Hz with four digital video camera. Two successful motions and failure motions for each subject were selected for three dimensional analysis. 1. Success Trail It was appear that success trail was larger than failure group in projection velocity, but success trail was smaller than failure trail in projection angle. Also it was appear that success trail was longer than failure group in the time required. Hand segment velocity and maximum velocity in success trail were larger than those in failure trail, and this result was increasing the projection velocity and finally increasing the vertical height of center of mass. At the take-off(event 2), flection amount of hip and knee joint angle was contributed to the optimal condition for the take-off and at the peak point, hip and knee joint angle was maximum flexed for reducing the moment of inertia. Also in this point, upper extremities of success trail extended more than those of failure trail. in this base, success trail in upward phase(p3) 2. Failure Trail It was appear that failure trail was smaller than success trail in projection velocity, but failure trail was larger than success trail in projection angle. Also it was appear that failure trail was more short than success trail in the time required. Hand segment velocity and maximum velocity in failure trail were smaller than those in success trail, and this result was reducing the projection velocity and finally reducing the vertical high of center of mass. At the take-off(event 2), flection amount of hip and knee joint angle wasn't contributed to the optimal condition for the take-off and at the peak point, hip and knee joint angle wasn't maximum flexed for reducing the moment of inertia. Also in this point, upper extremities of failure trail didn't extended more than those of success trail.

Virtual Angioscopy for Diagnosis of Carotid Artery Stenosis (경동맥 협착증 진단을 위한 가상혈관경)

  • 김도연;박종원
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.9
    • /
    • pp.821-828
    • /
    • 2003
  • The virtual angioscopy was implemented using MR angiography image of carotid artery Inside of the carotid artery is one of the body region not accessible by real optical endoscopy but can be visualized with virtual endoscopy. In order to determine the navigation path, we segmented the common carotid artery and internal carotid artery from the MR angiography image. We used the coordinates as a navigation path for virtual camera that were calculated from medial axis transformation. We used the perspective projection and marching cube algorithm to render the surface from volumetric MRA image data. A stroke occurs when brain cells die because of decreased blood flow to the brain. The carotid artery is the primary blood vessel that supplies the blood flow to the brain. Therefore, the carotid artery stenosis is the primary reason of stroke. The virtual angioscopy is highly recommended as a diagnosis tool with which the specific Place of stenosis can be identified and the degree of stenosis can be measured qualitatively. Also, the virtual angioscopy can be used as an education and training tool for endoscopist and radiologist.

A Pressure Applied Low-Level Laser Probe to Enhance Laser Photon Density in Soft Tissue (생체조직내 레이저 광 밀도 향상을 위한 압력 인가형 저출력 레이저 프로브)

  • Yeo, Chang-Min;Park, Jung-Hwan;Son, Tae-Yoon;Lee, Yong-Heum;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • Laser has been widely used in various fields of medicine. Recently, noninvasive low-level laser therapeutic medical devices have been introduced in market. However, low-level laser cannot deliver enough photon density to expect positive therapeutic results in deep tissue layer due to the light scattering property in tissue. In order to overcome the limitation, this study was aimed to develop a negative pressure applied low-level laser probe to optimize laser transmission pattern and therefore, to improve photon density in soft tissue. In order to evaluate the possibility of clinical application of the developed laser probe, ex-vivo experiments were performed with porcine skin samples and laser transmissions were quantitatively measured as a function of tissue compression. The laser probe has an air suction hole to apply negative pressure to skin, a transparent plastic body to observe variations of tissue, and a small metallic optical fiber guide to support the optical fiber when negative pressure was applied. By applying negative pressure to the laser probe, the porcine skin under the metallic optical fiber guide is compressed down and, at the same time, low-level laser is emitted into the skin. Finally, the diffusion images of laser in the sample were acquired by a CCD camera and analyzed. Compared to the peak intensity without the compression, the peak intensity of laser increased about $2{\sim}2.5$ times and FWHM decreased about $1.67{\sim}2.85$ times. In addition, the laser peak intensity was positively and linearly increased as a function of compression. In conclusion, we verified that the developed low-level laser probe can control the photon density in tissue by applying compression, and therefore, its potential for clinical applications.