• Title/Summary/Keyword: blood velocity

Search Result 393, Processing Time 0.02 seconds

Microfluidic Device for Ultrasound Image Analysis based on 3D Printing (초음파 영상 분석을 위한 3D 프린팅 기반 미세유체소자)

  • Kang, Dongkuk;Hong, Hyeonji;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.1
    • /
    • pp.15-20
    • /
    • 2018
  • For the measurement of biophysical properties related with cardiovascular diseases (CVD), various microfluidic devices were proposed. However, many devices were monitored by optical equipment. Ultrasound measurement to quantify the biophysical properties can provide new insights to understand the cardiovascular diseases. This study aims to check feasibility of microfluidic device for ultrasound image analysis based on 3D printer. To facilitate acoustic transmission, agarose solution is poured around 3D mold connected with holes of the acrylic box. By applying speckle image velocimetry(SIV) technique, flow information in the bifurcated channel was estimated. Considering that ultrasound signal amplitude is determined by red blood cell (RBC) aggregation, RBC aggregation in the bifurcated channel can be estimated through the analysis of ultrasound signal. As examples of microfluidic device which mimic the CVD model, velocity fields in microfluidic devices with stenosis and aneurysm were introduced.

Comparison of Simultaneously Measured Pulse Waveforms from Both Hands using Permanent Magnet-Hall Pulsimeter Sensor (영구자석-홀 맥진센서를 이용한 양손 동시측정 맥진파형 비교 연구)

  • Yoo, Gi-Doo;Hwang, Sung-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.1
    • /
    • pp.27-31
    • /
    • 2012
  • Two radially arterial pulses of both hands using the prototype of a clamping clip pulsimeter equipped with permanent magnet and Hall device are compared and analyzed. The phase difference of two pulse wave signals is dominantly presented from the simultaneous measuring clinical pulse wave signals for twenty two male participants at their 20's. It is possible to analyze that the fast and slow pulse wave for right hand and left hand depend on the muscle property of arms rather than the total length of blood vessel due to cardiovascular circulatory system.

Rh2-enriched Korean Ginseng Ameliorates Chronic Fatigue in a Forced Exercise mouse model

  • Kim, Won-Yong;Lee, Jin-Seok;Yoo, Hwa-Seung;Son, Chang-Gue
    • The Journal of Korean Medicine
    • /
    • v.37 no.2
    • /
    • pp.76-84
    • /
    • 2016
  • Objectives: We evaluated the anti-fatigue effects of Rh2-enriched Korean ginseng (Ginseng Rh2+) using a forced exercise-induced chronic fatigue mouse model. Methods: ICR male mice were subjected to running wheel for 1 h, 5 days/week during 4 weeks, and running velocity was gradually increased. Each running session was followed by oral administration of distilled water, Ginseng Rh2+ (150 or 300 mg/kg), or N-acetyl-L-cysteine (NAC, 100 mg/kg) 1 h later. The exercise tolerance and forced swimming test were performed to evaluate the fatigue condition. Results: Chronic forced exercise reduced the physical activity, as evidenced by the behavioral tests, which were notably ameliorated by Ginseng Rh2+ treatment. Ginseng Rh2+ treatment also attenuated the alterations of energy metabolism and oxidative stress in skeletal muscle tissues and/or sera, including malondialdehyde (MDA), lactate concentration and its related factors (lactate dehydrogenase, blood urea nitrogen, and glucose levels). Conclusion: These findings strongly suggest that Ginseng Rh2+ exerts a potent anti-fatigue effect through modulation of energy metabolism and oxidative response.

A Study on A New Two-Dimensional Pulsed Doppler System Using Second-Order Sampling Method. (2차 샘플링을 이용한 새로운 초음파 2차원 펄스 도플러 시스템에 관한 연구)

  • Park, Se-Hyeon;Im, Chun-Seong;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.33-42
    • /
    • 1989
  • The doppler effect is used for measuring the velocity of the blood flow in artery. Because of the range information, the pulsed doppler system is most commonly used. In this paper, we propose a new two-dimensional(2-D) pulsed Doppler system. Which uses second-order sampling method and serial processing. The proposed system using second-order sampling method eliminates in-phase, quadrature-phase balancing problem at demodulator of quadrature detection method. In addition, the new pulsed 2-D doppler system eliminates balancing problem of channels of 2-D doppler system because of serial processing.

  • PDF

Operating Characteristics of the Flow Control Valve for the Radiant Heating System (복사난방용 유량조절 밸브의 작동특성 연구)

  • Pyo, Jin-Soo;Jang, Choon-Soo;Choi, Kwang-Suk;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.552-557
    • /
    • 2007
  • Due to the recent improvement of living standard of residential buildings, the requirements of the thermal comfort and energy saving in heating system have been raised. The radiant floor heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. The uniform flow distribution is very important factor for a radiant floor heating system such as a blood vessel system in human body. Therefore, it is necessary to investigate the operating characteristics to develop an optimal radiant floor heating system. In this study, numerical analyses were carried out, using a commercial CFD code, FLUENT, to obtain the velocity distribution under steady, three-dimensional, standard k-$\varepsilon$ model and no-slip condition. Results are graphically depicted with various parameters.

  • PDF

Ultrasonic Targeting of NK Cell in Vessel Bifurcation for Immunotherapy: Simulation and Experimental Validation

  • Saqib Sharif;Hyeong-Woo Song;Daewon Jung;Hiep Xuan Cao;Jong-Oh Park;Byungjeon Kang;Eunpyo Choi
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.418-424
    • /
    • 2023
  • Natural killer (NK) cells play a crucial role in combating infections and tumors. However, their therapeutic application in solid tumors is hindered by challenges, such as limited lifespan, tumor penetration, and delivery precision. Our research introduces a novel ultrasonic actuation technique to navigate NK cells more effectively in the vascular system, particularly at vessel bifurcations where targeted delivery is most problematic. We use a hemispherical ultrasonic transducer array that generates phase-modulated traveling waves, focusing on an ultrasound beam to steer NK cells using blood-flow dynamics and a focused acoustic field. This method enables the precise obstruction of non-target vessels and efficiently directs NK cells toward the tumor site. The simulation results offer insights into the behavior of NK cells under various conditions of cell size, radiation pressure, and fluid velocity, which inform the optimization of their trajectories and increase targeting efficiency. The experimental results demonstrate the feasibility of this ultrasonic approach for enhancing NK cell targeting, suggesting a potential leap forward in solid tumor immunotherapy. This study represents a significant step in NK cell therapeutic strategies, offering a viable solution to the existing limitations and promising enhancement of the efficacy of cancer treatments.

How to Treat Peripheral Arteriovenous Malformations

  • Ran Kim;Young Soo Do;Kwang Bo Park
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.568-576
    • /
    • 2021
  • Arteriovenous malformations (AVMs) are direct communications between primitive reticular networks of dysplastic vessels that have failed to mature into capillary vessels. Based on angiographic findings, peripheral AVMs can be classified into six types: type I, type IIa, type IIb, type IIc, type IIIa, and type IIIb. Treatment strategies vary with the types. Type I is treated by embolizing the fistula between the artery and the vein with coils. Type II (IIa, IIb, and IIc) AVM is treated as follows: first, reduce the blood flow velocity in the venous segment of the AVM with coils; second, perform ethanol embolotherapy of the residual shunts. Type IIIa is treated by transarterial catheterization of the feeding arteries and injection of diluted ethanol. Type IIIb is treated by transarterial or direct puncture approaches. A high concentration of ethanol is injected through the transarterial catheter or direct puncture needle. When the fistula is large, coil insertion is required to reduce the amount of ethanol. Type I and type II AVMs showed the best clinical results; type IIIb showed a satisfactory response rate. However, type IIIa showed the poorest response rate, either alone or in combination with other types. Clinical success can be achieved by using different treatment strategies for different angiographic AVM types.

Pulse wave velocity and ankle brachial index in obese adolescents (비만 청소년에서 맥파 속도와 발목 상완 동맥압 지수에 대한 연구)

  • Kim, Ji Hye;Koo, Hee Sun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.11
    • /
    • pp.1078-1084
    • /
    • 2007
  • Purpose : The prevalence of childhood obesity has doubled over the last 30 years. Obesity-associated sequelae in the vasculature begins in the early stages of life. The purpose of this study was to investigate how pulse wave velocity (PWV) and ankle brachial index (ABI) change with height, weight and body mass index (BMI) in obese adolescents. Methods : Seventy-nine obese adolescents (group 1: $85th{\leq}BMI<95th$ percentile, n=40; group 2 ($BMI{\geq}95th$ percentile, n=39) were included. The control group(group 3) included 99 healthy adolescents. Brachial- ankle (ba) PWV and ABI were estimated with blood pressure from four extremities. Heart rate (HR), and pre-ejection period/ejection time (PEP/ET) were also estimated. BMI was calculated from individual height and weight. Linear regression analysis was performed to evaluate the correlations between BMI and PWV. Results : Blood pressure and baPWV were significantly higher in group 2, compared to either group 1 or group 3. However, there was no significant difference in ABI, HR and PEP/ET between the groups. PWV showed linear correlation with both BMI and body weight. Conclusion : Obesity was associated with higher arterial stiffness in adolescents, which was demonstrated by an increase in PWV. There was no significant correlation between obesity and ABI.

Development and Feasibility Study for Phase Contrast MR Angiography at Low Tesla Open-MRI System (저자장 자기공명영상 시스템에서의 위상대조도 혈관조영기법의 개발과 그 유용성에 대한 연구)

  • Lee, Dong-Hoon;Hong, Cheol-Pyo;Lee, Man-Woo;Han, Bong-Soo
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.177-187
    • /
    • 2012
  • Magnetic resonance angiography (MRA) techniques are widely used in diagnosis of vascular disorders such as hemadostenosis and aneurism. Especially, phase contrast (PC) MRA technique, which is a typical non contrast-enhanced MRA technique, provides not only the anatomy of blood vessels but also flow velocity. In this study, we developed the 2- and 3-dimensional PC MRA pulse sequences for a low magnetic field MRI system. Vessel images were acquired using 2D and 3D PC MRA and the velocities of the blood flow were measured in the superior sagittal sinus, straight sinus and the confluence of the two. The 2D PC MRA provided the good quality of vascular images for large vessels but the poor quality for small ones. Although 3D PC MRA gave more improved visualization of small vessels than 2D PC MRA, the image quality was not enough to be used for diagnosis of the small vessels due to the low SNR and field homogeneity of the low field MRI system. The measured blood velocities were $25.46{\pm}0.73cm/sec$, $24.02{\pm}0.34cm/sec$ and $26.15{\pm}1.50cm/sec$ in the superior sagittal sinus, straight sinus and the confluence of the two, respectively, which showed good agreement with the previous experimental values. Thus, the developed PC MRA technique for low field MRI system is expected to provide the useful velocity information to diagnose the large brain vessels.

Clinical Applications of Neuroimaging with Susceptibility Weighted Imaging: Review Article (SWI의 신경영상분야의 임상적 이용)

  • Roh, Keuntak;Kang, Hyunkoo;Kim, Injoong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.290-302
    • /
    • 2014
  • Purpose : Susceptibility-weighted magnetic resonance (MR) sequence is three-dimensional (3D), spoiled gradient-echo pulse sequences that provide a high sensitivity for the detection of blood degradation products, calcifications, and iron deposits. This pictorial review is aimed at illustrating and discussing its main clinical applications. Materials and Methods: SWI is based on high-resolution, 3D, fully velocity-compensated gradient-echo sequences using both magnitude and phase images. To enhance the visibility of the venous structures, the magnitude images are multiplied with a phase mask generated from the filtered phase data, which are displayed at best after post-processing of the 3D dataset with the minimal intensity projection algorithm. A total of 200 patients underwent MR examinations that included SWI on a 3 tesla MR imager were enrolled. Results: SWI is very useful in detecting multiple brain disorders. Among the 200 patients, 80 showed developmental venous anomaly, 22 showed cavernous malformation, 12 showed calcifications in various conditions, 21 showed cerebrovascular accident with susceptibility vessel sign or microbleeds, 52 showed brain tumors, 2 showed diffuse axonal injury, 3 showed arteriovenous malformation, 5 showed dural arteriovenous fistula, 1 showed moyamoya disease, and 2 showed Parkinson's disease. Conclusion: SWI is useful in detecting occult low flow vascular lesions, calcification and microbleed and characterising diverse brain disorders.