DOI QR코드

DOI QR Code

Comparison of Simultaneously Measured Pulse Waveforms from Both Hands using Permanent Magnet-Hall Pulsimeter Sensor

영구자석-홀 맥진센서를 이용한 양손 동시측정 맥진파형 비교 연구

  • Yoo, Gi-Doo (Department of Oriental Biomedical Engineering, Sangji University) ;
  • Hwang, Sung-Gi (Department of Oriental Biomedical Engineering, Sangji University) ;
  • Lee, Sang-Suk (Department of Oriental Biomedical Engineering, Sangji University)
  • 유기두 (상지대학교 보건과학대학 한방의료공학과) ;
  • 황성기 (상지대학교 보건과학대학 한방의료공학과) ;
  • 이상석 (상지대학교 보건과학대학 한방의료공학과)
  • Received : 2011.11.23
  • Accepted : 2012.02.02
  • Published : 2012.02.29

Abstract

Two radially arterial pulses of both hands using the prototype of a clamping clip pulsimeter equipped with permanent magnet and Hall device are compared and analyzed. The phase difference of two pulse wave signals is dominantly presented from the simultaneous measuring clinical pulse wave signals for twenty two male participants at their 20's. It is possible to analyze that the fast and slow pulse wave for right hand and left hand depend on the muscle property of arms rather than the total length of blood vessel due to cardiovascular circulatory system.

영구자석과 홀소자로 구비된 두 대의 집게형 맥진기 시제품을 이용하여 비가압 상태에서 양손 요골동맥의 맥진파형을 동시측정한 신호들을 비교 분석하였다. 20대 남성 피실험자 22명을 대상으로 측정된 오른손잡이와 왼손잡이의 두 맥진파형들은 위상차를 갖고 뚜렷하게 구별되었다. 서로 다른 빠름과 늦음으로 인해 두 개의 맥진파형들의 위상차 부호는 맥파전달속도가 오른손과 왼손 혈관의 총길이 보다는 자주 사용하는 팔의 근육 특성에 의존한다는 분석이 가능하였다.

Keywords

References

  1. S. S. Lee, M. C. Ahn, and S. H. Ahn, J. Magnetics. 14, 132 (2009). https://doi.org/10.4283/JMAG.2009.14.3.132
  2. M. F. P. O'Rourke, R. P. Kelly, and A. P. Avolio, 1st Ed., Lea & Febiger, Philadelphia (1992).
  3. S. W. Kim, Y, G, Choi, H. S. Lee, D. H. Park, D. G. Hwang, S. S. Lee, G. W. Kim, S. G. Lee, and S. J. Lee, J. Appl. Phys. 99, R908 (2006).
  4. S. D. Choi, S. W. Kim, G. W. Kim. M. C. Ahn, M. S. Kim, D. G. Hwang, and S. S. Lee, J. Magn. Magn. Mater. 310, e983 (2007). https://doi.org/10.1016/j.jmmm.2006.10.1027
  5. Q. Yu, J. Zhou, and Y. C. Fung, Am. J. Physiol. Heart Circ. Physiol. 265, 52 (1993).
  6. M. C. P. Carrasquero, L. M. H. Bemard, H. Kobori, Y. Ozawa, K. S. H. Smith, L. L. Hamm, and L. G. Navar, Hypertension 44, 223 (2004). https://doi.org/10.1161/01.HYP.0000135678.20725.54
  7. S. S. Lee, D. H. Nam, Y. S. Hong, W. B. Lee, I. H. Son, K. H. Kim, and J. G. Choi, Sensors 11, 1784 (2011). https://doi.org/10.3390/s110201784
  8. M. C. Ahn, J. G. Choi, I. H. Son, S. S. Lee, and K. H. Kim, J. Kor. Mag. Soc. 20, 106 (2010). https://doi.org/10.4283/JKMS.2010.20.3.106
  9. I. H. Son, K. H. Kim, J. G. Choi, D. H. Nam, and S. S. Lee, IEEE Trans. Magn. 47, 3063 (2011). https://doi.org/10.1109/TMAG.2011.2155044
  10. S. S. Lee, I. H. Son, J. G. Choi, D. H. Nam, Y. S. Hong, and W. B. Lee, J. Kor. Phys. Soc. 58, 349 (2011). https://doi.org/10.3938/jkps.58.349
  11. A. L. Kierzenhaum, Mosby Inc., St. Louis (2002).
  12. M. Soon, 3rd Ed., Chung-Ku Publishing Co., Korea (2002).
  13. S. H. Baek, Clinical Vascular Medicine, Korean Vascular Research Working Group (2009) pp. 109-124.
  14. H. Y. Park, S. Y. Lee, S. W. Cho, S. U. Kwon, J. Namgung, J. H. Do, and W. R. Lee, Korean Circulation J. 36, 393 (2006). https://doi.org/10.4070/kcj.2006.36.5.393

Cited by

  1. Analysis of Magnetic Field Variation for Pulse Wave by Using Finite Element Method vol.24, pp.3, 2014, https://doi.org/10.4283/JKMS.2014.24.3.090
  2. A Research of characteristics of left/right pulse wave and blood vessel using Korean medicine pulse diagnosis vol.35, pp.3, 2014, https://doi.org/10.13048/jkm.14038