• Title/Summary/Keyword: blood velocity

Search Result 393, Processing Time 0.031 seconds

Blood flow velocity measurement device using a pulse wave and ECG (맥파와 심전도를 이용한 혈류속도 측정장치)

  • Jeong, Jinhyung;Heo, Sun oh;Kim, Taegeun;Kim, Yunjeong;Lee, Kiyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.1
    • /
    • pp.57-64
    • /
    • 2013
  • 본 논문에서는 심전도(ECG)와 SPO2를 이용하여 혈류속도를 측정하였다. 심전도(ECG)와 손가락 검지손가락 끝의 SPO2농도로 얻는 맥파를 동시에 측정하여 두 파형의 피크값의 시간차를 분석하여 혈류속도를 계산하는 방법을 연구하였다. 심전도(ECG)와 SPO2를 동시 측정 분석하는 시스템으로서 정상인 10명과 임상참가자 3명에 대한 심전도(ECG)와 손가락 검지 손가락 끝의 SPO2농도로 얻는 맥파를 동시에 측정하여 비교 분석한 결과 자료에서 보는 것과 같이, 심혈관계 환자들이 일반적으로 혈류 속도가 빠르다는 것일 볼 수 있다. 또한 정상인들 중에서도 남자와 여자의 속도차이가 있음을 알 수 있다.

Urgent Intracranial Carotid Artery Decompression after Penetrating Head Injury

  • Kim, Seong Joon;Park, Ik Seong
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.3
    • /
    • pp.180-182
    • /
    • 2013
  • We describe a case of intracranial carotid artery occlusion due to penetrating craniofacial injury by high velocity foreign body that was relieved by decompressive surgery. A 46-year-old man presented with a penetrating wound to his face. A piece of an electric angular grinder disc became lodged in the anterior skull base. Computed tomography revealed that the disc had penetrated the unilateral paraclinoid and suprasellar areas without flow of the intracranial carotid artery on the lesion side. The cavernous sinus was also compromised. Removal of the anterior clinoid process reopened the carotid blood flow, and the injection of glue into the cavernous sinus restored complete hemostasis during extraction of the fragment from the face. Digital subtraction angiography revealed complete recanalization of the carotid artery without any evidence of dissection. Accurate diagnosis regarding the extent of the compromised structures and urgent decompressive surgery with adequate hemostasis minimized the severity of penetrating damage in our patient.

Effects of chemical restraint drugs on Doppler echocardiography in normal dogs (화학적 보정약이 정상견의 도플러 심초음파에 미치는 영향)

  • Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.2
    • /
    • pp.413-418
    • /
    • 1998
  • Intracardiac velocities were determined and the wave-forms described for 4 flow areas of the normal canine heart following administration of chemical restraint drugs including xylazine HCl, ketamine HCl, and thiopental sodium using pulsed wave Doppler echocardiography. The result was that xylazine HCl and thiopental sodium reduced intracardiac flow velocities through mitral, tricuspid, aortic and pulmonary valves. It is also thought that precautions are required before using these drugs. Patterns of wave-forms had no changes between control and treatment groups. Doppler echocardiography allows the clinician to determine flow velocities across the different valves and within the various chambers of the heart. It is shown that establishing normal values and those related to chemical restraint administrations and knowing what influences them should allow the clinician to non-invasively diagnose a variety of pathological cardiac conditions.

  • PDF

EFFECTS OF UNIFORM SHEAR STRESS ON THE MIGRATION OF VASCULAR ENDOTHELIAL CELL (균일한 전단응력에 의한 혈관내피세포의 운동성 변화)

  • Shin, Jennifer H.;Song, Suk-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1404-1408
    • /
    • 2008
  • The migration and proliferation of vascular endothelial cells (VEC), which play an important role in vascular remodeling, are known to be regulated by hemodynamic forces in the blood vessels. When shear stresses of 2, 6, 15 dynes/$cm^2$ are applied on mouse micro-VEC in vitro, cells surprisingly migrate against the flow direction at all conditions. While higher flow rate imposes more resistance against the cells, reducing their migration speed, the horizontal component of the velocity parallel to the flow increases with the flow rate, indicating the higher alignment of cells in the direction parallel to the flow at a higher shear stress. In addition, cells exhibit substrate stiffness and calcium dependent migration behavior, which can be explained by polarized remodeling in the mechanosensitive pathway under shear stress.

  • PDF

A Study on measurement blood velocity according to variable changing in magnetic resonance phase contrast image (자기공명 위상대조도 기법에서 병렬영상기법 변화에 따른 혈류정량 측정에 관한 연구)

  • Cho, yong-bum;Yang, seon-wook;Son, soon-yong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.107-108
    • /
    • 2017
  • 3차원 위상대조도 기법의 단점인 긴 검사시간으로 인해 임상적 유용성이 떨어진다. 본 논문은 시간매개변수인 병렬영상기법(Grappa) 변경에 따른 혈류정보의 정량적 평가를 통해 차이점을 알아보고 임상적 활용정도를 평가하였다. 자체 제작한 혈류팬텀을 통해 실험하였으며, Grappa을 5번 변경하여 실험하였다. 연구결과, Grappa를 적용하지 않았을 경우 혈류속도는 평균 9.42로 총 4단계를 적용한 혈류속도 차이율은 각각(1.4, 1.5, 0.4, 1.5%)이었으며 flow와 WSS도 각각(1.4, 1.6, 0.8, 25%), (2.1, 1.4, 1.1, 0.8%)이었다. 통계적으로도 유의하지 않아 Grappa를 적용하지 않은 검사법과 혈류정보가 동일하였다.(P>0.05) 긴 검사 시간으로 인해 임상적 활용이 떨어지는 짧은 검사시간을 요하는 소아환자나 중등도 환자 또는 폐쇄공포증 환자에게 시간을 단축한 3차원 위상대조도 기법을 사용하여 단점을 보완한다면 임상적 활용가치가 높아질 것이라 사료된다.

  • PDF

Blood Flow in an Aortic Bifurcation Model: Pulsed Doppler Ultrasound and Laser Doppler Anemometry Studies (대동맥분기에서의 혈액유동: 맥도플러초음파 및 레이저도플러계측기를 사용한 연구)

  • Kim, Young-H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.43-46
    • /
    • 1992
  • $\underline{In\;vitro}$ velocity measurements were made using both the pulsed Doppler ultrasound (PDU) machine and laser Doppler anemometer (LDA) system in order to investigate the flow characteristics near the aortic bifurcation. Velocities measured from the PDU machine was in good agreement with those from the LDA. The flow in the daughter branches was three-dimensional with a secondary flow. The oscillating wall shear stress with this secondary fluid motion is well correlated with the localization of the atherosclerosis.

  • PDF

A case of pulmonic stenosis in a Shihtzu dog

  • Park, Chul;Yoo, Jong-Hyun;Jung, Dong-In;Kim, Ju-Won;Kang, Byeong-Teck;Park, Hee-Myung
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.1
    • /
    • pp.99-102
    • /
    • 2007
  • A 3-year-old, intact female, Shih-tzu dog was presented with a 15-day history of vomiting,depression, and anorexia. On physical examination, systolic ejection murmurs with precordial thril atthe left heart base were detected. A diagnosis of congenital pulmonic stenosis (PS) was made mainlyfrom the thoracic radiography, electrocardiography, and echocardiography. On complete blood counts andconfirmed that main pulmonary artery was tremendously buldged and electrocardiography was suggestiveof severe right ventricular hypertrophy. Echocardiographic findings revealed the pulmonic valve stenosiscontaining valvular dysplasia and poststenotic dilation. On Doppler echocardiography, ejection velocityof the lesion accounted for 3.38 m/sec, meaning mild velocity through the stenotic area. The dog'sproblem and resulted in death. However, there has been no reliable relation between PS and CRF. Primarymalformation of pulmonic valve was confirmed at necropsy after death.

Rotatory Vertebral Artery Syndrome in Foramen Magnum Stenosis (대공협착에서 발생한 회전척추동맥증후군)

  • Jung, Ileok;Jung, Jin-Man;Park, Moon Ho
    • Research in Vestibular Science
    • /
    • v.17 no.4
    • /
    • pp.167-169
    • /
    • 2018
  • Rotatory vertebral artery syndrome (RVAS) is characterized by recurrent attacks of vertigo, nystagmus, and syncope induced by compression of the vertebral artery during head rotation. A 60-year-old man with atlas vertebrae fracture presented recurrent attacks of positional vertigo. Left-beat, upbeat and count clock-wise torsional nystagmus occurred after lying down and bilateral head roll (HR) showing no latency or fatigue. Magnetic resonance imaging revealed foramen magnum stenosis (FMS) and dominancy of right vertebral artery (VA). The flow of the right VA on transcranial Doppler decreased significantly during left HR. The slower the velocity was, the more the nystagmus was aggravated. RVAS can be evoked by FMS causing compression of the VA. And the nystagmus might be aggravated according to the blood flow insufficiency.

Multifunctional Robotic Guidewire System using Spiral-type Magnetic Microrobot with Magnetic Manipulation

  • Yu, Chang-Ho;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.616-621
    • /
    • 2016
  • This paper presents a new multifunctional active guidewire system for medical applications that uses a magnetic microrobot. The study demonstrated that the proposed microrobot system could swim and be controlled under Low-Reynolds-number (Re) environments in blood vessel models. The prototype of the robotic guidewire, which is driven within a three-axis Helmholtz coil system, consists of a guide-wire, spiral blade, drilling tip, and permanent magnet. The spiral-type microrobot showed stable active locomotion between 3 kA/m and 9.1 kA/m under driving frequency up to 70 Hz in a silicone oil (of viscosity 1000 cst). The microrobot produced a maximum moving velocity of $8.08{\times}10^{-3}m/s$ at 70 Hz and 9.1 kA/m. In particular, the robotic guidewire produced 3D locomotion with drilling in the three-axis Helmholtz coil system. We verified active locomotion, towing of guidewire, steering, and drilling of the proposed robotic guidewire system through experimental analyses.

Serum interleukin-6, tumor necrosis factor-α and adiponectin levels in Kawasaki disease (가와사키병 환자의 혈청 interleukin-6, tumor necrosis factor-α, Adiponectin 치에 대한 연구)

  • An, Jung;Kim, Han Gyu;Sohn, Sejung;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.1
    • /
    • pp.41-47
    • /
    • 2010
  • Purpose : Adiponectin is an endogenous modulator of vascular remodeling that suppresses vascular inflammation. However, the role of adiponectin in Kawasaki disease (KD) has not been elucidated. The purpose of this study is to investigate the correlation between serum adiponectin level and several parameters, such as interleukin (IL)-6, tumor necrosis factor $(TNF)-{\alpha}$, lipid profile, and C reactive protein (CRP), and to clarify the association between adiponectin and cardiac function. Methods : Twenty-two KD patients (22 patients in acute phase and 20 patients in subacute phase) were enrolled in the study group. The control group consisted of 31 subjects (13 febrile patients and 18 healthy children). Both groups underwent blood sampling and tissue Doppler imaging (TDI). Results : CRP was significantly increased in the KD group compared with the control group. There were no significant differences in serum $TNF-{\alpha}$, IL-6, and adiponectin levels between groups. However, a negative correlation was found between adiponectin level and CRP level or platelet count. Systolic myocardial velocity and A myocardial velocity measured by TDI were decreased significantly in the acute KD group compared with the subacute KD group and control group. Positive correlations were found between adiponectin level and systolic myocardial velocity or A myocardial velocity. Conclusion : In acute KD patients, low adiponectin level was related to severe inflammatory reactions and decreased left ventricular functions.