• 제목/요약/키워드: blood pulsation effect

검색결과 9건 처리시간 0.042초

Blood Pulsation의 효과가 뇌 활성화에 미치는 영향을 알아보는 방법 (Estimation Method for Brain Activities are Influenced by Blood Pulsation Effect)

  • 이원호;구정훈;이형래;한기완;박진식;김재진;윤강준;김인영;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권3호
    • /
    • pp.338-343
    • /
    • 2007
  • BOLD T2*-weighted MR images reflects cortical blood flow and oxygenation alterations. fMRI study relies on the detection of localized changes in BOLD signal intensity. Since fMRI measures the very small modulations in BOLD signal intensity that occur during changes in brain activity, it is also very sensitive to small signal intensity variations caused by physiologic noise during the scan. Due to the complexity of movement of various organs associated with heart beat, it is important to reduce cardiac related noise rather than other physiological noise which could be required with relatively simple method. Therefore, a number of methods have been developed for the estimation and reduction of cardiac noise in fMRI study. But, each method has limitation. In this study, we proposed a new estimation method for brain activities influenced by blood pulsation effect using regression analysis with blood pulsation signal and the correspond slice of fMRI. We could find out that the right anterior cingulate cortex and right olfactory cortex and left olfactory cortex were largely influenced by blood pulsation effect for new method. These observed areas are mostly on the structure of anterior cerebral artery in the brain. That is convinced with that our method would be valid and our new method is easier to apply in practice and reduce computational burden than the retrospective method.

뜸치료가 뇌졸중 편마비의 요골동맥 혈류변화에 대해 미치는 영향 (Noninvasive Estimation of Moxibustion Effect on Peripheral Blood Flow by Doppler Ultrasound in Stroke Patients with Hemiplegia: Case Series)

  • 윤승규;이상훈;정우상;배영민
    • 대한한의학회지
    • /
    • 제31권4호
    • /
    • pp.178-186
    • /
    • 2010
  • Objectives: This study was to investigate the effect of moxibustion on peripheral blood flow by Doppler ultrasound in post-stroke hemiplegia patients. Methods: Moxibustion was applied on the points of LI4, TE3, TE5 and LI11 on the affected side, and blood flow of the radial artery was measured using the Minimax-Doppler-K device. Blood flow velocity and pulsation index were analyzed before, during, and after moxibustion. Results: The mean value of blood flow velocity in 13 patients showed a tendency of increase during moxibustion, but there was no significant difference in blood flow velocity before and after moxibustion, or pulsation index during and after moxibustion. In addition, among the five patients who showed marked increase tendency on the blood velocity graph, there was significant increase in blood velocity during, and after moxibustion compared with before moxibustion. Conclusions: This study suggests that moxibustion has an effect on peripheral blood flow in stroke patients with hemiplegia. Further validity tests with a larger scale sample are needed for the evidence of its practical use.

토노메트리 측정 관점에서의 부침맥 고찰 (Review on Floating Pulse and Sinking Pulse in the View Point of Tonometric Measurement)

  • 이전;이유정;유현희;이혜정;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권2호
    • /
    • pp.113-119
    • /
    • 2008
  • In pulse diagnosis, floating pulse and sinking pulse are frequently used for diagnosis about where disease is located and how much severe they are. However, in what mechanism floating pulse and sinking pulse arise is not known well. There are two point of views on substantial of floating pulse and sinking pulse. The first one is the floating and sinking degrees is the expression on the depth of pulsation. And, the second one is floating and sinking pulse is based on the response of pulsation to the indent pressure on radial artery. In this paper, we discussed these two opinions in the view point of tonometric measurement. The process for diagnosis on floating pulse and sinking pulse is similar to the tonometric measurement for non invasive blood pressure or intraocular pressure. We modelled the degrees of depth of pulsation with different indent pressures for initial pulsation feeling and different slopes of indent pressure lines. From this modelling, we can confirm the effect of pulsation depth on P-H curve, that is, in the model where lower pulsation is assumed, the shift of optimal indent pressure to the right was observed. The response of pulse pressure to the indent pressure was tried to be modelled with the degrees of mean blood pressure. Consequently, we tried to model the phenomenon of floating and sinking pulse for the first. And, from this modelling, we can get abundant understanding on how floating and sinking pulse can be caused. In the further study, we want to prove the suitability of this tonometric measurement based modelling with various studies including ultrasound measurement for the depth of pulsation in different EMI subjects.

  • PDF

The Effect of Pulsatile Flow on Ultrafiltration In-Vitro Study and Comparison with Roller Pump

  • Lee K.;Jeong J. H.;Mun C. H.;Lee J. C.;Min B. G.
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.337-341
    • /
    • 2005
  • Blood pulsation has been reported to have an advantageous effect on extracorporeal blood circulation. However, the study of pulsatile blood flow in renal replacement therapy is very limited. The in-vitro experimental results of pulsatile blood flow on ultrafiltration, when compared with the conventional roller pump, are described in this paper. Methods: Blood flow rate (QB) and transmembrane pressure (TMP) were considered as regulating factors that have an influence on ultrafiltration. Experiments were performed under the condition of equal TMP and OB in both pulsatile and roller pump groups, Several kinds of hollow fiber dialyzers were tested using distilled water containing chemicals as a blood substitute. Mean TMP (mTMP) varied from 10 to 90mmHg while the QB was 200ml/min. Results: Ultrafiltration rate (QUF) was found to be linearly proportional to TMP, whereas QB had little influence on QUF. In addition, QUF was higher in the pulsatile group than the roller pump group at the identical TMP. Conclusion: In the controlled test, QUF increased solely as a consequence of blood pulsation, which implies that the pulse frequency represents an additional and important clinical variable during renal replacement therapy.

한방기공체조가 두뇌력, 심박변이율, 생혈액형태에 미치는 영향 (Effect of the Oriental Medicine Gi-Gong Exercise on the Brain Power, HRV, Live Blood Condition in the Youth)

  • 이정원;김이순;김경철
    • 동의생리병리학회지
    • /
    • 제21권1호
    • /
    • pp.126-135
    • /
    • 2007
  • This study was conducted to identify the effects of the oriental medicine Qigong Exercise on the brain power, HRV, pulsation, live blood condition among young boys and girls. The study was performed with two group(control group and experimental group) in a pre-test/post-test design. The subjects were 44 young boys and girls selected by a some middle school in Busan. The oriental medicine Qigong Exercise program consists of 80-minute sessions three times a week over 5 months. All of the subjects were examined on the congnition assessment tool, stress assessment tool, oriental medicine pulsation 3-D MAC, live blood condition analyzer Prior and post surveys were measured before and after the experiment. In the cognition assessment, the amplitude of ERS were increased afer Qigong Exercise. The Success and the Concentration were significantly increased afer Qigong Exercise, the Error was significantly decreased afer Qigong Exercise. The Cognition strength was significantly increased, but the Reponse time was not significantly decreased afer Qigong Exercise. And the Workload was not significantly decreased, the Total Score was not significantly increased afer Qigong Exercise. Among the stress assessment, RRV tachogram's ‘mean RR’ was significantly increased, ‘mean HRV’ was significantly decreased afer Qigong Exercise. SDNN was not significantly increased, Complexity was not significantly increased afer Qigong Exercise. And TP(RRV power's total power) was not significantly increased, VLF and HF was significantly increased, and LF was significantly decreased afer Qigong Exercise. ANS's norm LF was not significantly decreased, but norm HF was significantly increased afer Qigong Exercise. In the RRV's Phase Plot, RMSSD and SDSD were not significantly increased, pnn50 was not significantly decreased afer Qigong Exercise. On the whole, Parasympathetic Activity and Stress Endurance were significantly increased, but Cardiac Activity and Physical Arousal were not significantly increased afer Qigong Exercise. Cardiac Aging was not significantly decreased afer Qigong Exercise. Sympathetic Activity, Autonomic Nervous System Balance and Heart-load were not significantly decreased afer Qigong Exercise. In the pulsation, press power was increased(15%), and w/t(pressurization time / pulsation time) was decreased(20%) afer Oigong Exercise. And the live blood condition was not changed afer Qigong Exercise. As mentioned above; the oriental medicine Qigong Exercise program was identified the effects of the inspiration of the brain power, heart rate and anti-stress.

합곡.중저.외관.곡지 뜸치료가 뇌졸중 편마비 환자의 환측 요골동맥 혈류 및 심박변이도에 미치는 영향 (The Effects of LI4, TE3, TE5 and LI11 Moxibustion on Radial Artery Blood Flow and Heart Rate Variability in Stoke Patients with Hemiplegia)

  • 윤승규;권승원;서유리;박준영;임진욱;박주영;조승연;정환용;박성욱;정우상;문상관;박정미;고창남;조기호;김영석;배형섭;이상훈;배영민
    • 대한한의학회지
    • /
    • 제32권5호
    • /
    • pp.50-65
    • /
    • 2011
  • Objectives: Moxibustion has been used for various post-stroke symptoms and has also been known to have effect on peripheral blood flow. This study investigated the effect of moxibustion on radial artery blood flow by Doppler ultrasound and on heart rate variability in post-stroke hemiplegia patients. Methods: Moxibustion was applied on the points of LI4, TE3, TE5 and LI11 on the affected side, and blood flow of the radial artery was measured using the Minimax-Doppler-K device. Blood flow velocity and pulsation index were analyzed before, during, and after moxibustion. Simultaneously LF, HF, and LF/HF as variables for HRV were measured by FM-150. Results: The mean value of blood flow velocity in all patients (n=23) showed significant increase between before and after moxibustion, but there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. In Yin (n=9) and Yang (n=14) groups, both showed significant increase of blood flow velocity between before and after moxibustion, but there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. In Deficiency (n=14) and Fullness (n=9) groups, only the Deficiency group showed significant increase of blood flow velocity between before and after moxibustion, while the Fullness group showed no significant difference in blood flow velocity between before and after moxibustion, and also there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. Conclusions: This study suggests that moxibustion on LI4, TE3, TE5 and LI11 on the affected side of stroke patients increase the peripheral blood flow in the affected arm, which was most remarkable in those with Yin and Deficiency pattern.

척택.어제 침자가 고해상도 적외선 카메라로 관찰한 촌구맥 부위의 온도 Pulsation 변화에 미치는 영향 연구 (Effect of Acupuncture at the LU5(Reinforcement), LU10(Reduction) on the Pulsation Scale of Chon, Gwan and Chuk region using High Resolution Infrared Camera)

  • 나창수;정효상;김지현
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권2호
    • /
    • pp.127-133
    • /
    • 2011
  • Arteria radialis is a branch of the brachial artery extending down the forearm around the wrist where it closes to skin surface. In the oriental medicine, the skin above arteria radialis has an important role because oriental medicine practitioners put their finger tips on the area, and diagnose patient's health conditions by feeling the pulsation of the arterial contraction. The finger tip diagnostic method relies on subjective decision of the practitioner; and there is a need to develop an objective diagnostic modality. The pulsation of the arterial contraction appears not only a movement on the site but also as temperature fluctuation due to pulsatile feeding of warmer blood. The goal of this study is to demonstrate a feasibility of using an infrared camera quantitatively to detect the temperature fluctuation on the skin. Clinical important three different areas, called chon, gwan, chuk, near a wrist where the arteria radialis reaches close to skin surface are marked with small pieces of surgical tape. A high-speed and high-resolution infrared camera with a 3 cm of field of view measures these areas for 10 second at 200 frames per second with a 320*240 pixel size. The pulsatile temperature fluctuation is calculated after passing a band pass filter to remove any stationary temperature over 10 second. The temperature fluctuation of a healthy male volunteer is measured at a room temperature as a control, and is compared with another measurement performed after 20 minutes staying in a room at a 40 degree Celsius. This comparison is repeated for three times, and indicates that the fluctuation increases after staying 20 minutes in the warm room. This increase becomes smaller when the person stays in the warm room with an acupuncture treatment that decreases body temperature. So that an objective diagnostics on the site may become feasible.

${\cdot}$ 냉 적용이 Vital sign 및 혈액 성분에 미치는 영향 (The Effects of Hot and Cold Therapy on Vital Sign and Blood Components)

  • 박규현;전경희;박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제13권2호
    • /
    • pp.313-324
    • /
    • 2001
  • The 15 male students of T-college which is located in Taegu, who don't have any cardiovascular diseases and skin diseases and agreed to the experiment for finding out the effects of hot and cold therapy. They were divided 5 experimental groups, that is hot therapy in blood Pressures, hot therapy group showed significantly difference of systolic blood Pressure. And the hot therapy group and hot and cold therapy showed the distinctive differences in Scheffes' s analysis after the fact. 3. There was no significant difference in pulsation between before and after experiment and there were no differences in each group. 4. The hot therapy group showed significant difference in WBC and didn't show any difference in RBC(p<.05). 5. Timing does not effect to each group in the changes of HGB and HCT. 6. In the comparison between before and after the experiments in the changes of MCV, cold therapy group showed significant measurement. And in the comparison between before and after one hour the experiment in the changes of MCV, cold therapy group showed significant measurement. The experimental group 1 and 3 showed the distinctive differences in Scheffe' s analysis after the fact(p<.05). 7. In the comparison between before and after one hour experiments in MCV changes, the cold therapy group had significant differences(p<.05). 8. There were no significant differences between before and after the experiments in MCHC changes. 9. In the comparison between before and after one hour experiments in PLT changes, cold therapy group had significant changes(p<.05) and there were no differences among three group.

  • PDF

고주파 통증치료기를 이용한 재활 치료에 대한 연구 (A Study on Rehabilitation Treatment Using Radiofrequency Treatment)

  • 조재현;이상용;이근용;윤세진;정하영;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권3호
    • /
    • pp.212-218
    • /
    • 2020
  • 인체에 고주파 에너지를 가하면 진동 폭이 매우 짧아서 직류 전류 이용 시 발생하는 전해질 화상이 일어나지 않으며 이온분자, 분극분자 등이 초당 4만 번 이상 진동을 하면서 마찰열로 전환되어 심부열을 발생시켜 모세혈관의 혈류량은 휴식 시 보다 4~5배 증가하여 산소, 영양물질, 항체, 백혈구 등 공급의 증가한다. 또한 진동 폭과 맥동기간이 매우 짧아 전기 화학적 반응이 일어나지 않으며 감각신경과 운동신경을 자극하지 않는 물리적 인자치료 방법이다. 본 연구에서는 고주파통증치료기를 사용하여 젊은 정상 성인을 대상으로 등장성운동을 시키고, 등장성 운동 시 근전도 데이터를 측정하여 운동신경 응답의 변화에 미치는 영향을 확인하여 재활치료 접목시키고자 하였다. 윗팔두갈래근의 등장성 운동을 실시할 때 발생되는 근전도 데이터와 운동 후 고주파통증치료기사용 후 측정된 근전도 데이터를 각각 RMS하여 t-검정을 통하여 검증을 실시하였으며, 남녀 모두 t값, p값이 유의수준(<.05) 보다 작게 나와 유의한 차이가 있다는 것을 확인하였다.