The Effect of Body Positioning on Physiologic Index in Patients with Unilateral Lung Disease (편측성 폐질환 환자의 체위변경이 생리적 지표에 미치는 영향)

  • Cho, Jee Yeon;Lee, Hyang Yeon
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.1
    • /
    • pp.122-133
    • /
    • 2000
  • The purpose of this study was to identify the effect of body positioning on $PaO_2$, $SpO_2$, systolic blood pressure, diastolic blood pressure, pulse, and respiration(above all defined physiologic index), of patients with unilateral lung disease. The subjects for this study were eleven patients admitted to I.C.U. of K.H.M.C. with a diagnosis of unilateral lung disease confirmed by chest X-ray and the attending doctor, from January 30th. to April 20th. 1999. A quasi-experimental repeated-measures cross-over design was used to compare three body positions(semi-Fowler's, lateral decubitus with good lung dependent, and lateral decubitus with diseased lung dependent). Each subject spent 30 minutes in semi-Fowler's position and 2 hours in good lung dependent position and diseased lung dependent position. Starting in the semi-Fowler's position, then in the lateral position with the good lung dependent or the diseased lung dependent as assigned in random order. Thirty minutes after each positioning, arterial blood sample was analyzed. Measurements of all physiologic index were recorded at the specified intervals(0, 30, 60 90, and 120 minutes) in good lung dependent and diseased lung dependent position. Statistical comparison of $PaO_2$ value was done using the Wilcoxon Signed Rank Test, and Multivariate repeated-measures analysis of variance was performed to analyse the within-subject effect of two dependent position for 2 hours on the five dependent variables: (1) $PaO_2$ (2) $SpO_2$ (3) systolic blood pressure (4) diastolic blood pressure (5) pulse. The results obtained were as follows: 1. The $PaO_2$ value in the good lung dependent position was significantly higher than the $PaO_2$ value in the diseased lung dependent position(Z=-2.8451, p=.002). 2. The $PaO_2$ value in the good lung dependent position was significantly higher than the $PaO_2$ value in the semi-Fowler's position (Z=-2.6673, p=.003). 3. The difference between the $PaO_2$ value in the semi-Fowler's position and the $PaO_2$ value in the diseased lung dependent position was not significant(Z=-1.2448, p=.10). 4. There were no statistically significance in the trends of physiologic index in the good lung dependent position and the diseased lung dependent position. From the results, it may be concluded that the good lung dependent position is the most effective position for patients with unilateral lung disease that improve oxygenation. Identification of positioning over time may be need further studies.

  • PDF

Experimental Studies on Extracorporeal Circulation by Rygg-Kyvsgaard Heart-Lung Machine, Hartman`s Solution Prime,and Moderate Hypothermia: [Part I] (Hartmann`s 용액으로 충진한 혈희석 체외순환에 관한 실험적 연구: (1보: 심폐기 Rygg-Kyvsgaard 의 혈산화와 혈압 및 혈액상에 미치는 영향))

  • 지행옥
    • Journal of Chest Surgery
    • /
    • v.4 no.2
    • /
    • pp.69-80
    • /
    • 1971
  • Total body perfusion using Rygg-Kyvsgaard Heart-Lung-Machine, Mark IV, Polystan was attempted in the dogs by the hemodilution method with total prime of buffered Hartman's solution and under hypothermia. The first of all, the functions of Rygg--Kyvsgaard Heart-Lung-Machine and the effects of the hemodilution perfusion by buffered Hartman's solution was studied. At the same time the changes of blood pressure, oxygen consumption, and influence on the blood pictures were observed before, during, and in 1-3 days after perfusion. Hemodilution rates were the average 74. 22cc/Kg(the ranges of 67 to 81 cc/Kg) and perfusion flow rates were maintained in the mean 62. 6cc/Kg/min., Although it was possible to check up to 87 cc/ Kg/min. The total body perfusion continued for 60-80 minutes. Hypothermia was employed between $36^{\circ}C$ and $32^{\circ}C$ of the rectal temperature. Arterial pressure was ranged approximately between 68mmHg and 149mmHg, but generally, it was maintained over 80mmHg. Venous pressure was measured between 6.5cm $H_2O$and 11.5cm $H_2O$. Optimum oxygenation can be expected when oxygen flow into the disposable bubble oxygenator was maintained approximately at 3.5 L/min .. Inthis way, the oxygen contents were measured in the mean value of 13.11${\pm}$O.56 vol. % of arterial blood and 8.67+1.08 vol.% of venous blood(P${\pm}$0.86 vol.% in arteriovenous oxygen difference and 2. 97${\pm}$0.62cc/Kg in oxygen consumption were calculated. According to these dates, it is as plain as pikestaff that excellent oxygenation and good tissue perfusion was accomplished. Erythrocyte, hemoglobin and hematocrit were decreased about 38% during extracorporeal circulation and these were not recovered until 1-3 days after perfusion. These decrease was resulted from relatively high degree of hemodilution rate and no blood transfusion to compensate during these experimental studies. The platelets were also decreased about 76% during perfusion, but on the contrary, it was increased progressively after perfusion and in 1-3 days after perfusion was returned to the control level. Leucocyte were also decreased during perfusion, but it was increased progessively after perfusion and in 1-3 days after perfusion exceed the control level. This increase was resulted from postoperative infection of the wound, but its analysis were not changed significantly.

  • PDF

Role of Blood Flow vs. $O_{2}$ Consumption in Nicotinamide-induced Increase $pO_{2}$ in a Murine Tumor (Nicotinamide에 의한 종양내 산소 분압의 증가에 있어서 혈류 또는 산소 소모의 역할)

  • Lee Intae;Demhartner Thomas J.;Cho Moon-June
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.17-25
    • /
    • 1994
  • We evaluated the effect of nicotinamide on cellular $O_{2}$ consumption and metabolic status i.e., adenylate phosphates and $NAD^{+}$in-vitro, and changes in blood flow in-vivo, to determine whether changes in cellular metabolism or increased oxygen availability, was responsible for increased tumor oxygenation. Thirty min, pre-incubation of cells with$\∼$4mM (= 500mg/kg) nicotinamide resulted in no change in cellular $O_{2}$ consumption. Similarly neither the adenylate Phosphates nor the cellular $NAD^{+}$levels were altered in the presence of $\∼$4mM nicontinamide. In-vivo, nicotinamide (500mg/kg) increased $O_{2}$ availability as estimated by changes in relative tumor blood flow (RBC flux). The changes in RBC flux measured by the laser Doppler method, were tumor volume dependent and increased from$\∼$35$ \% $ in$\∼$ 150$mm_{3}$tumors to$\∼$~75$ \% $ in$\∼$500$mm^{3}$ tumors. In conclusion, these observations indicate a reduction in local tissue $O_{2}$ consumption is not a mechanism of improved tumor oxygenation by nicotinamide in FSa II murine tumor model. The primary mechanism of increased $pO_{2}$ appears to be an increased local tumor blood flow.

  • PDF

The Effects of Physiological Heating and Exercise on the Optical Properties of Biological Tissue. (가열과 운동에 의한 생체조직내의 생리적 변화에 따른 광학적 특성의 변화에 관한 연구)

  • Lim, Hyun-Soo;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.81-88
    • /
    • 1993
  • This paper is the study of the reflectance of light from biological tissue for red and Infrared wavelengths and relates the acquired reflectance data to expected physiological changes within the skin and muscle layers associated with heat and exercise. The instrument was disigned to collect data from the calf muscle in human subjects with probe located at the surface of skin. Rapid data acquisition method allowed monitoring of rapid changes in reflecttance due to a stimulus. This study demonstrates that changes in O2 saturation and blood fractional volume expected within the dermis and muscle layers were asserted by examining the slopes of the plotted index for heat and exercise. The results presented in thls study support the claim that reflectance can separately discriminate between changes of blood volume and oxygenation in muscle and in skin. The data demonstrate the ability to measure consistent changes In tissue optical properties during exercise and heat.

  • PDF

Polydeoxyribonucleotide Improves Peripheral Tissue Oxygenation and Accelerates Angiogenesis in Diabetic Foot Ulcers

  • Kim, Seoyoung;Kim, Junhyung;Choi, Jaehoon;Jeong, Woonhyeok;Kwon, Sunyoung
    • Archives of Plastic Surgery
    • /
    • v.44 no.6
    • /
    • pp.482-489
    • /
    • 2017
  • Background Polydeoxyribonucleotide (PDRN) is known to have anti-inflammatory and angiogenic effects and to accelerate wound healing. The aim of this study was to investigate whether PDRN could improve peripheral tissue oxygenation and angiogenesis in diabetic foot ulcers. Methods This was a prospective randomized controlled clinical trial. Twenty patients with a non-healing diabetic foot ulcer were randomly distributed into a control group (n=10) and a PDRN group (n=10). Initial surgical debridement and secondary surgical procedures such as a split-thickness skin graft, primary closure, or local flap were performed. Between the initial surgical debridement and secondary surgical procedures, 0.9% normal saline (3 mL) or PDRN was injected for 2 weeks by the intramuscular (1 ampule, 3 mL, 5.625 mg, 5 days per week) and perilesional routes (1 ampule, 3 mL, 5.625 mg, 2 days per week). Transcutaneous oxygen tension ($TcPO_2$) was evaluated using the Periflux System 5000 with $TcPO_2/CO_2$ unit 5040 before the injections and on days 1, 3, 7, 14, and 28 after the start of the injections. A pathologic review (hematoxylin and eosin stain) of the debrided specimens was conducted by a pathologist, and vessel density (average number of vessels per visual field) was calculated. Results Compared with the control group, the PDRN-treated group showed improvements in peripheral tissue oxygenation on day 7 (P<0.01), day 14 (P<0.001), and day 28 (P<0.001). The pathologic review of the specimens from the PDRN group showed increased angiogenesis and improved inflammation compared with the control group. No statistically significant difference was found between the control group and the PDRN group in terms of vessel density (P=0.094). Complete healing was achieved in every patient. Conclusions In this study, PDRN improved peripheral tissue oxygenation. Moreover, PDRN is thought to be effective in improving inflammation and angiogenesis in diabetic foot ulcers.

Effects of small tidal volume and positive end-expiratory pressure on oxygenation in pressure-controlled ventilation-volume guaranteed mode during one-lung ventilation

  • Byun, Sung Hye;Lee, So Young;Jung, Jin Yong
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.2
    • /
    • pp.165-170
    • /
    • 2018
  • Background: The purpose of this study was to investigate whether tidal volume (TV) of 8 mL/kg without positive end-expiratory pressure (PEEP) and TV of 6 mL/kg with or without PEEP in pressure-controlled ventilation-volume guaranteed (PCV-VG) mode can maintain arterial oxygenation and decrease inspiratory airway pressure effectively during one-lung ventilation (OLV). Methods: The study enrolled 27 patients undergoing thoracic surgery. All patients were ventilated with PCV-VG mode. During OLV, patients were initially ventilated with TV 8 mL/kg (group TV8) without PEEP. Ventilation was subsequently changed to TV 6 mL/kg with PEEP ($5cmH_2O$; group TV6+PEEP) or without (group TV6) in random sequence. Peak inspiratory pressure ($P_{peak}$), mean airway pressure ($P_{mean}$), and arterial blood gas analysis were measured 30 min after changing ventilator settings. Ventilation was then changed once more to add or eliminate PEEP ($5cmH_2O$), while maintaining TV 6 mL/kg. Thirty min after changing ventilator settings, the same parameters were measured once more. Results: The $P_{peak}$ was significantly lower in group TV6 ($19.3{\pm}3.3cmH_2O$) than in group TV8 ($21.8{\pm}3.1cmH_2O$) and group TV6+PEEP ($20.1{\pm}3.4cmH_2O$). $PaO_2$ was significantly higher in group TV8 ($242.5{\pm}111.4mmHg$) than in group TV6 ($202.1{\pm}101.3mmHg$) (p=0.044). There was no significant difference in $PaO_2$ between group TV8 and group TV6+PEEP ($226.8{\pm}121.1mmHg$). However, three patients in group TV6 were dropped from the study because $PaO_2$ was lower than 80 mmHg after ventilation. Conclusion: It is postulated that TV 8 mL/kg without PEEP or TV 6 mL/kg with $5cmH_2O$ PEEP in PCV-VG mode during OLV can safely maintain adequate oxygenation.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Clinical Application of OXYREX Hollow Fiber Membrane Oxygenator (국산 막형 산화기 (OXYREX)의 체외순환 임상 성적 - 개심수술 40례 적용 -)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1049-1056
    • /
    • 1990
  • The OXYREX hollow fiber membrane oxygenator developed by joint work of KIST and Green Cross Medical company has been evaluated by experimental investigation and clinical application, In this oxygenator gas exchanges occur through small pores of 0.1pm size which are distributed on 70% of surface of polypropylene hollow fiber. The Oxyrex membrane oxygenator consists of 36 thousand hollow fibers and it has 3.3m2 of gas exchange surface. The Oxyrex membrane oxygenator has unique blood flow path: blood enters the oxygenator passes between the hollow fibers and exits through outlet ports, that provides low transmembrane pressure drop. In the animal experiment and in vitro investigations of Oxyrex oxygenator, it showed low transmembrane pressure difference, effective heat exchanger performance, stable gas transfer function and less blood trauma. The Oxyrex oxygenator been used from March, 1990, to October, 1990, in 40 patients undergoing open heart operations. In the clinical applications of Oxyrex, adequate oxygenation[PaO2, 283$\pm$70mmHg] and carbon dioxide removal[PaCO2, 27\ulcorner6mmHg]were maintained under the condition of FiO2: below 0.6, Hct; 25%, perfusion flow; 2.4 L/min, gas flow: 2.1 L/min. During maximum 365 minutes of cardiopulmonary bypass[CPB] time period, the Oxyrex oxygenator maintained stable condition of PaO2, PaCO2 respectively and it also kept low plasma hemoglobin level. The complement proteins C3 and CH50 were not significantly changed pre to post CPB. There were no complications related to the oxygenator during and after the CPB.

  • PDF

Estimation Method for Brain Activities are Influenced by Blood Pulsation Effect (Blood Pulsation의 효과가 뇌 활성화에 미치는 영향을 알아보는 방법)

  • Lee, W.H.;Ku, J.H.;Lee, H.R.;Han, K.W.;Park, J.S.;Kim, J.J.;Yoon, K.J.;Kim, I.Y.;Kim, S.I.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.338-343
    • /
    • 2007
  • BOLD T2*-weighted MR images reflects cortical blood flow and oxygenation alterations. fMRI study relies on the detection of localized changes in BOLD signal intensity. Since fMRI measures the very small modulations in BOLD signal intensity that occur during changes in brain activity, it is also very sensitive to small signal intensity variations caused by physiologic noise during the scan. Due to the complexity of movement of various organs associated with heart beat, it is important to reduce cardiac related noise rather than other physiological noise which could be required with relatively simple method. Therefore, a number of methods have been developed for the estimation and reduction of cardiac noise in fMRI study. But, each method has limitation. In this study, we proposed a new estimation method for brain activities influenced by blood pulsation effect using regression analysis with blood pulsation signal and the correspond slice of fMRI. We could find out that the right anterior cingulate cortex and right olfactory cortex and left olfactory cortex were largely influenced by blood pulsation effect for new method. These observed areas are mostly on the structure of anterior cerebral artery in the brain. That is convinced with that our method would be valid and our new method is easier to apply in practice and reduce computational burden than the retrospective method.

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.