• 제목/요약/키워드: blood contamination

검색결과 126건 처리시간 0.026초

조직은행에서 채취한 동종조직의 세균 배양 평가 (INTERPRETATION OF BACTERIAL CONTAMINATION OF ALLOGENEIC TISSUES OBTAINED FROM CADAVERIC AND LIVING DONORS)

  • 이은영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권1호
    • /
    • pp.31-38
    • /
    • 2005
  • Thorough screening of donors medical and social history, extensive serological and bacterial screening combined with developed processing and sterilization methods have improved the safety of the allogeneic tissues in recent decades. The risk of bacterial infection through allogenic tissue transplantation is one of the major problems facing tissue banks. The purpose study is to report the contamination rate in 358 retrieved tissues obtained strictly aseptic conditions, between 2001 and 2002 in Korea Tissue Bank. Samples from 9 donors(total 13 donors) were used in blood culture, and in 7 donors the blood culture were negative. Of the 358 tissues cultured in their entirety, 186(52%) were initially culture negative and 177(48%) were positive. Organism low pathogenicity were cultures from 20.2% of the tissues. To minimize the bacterial load, donors should be obtain in operating rooms, using aseptic techniques with only a few personnel for procurement. The procurement cultures from donors and retrieved tissues with multiple should be carefully interpreted. Blood cultures should be taken account, since these can help to find contamination not detect swab culture. A prospective cohort study is needed to determine which of the varied processing and sterilization methodologies gives the best quality.

Effect of Blood Contamination on Vickers Microhardness and Surface Morphology of Mineral Trioxide Aggregate

  • Jaehyun Seung;Seong-Jin Shin;Byounghwa Kim;Ji-Myung Bae;Jiyoung Ra
    • 대한소아치과학회지
    • /
    • 제51권2호
    • /
    • pp.165-175
    • /
    • 2024
  • This study aimed to investigate the effects of blood contamination on the Vickers hardness and the surface morphology of premixed MTA and compare them with the effects on conventional MTA. The Vickers microhardness of Endocem MTA Premixed Regular (EP) and ProRoot MTA (PM) was assessed after immersion in fetal bovine serum (FBS) and saline. Stem cells from human exfoliated deciduous teeth (SHED) were seeded on MTA after immersion in FBS, saline, and deionized water (DW). Cell adhesion patterns and surface morphology were visualized via scanning electron microscopy (SEM). The surface microhardness of EP and PM in FBS was lower than in saline. However, short-term exposure of PM to FBS did not reduce the microhardness compared to saline. Angular crystals formed in water, while rounded crystals with more air voids appeared in FBS. Favorable SHED attachment occurred in all groups. Overall, the surface hardness of EP and PM decreased after FBS exposure, although PM was less influenced. We suggest minimizing the amount of bleeding when using MTA clinically; nevertheless, PM remains an option with more expected blood contamination than EP. In summary, exposure to FBS decreased mechanical performance but allowed cell adhesion for both MTAs, with PM being more resistant to these changes.

Gas Chromatography에 의한 인체혈액중에서 스미치온 및 마라치온의 분리정량에 관한 연구 (A Study on the Isolative determination of Smithion and Malathion in the Human Blood by Gas Chromatography)

  • 구성회;박성우;이영자
    • 한국환경보건학회지
    • /
    • 제5권1호
    • /
    • pp.58-60
    • /
    • 1978
  • This experiment was carried out to determine the amount of organophosphorous pesticides accumulated in farmer's blood during the farming season. The Blood had been collected for about 5ml from farmer's, and extraction was purified on a Avicel/Darco G-Co (1:10) column and determined by Gas Chromatography using AFID supported on 2% EGA. The Gas chromatographic detection yielded recoveries from the blood of 88% for smithion 94% for malathion. The amount of average contamination shows 0.045ppm for smithion. 0.054ppm for malathion.

  • PDF

대기 중 납의 RISK예측모형 개발 (The Development of Risk Predictive Model for Air-borne Lead in Blood)

  • 김종석
    • 한국환경보건학회지
    • /
    • 제19권3호
    • /
    • pp.46-51
    • /
    • 1993
  • In order to survery the risk of air-borne lead to human, the relation between air-borne lead level and blood lead level was examined by using of the kinetic model and statistical model. The results of this survey were as follows: 1. The pathways of lead intake were food and water, mainly. 2. Though blood lead level of Korean urbanire was higher than that of American or Japanese, it was not so severe as to influence human health. 3. The lead content in food and water was high, and so it is needed to confirm the cause of high content was whether second contamination by air pollution or not.

  • PDF

혈액오염이 Tricalcium Silicate 재료의 압출강도와 표면형태에 미치는 영향 (Effect of Blood Contamination on the Push-Out Bond Strength and Surface Morphology of Tricalcium Silicate Materials)

  • 박미선;김재환;최남기;김선미
    • 대한소아치과학회지
    • /
    • 제43권1호
    • /
    • pp.36-43
    • /
    • 2016
  • 이 연구의 목적은 혈액오염 시 Biodentine$^{(R)}$, Theracal$^{(R)}$, mineral trioxide aggregate(MTA)의 압출강도를 측정하고 표면형태를 관찰하는 것이었다. Biodentine$^{(R)}$, Theracal$^{(R)}$, MTA 각각의 재료를 2개의 그룹으로 나누었다. 대조군은 phosphate buffered saline 용액 조건에서, 실험군은 fetal bovine serum 조건에서 4일간 $37^{\circ}C$에서 보관하였다. 이후 압출강도를 측정하고 주사전자현미경을 이용하여 표면형태를 분석하였다. Biodentine$^{(R)}$과 Theracal$^{(R)}$은 모든 조건에서 MTA보다 유의하게 더 높은 압출강도를 보였고 혈액오염 시 모든 재료의 압출강도는 유의하게 감소하였다. 표면형태 관찰결과 혈액오염 후 모든 재료의 표면형태가 변화하였다. 혈액오염 조건에서 Biodentine$^{(R)}$과 Theracal$^{(R)}$은 MTA와 비교하여 더 높은 압출강도를 보였으므로 혈액오염 조건에 사용하기에 더 적절할 수 있다.

ICP/MS에 의한 전혈 중 납의 분석방법 연구 (A study on the determination of lead in whole blood by ICP/MS)

  • 박경수;김선태
    • 분석과학
    • /
    • 제10권4호
    • /
    • pp.240-245
    • /
    • 1997
  • ICP/MS에 의해 전혈 중의 납을 정확하게 분석하는 방법을 개발하였다. 전혈시료를 납의 오염과 손실 없이 마이크로파 분해장치에서 분해시키고, 96개 혈액시료 중의 $Pb^{208}$을 ICP/MS로 측정하여 분석하였다. 실제 인체 혈액 시료 중의 Pb 함량은 $2.50{\sim}22.8{\mu}g/dL$ 범위였다. NIST SRM 955a series를 분석함으로써 이 분석방법의 정확도를 확인하였다.

  • PDF

체외순환법에 대한 미생물학적 고찰 (Microbiological Study of the Extracorporeal Circulation)

  • 조대윤
    • Journal of Chest Surgery
    • /
    • 제13권1호
    • /
    • pp.48-51
    • /
    • 1980
  • Open heart surgery patients have additional risks arising from the special nature of the operative procedure. And postoperative infections in patients with extracorporeal circulation are associated with high incidence of serious sequelae. To investigate the incidence and organisms of contamination, and the relation between the duration of extracorporeal circulation and contamination, following study was done. Eighty-four of the open heart surgery patients were examined with cultures from the blood and priming solution before and after bypass. 1. Cultures before bypass were sterile, but 2 cases of cultures from the blood and priming solution after bypass were positive, and culture positive group was 5% of all patients. 2. The organisms were Gram-negative, aerobic coliform bacilli; 3. The culture positive group had significantly longer bypass time.

  • PDF

Microbiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments

  • Gehrke, Peter;Riebe, Oliver;Fischer, Carsten;Weinhold, Octavio;Dhom, Gunter;Sader, Robert;Weigl, Paul
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권5호
    • /
    • pp.273-284
    • /
    • 2022
  • PURPOSE. Computer-aided design and manufacturing (CAD-CAM) of implant abutments has been shown to result in surface contamination from site-specific milling and fabrication processes. If not removed, these contaminants can have a potentially adverse effect and may trigger inflammatory responses of the peri-implant tissues. The aim of the present study was to evaluate the bacterial disinfection and cleaning efficacy of ultrasonic reprocessing in approved disinfectants to reduce the microbial load of CAD-CAM abutments. MATERIALS AND METHODS. Four different types of custom implant abutments (total N = 32) with eight specimens in each test group (type I to IV) were CAD-CAM manufactured. In two separate contamination experiments, specimens were contaminated with heparinized sheep blood alone and with heparinized sheep blood and the test bacterium Enterococcus faecium. Abutments in the test group were processed according to a three-stage ultrasonic protocol and assessed qualitatively and quantitatively by determination of residual protein. Ultrasonicated specimens contaminated with sheep blood and E. faecium were additionally eluted and the dilutions were incubated on agar plates for seven days. The determined bacterial counts were expressed as colony-forming units (CFU). RESULTS. Ultrasonic reprocessing resulted in a substantial decrease in residual bacterial protein to less than 80 ㎍ and a reduction in microbiota of more than 7 log levels of CFU for all abutment types, exceeding the effect required for disinfection. CONCLUSION. A three-stage ultrasonic cleaning and disinfection protocol results in effective bacterial decontamination. The procedure is reproducible and complies with the standardized reprocessing and disinfection specifications for one- or two-piece CAD-CAM implant abutments.

유리앰플 주사제 개봉방법이 유리조각 혼입 및 약물오염에 미치는 영향 (Influence of Different Methods of Cutting Ampules on Drug Contamination by Glass Flakes from the Ampule)

  • 정현철;전미양
    • 기본간호학회지
    • /
    • 제16권2호
    • /
    • pp.207-213
    • /
    • 2009
  • Purpose: This study was done to examine how medication contamination in a single-dose glass ampule is affected by minute glass flakes generated in different methods of cutting the ampule. Method: Sixty medication-containing glass ampules were randomly assigned to two groups. The number of glass flakes, resulting from two different cutting methods (with cotton and without cotton), were counted under the microscope. Contamination was evaluated by extracted the medication with a syringe and culturing it in E. coli, coliform, and aerobic bacteria culture media. Result: Fewer glass flakes were found in the ampules when the ampule was cut with cotton. The use of cotton, however, did not significantly change the degree of drug contamination. Conclusion: Although minute glass flakes generated in the ampule cutting operation did not significantly contaminate the medication and the use of cotton decreased the number of glass flakes in the ampules, glass flakes injected into the blood and tissues of the patient remain a risk factor. Therefore, pre-filled syringes or syringes with filters would be alternative methods and safeguards against the possible injection of glass flakes generated while cutting the ampule.

  • PDF

서울 S지역에서 발생한 영아 메트헤모글로빈혈증 1례의 원인구명을 위한 역학조사 (Epidemiologic Investigation to Identify the Cause of an Infant Methemoglobinemia)

  • 김영열;최보율;박항배;김민영;여인학
    • Journal of Preventive Medicine and Public Health
    • /
    • 제26권2호
    • /
    • pp.192-201
    • /
    • 1993
  • Epidemiologic investigation was conducted on January, 1993 in Seoul to identify the cause of an infant methemoglobinemia. Field investigation of the area of outbreak, survey of household and family members, analysis of ground water, and blood tests of involved family members were performed. Following results were obtained On analyzing the quality of the ground water on patient's household high levels of nitrate was found indicating contamination of water as the cause of a methemoglobinemia outbreak. On analysing the quality of the ground waters on seven other places within the neighborhood five were contaminated by nitrate in concentration that exceeded the permissible limit implying presence nearby source of contamination. Sources of contamination were thought to be originating from human waste in conventional bathroom facilities, chicken manure used in nearby orchards and plant fields or fertilizers. But the results of water analysis with presence of bacteria or E.coli, concentration of potassium, phosphate and the past history of diarrhea among family members, chicken manure suggested the most possible source of contamination. To evaluate the health status of members in the neighborhood past history was reviewed revealing no prior existence of patient with cyanosis and 65 people in the neighborhood had normal levels of methemoglobin concentration in their blood. Conclusively, the ground water on patient's household was contaminated with nitrate and despite provision of adequate water supply, family members of the patient along with their distrust in the water supply system had used ground water as their source of drinking water resulting of methemoglobinemia. Many suburban area of Seoul and country side thought to be having similar problems concerning contaminated ground water supply and dormant outbreak of patients as a result of the drinking of the contaminated water. Epidemiologic investigation and water analysis of ground waters are advised.

  • PDF