• Title/Summary/Keyword: block hydraulic conductivity

Search Result 22, Processing Time 0.027 seconds

Study of Permeability of Bentonite Mixtured Soil (벤토나이트 혼합토의 투수성에 관한 연구)

  • Kim, Sung-Hwan;Oh, Young-In
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.805-812
    • /
    • 2009
  • Permeation water resulting in the reclaimed land of waste can possibly cause the second pollution, such as the underground water and environmental pollution. Accordingly, Liner layer has been installed in the reclaimed land of waste to block and purify permeation water and prevent this second pollution. The material used as Liner layer is the one for water resistance and that of less than permeability coefficient $1{\times}10^{-7}cm/sec$ is widely used. As it is very difficult to secure in bulk this natural clay with low permeability around the field, the suitable way to secure low permeable material is that we use blend with good watertighness by mixing it with natural soil which is spread in the site. While this mixed soil which can resist water is commonly used in the site, bentonite mixed soil which is widely used as Liner layer in the reclaimed land of waste is recognized in Liner and durability. In this study, the engineering characteristics of soil-bentonite mixed liner are investigated using the laboratory hydraulic conductivity and uni-axial strength tests. The soil used for the liner is the clay soil located near the site. Mixing ratio of the bentonite which satisfies the requirement of hydraulic conductivity is determined and the optimum mixing ratio of bentonite is recommended for the landfill. After the mixed liner is constructed using the optimum mixing ratio of bentonite, the block samples of the constructed liner are obtained and the strength tests were performed. The hydraulic and strength properties of the liner for construction of the waste landfill were both satisfactory.

  • PDF

Groundwater Flow Modeling in a Block-Scale Fractured Rocks considering the Fractured Zones (단열대의 영향을 고려한 블록 규모 단열 암반에서의 지하수 유동 모의)

  • Ko, Nak-Youl;Ji, Sung-Hoon;Koh, Yong-Kwon;Choi, Jon-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.2
    • /
    • pp.159-166
    • /
    • 2010
  • The block-scale groundwater flow system at Olkiluoto site in Finland was simulated. The heterogeneous and anisotropic hydraulic conductivity field for the domain was constructed from the discrete fracture network, which considered only the fractured zones identified in the deep boreholes installed in the study site. The groundwater flow model was calibrated by adjusting the recharge rate and the transmissivities of the fractured zones to fit the calculated hydraulic heads and into- and out-flow rates in the observation intervals of the boreholes with the observed ones. In the calibrated model, the calculated flow rates at some intervals were not in accordance with the observed ones although the calculated hydraulic heads fit well with the observed ones, which revealed that the number of the conduits for groundwater flow is insufficient in the conceptual model for groundwater flow modeling. Therefore, it was recommended that the potential local conduits such as background fractures should be added to the present conceptual model.

Effect of Joint Aperture Variation on Hydraulic Behavior of the 2-D DFN System (절리간극의 변화가 이차원 DFN 시스템의 수리적 특성에 미치는 영향)

  • Han, Jisu;Um, Jeong-Gi
    • Tunnel and Underground Space
    • /
    • v.26 no.4
    • /
    • pp.283-292
    • /
    • 2016
  • A computer program code was developed to estimate hydraulic behavior of the 2-D connected pipe network system, and implemented to evaluate the effect of joint aperture on hydraulic parameters of fractured rock masses through numerical experiments. A total of 216 stochastic 2-D DFN(discrete fracture network) blocks of $20m{\times}20m$ were prepared using two joint sets with fixed input parameters of joint orientation, frequency and size distribution. Two different cases of joint aperture variation are considered in this study. The hydraulic parameters were estimated for generated 2-D DFN blocks. The hydraulic anisotropy and the chance for equivalent continuum behavior of the DFN system were found to depend on the variability of joint aperture.

Dual-Porosity Models with Linear Flow Pattern (매트릭스 블록선형유동에 관한 이중공극 모델)

  • 함세영;성익환
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • This study deals with linear flow pattern in steady-state or transient dual-porosity media with a vertical geologic structure such as fault, fracture zone, etc. A pumping well is located in the vertical structure of infinitesimal or finite width with high hydraulic conductivity and negligible specific storage. Selected type curves on a pumping well and observation wells in the fractured system and the matrix block are provided. The type curves on the pumping well considers both wellhole and well-loss effects.

  • PDF

Multi-Region Model of Solute Transport in Soil for the Preferential Flow (Preferential 흐름에 의한 토양내의 다영역 용질이동 모델)

  • 안병기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.2
    • /
    • pp.71-77
    • /
    • 2000
  • A multi-region model for solute transport through saturated soils has been developed to describe preferential flow. The model consists of numerous discrete pore groups, which are characterized by a discrete dispersion coefficient, flow velocity, and porosity . The hydraulic properties for each pore group are derived from a soil's hydraluic conductivity and soil water characteristic functions . Flow in pore group is described by the classical advection-disersion equation (ADE). An implict finite difference scheme was applied to the governing equation that results in a block-tridiagonal system of equations that is very efficient and allows the soil to be divided into any number of pore groups. The numerical technique is derived from methods used to solve coupled equations in fluid dynamics problems and can also be applied to the transport of interacting solutes. The results of the model are compared to the experimental data from published papers. This paper contributes on the characteristics of the method when applied to the parallel porosity model to describe preferential flow of solutes in soil.

  • PDF

Effects of Soil Organic Amendment as Plant Growing Media Component for Restoration of Planting Ground (식재기반 복원을 위한 유기질계 토양개량재의 효용성)

  • Ju, Jin-Hee;In, Da-Young;Kim, Won-Tae;Yoon, Young-Han;Choi, Eun-Young
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1363-1370
    • /
    • 2015
  • This study was aimed to determine effects of soil organic amendment as plant growing media component on restoration of planting ground. The changes of soil physical and chemical properties and germination and growth of kentucky bluegrass (Poa pratensis L.) were investigated. For treatments, soil was excavated at depth of 0-50 cm (referred as $S_1$) and at depth of 50-100 cm (referred as $S_2$). Then the half amount of $S_1$ soil was mixed with the soil organic amendment (coir dust 40% (v/v), bottom ash 25%, leaf mold 25%, vermiculite 5%, carbonized rice hull 5%) at a rate of 6% (v/v) (referred as $S_1CC$) and also the half amount of $S_2$ soil was mixed with the soil organic amendment at a rate of 6% (v/v) (referred as $S_2CC$) on pot in a 16 cm diameter and 14 cm height. The experiment was replicated 3 times with 3 pots per replication in randomized block design, and 100 seeds were planted per pot. In results, there was no significant difference in soil pH among the treatments with a slight decrease in soil hydraulic conductivity. However, in the $S_1CC$ treatment, positive increases in soil chemical properties, including electrical conductivity, organic matter, phosphoric acid, total nitrogen, exchangeable cation, and cation exchange capacity. Also, the germination rate, plant height, and number of leaves were higher in the $S_1CC$ treatment than those in other treatments. These results suggest that the addition of organic amendment to the soil at depth of 0-50 cm might be proper for restoring planting ground.

Evaluation of Risk Factors to Detect Anomaly in Water Supply Networks Based on the PROMETHEE and ANP (상수도관망의 이상징후 판정을 위한 위험요소 평가 - PROMETHEE와 ANP 기법 중심으로)

  • Hong, Sung-Jun;Lee, Yong-Dae;Kim, Sheung-Kown;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.1 s.162
    • /
    • pp.35-46
    • /
    • 2006
  • In this study, we proposed a layout of the integrated decision support system in order to prevent the contamination and to manage risk in water supply networks for safe and smooth water supply. We evaluated the priority of risk factors to detect anomaly in water supply networks using PROMETHEE and ANP techniques, which are applied to various Multi-Criteria Decision Making area in Europe and America. To develop the model, we selected pH, residual chlorine concentration, discharge, hydraulic pressure, electrical conductivity, turbidity, block leakage and water temperature as the key data item. We also chose pipe corrosion, pipe burst and water pollution in pipe as the criteria and then we present the results of PROMETHEE and ANP analysis. The evaluation results of the priority of risk factors in water supply networks will provide basic data to establish a contingency plan for accidents so that we can establish the specific emergency response procedures.

In situ iron/manganese removal and permeability improvement at the river bank filtration site (강변여과수내 철망간 저감 및 투수성 개선)

  • Kim, Byung-Woo;Kim, Byung-Goon;Hur, Young-Teck;Kim, Dong-Sup;Kim, Hong-Suck
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.228-228
    • /
    • 2018
  • 강변여과는 지하수 인공함양 방식 중 유도함양(induced recharge) 또는 간접함양 방식에 속한다. 이는 하천 및 강변 부근에 집수시설을 설치한 후, 미고결층 대수층(unconsolidated aquifer)의 자연 오염 저감능을 이용하여 지표수를 간접 취수하는 방식으로 수질이 불량한 지표수가 대수층을 관류하면서 희석, 화학적 이온 교환 및 반응, 흡착, 생물막(biofilm; 미생물에 의한 자연저감), 여과 등을 통하여 수질이 개선된다. 강변여과수내의 용존 농도가 높은 철과 망간은 수처리 비용증가, 용수관정 및 시설물의 수명단축을 초래한다. 따라서 강변여과 지역의 미고결 대수층에서 효과적인 철과 망간 동시 제거(vyredox)를 위해 에어서징(air surging)과 블록 서징(block surging)을 실시하기 위해서 실내 물탱크 모델(water tank model)에서 에어서징에 따른 공기 순환 우물시스템을 관찰하였으며, 이를 바탕으로 현장시험(Test bed)에 적용하였다. 미고결 대층수층에서의 철 망간은 음용수 기준치(각각 0.3 mg/L)를 초과하고 있으며, 강변여과 취수 개발 및 이용을 제한하는 요인이 되고 있다. 본 연구에서 사용된 에어서징과 블록서지 기술은 자갈층 및 미고결 대수층에 충진된 슬라임 및 폐색(clogging)을 제거함과 동시에 관정 주변의 대수층의 투수성 개선과 산화환경으로 치환되며, 대수층에 잔존하는 철/망간의 산화물들을 관정내로 빼낼 수 있는 방법이다. 따라서 서징에 따른 폐색 제거효율을 검토한 결과에서 철 망간 이온농도 저감효과와 관정 주변의 수리전도도(hydraulic conductivity) 및 저류계수(coefficient of storage)가 증가한 것으로 나타났다. 이와 같이 강변여과에 의한 폐색은 미고결층내 공기주입 및 블록서지를 통하여 철/망간 이온농도 저감 및 수리특성 개선 효과에 유용한 것으로 평가된다.

  • PDF

Change of Hydraulic Characteristics due to Well Drilling and Well Development in an Unconsolidated Aquifer (미고결대수층에서 우물 굴착 및 개량에 의한 대수층의 수리특성 변화)

  • Kim, Byung-Woo;Kim, Gyoo-Bum;Kim, Geon-Young
    • The Journal of Engineering Geology
    • /
    • v.22 no.1
    • /
    • pp.27-37
    • /
    • 2012
  • To investigate the effect of aquifer disturbance on hydraulic properties while well drilling at unconsolidated aquifer, the following tests were conducted: the surge block and air-surging methods, which are well development methods used after well drilling; and step-drawdown tests and constant-rate pumping tests, which are used to assess changes in the aquifer after well drilling and development. The result of step-drawdown tests indicated that drawdown for a pumping-rate of $700m^3/day$ was 21.62 m after well development, decreasing 4.39 m from 26.01 m after well drilling. The skin factor used to identify the well properties decreased from 7.92 after well drilling to 5.04 after well development, respectively, which shows the improvement of well. Constant-rate pumping tests revealed a small increase in aquifer transmissivity after well development at MW-2, -3, and -4, centering around pumping well, from $1.684{\times}10^{-3}{\sim}4.490{\times}10^{-3}m^2/sec$ to $4.002{\times}10^{-3}{\sim}4.939{\times}10^{-3}m^2/sec$. MW-1, however, showed decline in hydraulic conductivity from $1.018{\times}10^{-2}m^2/sec$ to $6.988{\times}10^{-3}m^2/sec$, which was caused by a small decrease of aquifer permeability around monitoring well MW-1 due to latent factor of air interception and clogging in aquifer during surging. This finding indicates that fine particles have an effect on hydraulic properties at unconsolidated aquifers during well drilling; therefore, we consider that well drilling and development have an effect on hydraulic properties.

A Numerical Model for Analysis of Groundwater Flow with Heat Flow in Steady-State (열(熱)흐름을 동반(同伴)한 정상지하수(定常地下水)의 흐름해석(解析) 수치모형(數値模型))

  • Wang, Soo Kyun;Cho, Won Cheol;Lee, Won Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.4
    • /
    • pp.103-112
    • /
    • 1991
  • In this study, a numerical model was established and applied to simulate the steady-state groundwater and heat flow in an isotropic, heterogeneous, three dimensional aquifer system with uniform thermal properties and no change of state. This model was developed as an aid in screening large groundwater-flow systems as prospects for underground waste storage. Driving forces on the system are external hydrologic conditions of recharge from precipitation and fixed hydraulic head boundaries. Heat flux includes geothermal heat-flow, conduction to the land surface, advection from recharge, and advection to or from fixed-head boundaries. The model uses an iterative procedure that alternately solves the groundwater-flow and heat-flow equations, updating advective flux after solution of the groundwater-flow equation, and updating hydraulic conductivity after solution of the heat-flow equation. Dierect solution is used for each equation. Travel time is determined by particle tracking through the modeled space. Velocities within blocks are linear interpolations of velocities at block faces. Applying this model to the groundwater-flow system located in Jigyung-ri. Songla-myun, Youngil-gun. Kyungsangbuk-do, the groundwater-flow system including distribution of head, temperature and travel time and flow line, is analyzed.

  • PDF