• Title/Summary/Keyword: bituminous coal

Search Result 211, Processing Time 0.028 seconds

Characteristics of Co-Combustion of Korean Anthracite with Bituminous Coal in a Circulating Fluidized Bed (순환유동층에서 유.무연탄 혼소 특성)

  • Lee, J.M.;Kim, J.S.;Lee, E.M.
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.3
    • /
    • pp.1-9
    • /
    • 2005
  • The characteristics of co-combustion of Korean anthracite and bituminous coal was determined in a TGA and a lab-scale CFB reactor. The combustion reactivity of Korean anthracite (E = 51.2 kcal/mol) was much lower than that of bituminous coal (E = 14.5 kcal/mol). As the addition amount of the bituminous coal into the anthracite was increased, the reactivity of the anthracite was found to be improved. The effluent rate of the emission gases from the CFB reactor was not changed appreciably when each coal burned. As the bituminous coal was added, however, the effluent rate of the emissions was increased. The unburned carbon in fly ash from the CFB reactor was decreased with increasing the ratio of bituminous coal in co-combustion. But as the ratio of the bituminous coal was larger than 40 %, the combustion reactivity was not increased any more.

  • PDF

Ignition Behavior of Single Coal Particles From Different Coal Ranks at High Heating Rate Condition

  • Lee, Dongfang;Kim, Ryang Gyoon;Jeon, Chung-Hwan
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.111-114
    • /
    • 2012
  • The ignition behavior of single coal particles of five kindes of coal with different ranks (low volatile bituminous, low volatile sub-bituminous, high volatile bituminous, lignite) with particle size of $150-200{\mu}m$ was investigated at high heating rate condition. Particles were injected into a laminar flow reactor and the ignition behavior was observed with high speed cinematography. Sub-bituminous were observed to ignite homogeneously; however, low volatile bituminous coal and lignite undergo fragmentation prior to igntion. The observation was analyzed with previous work.

  • PDF

Dynamic response of coal and rocks under high strain rate

  • Zhou, Jingxuan;Zhu, Chuanjie;Ren, Jie;Lu, Ximiao;Ma, Cong;Li, Ziye
    • Geomechanics and Engineering
    • /
    • v.29 no.4
    • /
    • pp.451-461
    • /
    • 2022
  • The roadways surrounded by rock and coal will lose their stability or even collapse under rock burst. Rock burst mainly involves an evolution of dynamic loading which behaves quite differently from static or quasi-static loading. To compare the dynamic response of coal and rocks with different static strengths, three different rocks and bituminous coal were selected for testing at three different dynamic loadings. It's found that the dynamic compression strength of rocks and bituminous coal is much greater than the static compression strength. The dynamic compression strength and dynamic increase factor of the rocks both increase linearly with the increase of the strain rate, while those of the bituminous coal are irregular due to the characteristics of multi-fracture and heterogeneity. Moreover, the absorbed energy of the rocks and bituminous coal both increase linearly with an increase in the strain rate. And the ratio of absorbed energy to the total energy of bituminous coal is greater than that of rocks. With the increase of dynamic loading, the failure degree of the sample increases, with the increase of the static compressive strength, the damage degree also increases. The static compassion strength of the bituminous coal is lower than that of rocks, so the number of small-scale fragments was the largest after bituminous coal rupture.

Comparison Study for Domestic Coal and Material Characteristics of Coal from the Shipwreck of Koryo Dynasty (고려시대 선체출토 석탄의 재료학적 특성 및 국산 석탄과의 비교 연구)

  • Lee, JangJon;Park, SukWhan;Lim, SungTae;Han, MinSu
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.345-354
    • /
    • 2013
  • This study analyses geochemistrical, microscopic, mineralogical characteristics of coals which have been collected from in and out of the shipwreck No 1 of Mado island during underwater excavation in Taean. The result from mineralogical and geochemical analysis reveals that the specific gravity of the coals is $1.28g/cm^3$. Considering that coals contains 10% mineral of it and the specific gravity of the pure is $1.15g/cm^3$, it is believed that the collected coals would be lignite or biturminous coal. The X-ray diffraction analysis which displays the peak of $2{\theta}$ is 20~25C degree, proves that the collected coals would be categorised as low rank coal. The collected coals is composed of: 93%-94%(93.5%) of vitrinite maceral group, 5%-6%(5.5%) of exinite maceral group, and 1% of inertinite maceral group. In addition, the average of reflection rate is $R_{mean}$: 0.627 showing that it would be either high volatile bituminous C coal or sub-bituminous C coal. Such result confirms that the coal is sub-bituminous C or high volatile bituminous C coal in accordance with the U.S Bureau of Mine(USBM) classification system. The element analysis reveals that the coal is the coking coal which is grouped as the bituminous coal. Comparative analysis between the coals of Mado Shipwreck No 1 and domestic coals shows that the coals of Mado Shipwreck is similar to the bituminous coal used in the area of Janggi in Pohang city.

Co-combustion Characteristics of Mixed Coal with Anthracite and Bituminous in a Circulating Fluidized Bed Boiler (순환유동층 보일러에서 무연탄-유연탄의 혼합연소 특성)

  • Jeong, Eui-Dae;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.6 no.2
    • /
    • pp.70-77
    • /
    • 2010
  • This study investigated the characteristics of co-combustion of mixed anthracite (domestic and Vietnam) and bituminous coal (Sonoma, Australia) at circulating fluidized bed boiler in Donghae thermal power plant when mixing ratio of bituminous coal is variable. Co-combustion of bituminous coal contributes to improvement in general combustion characteristics such as moderately retaining temperature of furnace and recycle loop, reducing unburned carbon powder, and reducing discharge concentration of NOx and limestone supply owing to improvement in anthracite combustibility as the mixing ratio was increased. However, bed materials were needed to be added externally when the mixing ratio exceeded 40% because of reduction in generating bed materials based on reduction in ash production. When co-combustion was conducted in the section of 40 to 60% in the mixing ratio while the supplied particles of bituminous coal was increased from 6 mm to 10 mm, continuous operation was shown to be possible with upper differential pressure of 100 mmH2O (0.98 kPa) and more without addition of bed materials for the co-combustion of mixed anthracite and bituminous coal (to 50% or less of the ratio) and that of domestic coal and bituminous coal (to 60% of the ratio).

  • PDF

Emission Characteristics of PM and PM2.5 from Bituminous Coal Combustion Power Plants (유연탄 발전소에서의 PM 및 PM2.5 배출특성)

  • Yoon, Young-Sik;Kim, Jeong-Hun;Pudasainee, Deepak;Son, Seung-Uk;Park, Gwang-Kyu;Park, Kyoung-Il;Seo, Yong-Chil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.151-160
    • /
    • 2010
  • Particles emitted from three coal-fired power plants burning bituminous and sub-bituminous coals were examined for PM and size fractions PM>2.5 and PM2.5. The ratio of PM2.5/PM was ranged from 10 to 62%, and PM emission increased with the amount of coal feed, which was 7.23~15.66 kg/h. The emission range of PM2.5 from three power plants was 1.24~4.48 kg/h (dry), which was function of the mixed rate of viscous sub-bituminous coal in feed. Of course such effect should be examined by further tests in details. Based on the consumed coal and thermal load, the emission factors averaged were shown as 59.03 g-PM/ton-coal, 14.79 g-PM2.5/ton-coal and 22.51 g-PM/MWh, 5.54 g-PM2.5/MWh, respectively.

The Effect of Multi-Coal Combustion on the Generation of Slagging in a Bituminous Coal-fired Power Plant Boiler (연탄 화력발전소 보일러에서 다탄종 연소가 슬래깅 발생에 미치는 영향)

  • Park, Jihoon;Yoo, Hoseon
    • Plant Journal
    • /
    • v.18 no.1
    • /
    • pp.55-61
    • /
    • 2022
  • In this study, I analyzed the effect of slagging caused by blending bituminous coal and subbituminous coal while maintaining the generator output, combustion conditions, and ventilation conditions for 870MW thermal power plant designed with bituminous coal. Accordingly I proposed an acceptable method of blending coal method. the blending ratio of sub-bituminous coal was adjusted to 10%, 20%, 40%, 60%, 80%, etc. to confirm ultimate analysis, proximate analysis, ash fusion temperature change, slagging indices, etc. Proper blending coal conditions are blending with sub-bituminous coal at 40% or less, ratio of base component to acid component(B/A) is 0.4 or less or 1 or more, total alkali(TA) is 3.5 or less, fusion slagging index(Rfs) is 1,345℃ or more, and ash content is 13% or less in ultimate analysis, the ash content in proximate analysis is 15% or less, and the initial deformation temperature(IDT) should be at least 1,200℃ or more

  • PDF

Investigation of Tar/soot Yield of Bituminous and Low Rank Coal Blends (발전용 역청탄과 저열량탄 혼소시 Tar/Soot의 배출 특성 연구)

  • Lee, Byung Hwa;Kim, Jin Ho;Kim, Gyu Bo;Kim, Seng Mo;Jeon, Chung Hwan
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • Soot and tar which were derived from combustion or pyrolysis processes in Puverized Coal(PC) furnace or boiler have been significantly dealing in a radiative heat transfer and an additional source of NOx. Furthermore, the increasing for the use of a coal with low caloric value gives rise to a lot of tar-soot yield and LOI in a recycled ash for using cement materials. So, the ash with higher tar-soot yield and LOI can not recycle due to decreased strength of concrete. In this study, tar-soot yields and flame structures were investigated using the LFR for a blending combustion with bituminous coal and sub-bituminous coal. Also, The investigation were conducted as each single coals and blending ratio. The coals are used in a doestic power plant. In the experimental results, sub-bituminous coal with high volatile contents shows longer soot cloud length than bituminous coal, but overall flame length was shorter than bituminous coal. Tar-soot yields of sub-bituminous coal is lower than those of bituminous coal. Combustion characteristics are different between single coal and blended coal. Therefore, finding an optimal coal blending ratio according to coal rank effects on tar-soot yields.

역청탄과 아역청탄의 석탄가스환 및 IGCC 성능검토

  • 안달홍;나중희;송규소;김남호;김종진;지평삼
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.68-77
    • /
    • 1994
  • The Integrated Gasification Combined Cycle(IGCC) power plant is one of Clean Coal Technology to meet the demand for clean and efficient electric power for the 21st century. This study is to investigate the impacts of changes in coal quality to the performances of gasification processes and IGCC plants. The selection of the most economic coal is an important attribute for the IGCC power generation technology. The performances of gasification processes was predicted, and compared with the results of Shell coal gasification demonstrantions. The IGCC performances with bituminous and sub-bituminous coal were predicted as well. It is obtained that the bituminous coal is superior to the sub-bituminous coal for IGCC power generation.

  • PDF

Engineering Control of Mill Fire for High Volatile Sub-bituminous Coal (저급탄 미분기 화재발생 인자분석 연구)

  • Keel, Sang-In;Park, Ho-Young;Kim, Young-Joo;Youn, Sung-Hwan
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • Lots of Coal power plants (about 30) using bituminous coals are being run in Korea. The use of high volatile low grade sub-bituminous coal is increasingly extended because of imbalance between the worldwide coal supply and demand. Mill-fire has been an important issue since the use of such sub-bituminous coal. In existing coal plants of Korea, shutdown of coal and air supplies could be only a way, and an alternative has not been found in suppressing the mill fire. The inside fowfield in the mills has a highly fuel-rich, low temperature, and high velocity and non-reactive such that it could be a nonreactive system essentially. Nevertheless, occasional fire-occurrence could be attributed to the existence of an ignition source. However it has not been so far investigated in detail. The current work has a focus on suppressing the mile fire via some parametric experimental study such as effects of temperature, residence time, ignition source, and inert gas mixing. The results show that an small amount of $CO_2$- or $N_2$-mixing with air is very effective in suppressing fire formation even at high temperatures or flying sparks. The results suggest that exhaust gas recirculation into the mill should be an alternative to suppress mill fire.