• Title/Summary/Keyword: biopsy

Search Result 2,939, Processing Time 0.029 seconds

Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy (유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성)

  • Choi, Miseon;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • Social interest in breast cancer has increased. The most basic exams for diagnosis include breast X-ray and breast ultrasound. In particular, breast microcalcification requires histological diagnosis, and breast microcalcification biopsy is commonly performed. Therefore, this study aimed to analyze and assess X-ray guided biopsy (needle localized open biopsy) and ultrasound guided biopsy (sono guided core needle biopsy), which are basics in diagnosis of microcalcification. Targeting 241 cases in which magnification mammography was performed for patients who visited the hospital due to breast microcalcification, age distribution and the location of lesions were analyzed in X-ray guided biopsy and ultrasound guided biopsy. By classifying exams performed after magnification mammography, the frequencies of X-ray guided biopsy and ultrasound guided biopsy were analyzed, and malignant and benign results were confirmed. The results showed that 64 cases(26.6%) were X-ray guided biopsy, which was 5.4 times higher than 12 cases(4.9%) of ultrasound guided biopsy. Due to development of ultrasound equipments, stereotactic vacuum-assisted biopsy, etc. the methods of histological diagnosis of microcalcification have become diverse, but when considering characteristics and limitations of each exam, X-ray guided biopsy is thought to be most accurate and useful.

clinical evaluation of pleural biopsy by cope needle (Cope씨 침을 이용한 늑막 생검에 관한 임상적 고찰)

  • 황윤호
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.374-380
    • /
    • 1986
  • From June 1983 to September 1984, the pleural biopsies with Cope needle were performed at department of thoracic and cardiovascular surgery, Pusan Paik Hospital, Inje college, on 78 patients for exudative pleural effusion caused by various conditions. These results were analyzed clinically and summarized as follows: 2. The accuracy of pleural biopsy was 69.2% [54 of 78 patients]. The accuracy represented by ratio for the number of biopsy was 63.5% [54 of 85 biopsies]. 3. Among 61 patients of tuberculosis or malignancy, 37 [60.7%] were confirmed by pleural biopsy. 4. Tuberculosis was diagnosed in 48 patients, in 26[54.2%] out of these by pleural biopsy alone, in 3[6.2%] by pleural biopsy and isolation of AFB, in 2[4.2%] by pleural biopsy and operation, in 4[8.3%] by isolation of AFB, in 2[4.2%] by operation, and in 11[22.9%] clinically. 5. Among 13 patients of malignancy, 4[30.8%] were diagnosed by cytology alone, 4[30.8%] by pleural biopsy and cytology alone, 4[30.8%] by pleural biopsy and cytology, 1[7.7%] by pleural biopsy alone, 1[7.7%] by pleural biopsy and operation, and remained 3 by operation, lymph node biopsy, or bronchoscopy respectively. 6. False positive of clinical diagnosis was 12.5% for tuberculosis and 28.6% for malignancy. In pathological diagnosis there was no false positive. So specificity of pleural biopsy was very high. But false negative of pleural biopsy was 29.2% for tuberculosis and 46.2% for malignancy. 7. 4 cases[5.1%] of minimal pneumothorax were in the early series.

  • PDF

Open Lung Biopsy for Diffuse Infiltrative Lung Disease (미만성 폐질환에 대한 폐생검의 의의)

  • 김해균
    • Journal of Chest Surgery
    • /
    • v.24 no.9
    • /
    • pp.903-906
    • /
    • 1991
  • Retrospective review of 26 patients undergoing open lung biopsy at the Yonsei University during 10 years period was conducted to evaluate open lung biopsy for DILD. From January 1980 to August 1990, open lung biopsy was performed in 26 patients through a limited thoracotomy incision[a limited anterior or a posterolateral thoracotomy]. Open lung biopsy was indicated for diffuse interstitial pulmonary diseases undiagnosed by indirect clinical and radiological diagnostic methods. The types of incision were limited anterior[11] and limited posterolateral[15]. Preoperative evaluation of the lung disease included sputum culture[26], sputum cytology [19], bronchoscopy[9] and TBLB[7]. In 23 patients the histologic appearances after open lung biopsy were sufficiently specific histologic pictures to confirm diagnosis. The results of the biopsies changed usual therapeutic plan in 17 patients among them. The complications were resp. insufficiency[3], pulmonary ed6ma[3], sepsis[2], and others[3] in 6 patients. Diagnosis from the open lung biopsy was included respiratory pneumonia[7], fibrosis[7], infection[5], malignancy[2], others[5]. 4 patients died of respiratory insufficiency. The causes of the other three death were not due to direct result of the biopsy itself. Open lung biopsy in the patient with a diffuse infiltrative lung disease is an one of the accurate diagnostic method and frequently leads to change of the therapeutic plans. So we conclude that open lung biopsy remains our diagnostic method of choice in diffuse infiltrative lung disease undetermined etiology.

  • PDF

Robotized Percutaneous Biopsy (로봇을 이용한 경피 생체 검사)

  • Son, Jaebum;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.105-113
    • /
    • 2012
  • Biopsy is a type of histopathological examinations, in which a physician samples cells or tissues from a patient's suspicious lesion. Such a lesion frequently resides deep inside human body, and then a percutaneous biopsy is therefore performed using a thick needle with the assistance of medical imaging such as computed tomography(CT) and magnetic resonance imaging(MRI). Recently modern robotic technology is being introduced to percutaneous biopsy in order to reduce any possible human error and hazard on physicians caused by medical imaging. After medical imaging locates the exact location of lesion, an optimization algorithm plans the path for a biopsy needle. Subsequently, a robot system moves the biopsy needle to the lesion in accurate and safe way with the control of a practitioner or automatically. In this article, we try to look into the state-of-art of percutaneous biopsy using such robotic technology. We classified percutaneous biopsy robots by mechanical characteristics and by imaging technology. Then, advantage and disadvantage of each class type are described as well as the basic description, and a few representative designs for each type are introduced. Current research issues of robotized percutaneous biopsy are subjectively selected for the readers' convenience. We emphasize the basic technology of actuator and sensors compatible with imaging technology to conclude this review.

Transthoracic Needle Biopsy of Thoracic Lesions (흉부 병터에 대한 경흉부 바늘생검)

  • Song, Jae-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.3
    • /
    • pp.241-247
    • /
    • 2004
  • In the diagnostic evaluation of thoracic lesions, the image-guided transthoracic needle biopsy was developed, and its role was expanded with the development of cross-sectional detection and characterization of thoracic lesions and advances in biopsy needle design and techniques. Particularly for diagnostic evaluation of solitary pulmonary nodules, transthoracic needle biopsy has emerged as the invasive procedure of choice. This article covers the indication, the pre-procedure preparation, various guidance-modalities and techniques, and complications.

Open Lung Biopsy for Diffuse Infiltrative Disease of the Lung (미만성 침윤성 폐질환에 대한 폐 생검의 의의)

  • 김병호
    • Journal of Chest Surgery
    • /
    • v.28 no.2
    • /
    • pp.162-165
    • /
    • 1995
  • To evaluate the impact of open lung biopsy on diagnosis and treatment of diffuse infiltrative lung disease, we conducted a retrospective review of 28 patients who underwent this procedure at the Kyoungpook National University Hospital from 1986 to 1993. There were 19 men and 9 women; average age was 50.9 years. During open lung biopsy, The region of the lobe was radiographically and grossly identified and was examined by a biopsy. The biopsy yielded a specific diagnosis in 27 [96.4 % patients and changes in therapy in 24[85.7% patients. Complications developed in three[10.8% patients, directly related to the biopsy procedure in 2. One patient died[3.6% due to underlying disease. We conclude that open lung biopsy can be accomplished safely in the patient with diffuse infiltrative lung disease and it is an important tool in decision-making process and therapy.

  • PDF

Comparison between Transthoracic Fine Needle Aspiration Cytology and Gun Biopsy of Pulmonary Mass (폐종괴에 대한 경피적 세침흡인세포검사와 자동총부착 침생검의 비교)

  • Nam, Eun-Sook;Kim, Duck-Hwan;Shin, Hyung-Sik
    • The Korean Journal of Cytopathology
    • /
    • v.9 no.1
    • /
    • pp.55-61
    • /
    • 1998
  • To compare the diagnostic yields and complication rates of transthoracic fine needle aspiration cytology(FNAC) and gun biopsy in the diagnosis of pulmonary mass, a retrospective review was performed in 125 cases. Under the fluoroscopic guide, FNAC was performed by 20G Chiba needle in 91 cases, core biopsy was done by 18.5 G vaccum needle attached with automated biopsy gun in 74 cases and both procedures were done together in 37 cases. Overall sensitivity was 88.4% in FNAC and 87.5% in gun biopsy. For malignant pulmonary tumors, correct type correlation with final diagnosis was obtained in 33(76.7%) out of 43 cases by FNAC and 30(75.0%) out of 40 cases by gun biopsy. For benign pulmonary lesions, there were correct type correlation in 14(35.0%) out of 40 cases by FNAC and 14(53.8%) out of 26 cases by gun biopsy. The complication was pneumothorax and hemoptysis. Pneumothorax occured in 11.1% of FNAC, 10.9% of gun biopsy and 10.9% of both technique, among which chest tube drainages were necessary in one patient by gun biopsy and in three patients by both technique. Although no significant difference of diagnositc accuracy and complication rate was found between FNAC and gun biopsy, gun biopsy was more helpful in the diagnosis of pulmonary benign lesions than FNAC.

  • PDF

Open Lung Biopsy Procedure for Diffuse Infiltrative Lung Disease -Collective Review of 50 Cases- (미만성 폐침윤 질환에서 개흉폐생검)

  • 이해영
    • Journal of Chest Surgery
    • /
    • v.28 no.1
    • /
    • pp.53-58
    • /
    • 1995
  • Open lung biopsy still has important roles for the marking of diagnosis of diffuse infiltrative lung disease even though transbronchial bronchoscopic lung biopsy and percutaneous needle aspiration biopsy gain popularity nowadays. This is clinical retrospective review of the 56 patients with diffuse infiltrative lung disease undergoing open lung biopsy by minithoracotomy from 1984 to Dec. 1992 in the Department of Thoracic & Cardiovascular Surgery of Catholic University Medical College. 27 men and 29 women, aged 17 to 73 year [mean 49 year , were enrolled & divided into 2 groups;Group A consisted of patients with immunocompromised state [n=19 , Group B patients with non-immunocompromised state[n=38 . Pathologic diagnosis was made in 54 cases[96.4% of these two groups and as follows: infectious; 12 patients[21.4% , Neoplastic; 10 patients[17.9% , granulomatous; 4 patients[7.1% , interstitial pneumonia; 12 patients[21.4% , Pulmonary fibrosis; 8 patients[14.3% , others; 3 patients[5.4% , nonspecific; 5 patients[8.9% , and undetermined; 2 patients[3.6% . Therapeutic plans were changed in 39 patients[69.6% after taking of tissue diagnosis by open lung biopsy. Group B has higher incidence of infectious diseases and change of therapeutic plan than the Group A. The postoperative complications developed in 8 cases[14.3% ,and there is no difference of incidence between the 2 groups. 4 patients belongs to group A, died of respiratory distress syndrome [2 and sepsis [2 which were not related with open lung biopsy procedure. In conclusion, open lung biopsy is a reliable method to obtain a diagnosis in diffuse pulmonary infiltrates and can be performed safely, even in acutely ill, immunosuppressed patients.

  • PDF

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

A Study on Sandbag Management, vital sign, Pain and Hemorrhage after Kidney Biopsy in Children with Nephrotic Syndrome (신장증 환아의 신생검후 모래주머니 적용시간에 따른 활력징후, 통증 및 출혈에 관한 연구)

  • Cho Kyoul-Ja;Paik Seung-Nam;Park Soon-Hee
    • Child Health Nursing Research
    • /
    • v.9 no.1
    • /
    • pp.28-35
    • /
    • 2003
  • Purpose: The purpose of this study is to investigate correlations in vital sign changes, the severity of pain, signs of complications, and the duration of sandbag management in order to suggest a standardized practice related to sandbag management in children with Nephrotic Syndrome(NS). Method: From October 2000 to May 2001, seventy children with NS who underwent kidney biopsy were interviewed at one hospital in Seoul Korea, and participated in this study. Result: 1) The average sandbag applying time after kidney biopsy was 18.1 hours. 2) Systolic blood pressure and respiration increased until 15 minutes after kidney biopsy, after then, they decreased signifi- cantly (systolic BP, p= .006; respiration, p= .029). However, no significant changes were noted in diastolic blood pressure and pulse. 3) Pain was reported minimal for 1 hour after kidney biopsy. The severity of pain increased until 12 hours after the procedure, then, decreased significantly(p= .0001). 4) Reported complications were hematuria (74.7%) and abnormal sonogram (32.9%). No apparent bleeding on the biopsy region was reported in any children. Conclusion: From these findings, it is possible to change the protocols of the duration of absolute bed rest time and sandbag application management shortly after kidney biopsy. But it is needed to study the fit protocols for kidney biopsy. Several implications in nursing practice are suggested. 1) Replicated studies for more participants are needed. 2) Further research on the effect of sandbag application after kidney biopsy is required. 3) The best duration of sandbag application management after kidney biopsy need to be investigated.

  • PDF