• 제목/요약/키워드: biological stability

검색결과 838건 처리시간 0.029초

Effect of Glutaraldehyde Treatment on Stability of Permeabilized Ochrobactrum anthropi SY509 in Nitrate Removal

  • Park, Young-Tae;Park, Jae-Yeon;Park, Kyung-Moon;Choi, Suk-Soon;Yoo, Young-Je
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권11호
    • /
    • pp.1803-1808
    • /
    • 2008
  • For practical application, the stability of permeabilized Ochrobactrum anthropi SY509 needs to be increased, as its half-life of enzymatic denitrification is only 90 days. As the cells become viable after permeabilization treatment, this can cause decreased activity in a long-term operation and induce breakage of the immobilization matrix. However, the organic solvent concentration causing zero cell viability was 50%, which is too high for industrial application. Thus, whole-cell immobilization using glutaraldehyde was performed, and 0.1% (v/v) glutaraldehyde was determined as the optimum concentration to maintain activity and increase the half-life. It was also found that 0.1% (v/v) glutaraldehyde reacted with 41.9% of the total amine residues on the surface of the cells during the treatment. As a result, the half-life of the permeabilized cells was increased from 90 to 210 days by glutaraldehyde treatment after permeabilization, and no cell viability was detected.

고안전성 리튬이차전지 구현을 위한 나노 세라믹 코팅 분리막 제조 및 전기화학특성 분석 (Nano Ceramic Coating on Polypropylene Separator for Safety-Enhanced Lithium Secondary Battery)

  • 이정모;전현규;한태영;유명현;이용민
    • 전기화학회지
    • /
    • 제20권2호
    • /
    • pp.41-48
    • /
    • 2017
  • 폴리올레핀 분리막의 내열성을 향상시키면서도 전기화학특성 개선을 위해 RF Magnetron Sputter기반으로 수십 나노미터 수준의 세라믹 층이 코팅된 내열 분리막을 제조하였다. 분리막 원단의 열적 손상없이 코팅 시간을 최소화하기 위한 증착 조건을 최적화 하였고, 이를 기반으로 제조된 내열 분리막의 물리적, 전기화학적 평가를 진행하였다. 약 20 nm의 $Al_2O_3$가 코팅된 Polypropylene(PP) 분리막은 원단 분리막 대비 통기 특성 (원단: 211.3 sec/100 mL, 코팅 분리막: 250.8 sec/100 mL)은 떨어졌으나, 열 수축율 (원단: 19.4%, 코팅 분리막: 0.0% @ $140^{\circ}C$ & 30 min), 전해액 Uptake(원단: 176%, 코팅 분리막: 190%) 및 이온전도도 (원단: 0.700 mS/cm, 코팅 분리막: 0.877 mS/cm)는 모두 향상되었다. 그 결과, 2032-type Half-cell($LiMn_2O_4/Li$)을 이용한 전기화학적 평가에서도, 향상된 율별 특성과 유사한 수명 특성을 나타내었다.

The Corrosion Study of Al Current Collector in Phosphonium Ionic Liquid as Solvent for Lithium Ion Battery

  • Cha, Eun-Hee;Mun, Jun-Young;Cho, E.-Rang;Yim, Tae-Eun;Kim, Young-Gyu;Oh, Seung-M.;Lim, Soo-A;Lim, Jea-Wook
    • 전기화학회지
    • /
    • 제14권3호
    • /
    • pp.152-156
    • /
    • 2011
  • A room temperature ionic liquid (RTIL) based on trihexyl (tetradecyl)phosphonium bis(trifluoromethanesulfonyl) imide ([$(C_6H_{13})_3P(C_{14}H_{29)}$] [TFSI];P66614TFSI) was synthesized and analyzed to determine their characteristics and properties. The bis(trifluoromethanesulfonyl)imide (TFSI) anion is widely studied as an ionic liquid (IL) forming anion which imparts many useful properties, notably electrochemical stability. Especially its electrochemical and physical characteristics for solvent of lithium ion battery were investigated in detail. $P_{66614}$ TFSI exhibits fairly low conductivity (0.89 mS $cm^{-1}$) and higher viscosity (298 K: 277 cP; 343 K: 39 cP) than other ionic liquids, but it exhibits a high thermal stability (over $400^{\circ}C$). Especially corrosion behavior on Al current collector was tested at room temperature and further it was confirmed that thermal resistivity for Al corrosion was highly increased in 1.0M LiTFSI/$P_{66614}$-TFSI electrolyte comparing with other RTILs by linear sweep thermometry.

분리 대두 단백질의 유화 안정성에 관한 인산염의 영향 (Effect of phosphate salts on the emulsion stability of soy protein isolate)

  • 황재관;김영숙;변유량
    • Applied Biological Chemistry
    • /
    • 제35권3호
    • /
    • pp.152-156
    • /
    • 1992
  • 분리 대두 단백질의 유화 안정성에 관한 인산 염 $(Na_2HPO_4,\;K_2HPO_4)$의 농도와 첨가방법의 영향을 연구 하였다. 유화 과정 이전에 인산염을 첨가하였을 경우 10mM의 농도에서 유화 안정성이 증가하였으나, 유화 과정 이후에 첨가한 경우에는 유화 안정성이 감소하였다. 반면에 높은 인산 염 농도에서는 첨가 방법에 관계없이 유화 안정성이 감소하였다. 한편 분리대두 단백질의 등전점(pH 4.5)이나 $CaCl_2$의 존재 하에서 인산염을 첨가한 경우 유화 안정성은 크게 증가 하였으며, 이 때 전체적인 유화 안정성은 분리 대두 단백질의 용해도와 유사한 경향을 보였다. 이는 분리 대두 단백질의 유화 안정성은 그 용해도와 밀접한 관계가 있다는 것을 의미한다.

  • PDF

리포솜 내의 콜레스테롤 함량이 Ascorbic Acid의 안정성에 미치는 영향 (Effect of Cholesterol in Liposome on the Stabilization of Encapsulated Ascorbic Acid)

  • 임채환;이유원;이상천;이승철
    • Applied Biological Chemistry
    • /
    • 제42권3호
    • /
    • pp.205-209
    • /
    • 1999
  • 리포솜을 구성하는 지질 내의 콜레스테롤 함량이 포집된 ascorbic acid의 안정성에 미치는 영향을 조사하였다. 리포솜 내에서의 콜레스테롤 함량이 증가할수록 탈수화/재수화법으로 제조된 리포솜의 크기는 증가하였으며, 가해진 ascorbic acid의 안정성은 증대되었으며, 외부의 pH 영향을 크게 받지 않았다. 그러나, $4^{\circ}C$에서 저장한 경우에 비하여 $37^{\circ}C$에서 저장한 경우에는 포집된 ascorbic acid의 산화가 빨리 진행되었다. 이러한 결과는 리포솜의 콜레스테롤 함량이 포집된 ascorbic acid의 안정성에 영향을 미침을 의미한다.

  • PDF

Ionic Liquid as a Solvent and the Long-Term Separation Performance in a Polymer/Silver Salt Complex Membrane

  • Kang, Sang-Wook;Char, Kook-Heon;Kim, Jong-Hak;Kang, Yong-Soo
    • Macromolecular Research
    • /
    • 제15권2호
    • /
    • pp.167-172
    • /
    • 2007
  • The reduction behavior of silver ions to silver nanoparticles is an important topic in polymer/silver salt complex membranes to facilitate olefin transport, as this has a significant effect on the long-term performance stability of the membrane. In this study, the effects ofthe solvent type on the formation of silver nanoparticles, as well as the long-term membrane performance of a solid polymer/silver salt complex membrane were investigated. These effects were assessed for solid complexes of poly(N-vinyl pyrrolidone) $(PVP)/AgBF_4$, using either an ionic liquid (IL), acetonitrile (ACN) or water as the solvent for the membrane preparation. The membrane performance test showed that long-term stability was strongly dependent on the solvent type, which increased in the following order: IL > ACN >> water. The formation of silver nanoparticles was more favorable with the solvent type in the reverse order, as supported by UV-visible spectroscopy. The poor stability of the $(PVP)/AgBF_4$ membrane when water was used as the solvent might have been due to the small amount of water present in the silver-polymer complex membranes actively participating in the reduction reaction of the silver ions into silver nanoparticles. Conversely, the higher stability of the $(PVP)/AgBF_4$, membrane when an IL was used as the solvent was attributable to the cooperative coordination of silver ions with the IL, as well as with the polymer matrix, as confirmed by FTIR spectroscopy.

목재의 치수안정성과 내후성 개선을 위한 열처리 가공에 관한 연구 동향 (Research Trend of The Heat-Treatment of Wood for Improvement of Dimensional Stability and Resistance to Biological Degradation)

  • 김영숙
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권3호
    • /
    • pp.457-476
    • /
    • 2016
  • 본 연구에서는 목재의 열처리가공에 대하여, 문헌 연구를 통하여 이와 관련된 주요 이슈 및 기술 동향을 조사하였다. 산업적으로 이용되는 주요 열처리기술은 네덜란드의 Plato-process, 프랑스의 Retification process, 독일의 OHT-process, 및 핀란드의 Thermowood process 등이었다. 열처리 공정상의 주요 영향인자들은 대상 수종, 가열 온도, 시간, 열전달 매질(air, 증기, 진공, 질소, 오일 등)이며, 이들 인자들을 변수로 한 최적조건 탐색 등의 연구가 주류를 이룬다. 열처리 목재는 치수안정성 증가, 중량 및 강도 감소, 부후균에 대한 내후성 향상에 변이, 변색균 및 해충에 대해 불충분한 저항성 등의 특징을 가진다. 열처리 목재의 내후성 향상을 위해 각 수종에 적합한 열처리 공정과 처리조건 탐색의 필요성이 시사되었다. 지속가능한 환경보존 및 목재자원 절약을 위해 열처리 목재의 새로운 용도 개발 및 이용 확대 노력이 반드시 필요한 과제인 것으로 고찰되었다.

매립폐기물의 호기성 안정화 평가를 위한 AT4 실험의 영향인자에 관한 연구 (A study on influencing factors of AT4 experiment for the assessment of biological stability of landfilled waste)

  • 윤석표;김형욱;이남훈;김경;이병선
    • 유기물자원화
    • /
    • 제19권4호
    • /
    • pp.53-59
    • /
    • 2011
  • 본 연구에서는 $AT_4$ 방법으로 매립 폐기물의 생물학적 안정화도를 평가하는데 있어서, 실험자가 상이함에 따라 결과가 달라지는 것을 방지하기 위해 표준화된 실험을 위한 실험조건을 제시하고자 하였다. $AT_4$ 실험에 있어서 초기 지연시간, $CO_2$ 흡수제의 교체시기, 산소소모량 측정주기, 유기성 폐기물 함량에 따른 $AT_4$ 측정값 변화 추이등을 살펴보고, 각각에 따른 영향인자에 대해 논의하였다. 매립폐기물의 불균질성과 측정상의 오차범위를 감안할 때 매립폐기물의 안정화 기준치는 $AT_4$ 기준으로 $10mg\;O_2/g\;DM$의 값을 제시하였다.

Stability and Folding of a Mutant Ribose Binding Protein of Escherichia coli

  • Kim, Joon-Sik;Kim, Hyoungman
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 1996년도 정기총회 및 학술발표회
    • /
    • pp.25-25
    • /
    • 1996
  • A mature mutant ribose binding protein (RBP) of Escherichia coli was obtained by site-directed mutagenesis, replacing Thr-3 in the N-domain of wild-type mature RBP (WT -mRBP) with a Trp residue (N- Trp-mRBP). The equilibrium unfolding properties and the refolding kinetics of this protein were monitored by fluorescence and circular dichroism (CD). (omitted)

  • PDF

신체자세 안정도의 정량분석에 관한 연구 (Quantitative analysis of body postural stability)

  • 차은종;김경아;이태수;이경무;김남균;김연희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.39-43
    • /
    • 1997
  • Posturography stands or quantitative assessment of body postural stability analysis. The present study developed a balance plate system to monitor patient's center of pressure (COP) movement and to analyze its stability. An equilateral triangular shaped plate was made of duralumin and forces were measured on the three vertices of the plate using industrial load cells. Specially designed electronic circuit picked up force signals ed into data acquisition system to calculate the cartesian coordinates of COP. COP calculation error was less than 2%. The force signals enabled to compute stability measures, which consisted of a variety of clinical parameters related to postural stability. Clinical experiments were carefully designed and performed on 40 normal subjects. The results were that 1) postural stability decreased with age and 2) the best parameters were those of posture deviation measures. A customized PC-based software package was developed to apply the present technique with a great convenience to monitoring and analyzing postural stability in an accurate and quantitative way.

  • PDF