• Title/Summary/Keyword: bioimpedance

Search Result 50, Processing Time 0.029 seconds

Changes in bioimpedance analysis components before and after hemodialysis

  • Kim, Hyunsuk;Choi, Gwang Ho;Shim, Kwang Eon;Lee, Jung Hoon;Heo, Nam Ju;Joo, Kwon-Wook;Yoon, Jong-Woo;Oh, Yun Kyu
    • Kidney Research and Clinical Practice
    • /
    • v.37 no.4
    • /
    • pp.393-403
    • /
    • 2018
  • Background: This study compared nutritional parameters in hemodialysis (HD) subjects and controls using bioimpedance analysis (BIA) and investigated how BIA components changed before and after HD. Methods: This cross-sectional study included 147 subjects on maintenance HD from two hospitals and 298 propensity score-matched controls from one healthcare center. BIA was performed pre- and post-HD at mid-week dialysis sessions. Results: Extracellular water/total body water (ECW/TBW) and waist-hip ratio were higher in the HD patients; the other variables were higher in the control group. The cardiothoracic ratio correlated best with overhydration (r = 0.425, P < 0.01) in HD subjects. Blood pressure, hemoglobin, creatinine, and uric acid positively correlated with the lean tissue index in controls; however, most of these nutritional markers did not show significant correlations in HD subjects. Normal hydrated weight was predicted to be higher in the pre-HD than post-HD measurements. Predicted ultrafiltration (UF) volume difference based on pre- and post-HD ECW/TBW and measured UF volume difference showed a close correlation ($r^2=0.924$, P < 0.01). Remarkably, the leg phase angle increased in the post-HD period. Conclusion: The estimated normal hydrated weight using ECW/TBW can be a good marker for determining dry weight. HD subjects had higher ECW/TBW but most nutritional indices were inferior to those of controls. It was possible to predict UF volume differences using BIA, but the post-HD increase in leg phase angle, a nutritional marker, must be interpreted with caution.

Analysis of Bioimpedance Change and the Characteristics of Blood Pressure according to Posture (자세에 따른 생체임피던스 변화와 혈압 특성 분석)

  • Cho, Young Chang;Kim, Min Soo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.5
    • /
    • pp.25-31
    • /
    • 2014
  • Bioelectrical Impedance Analysis(BIA) is a widely used method for estimating body composition changes which is a non-invasive, inexpensive, safety and reproductive method. We studied the bioimpedance change and the distinction of blood pressure according to body posture and conducted three kinds of experiments: the real-time bioimpedance measurement, the simulation using equivalent circuit model and the blood pressure measurement. Bioimpedance is measured during 4 minutes at the multi-frequency(1 kHz, 10 kHz, 20 kHz, 50 kHz, 70 kHz, 100 kHz). From the experiment results, the changes in body postures result in changes of resistance and reactance, with an average rapid increase of body impedance when going from standing, sitting to supine. Specially, the laying resistance on average was 16.49% higher than supine resistance at 50 kHz and the laying reactance measurement was also 26.05% higher than sitting reactance at 1 kHz. Blood pressure in standing posture was higher than those in other postures both in maximum($125.14{\pm}12.30$) and in minimum($75.57{\pm}10.31$). The results of BIA and blood pressure in this study will be contributed to the research on acute illness, extreme fat, and body shape abnormalities.

Evaluation of Robust Classifier Algorithm for Tissue Classification under Various Noise Levels

  • Youn, Su Hyun;Shin, Ki Young;Choi, Ahnryul;Mun, Joung Hwan
    • ETRI Journal
    • /
    • v.39 no.1
    • /
    • pp.87-96
    • /
    • 2017
  • Ultrasonic surgical devices are routinely used for surgical procedures. The incision and coagulation of tissue generate a temperature of $40^{\circ}C-150^{\circ}C$ and depend on the controllable output power level of the surgical device. Recently, research on the classification of grasped tissues to automatically control the power level was published. However, this research did not consider the specific characteristics of the surgical device, tissue denaturalization, and so on. Therefore, this research proposes a robust algorithm that simulates noise to resemble real situations and classifies tissue using conventional classifier algorithms. In this research, the bioimpedance spectrum for six tissues (liver, large intestine, kidney, lung, muscle, and fat) is measured, and five classifier algorithms are used. A signal-to-noise ratio of additive white Gaussian noise diversifies the testing sets, and as a result, each classifier's performance exhibits a difference. The k-nearest neighbors algorithm shows the highest classification rate of 92.09% (p < 0.01) and a standard deviation of 1.92%, which confirms high reproducibility.

Bioimpedence to Assess Breast Density as a Risk Factor for Breast Cancer in Adult Women and Adolescent Girls

  • Maskarinec, Gertraud;Morimoto, Yukiko;Laguana, Michelle B;Novotny, Rachel;Guerrero, Rachael T Leon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.65-71
    • /
    • 2016
  • Although high mammographic density is one of the strongest predictors of breast cancer risk, X-ray based mammography cannot be performed before the recommended screening age, especially not in adolescents and young women. Therefore, new techniques for breast density measurement are of interest. In this pilot study in Guam and Hawaii, we evaluated a radiation-free, bioimpedance device called Electrical Breast Densitometer$^{TM}$ (EBD; senoSENSE Medical Systems, Inc., Ontario, Canada) for measuring breast density in 95 women aged 31-82 years and 41 girls aged 8-18 years. Percent density (PD) was estimated in the women's most recent mammogram using a computer-assisted method. Correlation coefficients and linear regression were applied for statistical analysis. In adult women, mean EBD and PD values of the left and right breasts were $230{\pm}52$ and $226{\pm}50{\Omega}$ and $23.7{\pm}15.1$ and $24.2{\pm}15.2%$, respectively. The EBD measurements were inversely correlated with PD ($r_{Spearman}=-0.52$, p<0.0001); the correlation was stronger in Caucasians ($r_{Spearman}=-0.70$, p<0.0001) than Asians ($r_{Spearman}=-0.54$, p<0.01) and Native Hawaiian/Chamorro/Pacific Islanders ($r_{Spearman}=-0.34$, p=0.06). Using 4 categories of PD (<10, 10-25, 26-50, 51-75%), the respective mean EBD values were $256{\pm}32$, $249{\pm}41$, $202{\pm}46$, and $178{\pm}43{\Omega}$ (p<0.0001). In girls, the mean EBD values in the left and right breast were $148{\pm}40$ and $155{\pm}54{\Omega}$; EBD values decreased from Tanner stages 1 to 4 ($204{\pm}14$, $154{\pm}79$, $136{\pm}43$, and $119{\pm}16{\Omega}$ for stages 1-4, respectively) but were higher at Tanner stage 5 ($165{\pm}30{\Omega}$). With further development, this bioimpedance method may allow for investigations of breast development among adolescent, as well as assessment of breast cancer risk early in life and in populations without access to mammography.

Validation of Segmental Multi-Frequency Bioelectrical Impedance Analysis based on the Segmental Bioelectrical Impedance analysis in the Elderly Population (분절임피던스를 기준한 분절다주파수 생체임피던스의 일치도 분석)

  • Tang, Sae-Jo;Kim, Jang-Hee;Eom, Jin Jong;Eom, Sunho;Kim, Hakkyun;Kim, Chul-Hyun
    • Journal of Platform Technology
    • /
    • v.9 no.2
    • /
    • pp.38-45
    • /
    • 2021
  • A frequently used bioimpedance analytical method in Korea is the segmental multi-frequency BIA (SMF-BIA) method, but it is not directly determined at a segmented impedance. This study was to compare SMF-BIA determinations with direct segmented determinations for accuracy and appropriateness of segment parameters. This study is to compare the segment parameters, accuracy and appropriateness of the multi-frequency segmental bioimpedance analysis. To this end, 108 elderly individuals were measured. Segmented bioelectrical measurements obtained from a SMF-BIA (Inbody S10) at 50 kHz and measured with a phase sensitive single frequency device (SF-BIA, bia-101, RJL / akern systems) were compared. The significant difference (%) was demonstrated between single - and multiple frequency determinations of the right upper limb (R = 35.5 ± 6.2%, P < 0.001; Xc = 2.7 ± 7.6%, P < 0.01), left upper limb difference (R= 33. 9 ± 6.0%, P < 0.001; Xc = 2.8 ± 8.3%, P < 0.01), right lower limb difference (R = 18.6 ± 4.3%, P < 0.001; Xc = 25.8 ± 10.0%, P < 0.001), left lower limb difference (R = 18.0 ± 4.7%, P < 0.001; Xc = 31.8%). Of the results determined with the two BIA methods, the impedance measurements of the limbs and whole body showed a high correlation (RA: R = 0. 950, LA: R = 0. 949, RL: R = 0.899, LL: R = 0.88), and in the agreement test, the impedance values of the upper limbs and whole body also showed strong agreement (ICC > 0.9), but in the Xc, the correlation was weak. In conclusion, it was found that although bioimpedance devices had significantly different characteristics and inconsistent cross sectionally, there was a high population level agreement in the upper and lower extremities in determining segmental resistance value changes. But a large error was found on the trunk. Further studies were needed for reducing the error.

Teleoperation of a Robot Manipulator using Bioimpedance (생체 임피던스를 이용한 로봇의 원격제어)

  • 김근영;김경환;김덕원;김수찬
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.13-16
    • /
    • 2001
  • 본 논문에서는 인간의 생체 임피던스를 이용하여 인간의 팔 운동을 추정하고자 한다. 생체 신호를 이용하여 인간의 운동을 추정하기 위해서는 먼저 생체 신호와 인간의 운동 사이의 정량적인 관계를 구해야 하며 특히, 다자유도 운동의 추정에는 생체 신호간의 간섭등을 고려하여야 한다. 본 논문에서는 먼저 일자유도 운동실험을 통해 생체 임피던스와 인간 팔 관절의 회전각 사이의 선형성을 고찰한다. 그리고, 다자유도 측정시에 발생하는 근육간의 결합성과 방향성의 문제에 대해 주파수 분할 측정법을 도입하여 팔의 다자유도 운동을 추정하였다. 마지막으로, 실제의 로봇을 제어하는데 응용하였다.

  • PDF

Improved negative capacitance circuit stable with a low gain margin (이득 여유가 작아도 안정한 개선된 네가티브 커패시턴스 회로)

  • 김영필;황인덕
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.6
    • /
    • pp.68-77
    • /
    • 2003
  • An improved negative capacitance circuit that cancels out input impedance of a front-end in a bioimpedance measurement and operates stably with a low gain margin has been proposed. Since the proposed circuit comprises wide-band operational amplifiers, selecting operational amplifiers is easy, while an operational amplifier of prefer bandwidth should be chosen to apply conventional circuit. Also, since gain margin can be controlled by a feedback resistor connected serially with a feedback capacitor, gain margin is tuneable with a potentiometer. The input impedance of the proposed circuit is two times larger than that of the conventional circuit and 40-times than that without a negative capacitance circuit. Furthermore, closed-loop phase response of the proposed circuit is better than that of the conventional circuit or without a negative capacitance circuit. Above all, for the proposed circuit, the frequency at which a gain peaking occurs is higher than the frequency at which the loop gain becomes a maximum. Thus, the proposed circuit is not affected by a gain peaking and can be operated with a very low gain margin.

Solid medium integrated impedimetric biosensor for detection of microorganisms (미생물 검침을 위한 고체 배지 임피던스 센서)

  • Choi, Ah-Mi;Park, Jae-Sung;Jung, Hyo-Il
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1629-1632
    • /
    • 2008
  • Rapid, real-time detection of pathogenic microorganisms is an emerging and quickly evolving field of research, especially with regard to microorganisms that pose a major threat to public health. Herein, a new method that uses bioimpedance and solid culture medium for the real-time detection of microorganisms is introduced. We fabricated a new impedimetric biosensor by integrating solid media and two plane electrodes attached on two facing sides of an acryl well. During bioelectrical impedance analysis, the solid medium showed the characteristics of a homogenous conductive material. In a real-time impedance measurement, our solid-medium biosensor could monitor bacterial growth in situ with a detection time of ${\sim}4$ hrs. Our data indicate that the solid-medium biosensor is useful for detecting airborne microorganisms, thereby providing a new analytical tool for impedance microbiology.

  • PDF

Measurements of Cardiac and Respiratory Signals using Impedance Method (임피던스 방법에 의한 심장 및 호흡 신호의 측정)

  • Kim, Hyung-Joong;Shim, Jae-Ok;Jang, Jae-Myeong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.183-186
    • /
    • 1993
  • We have developed a bioimpedance measurement system for impedance cardiography and pneumography. The system injects 50kHz, $200mA_{p-p}$ curreng into the thorax and measures the voltage changes using body surface electrodes. We used the four-electrode method for tile measurement of cardiac singnals and two-electrode method for respiratory signals. We developed a Microsoft Windows program for the acquisition, display, storage, and processing of impedance signals.

  • PDF

Bioelectrical Impedance Analysis of Multi-frequency using Portable Small Impedance Measuring System (휴대용 소형임피던스 측정시스템을 이용한 다중주파수의 생체임피던스 해석)

  • Kim, Min Soo;Cho, Young Chang
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.2
    • /
    • pp.121-126
    • /
    • 2017
  • In this study, we measured the bioelectrical impedance of whole body in various frequency bands by non-invasive method by four electrode method using a portable small impedance measurement system developed to understand the bioimpedance characteristics of intracellular fluid and extracellular fluid components through a skin equivalent model. The measurements were performed on 10 male subjects (mean age $24{\pm}3.0$, body mass index(BMI) $20.3kg/m^2$) for four weeks and the bioimpedances were measured at multi-frequencies (1 kHz, 5 kHz, 50 kHz, 70 kHz, 100 kHz and 500 kHz). Experimental results show that the impedance is the highest in the low frequency range of 1 kHz and the lowest in the high frequency range of 500 MHz. Especially, it was confirmed through experiments that the impedance is rapidly lowered above 50 kHz band. In addition, it was confirmed that similar characteristics to the measured values of the bioimpedance measuring system were obtained in the simulations for understanding the impedance characteristics of the intracellular fluid and the extracellular fluid through the skin equivalent circuit model.