• 제목/요약/키워드: bio-medical

검색결과 1,468건 처리시간 0.037초

MF-BIA Analyzer를 이용한 경혈의 세포 내액과 외액에 의한 저항성분 추정 방법 제시 및 반영률 평가 (The Suggestion of MF BIA Analyzer Method to Reflect the Resistance in the Extracelluar and Intracelluar Fluid at Acupoint & the Evaluation of Reflection Rate on the Tissue under Skin)

  • 김수병;이나라;김원기;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제29권4호
    • /
    • pp.563-572
    • /
    • 2012
  • Objectives : The aim of this study was to suggest a new method to estimate the resistance by acupoint compositions by using the multi-frequency bioelectrical impedance analysis(MF-BIA) of 5 kHz, 50 kHz and 200 kHz within 2 cm of acupoints as a local segment. Moreover, we try to confirm the relation to between measured resistance at skin surface and measured resistance by various manual acupuncture needle insertion depth. Methods : Ten male subjects participated in this study. We measured the resistance at left/right ST36 at skin surface and various manual acupuncture needle insertion depth(skin, 5 mm, 10 mm, 15 mm, 20 mm, 25 mm and 30 mm). Results : It was also observed that the all measured resistances were the highest at 5 kHz and the lowest at 200 kHz. There were significant differences at 5 kHz, 50 kHz and 200 kHz between measured resistance at skin surface and measured resistance by various manual acupuncture needle insertion depth(p<0.05). There was no significant difference in the left and right identical acupoints under the identical condition(p>0.05). Conclusions : We conclude that the measured resistance at skin surface has limitation as to reflect the information of tissue. However, the measured resistance at each frequency was changed as similar pattern by different insertion depth. Hence, we confirmed the possibility of assumption on information of tissue which was expected to locate an acupoint.

능동형 근육펌프 구조의 수액 주입 펌프 개발에 관한 연구 (A Study on the Development of a Infusion Pump based on an Active Muscle Pump)

  • 이정환;이상엽;이정은;안인석
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.443-449
    • /
    • 2022
  • In this study, in order to improve the disadvantages of the environmental error of the infusion set that performs infusion therapy in the existing clinical practice and to maximize the user's convenience by miniaturizing the existing infusion pump system, the structure of the muscle pump of the human vein was imitated. As a double check valve method, a method for preventing the backflow of fluid and discharging a constant fluid in one direction by external pressure was proposed. The proposed bio-mimic muscle pump uses a check valve that controls the flow of fluid in one direction and a silicone tube with elasticity, and a chamber is constructed. A peristaltic pump for applying intermittent pressure to the tube chamber was constructed using a multi-cam structure roller. In order to verify the performance of the proposed pump, optimization was performed while changing the number of multi-cam rollers and adjusting the speed of the roller driving motor, and the reproducibility of the instantaneous discharge amount and the continuous discharge amount of the pump was compared and tested. The performance of the muscle pump proposed in this study was verified through experiments that it can inject up to 1L of fluid within 12 hours, and that it is possible to inject the fluid with an accuracy of ±0.1ml. Real-time monitoring of the fluid injection volume through the bio-mimic muscle pump proposed in this study not only increases the convenience of the administrator, but also provides a precise fluid administration environment to more patients at a low cost, and additionally applies bubble detection and occlusion detection technology If so, it is believed that a safer medical environment can be provided to patients.

Effects of Korean Red Ginseng extract on busulfan-induced dysfunction of the male reproductive system

  • Jung, Seok-Won;Kim, Hyeon-Joong;Lee, Byung-Hwan;Choi, Sun-Hye;Kim, Hyun-Sook;Choi, Yang-Kyu;Kim, Joon Yong;Kim, Eun-Soo;Hwang, Sung-Hee;Lim, Kwang Yong;Kim, Hyoung-Chun;Jang, Minhee;Park, Seong Kyu;Cho, Ik-Hyun;Nah, Seung-Yeol
    • Journal of Ginseng Research
    • /
    • 제39권3호
    • /
    • pp.243-249
    • /
    • 2015
  • Background: Anticancer agents induce a variety of adverse effects when administered to cancer patients. Busulfan is a known antileukemia agent. When administered for treatment of leukemia in young patients, busulfan could cause damage to the male reproductive system as one of its adverse effects, resulting in sterility. Methods: We investigated the effects of Korean Red Ginseng extract (KRGE) on busulfan-induced damage and/or dysfunction of the male reproductive system. Results: We found that administration of busulfan to mice: decreased testis weight; caused testicular histological damage; reduced the total number of sperm, sperm motility, serum testosterone concentration; and eventually, litter size. Preadministration of KRGE partially attenuated various busulfan-induced damages to the male reproductive system. These results indicate that KRGE has a protective effect against busulfan-induced damage to the male reproduction system. Conclusion: The present study shows a possibility that KRGE could be applied as a useful agent to prevent or protect the male reproductive system from the adverse side effects induced by administration of anticancer agents such as busulfan.

모빅 캡슐(멜록시캄 7.5 mg)에 대한 멜락스 캡슐의 생물학적동등성 (Bioequivalence of MelaxTM Capsule to MobicTM Capsule (Meloxicam 7.5 mg))

  • 이예리;염승복;고연정;고정길;김호현;이희주;이경률
    • Journal of Pharmaceutical Investigation
    • /
    • 제34권5호
    • /
    • pp.413-418
    • /
    • 2004
  • A bioequivalence of $Melax^{TM}$ capsules (Chong Kun Dang Pharm., Korea) and $Mobic^{TM}$ capsules (Boehringer Ingelheim Korea) was evaluated according to the guideline of Korea Food and Drug Administration (KFDA). Single 15 mg dose of meloxicam of each medicine was administered orally to 24 healthy male volunteers. This study was performed in a $2\;{\times}\;2$ crossover design. Concentrations of meloxicam in human plasma were monitored by a high-performance liquid chromatography. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 72 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was performed using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Melax^{TM}/Mobic^{TM}$ were 0.95 - 1.04 and 0.98 - 1.14, respectively. This study demonstrated a bioequivalence of $Melax^{TM}$ and $Mobic^{TM}$ with respect to the rate and extent of absorption.

산 및 효소 가수분해를 이용한 홍조류로부터 바이오 에탄올 생산 (Production of Bio-ethanol from Red Algae by Acid Hydrolysis and Enzyme Treatment)

  • 최수정;이성목;이재화
    • 공업화학
    • /
    • 제23권3호
    • /
    • pp.279-283
    • /
    • 2012
  • 화석연료로 인한 환경오염 등의 문제를 해결하기 위해서 다양한 원료를 이용하여 바이오 에탄올 생산에 대한 연구가 진행되고 있다. 해조류 중에 홍조류는 agar, carrageenan, porphyran으로 구성되어 있어 산 처리를 통해 바이오에탄올 생산에 유용한 바이오매스로 전환이 가능하다. 본 연구는 홍조류의 가수분해물을 이용하여 바이오에탄올 생산의 최적 조건을 찾으려고 한다. 바이오에탄올 생산하기 위해 전처리 된 우뭇가사리에 Saccharomyces cerevisiae KCCM112를 접종해 발효하였다. 우뭇가사리 가수분해의 최적조건은 1.5% $H_2SO_4$$121^{\circ}C$에서 30 min 반응시켰을 때 7.04 g/L의 galactose와 1.94 g/L의 glucose가 생산되었다. 그리고 $CH_3COOH$의 경우 2.0% 농도로 처리하였을 때, galactose 0.75 g/L가 생산되었다. 이와 반대로 도박에서는 $H_2SO_4$1.5%를 처리하였을 때 galactose를 6.38 g/L 생산하였으며, $CH_3COOH$을 처리했을 때 0.368 g/L이 생산되었다. 우뭇가사리에서 에탄올 생산은 1.0% $H_2SO_4$$121^{\circ}C$에서 30 min 간 처리하였을때 가장 높았으며, 96 h 배양하였을 때 3.77 g/L의 에탄올을 생산했다.

3D 바이오 프린팅 기술 현황과 응용 (Status and Prospect of 3D Bio-Printing Technology)

  • 김성호;여기백;박민규;박종순;기미란;백승필
    • KSBB Journal
    • /
    • 제30권6호
    • /
    • pp.268-274
    • /
    • 2015
  • 3D printing technology has been used in various fields such as materials science, manufacturing, education, and medical field. A number of research are underway to improve the 3D printing technology. Recently, the use of 3D printing technology for fabricating an artificial tissue, organ and bone through the laminating of cell and biocompatible material has been introduced and this could make the conformity with the desired shape or pattern for producing human entire organs for transplantation. This special printing technique is known as "3D Bio-Printing", which has potential in biomedical application including patient-customized organ out-put. In this paper, we describe the current 3D bio-printing technology, and bio-materials used in it and present it's practical applications.

생물학적동등성시험을 위한 통계처리 프로그램(BioEquiv)의 개발 (Development of BioEquiv, a Computer Program for the Analysis of Bioequivalence)

  • 윤상후;황난아;임영채;이용복;박정수
    • Journal of Pharmaceutical Investigation
    • /
    • 제40권1호
    • /
    • pp.1-7
    • /
    • 2010
  • K-$BEtest^{(R)}$ is a well known program for bioequivalence test using a $2{\times}2$ design. Lee et al.(1998) and Park et al.(1999) suggested a $3{\times}3$ and $3{\times}2$ design, and also discussed their benefits. We developed a computer program, called BioEquiv, which can analyze some complex experimental designs such as, $3{\times}3$ design and $3{\times}2$ design including a standard $2{\times}2$ design. This program is a user-friendly one and overcomes the disadvantages of K-$BEtest^{(R)}$. The detailed statistical formula and structure of BioEquiv are presented with some examples. The comparison between K-$BEtest^{(R)}$ and BioEquiv are given with actual data analysis. BioEquiv is able to present a table of ANOVA test over some complex experimental designs. Moreover K-$BEtest^{(R)}$ and BioEquiv draw the same result when data consists of $2{\times}2$ design.

엑스선 그레이 스케일 리소그래피를 활용한 반원형 단면의 서브 마이크로 선 패턴의 바이오멤스 플랫폼 응용 (X-ray grayscale lithography for sub-micron lines with cross sectional hemisphere for Bio-MEMS application)

  • 김강현;김종현;남효영;김수현;임근배
    • 센서학회지
    • /
    • 제30권3호
    • /
    • pp.170-174
    • /
    • 2021
  • As the rising attention to the medical and healthcare issue, Bio-MEMS (Micro electro mechanical systems) platform such as bio sensor, cell culture system, and microfluidics device has been studied extensively. Bio-MEMS platform mostly has high resolution structure made by biocompatible material such as polydimethylsiloxane (PDMS). In addition, three dimension structure has been applied to the bio-MEMS. Lithography can be used to fabricate complex structure by multiple process, however, non-rectangular cross section can be implemented by introducing optical apparatus to lithography technic. X-ray lithography can be used even for sub-micron scale. Here in, we demonstrated lines with round shape cross section using the tilted gold absorber which was deposited on the oblique structure as the X-ray mask. This structure was used as a mold for PDMS. Molded PDMS was applied to the cell culture platform. Moreover, molded PDMS was bonded to flat PDMS to utilize to the sub-micro channel. This work has potential to the large area bio-MEMS.

고효율 크기 가변적 입자 분리를 위한 통합 하이브리드 소자 (Integrated Hybrid Device for High-Efficiency Size-Tunable Particle Separation)

  • 추승희;박지온;김태은;강태경;안준석;오가영;김여진;박규빈;박채원;이민정;임현정;남정훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권3호
    • /
    • pp.170-176
    • /
    • 2022
  • Cell separation from a heterogenous mixture sample is an essential process for downstream analysis in biological, chemical, and clinical applications. This study demonstrates an integrated hybrid device of the viscoelastic focusing in a straight rectangular channel and subsequent size-based separation using acoustophoresis to attain high efficiency and separation tunability. For particle pre-alignment in a viscoelastic fluid, the flow rate higher than 10 μl/min was required. Surface acoustic wave-based lateral migration of particles with different sizes (13 and 27 ㎛) was examined at various applied voltages and flow rate conditions. Therefore, the flow rate of 100 μl/min and the applied voltage of 20 Vpp can be used for size-based particle separation.