Browse > Article
http://dx.doi.org/10.21289/KSIC.2022.25.3.443

A Study on the Development of a Infusion Pump based on an Active Muscle Pump  

Lee, Jeong-Whan (Dept. of BioMedical Eng., Konkuk University)
Lee, Sang-Yeob (Dept. of BioMedical Eng., Konkuk University)
Lee, Jung-Eun (School of Nursing, Cheju Halla University)
Ahn, Ihn-Seok (Div. of Energy & Electrical Eng., Uiduk University)
Publication Information
Journal of the Korean Society of Industry Convergence / v.25, no.3, 2022 , pp. 443-449 More about this Journal
Abstract
In this study, in order to improve the disadvantages of the environmental error of the infusion set that performs infusion therapy in the existing clinical practice and to maximize the user's convenience by miniaturizing the existing infusion pump system, the structure of the muscle pump of the human vein was imitated. As a double check valve method, a method for preventing the backflow of fluid and discharging a constant fluid in one direction by external pressure was proposed. The proposed bio-mimic muscle pump uses a check valve that controls the flow of fluid in one direction and a silicone tube with elasticity, and a chamber is constructed. A peristaltic pump for applying intermittent pressure to the tube chamber was constructed using a multi-cam structure roller. In order to verify the performance of the proposed pump, optimization was performed while changing the number of multi-cam rollers and adjusting the speed of the roller driving motor, and the reproducibility of the instantaneous discharge amount and the continuous discharge amount of the pump was compared and tested. The performance of the muscle pump proposed in this study was verified through experiments that it can inject up to 1L of fluid within 12 hours, and that it is possible to inject the fluid with an accuracy of ±0.1ml. Real-time monitoring of the fluid injection volume through the bio-mimic muscle pump proposed in this study not only increases the convenience of the administrator, but also provides a precise fluid administration environment to more patients at a low cost, and additionally applies bubble detection and occlusion detection technology If so, it is believed that a safer medical environment can be provided to patients.
Keywords
Infusion Set; Infusion Pump; Muscle Pump; Check Valve; Multi-CAM Roller;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kim, J. I., Lee, J. H., & Chang, O. J. "Perceived importance and perfor- mance of intravenous fluid therapy by nurses in small-medium general ho spitals", Korean Journal of Fundamentals of Nursing, 20(4), 372-380, 2013.   DOI
2 Kaushal, R., Bates, D. W., Landrigan, C., McKenna, K. J., Clapp, M. D., Federico, F., & Goldmann, D. A. "Medication errors and adverse drug events in pediatric inpatients", Journal of the American Medical Association, 285, 2114-2120, 2001.   DOI
3 Crass, R. E., & Vance, J. R., "In vivo accuracy of gravity-flow i.v. infusion systems". American Journal of Hospital Pharmacy, 42(2), 328-331, 2012.
4 K.-Y. Ha, C. Nam, H.-S. Kim, and others, "Development of Real-time Checking System on Ringer's Solution Using Load Cell," ICCAS 2005, pp. 1409-1412, 2005.
5 Park, K., Lee, J., Kim, S. Y., Kim, J., Kim, I., Choi, S. P., Jeong, S. & Hong, S., "Infusion Control and Calculation with Metronome and Drop Counter Based Infusion Therapy Helper", International Journal of Nursing Practice, 19(3), 257-264, 2012.   DOI
6 Anrep, G. V. and E. von Saalfeld, "The blood flow through the skeletal muscle in relation to its contraction", J. Physiol., 85: 375-399, 1935.   DOI
7 김정숙, 이승재, 정은미, 정준호, 정장영, "안드로이드 기반 의료 수액 속도 측정 모바일 응용프로그램 개발," 한국지능시스템 학회 2013년도 추계학술대회 학술발표논문집 제 23 권 제 2 호, vo l. 23, no. 2, pp. 61-62, 2013.
8 Mousavi, M., Khalili, H., & Dashti- khavidaki, S., "Erros in fluid therapy in medical wards", International Journal of Clinical Pharmacy, 34, 374-381, 2012.   DOI