• Title/Summary/Keyword: bio-fouling

Search Result 49, Processing Time 0.024 seconds

Reuse of Weaving Wastewater by Membrane Bioreactor Equipped with a Hollow-fiber MF Membrane (중공사 정밀여과 MBR공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.365-369
    • /
    • 2004
  • Submerged membrane bio-reactor equipped with a hollow fiber microfiltration was applied to reuse weaving wastewater of water jet loom, where two parameters such as the concentration of MLSS and the flux were controlled. While the flux at the concentration of MLSS around 900mg/L was constantly kept over 0.4m/d and 0.8m/d in a short time, the stable flux at around 300mg/L of MLSS was shown at the 8 days later. Regardless of MLSS and flux, BOD, CODcr and Turbidity of the permeate were 1~2mg/L, 7~10mg/L and below 1 NTU, which were 85~90%, 87~90% and 98% of removal efficiency, respectively. The stable operation without fouling was achieved because the contents of ECP were smaller than those of common MBR processes and the composition(saccharide/protein) was kept constantly. In this study, 0.5~1.0m/d of flux and 400~900mg/L of MLSS were considered as the most recommendable operating condition for the reuse of weaving wastewater.

Sole and Combined Usage of Ultra-sonication and Hydrogen Peroxide as Mitigation Techniques of Bio-fouling

  • Haque, Md. Niamul;Kwon, Sung-hyun
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1397-1405
    • /
    • 2016
  • Mussels are stubborn organism attached to solid substrate by byssus threads and caused operational problems in utility of power generating stations. Sole and combined usage of ultrasonic (28 kHz- and 42 kHz- frequencies) and hydrogen peroxide ($H_2O_2$) has studied for control of blue mussel larvae and adult stage in seawater condition. A theoretical wo rking model using disinfection (Chick and Watson type) approaches is presented based on helpful results of experiments. This study also demonstrate that the combined treatment (ultra-sonication with $H_2O_2$) is overall highly efficient than individual treatment would, but on the basis of exposure time, the ultra-sonication was the most efficient among them. Therefore the development of sole and combined technique might be effective practical mitigation strategy against mussel attachment for water handling facilities.

Effect of Antifouling Composite Membrane on Membrane Bioreactor: A Review (방오성 복합막의 막생물반응기에 대한 영향)

  • Lee, Bo Woo;Lee, Sunwoo;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.30 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In membrane bioreactor (MBR), activated sludge degrade the biological component and membrane process separate this bacterial flocks as well the suspended solids. However, membrane fouling is one of the major issues in MBR. In this review, composite membrane used in MBR to overcome fouling is discussed. It is classified into membrane containing carbon and noncarbon materials. Introducing graphene, graphene oxide (GO) and carbon nanotubes or their modified part into pristine membrane enhance hydrophilicity of the composite membrane. Inorganic materials like silicon dioxide (SiO2) or titanium dioxide (TiO2) are also incorporated for preparing composite membrane to increase its water flux.

Review on Membranes Containing Silver Nanoparticles with Antibacterial and Antifouling Properties (항균 및 방오 특성을 가진 은나노 입자 함유 분리막에 대한 총설)

  • Kim, HanSol;Patel, Rajkumar;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.293-303
    • /
    • 2021
  • Separation membranes used in water filtration, protein purification or biomedical filtration device frequently undergo membrane fouling for several reasons. The formation of biofilm on the membrane surface by bacteria causes a severe problem for durability of the membrane. For the protein separation, the membrane pores get blocked due to surface hydrophobicity of the membrane. There are several approaches controlling the membrane fouling and one of them is the incorporation of silver nanoparticles. Antibacterial properties of silver nanoparticles are well known and thus widely used in several applications. In this review, we have focused on the membranes where silver nanoparticles or its derivatives are either incorporated in the active layer of thin film composite membranes or uniformly distributed throughout the whole membranes.

Research on improvement of water purification efficiency by porous concrete using bio-film (생물막을 이용한 다공성 콘크리트의 수질정화 효율 개선에 대한 연구)

  • Kim, Tae-Hoon;Li, Feng-Qi;Ahn, Tae-Woong;Choi, I-Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.815-821
    • /
    • 2011
  • This study aims to estimate the biological decomposition capacity of MPC(Microorganism Porous-Concrete). MPC has specific surface area formed by inside pores, and bio compound was added to those pores to reduce pollutants loading. To evaluate the water purification capacity of MPC, we carried out the comparative studies using different media types [GPC(General Porous-concrete), CPC(Compound porous-concrete), LPC(Lightweight aggregate porous-concrete)] under the condition of CFSTR, and different retention times (30, 60 and 120 min). We also estimated the purification capacity of MPC under different concentrations of pollutant loadings. The MPC showed higher efficiency in water purification function than other conventional porous concretes with efficient decrease rates of SS, BOD, COD, and nutrient concentrations. In the comparison experiment for different retention times, MPC showed the highest removal efficiency for all tested pollutants in the longest retention time(120 min). In the long period test, the removal efficiencies of MPC concrete were high until 100 days after the set up of the operation, but began to decrease. Outflow flux was invariable compared with inflow flux so that extra detention time for media fouling such as back washing is not needed. But the results suggested that appropriate management is necessary for long-term operation of MPC. As the final outcome, MPC using bio organisms is considered to be efficient for stream water purification when they used as substrates for artificial river structure.

Flux Decline Behavior in Cross-flow Microfiltration of Inorganic Colloidal Suspensions (무기 콜로이드 현탁액의 십자류 정밀여과에 의한 투과유속의 감소거동)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.338-348
    • /
    • 2005
  • The permeate flux decline on microfiltration capillary membrane operation was investigated with inorganic colloidal solutions. The permeate flux of the alumina solution is two times higher in average than that of the bentonite solution. The flux decline with increase in operation time was less in the alumina solution than in the bentonite solution. The rate of initial flux decline until 10 min was higher on the bentonite solution over the alumina solution. The decline in permeate flux was due to both the cake formation and the pore blocking. The latter effect was higher in the operation of the bentonite solution. In comparing the ratio of each fouling component to the total fouling fur the $1.0\;kg_f/cm^2$ TMP condition, complete blocking was $9.35\%$, standard blocking was about $6.82\%$ and cake filtration was $83.83\%$, respectively. With the increase in cross flow velocity, the permeate flux increased by $6.0\%$ for the alumina solution and by 14.0 for the bentonite solution. With the increase in average pore size fromm $0.24\;{\mu}m\;to\;0.34\;{\mu}m$, the permeate flux increases 1.61 times for the alumina solution and 1.76 times far the bentonite solution.

Characteristics of Flux Decline in Microfiltration Capillary Membrane of Bentonite Colloidal Suspensions (정밀여과 모세관 막을 이용한 벤토나이트 콜로이드 현탁액의 투과유속 감소특성)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.52-61
    • /
    • 2005
  • Permeate flux decline in a microfiltration was analyzed by measuring the permeability of bentonite colloidal solution through polyethylene capillary membranes. The flux decline with time was due to the growth of cake layer on the membrane surface and to the pore blocking by particles. As the time approaches to steady state, the permeate flux is almost controlled by the cake filtration model. Faster flux decline at high trans-membrane pressure was attributed to the formation of denser packed cake layer and pore blocking. The ratio of permeate flux to the initial permeate flux, J/J₁, decreased with increasing the trans-membrane pressure, from 45% for 0.5 kg/sub f//㎠ to 38% for 2.0 kg/sub f//㎠. In comparing the ratio of each fouling component to the total fouling for the 0.5 kg/sub f//㎠ TMP condition, complete blocking was 23.4%, standard blocking was about 14.6% and cake filtration was 62.0%, respectively. Permeate flux through the membrane increases with cross flow velocity, and the effect of the variation of velocity is more significant at 1.0 kg/sub f//㎠ rather than at 2.0 kg/sub f//㎠ of the operation pressure. Permeate flux for the membrane having the average pore diameter of 0.34 ㎛ was higher than that for the membrane of 0.24 ㎛ pore size, with the higher flux with the low concentration of feed. On the operation using the membrane of 0.34 ㎛ pore, the pore blocking in the low concentration of 200 ppm is negligible relative to the pore blocking in the 1000 ppm feed.

Development of PTFE Membrane Bio-reactor (MBR) for Integrating Wastewater Reclamation and Rainwater Harvesting (PTFE막을 이용한 빗물 중수 통합형 MBR 시스템 개발 및 성능 평가)

  • Lee, Taeseop;Kim, Youngjin;Ham, Sangwoo;Hong, Seungkwan;Park, Byungjoo;Shin, Yongil;Jung, Insik
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.269-276
    • /
    • 2012
  • The surface characteristics and performance of PTFE (polytetrafluoroethylene) hollow fiber membranes have been systematically investigated at lab- and pilot-scale to assess their application to membrane-bioreactor, particularly for integrating wastewater reclamation and rainwater harvesting. The PTFE membrane expressed some surface features, such as hydrophobicity, which might enhance membrane fouling. However, lab-scale performance and cleaning experiments under various conditions demonstrated that the PTFE membrane could produce the desirable water flux with good cleaning efficiency, implying easy operation and maintenance due to superior chemical resistance of PTFE membranes. Most of effluent water qualities were met with Korean standard for discharge and reuse, except color. Color level was further reduced by blending with rainwater at 75:25 ratio. Based on the lab-scale experimental results, the pilot plant was designed and operated. Pilot operation clearly showed sTable performance with satisfactory water quality, suggesting that PTFE membrane could be applied for decentralized MBR integrated with rainwater use.

Effect of powder activated carbon replacement on HCPAC-MBR system operation (고농도 분말활성탄 결합 MBR 운전에 대한 활성탄 교체주기의 영향)

  • Lee, Chae-Ha;Kim, Jin-Tae;Lee, Jung-Hyun;Seo, Gyu-Tae;Kim, In S.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.141-148
    • /
    • 2008
  • This study was conducted to evaluate the effect of PAC(Powder Activated Carbon) retention time on stable operation of high concentration powered activated carbon(HCPAC-MBR) in the treatment of secondary domestic wastewater. The pilot scale HCPAC-MBR system was operated at two different SRTs, 25 days and 100 days. The main drawback of HCPAC-MBR system was the rapid increase of trans-membrane pressure. The increase rate of trans-membrane pressure was proportional to SRT value at constant flux. This result seemed to be caused by reduced amount of EPS adsorbed on the PAC in the reactor by decreasing the SRT of the PAC. The particle size of the PAC was also influenced by SRT. The PAC size was decreased as SRT was increased. The change of particle size could be one reason for the change of trans-membrane pressure. The pore volume in the cake-layer formed on the membrane surface became to be increased by reducing SRT, because the cake-layer was highly composed of the PAC. Therefore, increased pore volume might play a role to reduce the trans-membrane pressure. The removal rate of E260 and TOC was also inversely proportional to SRT value.

Evaulation of Developing New-Fusion Eco-Friendly Biocide on the Reverse Osmosis Membranes (살균에 박리 및 분산 기능이 추가된 친환경살균제에 대한 역삼투(RO)막에서의 효과 검증 연구)

  • Park, Duk Joon;Oh, Eun Jung;Kim, Sung Han;Ahn, Kwang Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.497-503
    • /
    • 2016
  • Eco-friendly biocide that do not have noxious chemicals, have a role of disinfection adding of dispersion and strengthening peer power on RO membranes surfaces. Eco-friendly biocide show an 93% improvement of differential pressures arrival time. Also, eco-friendly biocide's Autopsy result show less the percentage of organic pollutants than currently in using biocide. Adding dispersion & peeling strength power to remove the microorganisms is upgrading. Eco-friendly biocide that have a dispersion and peering power is non-toxicant chemicals and is safe for user.