• 제목/요약/키워드: beta-ray method

검색결과 184건 처리시간 0.022초

베타선 흡수법을 이용하는 미세먼지 측정시스템을 위한 잡음제거 방법 (Noise Reduction Method for Particle Measurement System using Beta-ray Absorption Method)

  • 최훈;손상욱;배현덕
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1706-1712
    • /
    • 2012
  • The Beta-ray absorption method (BAM) gives a good solution for measuring the mass concentration of atmospheric particles(PM10 and PM2.5). To determine particular matters (PM) concentration, a ratio of the number of detected beta-ray intensity passing through the clean filter and the dust-sampled filter is used. These intensity data measured in air pollution monitoring such as PM10 and PM2.5 usually contained the additive noise(thermal noise, power supply noise and etc.). Therefore, the estimation performance of mass concentration can be deteriorated by these noises. In this paper, we present a new noise reduction method that is essentially required to develope an automatic continuous PM monitoring system using beta-ray absorption method. By combining the block data averaging technique and curve fitting, in the proposed method, the additive noise can be reduced in the measured data. To evaluate the performance of the proposed method, computer simulations were performed with computer generated signals as the input.

측정방법 및 기상상태에 따른 PM-10 질량농도 비교 (Comparison of the PM-10 mass concentration in different measurement methods and meteorological conditions)

  • 정창훈;박진희;황승만;정용국
    • 한국입자에어로졸학회지
    • /
    • 제5권2호
    • /
    • pp.53-62
    • /
    • 2009
  • In this study, the continuous monitoring of the concentration of PM-10 atmospheric particulate matter using beta ray attenuation method was compared with gravimetric method from September, 2006 to August, 2007. On the effects of the PM-10 concentration and mass difference by relative humidity and precipitation were considered. The result showed that the measurement error between beta ray method and gravimetric method are within -3~6% in average, which means PM-10 concentration data with beta ray method are relatively comparable. The current study also shows that the high PM-10 concentration events are mainly due to haze, Asian dust, and high relative humidity and the PM-10 mass concentration is closely related with relative humidity and precipitation events. Based on daily mean data, the PM-10 increases as relative humidity increases up to 70~80%, then decreases over 80% due to the precipitation. However, the distinct measurement discrepancy was not shown between beta ray method and gravimetric method based on current results. Consequently, this study shows that the collocated measurement in different instrument is essential in order to quantify the accuracy of PM-10. Furthermore, the more comprehensive and spatially distributed comparison is needed and this is remained for future study.

  • PDF

Plastic scintillator beta ray scanner for in-situ discrimination of beta ray and gamma ray radioactivity in soil

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1259-1265
    • /
    • 2020
  • A beta ray scanner was proposed for in-situ discrimination of beta and gamma ray radioactivity. This scanner is based on the principle that gamma and beta rays experience different changes in detection efficiency in scintillators with different geometries, especially with regard to the scintillator thickness. The ratios of the counting rates of gamma rays (Rgamma), beta rays (Rbeta), and sample measurements (Rtotal) in a thick scintillator to those in a thin one are reported. The parameter Xthick, which represents the counting rate contributed by beta rays to the total counting rate in the thick scintillator, was derived as a function of those ratios. The values of Rgamma and Rbeta for 60Co and 90Sr sources were estimated as 3.2 ± 0.057 and 0.99 ± 0.0049, respectively. The estimated beta ray contributions had relative standard deviations of 2.05-4.96%. The estimated range of the beta rays emitted from 90Sr was 19 mm as per the Monte Carlo N-Particle simulation, and this value was experimentally verified. Homogeneous and surface contaminations of 60Co and 90Sr-90Y were simulated for application of the proposed method. The counting rate contributed by the beta rays was derived and found to be proportional to the concentration of 90Sr-90Y contamination.

지하역사 내 미세먼지 실시간 모니터링을 위한 광산란법 보정 (Compensation of Light Scattering Method for Real-Time Monitoring of Particulate Matters in Subway Stations)

  • 김서진;강호성;손윤석;윤상렬;김조천;김규식;김인원
    • 한국대기환경학회지
    • /
    • 제26권5호
    • /
    • pp.533-542
    • /
    • 2010
  • The $PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the underground subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. As for the measurement of $PM_{10}$ concentrations, instruments based on $\beta$-ray absorption method and gravimetric methods are being used. But the instruments using gravimetric method give us 20-hour-average data and the $\beta$-ray instruments can measure the $PM_{10}$ concentration every one hour. In order to keep the $PM_{10}$ concentrations under a healthy condition, the air quality of the underground platform and tunnels should be monitored and controlled continuously. The $PM_{10}$ instruments using light scattering method can measure the $PM_{10}$ concentrations every less than one minute. However, the reliability of the instruments using light scattering method is still not proved. The purpose of this work is to study the reliability of the instruments using light scattering method to measure the $PM_{10}$ concentrations continuously in the underground platforms. One instrument using $\beta$-ray absorption method and two different instruments using light scattering method (LSM1, LSM2) were placed at the platform of the Jegi station of Seoul metro line Number 1 for 10 days. The correlation between the $\beta$-ray instrument and the LSM2 ($r^2$=0.732) was higher than that between the $\beta$-ray instrument and the LSM1 ($r^2$=0.393). Thus the LSM2 was chosen for further analysis. Three different regression analysis methods were tested: Linear regression analysis, Nonlinear regression analysis and Orthogonal regression analysis. When the instruments using light scattering method were used, the data measured these instruments have to be converted to actual $PM_{10}$ concentrations using some factors. With these analyses, the factors could be calculated successfully as linear and nonlinear forms with respect to the data. And the orthogonal regression analysis was performed better than the ordinary least squares method by 28.45% reduction of RMSE. These findings propose that the instruments using light scattering method light scattering method can be used to measure and control the $PM_{10}$ concentrations of the underground subway stations.

시클로덱스트린류와의 복합체 형성에 의한 벤즈이미다졸계 구충 약물의 용해성 및 용출 증가 (Solubilization and Dissolution Enhancement of Benzimidazole Antnelmintic Drugs by Cyclodextrin Complexation)

  • 전인구;박인숙
    • 약학회지
    • /
    • 제37권3호
    • /
    • pp.216-227
    • /
    • 1993
  • Complex formations of practically insoluble antelmintic drugs such as mebendazole (MBZ), albendazole (ABZ) and flubendazole (FBZ) with dimethyl-$\beta$-cyclodextrin (DM-$\beta$-CyD) and 2-hydroxypropyl-$\beta$-cyclodextrin (HP-$\beta$-CyD) together with $\alpha$-, $\beta$- and $\gamma$-cyclodextrins(CyDs) in duffered solutions were investigated by solubility method. $A_{L}$ type phase solubility diagrams were obtained in all cases except for the complexation (B$_{s}$, type) of FBZ with $\gamma$-CyD. The highest stability constants were obtained with DM-$\beta$-CyD, followed by $\alpha$-CyD > $\beta$-CyD > HP-$\beta$-CyD > $\gamma$-CyD for ABZ, and HP-$\beta$-CyD > $\gamma$-CyD > $\beta$-CyD > $\alpha$-CyD for FBZ at pH 1.2. On the other hand, solid dispersion systems of ABZ and FBZ with $\beta$- and DM-$\beta$-CyDs were prepared by solvent evaporation method and evaluated by dissolution, differential thermal analysis and powder x-ray diffractometry. The dissolution rates of ABZ- and FBZ-DM-$\beta$-CyD solid dispersions were much faster than those of drugs alone, corresponding physical mixtures and tablets on market both at pH 1.2 and 6.8. Although dissolution rates of all samples at pH 6.8 were by far lower than those obtained at pH 1.2, as explained by pH-solubility profiles for ABZ and FBZ, the dissolution rates at pH 6.8 of ABZ from $\beta$- and DM-$\beta$-CyD solid dispersions exceeded the respective equilibrium solubility (23.9 $\mu\textrm{g}$/ml). Fast dissolution of ABZ from solid dispersions with CyDs was attributed to the reduction of drug crystallinity and particle size which was supported by DTA and powder x-ray diffractometry. Consequently these results suggest that solid dispersion systems with CyDs may provide useful means to markedly enhance the solubility and dissolution of benzimidazole antelmintic drugs.

  • PDF

몬테카를로 방법을 이용한 치료용 방사성동위원소 사용 시 단일 세포에 대한 선량 분석 (Analysis of Radiation Dose on Single Cells Using Therapeutic Radioisotopes Using the Monte Carlo Method)

  • 김정훈;김유수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.433-438
    • /
    • 2022
  • Targeted radionuclides treatment (TRT) requires the establishment of treatment plans that consider various factors, such as the type of radionuclides, target organs, and administration methods. For this reason, in this study, the absorption dose of a single cell was analyzed according to the type of radioisotope used to treat target radionuclides. In this study, a simulation was performed on beta rays used in the treatment of target radionuclides at the cell level using MCNPX (ver. 2.5.0). First, according to the calculation formula, the beam path according to the type of radioisotope for treatment was calculated. Second, the amount of self-radiation by beta rays emitted from cell diameters of 5 ㎛ and 10 ㎛ cell nuclei was evaluated. As a result, it showed a high range proportional to the maximum energy of the beta-ray, and the highest self-dose distribution from 177 Lu radiation sources among therapeutic radioisotopes. This was analyzed as a result that is inversely proportional to the maximum energy of the beta-ray, and it suggests that the selection of a nuclide considering the range of the beta-ray is necessary in the treatment of target radionuclides in the future.

Estimation of the optimal heated inlet air temperature for the beta-ray absorption method: analysis of the PM10 concentration difference by different methods in coastal areas

  • Shin, So Eun;Jung, Chang Hoon;Kim, Yong Pyo
    • Advances in environmental research
    • /
    • 제1권1호
    • /
    • pp.69-82
    • /
    • 2012
  • Based on the measurement data of the particulate matter with an aerodynamic diameter of less than or equal to a nominal 10 ${\mu}m$ (PM10) by the ${\beta}$-ray absorption method (BAM) equipped with an inlet heater and the gravimetric method (GMM) at two coastal sites in Korea, the optimal inlet heater temperature was estimated. By using a gas/particle equilibrium model, Simulating Composition of Atmospheric Particles at Equilibrium 2 (SCAPE2), water content in aerosols was estimated with varying temperature to find the optimal temperature increase to make the PM10 concentration by BAM comparable to that by GMM. It was estimated that the heated air temperature inside the BAM should be increased up to $35{\sim}45^{\circ}C$ at both sites. At this temperature range, evaporation of volatile aerosol components was minor. Similar ($30{\sim}50^{\circ}C$) temperature range was also obtained from the calculation based on the absolute humidity which changed with ambient absolute humidity and chemical composition of hygroscopic species.

Feasibility study of β-ray detection system for small leakage from reactor coolant system

  • Jang, Jaeyeong;Jeong, Jae Young;Park, Junesic;Cho, Young-Sik;Pak, Kihong;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2748-2754
    • /
    • 2022
  • Because existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm·hr-1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.

극저준위 방사성 폐기물을 위한 효율적인 ${\gamma}$-선 및 ${\beta}$-선 측정 방법 개발 (Development of Effective ${\gamma}$-ray and ${\beta}$-ray Detection Methods For Low-Level Radioactive Wastes)

  • 곽성우;염유선;김호경;조규성;박주완;김창락;송명재
    • Journal of Radiation Protection and Research
    • /
    • 제26권4호
    • /
    • pp.393-398
    • /
    • 2001
  • 매년 병원에서 사용 후 폐기되는 비가연성 폐기물은 ${\gamma}$-선과 ${\beta}$-선을 방출하지만 방사능은 주변방사능 수준으로 매우 낮다. 이를 측정하기 위한 기존의 방법은 비효율적이고 복잡하므로, 좀더 간단한 방법이 긴요하다. 본 논문에서는 측정 방사선의 특성상 핵종에 따라 다른 측정방법을 사용하였는데, ${\gamma}$-선 방출 핵종은 표준시료로부터 효율곡선식을 도출하여 미지의 방사능을 측정하였다 ${\beta}$-선 방출 핵종은 Monte Carlo 시뮬레이션을 통해 계측 효율을 예측하고 표면장벽형계측기로 측정하여 미지의 방사능 양을 결정하는 새로운 방법을 제시하였다. 연구결과에 의하면 이론적 계산치와 표면장벽형 계측기를 이용하면 전처리를 필요로하는 액체섬광계수기를 이용하지 않고 또한 계측효율을 결정하기 위한 비경제적인 표준시료 측정시험과정 없이도 저에너지 방사선을 약 17% 오차 범위내에서 결정할 수 있다고 판단된다.

  • PDF

치아의 전베타 농도 및 감마선 방사능 평가 (Determination of Gross-${\beta}$ and ${\gamma}$-Ray Activity Concentrations of Human Tooth)

  • 정현자;강현경;김성환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권4호
    • /
    • pp.261-265
    • /
    • 2014
  • 10세에서 70세까지 국내 남녀를 7개 연령대별 그룹으로 구분한 후, 치아의 감마선 농도와 각 그룹별 전${\beta}$ 방사능 농도를 측정하였다. 전${\beta}$ 농도는 P10가스(아르곤 90%, 메탄 10%)를 충진한 Tennelec XLB 측정기로 측정하였으며, 감마선은 고순도 게르마늄 검출기를 사용하여 감마선분광분석법으로 측정하였다. 본 실험에서 측정된 여성의 전${\beta}$ 방사능 농도범위는 0.089~0.32 Bq/kg이었으며, 남성의 전${\beta}$ 방사능 농도범위는 0.13~0.26 Bq/kg이었다. 치아의 감마선분광분석 결과 자연방사성동위원소인 $^{40}K$, $^{208}Tl$, $^{228}Ac$$^{234}Th$가 검출되었으며, 측정된 감마선 방사선 농도는 각각 20.7, 21.9 3.88 및 5.24 Bq/kg 이었다. 본 연구 결과는 향후 후쿠시마 원전사고 등 불의의 방사선 누출 사고 등에 대비하여 정상 환경에서의 인체의 치아에 축적된 방사능 준위 데이터로 활용할 수 있을 것으로 사려된다.