• Title/Summary/Keyword: beta-ray

Search Result 619, Processing Time 0.025 seconds

Feasibility Study on Development of an Underwater Beta-ray Monitoring Sensor (수중 내 베타선 모니터링 센서 개발을 위한 기초연구)

  • Park, Hye Min;Joo, Koan Sik
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.333-336
    • /
    • 2016
  • In this study, a beta monitoring sensor was developed as a part of basic research for quantitative beta monitoring underwater, and its performance was evaluated using a calibration source. A beta detection sensor was manufactured by using SiPM(silicon photomultiplier) and $CaF_2$:Eu, YAG:Ce, YAP:Ce scintillator. A large-area light guide was introduced to improve beta-ray detection efficiency. As calibration sources, the Beta source $^{90}Sr$, which is the main fission product of a nuclear accident, and the gamma source $^{137}Cs$ are used. In the performance evaluation, it is confirmed that scintillator $CaF_2:Eu$ gives the highest beta-ray detection response. Compared to gamma ray, beta-ray detection responsivity and detection efficiency are verified. Therefore, this study is expected to contribute to basic research in the development of an underwater beta-ray monitoring system.

Plastic scintillator beta ray scanner for in-situ discrimination of beta ray and gamma ray radioactivity in soil

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1259-1265
    • /
    • 2020
  • A beta ray scanner was proposed for in-situ discrimination of beta and gamma ray radioactivity. This scanner is based on the principle that gamma and beta rays experience different changes in detection efficiency in scintillators with different geometries, especially with regard to the scintillator thickness. The ratios of the counting rates of gamma rays (Rgamma), beta rays (Rbeta), and sample measurements (Rtotal) in a thick scintillator to those in a thin one are reported. The parameter Xthick, which represents the counting rate contributed by beta rays to the total counting rate in the thick scintillator, was derived as a function of those ratios. The values of Rgamma and Rbeta for 60Co and 90Sr sources were estimated as 3.2 ± 0.057 and 0.99 ± 0.0049, respectively. The estimated beta ray contributions had relative standard deviations of 2.05-4.96%. The estimated range of the beta rays emitted from 90Sr was 19 mm as per the Monte Carlo N-Particle simulation, and this value was experimentally verified. Homogeneous and surface contaminations of 60Co and 90Sr-90Y were simulated for application of the proposed method. The counting rate contributed by the beta rays was derived and found to be proportional to the concentration of 90Sr-90Y contamination.

Chlorination of Phenyl Derivatives : Chlorination of ethyl -${\alpha},{\beta}-dichloro-{\beta}$-phenyl propionate under gamma ray irradiation (芳香族 誘導體의 염素化反應 Ethyl-${\alpha},{\beta}-dichloro-{\beta}$-phenyl propionate의 gamma 線 鹽素化反應)

  • Kim, You-Sun;Kim, Ki-Soo
    • Journal of the Korean Chemical Society
    • /
    • v.12 no.2
    • /
    • pp.55-60
    • /
    • 1968
  • Chlorination of aromatic derivatives under UV light and ${\gamma}$-ray irradiation was studied. Ethyl ${\alpha} ,{\beta} -dichloro-{\beta}$-phenyl propionate gave the p-chlorophenyl derivatives when chlorination was done under UV light. The same type of the product was obtained in the reaction where the mole ratio of the ester and chlorine was 1 to 2 and the chlorination was done under ${\gamma}$-ray irradiation. When the mole ratio of the ester and chlorine was 1 to 8, the chlorination reaction under ${\gamma}$-ray irradiation gave a poly-chlorinated derivatives which was identified as a side chain chlorinated p-chlorophenyl derivatives. Ethyl ${\alpha} ,{\beta} -dichloro-{\beta}$-(p-chlorophenyl) propionate gave the same type of the side chain chlorinated p-chloro derivatives by the chlorination under ${\gamma}$-ray irradiation, whereas ethyl ${\alpha} ,{\beta} -dichloro-{\beta}$-(o-chlorophenyl) derivatives gave o,p-dichlorophenyl derivatives. The identifications of the products were based on a radio thin layer chromatography and activation analysis of chlorine contents of product. The chlorination reaction was discussed in regards to the effect of phenyl substituents to the formation of reaction product and the procedures were described.

  • PDF

Simulation of Beta Rays from Tritium with Cathode Rays (음극선을 이용한 삼중수소 베타선 모사)

  • Kim, KwangSin;Lee, Sook-Kyung;Son, Soon-Hwan;Lim, Hoon;Lee, Dong-Hwan
    • Journal of Radiation Industry
    • /
    • v.2 no.3
    • /
    • pp.141-148
    • /
    • 2008
  • Beta rays emitted from tritium in titanium tritide film were simulated with cathode rays of a scanning electron microscope to investigate the effect of beta rays from tritium on semiconductor devices. The cathode ray currents, which vary with the change of applied energy and beam spot size, were measured with Faraday cup. The current from the semiconductor device irradiated with cathode rays at various conditions was measured. The cathode ray current increased with the increase of spot size to a maximum then decreased when the spot sized increased further. The magnitude of current produced in the semiconductor device is proportional to the magnitude of cathode ray current. The magnitude of cathode ray current at each energy level was matched to the intensity of beta ray to simulate the tritium beta ray spectrum. Then the semiconductor characteristics were analyzed with I-V curves.

The Effects on Escherichia coli and Plasmid DNA Using Ultrasoft X-ray (Ultrasoft X-ray의 Escherichia coli균과 plasmid DNA에 대한 영향)

  • ;;;;;Seiya Chiba;Atsuo Kimura
    • KSBB Journal
    • /
    • v.15 no.1
    • /
    • pp.84-87
    • /
    • 2000
  • We studied the effect of ultrasoft X-ray obtained from the Pohang Light Source (PLS), on the mutation of E. coli and the damage of plasmid. After irradiation, the supercoiled plasmid DNA converted to the relaxed-form, and then to the linear-form. We transformed the irradiated plasmid DNA and isolated $\beta$-galactosidase mutants. We also isolated $\beta$-galactosidase mutants from the directly irradiated cells. There were preferred mutational sites on DNA induced by ultrasoft X-ray.

  • PDF

Noise Reduction Method for Particle Measurement System using Beta-ray Absorption Method (베타선 흡수법을 이용하는 미세먼지 측정시스템을 위한 잡음제거 방법)

  • Choi, Hun;Sohn, Sang-Wook;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1706-1712
    • /
    • 2012
  • The Beta-ray absorption method (BAM) gives a good solution for measuring the mass concentration of atmospheric particles(PM10 and PM2.5). To determine particular matters (PM) concentration, a ratio of the number of detected beta-ray intensity passing through the clean filter and the dust-sampled filter is used. These intensity data measured in air pollution monitoring such as PM10 and PM2.5 usually contained the additive noise(thermal noise, power supply noise and etc.). Therefore, the estimation performance of mass concentration can be deteriorated by these noises. In this paper, we present a new noise reduction method that is essentially required to develope an automatic continuous PM monitoring system using beta-ray absorption method. By combining the block data averaging technique and curve fitting, in the proposed method, the additive noise can be reduced in the measured data. To evaluate the performance of the proposed method, computer simulations were performed with computer generated signals as the input.

Feasibility study of β-ray detection system for small leakage from reactor coolant system

  • Jang, Jaeyeong;Jeong, Jae Young;Park, Junesic;Cho, Young-Sik;Pak, Kihong;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2748-2754
    • /
    • 2022
  • Because existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm·hr-1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.

Determination of Gross-${\beta}$ and ${\gamma}$-Ray Activity Concentrations of Human Tooth (치아의 전베타 농도 및 감마선 방사능 평가)

  • Jeong, Hyunja;Kang, Hyun-Kyung;Kim, Sunghwan
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.261-265
    • /
    • 2014
  • The ${\gamma}$-ray concentration and gross-${\beta}$ activity by age group were measured in the teeth of males and females of the domestic residents. They were divided into 7 age groups from 10s to the age of 70s. The gross-${\beta}$ activity concentration was measured by using the Tennelec XLB measuring instrument filled with P10 gas (argon 90%, methane 10%). The ${\gamma}$-ray was measured through the ${\gamma}$-ray spectroscopic analytical method by using the high purity germanium (HPGe) radiation detector. The range of gross-${\beta}$ activity concentration was measured 0.089 to 0.32 Bq/kg in females and 0.13 to 0.26 Bq/kg in males. From the ${\gamma}$-ray spectroscopic analysis of the teeth, the natural radioactive isotopes of $^{40}K$, $^{208}Tl$, $^{228}Ac$ and $^{234}Th$ were detected and their measured ${\gamma}$-ray activity concentrations were found to be 20.7, 21.9, 3.88 and 5.24 Bq/kg, respectively.

Solubilization and Dissolution Enhancement of Benzimidazole Antnelmintic Drugs by Cyclodextrin Complexation (시클로덱스트린류와의 복합체 형성에 의한 벤즈이미다졸계 구충 약물의 용해성 및 용출 증가)

  • 전인구;박인숙
    • YAKHAK HOEJI
    • /
    • v.37 no.3
    • /
    • pp.216-227
    • /
    • 1993
  • Complex formations of practically insoluble antelmintic drugs such as mebendazole (MBZ), albendazole (ABZ) and flubendazole (FBZ) with dimethyl-$\beta$-cyclodextrin (DM-$\beta$-CyD) and 2-hydroxypropyl-$\beta$-cyclodextrin (HP-$\beta$-CyD) together with $\alpha$-, $\beta$- and $\gamma$-cyclodextrins(CyDs) in duffered solutions were investigated by solubility method. $A_{L}$ type phase solubility diagrams were obtained in all cases except for the complexation (B$_{s}$, type) of FBZ with $\gamma$-CyD. The highest stability constants were obtained with DM-$\beta$-CyD, followed by $\alpha$-CyD > $\beta$-CyD > HP-$\beta$-CyD > $\gamma$-CyD for ABZ, and HP-$\beta$-CyD > $\gamma$-CyD > $\beta$-CyD > $\alpha$-CyD for FBZ at pH 1.2. On the other hand, solid dispersion systems of ABZ and FBZ with $\beta$- and DM-$\beta$-CyDs were prepared by solvent evaporation method and evaluated by dissolution, differential thermal analysis and powder x-ray diffractometry. The dissolution rates of ABZ- and FBZ-DM-$\beta$-CyD solid dispersions were much faster than those of drugs alone, corresponding physical mixtures and tablets on market both at pH 1.2 and 6.8. Although dissolution rates of all samples at pH 6.8 were by far lower than those obtained at pH 1.2, as explained by pH-solubility profiles for ABZ and FBZ, the dissolution rates at pH 6.8 of ABZ from $\beta$- and DM-$\beta$-CyD solid dispersions exceeded the respective equilibrium solubility (23.9 $\mu\textrm{g}$/ml). Fast dissolution of ABZ from solid dispersions with CyDs was attributed to the reduction of drug crystallinity and particle size which was supported by DTA and powder x-ray diffractometry. Consequently these results suggest that solid dispersion systems with CyDs may provide useful means to markedly enhance the solubility and dissolution of benzimidazole antelmintic drugs.

  • PDF

Development of Effective ${\gamma}$-ray and ${\beta}$-ray Detection Methods For Low-Level Radioactive Wastes (극저준위 방사성 폐기물을 위한 효율적인 ${\gamma}$-선 및 ${\beta}$-선 측정 방법 개발)

  • Kwak, Sung-Woo;Yeom, Yu-Sun;Kim, Ho-Kyung;Cho, Gyu-Seong;Park, Joo-Wan;Kim, Chang-Lak;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.393-398
    • /
    • 2001
  • The non-combustible RI wastes disposed of in hospital every year emit ${\gamma}$-ray or ${\beta}$-ray but their activities are very low to the extent of background. Development of more simple methods is needed because the conventional detection methods are so ineffective and complex. In this study, to solve this problem, detection method using efficiency curve for ${\gamma}$-ray emitting radioactive wastes measurement is proposed and experimental detection efficiency equation is also determined through HPGe's standard specimen measurement. For ${\beta}$-emitting radioisotopes detection, new measurement method using detection efficiency estimated by Monte Carlo simulation and SBD measurements is also proposed. According to the results of this paper, the unknown activity of low-level radioactive wastes without LSC requiring the preparation of standard sample and measurement for standard source detection efficiency could be determined efficiently and simply about ${\pm}17%$ in errors by using the theoretical detection efficiency and the SBD measurement result.

  • PDF