• Title/Summary/Keyword: bent neck

Search Result 37, Processing Time 0.033 seconds

A Study of Loadings of Neck Muscles when Bent Backward (위보기 작업 시 EMG를 이용한 목 근육의 부하 평가)

  • Lee, Kwan-Suk;Park, Ju-Won
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.111-116
    • /
    • 2012
  • Workers who work with his neck bent backward in the standing posture have often complained of their musculoskeletal stress. The objective of this study was to find how much stress there was for workers who worked with their neck bent backward. The subjective evaluation and electromyography(EMG) were used to check the level of the stress. It was found that all subjects felt extreme pain after working with the neck bent backward and alternating 1 minute work and 0.5 minute rest for 30 minutes. The EMG level(amplitude) of neck muscles increased 80 percent on the average and the center frequency of EMG shifted to the lower frequency level which indicated fatigue of neck muscles. Thus, the intervention of this musculoskeletal stress is strongly recommended.

A Study for the Properties of Upper Body Somatotype of Lateral View for Middle-aged Women (중년여성의 상반신 측면체형 특성에 관한 연구)

  • 김소라
    • Journal of the Korean Home Economics Association
    • /
    • v.41 no.11
    • /
    • pp.1-9
    • /
    • 2003
  • The somatotype classification of this study was to manufacture well-fitted clothes for middle-aged women. The somatotype classification of the upper body of lateral view was based on previous studies, and 4 postures, straight posture, leaning back posture, bent forward posture, and swayback posture were selected for this study. The front of leaning back posture was longer and wider than that of straight posture, and its front neck depth was deeper. Its front interscye breadth was wider and back interscye breadth was narrower. S.N.P. B.P. front waistline length, waist front length, front diagonal length, chest shedder length, front waistline shoulder line length were longer, and S.N.P. scapular back waistline length, back length, back shoulder length, back diagonal length, shoulder line back waistline length were shorter. On the contrary, the front of bent forward posture was shorter and narrower than that of straight posture, and its back neck depth was deeper. The properties of swayback posture were similar to those of bent forward posture. Its front was shorter and narrower, but the results of front neck depth and back neck depth were like those of straight posture.

A Study of Crane Operators' Overexertion of Neck Muscles (크레인 작업자의 목 부하 연구)

  • Oh, Sae Loom;Lee, Kwan Suk
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.81-87
    • /
    • 2013
  • Crane operators usually work with their necks bent forward in a seating position for a long period. They have complained of their musculoskeletal stress at their necks. The objective of this study was to find the level of stress at the neck when crane operators bend their neck forward during their work. Experiments were conducted in the laboratory where subjects bent their necks forward for 1 minute and took a rest for 0.5 minute and repeated this performance for 60 minutes. Subjective evaluation using Borg's CR-10 scale and electromyography (EMG) were used to check the level of the stress at the neck. Subjects reported that the level of pain at the end of 60 min. experiment was close to the extreme pain(level 8.95). The EMG level(amplitude) increased 80% on the average and the center frequency of EMG shifted to the lower frequency level which indicated fatigue of neck muscles. Thus, it was found that there is quite much neck stress for crane operators when they maintain their neck posture of bending forward for a long time during their work. This information will be a basis in searching for an intervention measure for the crane operators' neck stress.

The Effects of Sitting Posture on Cervical Flexion Angle and Pain during Smart Phone Use in Young Adults

  • Chun, Hye-Lim;Kim, Kyung-Hun;Choi, Bo-Ram
    • Journal of Korean Physical Therapy Science
    • /
    • v.24 no.3
    • /
    • pp.56-63
    • /
    • 2017
  • Purpose: This study aimed to investigate the effects of sitting posture on cervical flexion angle and pain during smart phone use. Method: This research was performed on 10 adult female students who use smart phones regularly, Each of the two groups of participants used the provided smart phone for 20 minutes while maintaining the given default posture. The evaluation order was randomly selected and the two groups were photographed twice before and after the experiment and were asked to answer if they felt pain during or after the experiment. Result: First, both upright sitting position and vertebra bent position pre and post experiment readings showed significant statistical difference (p<.05). And it is shown to be a factor that induces pain around the neck via increase in neck flexion angle. Second, although there were no significant statistical difference between the pre and post experiment readings of the upright sitting position results and the vertebra bent position results, the vertebra bent position readings showed bigger changes to the neck flexion angle then the upright sitting position readings. Third, all participants from both groups claimed pain in all the tested postures of smart phone usage. Conclusion: Smart phone usage for an extended amount of time in all body postures may prove to have a negative effect making the "optimal" smart phone usage position as a controlled time with neck stretches included in between short sessions.

Effect of Transportation Conditions and Plant Growth Regulator on the Maintenance of Freshness and Quality of Cut Chrysanthemum 'Baekma' (절화국화 '백마'의 수송조건 및 생장조절제 처리가 선도유지 및 품질에 미치는 효과)

  • Suh, Jeung Keun;Kim, Ji Hee;Kim, Kyoung Ok
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.4
    • /
    • pp.206-211
    • /
    • 2011
  • This study was carried the effect of transportation conditions and plant growth regulator on the maintenance of freshness and quality of cut Chrysanthemum 'Baekma'. The quality of cut chrysanthemum 'Baekma' which were stored at $5^{\circ}C$ was better than those of stored at $20^{\circ}C$ and control. When cut mum 'Baekma' was transported stacking boxes with vertical condition after dipping in distilled water, flowering degree, flower size, days to flower appearing degree, and bent neck were delayed. Flowering degree was delayed by $10mg/L^{-1}$ uniconazole spraying, The days to bent neck was delayed by 1,000x daminozide spraying.

Effect of Chitosan and Sucrose on the Vase Life of Cut Rose 'Cardinal' (장미 'Cardinal'의 절화수명에 미치는 키토산과 Sucrose의 영향)

  • Yoo, Yong Kweon;Park, Hyun Jin;Kang, Sang Wook;Kim, Hyun Kyung
    • Horticultural Science & Technology
    • /
    • v.17 no.4
    • /
    • pp.481-484
    • /
    • 1999
  • This experiment was conducted to examine the effects of chitosan and sucrose on the vase life of cut rose (Rosa hybrida L. cv. Cardinal). Addition of 5 mg/L chitosan and 3% sucrose to the holding solution prolonged the vase life for 3 days as compared to the control, and improved quality of cut rose in flower diameter and fresh weight. Development of bent-neck was delayed by supply of 2 mg/L or 5 mg/L chitosan and 3% sucrose about 2 or 3 days. When 3% sucrose was added to the holding solution, the rate of water absorption more slowly decreased compared to the other treatments.

  • PDF

Research on the Subjective Symptoms of Musculoskeletal Disorders for Dental Hygienists in Daegu (대구지역 치과위생사의 근골격계 질환 자각증상 실태에 관한 조사연구)

  • Kim, Byung-Tae;Choi, Hwa-Young;Moon, Seon-Jeong
    • The Korean Journal of Health Service Management
    • /
    • v.8 no.4
    • /
    • pp.121-130
    • /
    • 2014
  • To devise a plan to efficiently control and cope with musculoskeletal disorders, this study conducted a self-administered survey among dental hygienists working at dental clinics in Daegu. The data were collected from December 1, 2013 to February 28, 2014, and drew the following conclusions. For body posture for medical procedures, at lower levels in their careers, the hygienists' head and back were more bent; at higher levels in their careers, the their shoulders, body and hips were more bent; and at higher levels in their careers, their assistance posture in general was more bent. Hygienists with longer years of experience had more pain in the neck and the arms/elbows. Respondents engaged in medical treatment services were more likely to have pain in their arms/elbows, and those engaged in assisting in medical treatment and consulting and insurance services were more likely to have pain in their necks. It is necessary to recognize the seriousness of musculoskeletal disorders, provide specific education through supplementary training and relevant seminars, and avoid repetitive use of the same muscle or joint through environmental improvement of dental clinics, and personal efforts should be made to maintain good posture.

Analysis of Neck Fit-zone according to Body Type for Females in Their 60s (60대 여성 체형별 목 부위 피트존 분석)

  • Park, Sunhee;Hong, Kyunghi;Lee, Yejin
    • Fashion & Textile Research Journal
    • /
    • v.20 no.4
    • /
    • pp.429-438
    • /
    • 2018
  • This study analyzed the fit-zone of the neck for females in their 60s. We considered the standard body types of females in their 60s and the four body types from the sixth Size Korea. The results of the study were as follows. We could not determine a pattern formula for the neck based on the changes in the body type of females in their 60s. However, the position of the lateral neck point generally showed a significant difference from that of females in their 20s. In the case of the shoulder angle, the point of the shoulder was angled slightly towards the back in all body types. It was also found that the curve of the neck circumference for both the collar and the bodice should have been smoother than what was shown on the 3D shape. The larger the height difference between the point of the back of the neck and the lateral neck point in the 3D shape, the smoother the design should be at the curve of the circumference at the front of the neck. A larger curvature in the front radius of the 3D shape increased the difference in the shape of the curve between the collar and the basic pattern of the bodice. Hence, a more careful design is required for these parts of the pattern. In addition, the more the front neck is bent, the smoother the circumference curve should be in the pattern design at the front of the neck and the collar.

Partial fetotomy: technique to resolve wry neck dystocia in mare

  • Hassan, Mubbashar;Shahid, Sana;Asif, Akhtar Rasool;Naveed, Muhammad Ilyas;Shahzad, Abid Hussain;Khan, Mumtaz Ali
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.35 no.4
    • /
    • pp.366-369
    • /
    • 2020
  • Foaling is a process of giving birth to foal which is prompt and forceful event in equine breeding. Dystocia is declared when 2nd stage of parturition exceeds from 20 min without fetal movements in mare. Dystocia is very challenging situation for both mare and veterinarian. Survivability of mare and foal, and subsequent fertility of mare depends on efficient management. Therefore, the current report described a rare case of wry neck (torticollis or unilateral bent neck) resulted in dystocia, that was efficiently resolved by partial fetotomy and repulsion technique in mare under field conditions. Intensive post operative care was performed to avoid infection and to achieve fertility subsequently.

Effect of Pretreatments and Holding Solutions on Vase Life and Quality of Cut 'Saphir' Rose (전처리와 보존용액이 절화장미 'Saphir'의 수명과 품질에 미치는 영향)

  • Bang, Chang-Seok;Lee, Jong-Suk;Song, Cheon-Young;Song, Jeong-Seob;Huh, Kun-Yang
    • Horticultural Science & Technology
    • /
    • v.17 no.6
    • /
    • pp.758-760
    • /
    • 1999
  • This experiment was carried out to investigate the effect of pretreatments and holding solutions on quality and vase life of cut 'Saphir' rose (Rosa hybrida L.). Pulsing with aluminum sulfate or NaOCl prolonged vase life held in HQS+sucrose+ethionine. Solution absorption held in distilled water were more increased than held in HQS+sucrose+ethionine. Holding solution with 8-hydroxyquinoline sulfate (HQS)+sucrose+ethionine increased fresh weight compared with distilled water except pulsing with STS+sucrose. Pulsing with aluminium sulfate delayed bent-neck held in HQS+sucrose+ethionine. Flower diameter and dry weight of petal held in HQS+sucrose+ethionine were more increased than held in distilled water except pulsing with STS+sucrose. There were no significance in Hunter color value 'L' and value 'a', but value 'b' was decreased held in distilled water.

  • PDF