• Title/Summary/Keyword: bending endurance test

Search Result 21, Processing Time 0.037 seconds

Relationship between Tensile Characteristics and Fatigue Failure by Folding or Bending in Cu Foil on Flexible Substrate (유연성 기판에 사용되는 전해 동박의 절곡 및 굴곡 피로 파괴와 인장 특성과의 관계)

  • Kim, Byoung-Joon;Jeong, Myeong-Hyeok;Hwang, Sung-Hwan;Lee, Ho-Young;Lee, Sung-Won;Cbun, Ki-Do;Park, Young-Bae;Joo, Young-Cbang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.1
    • /
    • pp.55-59
    • /
    • 2011
  • Folding endurance, bending fatigue and monotonic tensile tests of 4 kinds of Cu foil on flexible substrate was performed to investigate the relationship between folding or bending endurances and tensile characteristics. The repeated 5.3 or 2.0% strain was applied to Cu foil in folding endurance test or bending fatigue test while monitoring the electrical resistance. Elastic modulus, yield strength, ultimate tensile strength, ductility, and toughness were obtained by monotonic tensile test on the same samples. The Cu foil with higher toughness and ductility showed higher reliabilities in folding or bending fatigue. However, elastic modulus and yield strength did not show any relationship with folding and bending reliability. This is because the failures of Cu foil by folding or bending fatigue were closely related to the fracture energy of metal.

Modifying a Back Endurance Test for Examining Erector Spine Muscles by Adding Lateral Trunk Bending and Trunk Rotation

  • Park, Se-Yeon;Park, Du-Jin
    • PNF and Movement
    • /
    • v.15 no.3
    • /
    • pp.381-387
    • /
    • 2017
  • Purpose: Although some studies indicate that the Sorensen test may not be used to examine back muscles such as the erector spinae, alternatives to the back-extension test are rarely suggested. Therefore, the purpose of the present study was to investigate an effective way to stimulate the erector spinae muscles by adding a component of trunk rotation and lateral bending to general back extensions. Methods: A total of 18 healthy, physically active participants performed simple trunk extension, extension with trunk rotation, and extension with lateral bending. Surface electromyography responses of the latissimus dorsi, thoracic, and lumbar levels of the erector spinae; the gluteus maximus; and the biceps femoris muscles were investigated during these 3 conditions of modified back extension tests. Results: The simple trunk extension exercise caused significant increases in activity of the gluteus maximus and biceps femoris muscles as compared to the extension with rotation and lateral bending exercises. The extension with trunk rotation exercise showed significantly greater activation in the thoracic and lumbar levels of the erector spinae and in the latissimus dorsi as compared to the other exercises. The index measuring subjective difficulty was significantly lower in the simple trunk extension exercise as compared to the extension with trunk rotation and extension with lateral bending exercises. Conclusion: The present study suggests that extension with trunk rotation has the advantage of stimulating the para-spinal muscles, while simple trunk extension may not be adequate to selectively simulate the para-spinal muscles but may be appropriate for examining global trunk extensors.

Mechanical strength of Zirconia Abutment in Implant Restoration (지르코니아 임플란트 지대주의 기계적 강도에 관한 연구)

  • Shin, Sung-ae;Kim, Chang-Seop;Cho, Wook;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.349-360
    • /
    • 2009
  • Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.

Bending fatigue strength comparison of specimen and actual gear for Korea High-Speed Train (한국형 고속전철용 기어의 시편 및 실물 피로강도 평가)

  • 이동형;서정원;문경호;최경진
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.399-403
    • /
    • 2002
  • The transmission system of high speed train serve in the severe condition compared with those of other trains, namely, they have to transmit high power to run with high speed and they have to make maximum use of the limited space. To clarify the strength of gear for Korea High-Speed Train, a bending fatigue test of gear specimen is performed and compare with actual gear's. From this result, specimen test is useful to infer S-N curve and endurance limit of actual gear that much time and expense are consumed.

  • PDF

Influence of Implant Fixture-Abutment Connection and Abutment Design on Mechanical Strength (임플란트 고정체-지대주 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향)

  • Chun, Mi-Hyun;Jeong, Chang-Mo;Jeon, Young-Chan;Eom, Tae-Gwan;Yoon, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.269-281
    • /
    • 2008
  • Fatigue or overload can result in mechanical problems of implant components. The mechanical strength in the implant system is dependent on several factors, such as screw and fixture diameters, material, and design of the fixture-abutment connection and abutment. In these factors, the last rules the strength and stability of the fixture-abutment assembly. There have been some previous reports on the mechanical strength of the fixture-abutment assembly with the compressive bending test or short-term cyclic loading test. However, it is restrictive to predict the long-term stability of the implant system with them. The purpose of this study was to evaluate the influence of the design of the fixture-abutment connection and abutment on the mechanical strength and failure mode by conducting the endurance limit test as well as the compressive bending strength test. Tests were performed according to a specified test(ISO/FDIS 14801) in 4 fixture-abutment assemblies of the Osstem implant system: an external butt joint with Cemented abutment (group BJT), an external butt joint with Safe abutment (group BJS), an internal conical joint with Solid abutment (group CJO), and an internal conical joint with ComOcta abutment (group CJT). The following conclusions were drawn within the limitation of this study. Compressive bending strengths were decreased in order of group BJS(1392.0N), group CJO(1261.8N), group BJT(1153.2N), and group CJT(1110.2N). There were no significant differences in compressive bending strengths between group BJT and group CJT(P>.05). Endurance limits were decreased in order of group CJO(600N), group CJT(453N), group BJS(360N), and group BJT(300N). 3. Compressive bending strengths were influenced by the connection and abutment design of the implant system, however endurance limits were affected more considerably by the connection design.

Fatigue Life Evaluation of the Plastic Gear (플라스틱 기어의 피로수명 평가 및 수명 예측)

  • Chong Tae Hyong;Kang Sung Kyu;Ha Young Wook
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.239-245
    • /
    • 2005
  • Through the fatigue test of plastic gears using polyacetal polymer, this research aims at providing basic data for not only specifying operation conditions of plastic gears, but also designing dimensions of plastic gears with giving fatigue life and the estimated equation of fatigue life of plastic gears. That is, from the fatigue life curves, the estimated equation of fatigue life of plastic gears is taken out. For the estimated equation of fatigue life of plastic gears, this research provides two test methods; one is preserving non-limited temperature of tooth flank, the other is preserving limited temperature of tooth flank. As results, how the temperature of tooth flank affects the fatigue life is shown. In addition, based on the endurance limit, the essential factors of the unit load and K-factor are determined, which are needed in the design of gear by bending strength and surface durability.

  • PDF

Fatigue Fracture of NBR-coated SUS301 Thin Plate for MLS Gasket (MLS 가스겔용 NBR 피복 SUS301 박판의 피로파손)

  • Han, Byoung-Kee;Cho, Sung-San;Chang, Hoon;Kim, Beom-Keun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.4
    • /
    • pp.207-212
    • /
    • 2004
  • Full-beads of multi-layer steel engine head gaskets that are used to seal the combustion gas between the head and the block are subject to cyclic bending stresses due to the variation of the head/block gap during engine operation. The S-N curve for the fatigue durability assessment of the full-bead formed on NBR-coated SUS301 thin plate is deduced from the axial fatigue test results because of the difficulty in conducting the bending fatigue test of thin plate. The experimental verification of the deduced S-N curve is presented. It is shown that the NBR coating increases the endurance limit of the plate significantly. Mechanism of crack nucleation and propagation in the full-bead is discussed with photographs of the fatigue cracks.

The Prediction of Failure Load for an Unsymmetrically Stiffened Circular Composite Spar (비대칭으로 보강된 복합재 원형 스파의 파손하중 예측)

  • Kim, Sung Joon;Lee, Donggeon;Park, Sang Wook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.7
    • /
    • pp.505-511
    • /
    • 2020
  • The circular composite tubes have been used as a main spar of HALE-UAV(High Altitude Long Endurance-Unmanned Air Vehicle). In this paper, an analytical model is presented for the prediction of the failure load of unsymmetrically stiffened circular spar using a modified Brazier approach. This model was used to predict the moment carrying capacity of the unsymmetrically stiffened circular spar. From the results, we can know that a stiffened cap placed in the top sector of a spar increased the bending capabilities. Four point bending tests were conducted to estimate the effect of the cap on the failure load and compared with the proposed model. And numerical simulations were performed to analyze the behavior of stiffened circular spar. Comparisons of the results from the proposed model with those from experiments and numerical modes show good correlation.

Effect of cold working and stabilizing treatment on the fatigue properties of aluminum alloy 5083 (알루미늄합금판재(Al5083)의 피로특성에 미치는 냉간압건량과 안정화처리의 영향)

  • 이재순;오택열;박경순
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.31-40
    • /
    • 1983
  • A study was made of the effect of cold working and stabilizing temperature on the fatigue properties of Aluminum alloy 5083. The amount of cold working ranged from 14% to 35% and stabilizing temperature was 120.deg. C-160.deg. C. Rotary bending fatigue test was carried out, and it was found that 1) E specimen that had been cold worked by the cold reduction of 35% and stabilized at 160.deg. C for 2 hours was showed the most excellent fatigue limit and endurance ratio and, 2) By the results of the between crack propagation behavior and stress intensity factor, E specimen was showed the better resistance to fatigue crack growth than others.

  • PDF

The Effect of Structure on the Fatigue of Low Carbon Steel (조직변화(組織變化)가 피로현상(疲勞現象)에 미치는 영향(影響))

  • C.S.,Kang;C.M.,Suh
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.9 no.2
    • /
    • pp.33-42
    • /
    • 1972
  • This paper was studied on the behavior, crack formation and propagation of slip bands on low carbon steel which was heat-treated in three conditions in order to change metallic structure. The specimens were tested by rotating bending fatigue testing machine and also observed the variations of grains by microscope. From the test results it was clear that fatigue endurance limit and life of low carbon steel were more increased in contrast with the case that the grain size of specimen was more decreased. Slip bands developed at oil-quenched specimen and furnace-cooled specimen. Formed cracks in the first one or two grains below the surface were approximately "planar" type, there after they followed "wavy" type. It was also found that cracks at 30% higher stress than fatigue limit were usually developed inter-granular, and cracks at 12% higher stress than fatigue limit were propagated meandering path, partly trans- and partly inter-grandular.

  • PDF