• Title/Summary/Keyword: bed temperature

Search Result 1,039, Processing Time 0.027 seconds

NOx Reduction with Secondary Air and Fuel in a Catalytic Combustor (촉매연소기에서 2단 공급공기와 연료가 NOx 저감에 미치는 연구)

  • 정진도;이보영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.541-549
    • /
    • 2003
  • A basic experimental study was conducted in order to find the optimum combustion control technology to decrease the thermal NO$_{x}$, by applying the catalytic combustion method with natural gas. NO$_{x}$ emission increased with increasing space velocity due to temperature rising in the furnace. In order to overcome the low resistance to high temperature, secondary air was supplied to the CST combustor. The following secondary fuel formed combustible mixture in part, which resulted in steep increase of the exiting temperature of the 2nd catalyst bed. It led to the more generator of NO$_{x}$, 30∼60% of the 1 st catalyst bed. It might be due to the potential increase of thermal NO$_{x}$.

Effect of heating temperature to remove NOx by sludge pellet (Sludge Pellet의 NOx제거특성에 미치는 온도의 영향)

  • Kim, Young-Ju;Park, Jae-Yoon;Park, Hong-Jae;Song, Won-Seob;Park, Sang-Hyun;Bae, Myung-Whan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.922-926
    • /
    • 2002
  • In this paper, in order to investigate the catalytic effect of the sludge exhausted from waterworks as heating temperature for NOx removal, we measure NO, $NO_2$ concentration as increasing temperature of sludge pellets and applying high voltage to sludge pellets in a quartz-glass reactor at the same time. NO initial concentration is 100ppm balanced with air gas in a mixing chamber. The gas flow is 5[l/min] and the heating temperature of sludge pellets in a quartz-glass reactor is adjusted from $200[^{\circ}C]$ $400[^{\circ}C]$ to investigate the effect of sludge pellets for removal NOx$(NO+NO_2)$ as increasing temperature. $BaTiO_3$ pellets is filled in a packed-bed reactor for corona discharge to measure how much NOx$(NO+NO_2)$ is removed after generating $NO_2$ from the packed-bed reactor. AC[60Hz] voltage is supplied to the reactor for discharge. In the result, $NO_2$ concentration is decreased by sludge pellets without heating temperature for sludge pellets in case of sludge pellets done heat treatment, however NO concentration is almost the same to be compared NO initial concentration. As increasing heating temperature for sludge pellets, $NO_2$ adsorbed on the sludge surface done heat treatment is converted to NO by the thermal energy, so NO concentration is extremely increased by reduction decomposition of $NO_2$. Finally, We think the sludge is possible to use for reduction catalysts, however we need to study more about the possibility and endurance of sludge as catalysts for NOx removal.

  • PDF

The Mixed-Bed Ion Exchange Performance and Temperature Effects at Ultra-Low Concentrations - 2.Temperature Effects - (초저이온 농도범위에서 혼합층 이온교환능과 온도의 영향 - 2. 온도의 영향 -)

  • Yoon, Tae Kyung;Noh, Byeong Il;Lee, Chang Won;Moon, Byung Hyun;Lee, Gang Choon;Jo, Myung Chan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.206-211
    • /
    • 1999
  • Mixed-bed ion exchange performance was studied experimentally with variations of cation to anion resin ratio, resin weight and temperature at ultralow sodium chloride solution concentrations of less than $1.0{\times}10^{-4}M$. Analyzing the effluent concentration histories the performance test was examined as a function of tested solution volume for a laboratory-scale continuous flow column until both the cation and anion-exchange resins were exhausted. Initial leakage was observed for both cation and anion breakthrough curves, but serious at cation breakthrough curve because of low selectivity coefficient. The slope of breakthrough curve was affected by selectivity coefficient and temperature. The slope of anion breakthrough curve was steep because of the large selectivity coefficient, and ion exchange rates increased as temperature increased. The temperature effect decreased as the total volume was increased or as the resins were exhausted.

  • PDF

Characteristics of Bio-oil derived from Quercus Acutissima in a Fluidized Bed Pyrolyser (유동층 열분해로에 의하여 생산된 상수리나무 바이오오일의 특성)

  • Lee Sun-Hoon;Eom Min-Seop;Yoo Kyung-Seun;Lee Young-Soo;Kim Nam-Chan;Lee See-Hoon;Lee Jae-Goo;Kim Jae-Ho
    • Resources Recycling
    • /
    • v.15 no.1 s.69
    • /
    • pp.3-11
    • /
    • 2006
  • Fast pyrolysis of Quercus acutissima was carried out in a fluidized bed pyrolyser and then the physicochemical properities of obtained bio-oil were analyzed using GC/MS. The yields of bio-oil of Quercus acutissima and Larix leptolepis from a fluidized bed pyrolyzer were maximized at $350^{\circ}C\;and\;400^{\circ}C$, respectively. This is due to the difference or cellulose content between the two tree species. Above the optimum temperature, the yields of char and oil decreased as the reaction temperature increased, but the yield of gas-phase and water fraction increased. It is concluded that this phenomenon is occured by secondary pyrolysis in the free board. The feeding rate of the sample in a fluidized bed pyrolyser did not affect the yields and composition of products, because of a sufficient mixing between bed materials and sand.

The Characteristics of Desulfurization using Metal Oxides in a Fluidized Bed Reactor (금속산화물을 이용한 유동층반응기에서 배연탈황특성)

  • Park, Tae Sung;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.9 no.2
    • /
    • pp.278-285
    • /
    • 1998
  • In a fixed bed reactor, adsorption capacity of $SO_2$ in simulated flue gases was investigated with NMO(natural manganese ore), composed of various metal oxides, iron ore and $CuO/{\gamma}-Al_2O_3$ as adsorbents. The experiment carried out in a fluidized bed reactor with variables such as gas velocity, temperature and particle size. Iron ore was excluded in the fluidized bed reactor experiment for the lower adsorption capacity. The adsorption of $SO_2$ in metal oxide is a typical chemisorption because the adsorption capacity of all adsorbents increased with temperature. The effect of particle size on the adsorption capacity was varied with the ratio, $U_o/U_{mf}$ and the difference of $U_o-U_{mf}$. $U_o$ is the gas velocity, $U_{mf}$ is the minimum fluidization gas velocity. $U_o/U_{mf}$ and $U_o-U_{mf}$ explain the behavior of the gas and solids in the fluidized bed reactor. From the performance equation of the fluidized bed reactor, kinetic reaction rate constants were obtained by the non-linear least square method. The adsorption capacity of NMO proved the potential use of $SO_2$ adsorbents.

  • PDF

A Study on the Contents of Fundamental Nursing Practice (기본간호학 실습교육현황과 실습내용 개선을 위한 조사 연구)

  • 이영휘;서화숙
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.3
    • /
    • pp.650-661
    • /
    • 1998
  • The purpose of this study was to provide fundamental data for determining contents of Fundamental Nursing Practice and developing desirable bedside nursing techniques for clinical nursing areas. Subjects for this study were 86 nurses who were employees of two university hospitals located in Seoul and a district area. Data were collected by questionnaires. Items of Fundamental Nursing Practice were classified into 72 items according to the result from content analysis of 9 textbooks of Fundamental Nursing. The results are as follows : 1) Items which above 80% of respondents practiced during the school inside practice or clinical nursing practice course were axillary temperature measurement, radial pulse measurement, respiratory rate measurement, application of oral hygiene, hand-washing technique, application of hot and cold bags, intramuscular injection technique, open bed-making, soap enema method, application of nelaton catheterization and oral and nasal suction methods. 2) Above 90% of respondents replied that all items except temperature measurement and bed-making were requisite contents for Fundamental Nursing Practice. Above 10% of respondents replied oral and rectal temperature measurement and bed-making were unnecessary content. 3) Above 90% of respondents replied that operating methods of all items except isolation technique, admission and discharge procedures, and retention enema in the Fundamental Nursing Practice course and clinical situation were consistent. The main reasons that respondents did not apply methods which they learned in the Fundamental Nursing Practice course to the clinical situation were 'insufficient time', 'colleagues were using different methods', 'insufficient supply of instuments' or 'inappropriate appliances'.

  • PDF

Numerical Study on High Temperature CO-Shift Reactor in IGFC (고온수소 전환 반응기에 관한 수치해석적 연구)

  • SEO, DONG-KYUN;LEE, JIN-HYANG;CHI, JUN-HWA;HONG, JIN-PYO;OH, SUK-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.324-330
    • /
    • 2018
  • In this study a numerical study was conducted to show flow, temperature and gas distributions in a high temperature CO shift reactor which was designed specially for energy saving and then evaluated with the related experiment. Mole fractions of syngas at the end of the catalyst bed were predicted with various assumed pre-exponential factors, were compared with the corresponding experimental results and $10^8$ was finally selected as the value. With the selection, a base case was examined. It was calculated that the inlet duct attached asymmetrically to the CO shift reactor affects on the distribution of the upward momentum (+z directional). In addition, CO conversion ratio is achieved up to 90% in the catalyst bed and especially it reached up to 70% at the initial part of catalyst bed.

Effects of Temperature, Pressure, and Gas Residence Time on Methane Combustion Characteristics of Oxygen Carrier Particle in a Pressurized Fluidized Bed Reactor (가압 유동층 반응기에서 산소공여입자의 메탄 연소 특성에 미치는 온도, 압력 및 기체체류시간의 영향)

  • Ryu, Ho-Jung;Park, Sang-Soo;Moon, Jong-Ho;Choi, Won-Kil;Rhee, Young-Woo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.2
    • /
    • pp.173-182
    • /
    • 2012
  • Effects of temperature, pressure, and gas residence time on methane combustion characteristics of mass produced oxygen carrier particle (OCN706-1100) were investigated in a pressurized fluidized bed reactor using methane and air as reactants for reduction and oxidation, respectively. The oxygen carrier showed high fuel conversion, high $CO_2$ selectivity, and low CO concentration at reduction condition and very low NO emission at oxidation condition. Moreover OCN706-1100 particle showed good regeneration ability during successive reduction-oxidation cyclic tests up to the 10th cycle. Fuel conversion and $CO_2$ selectivity decreased and CO emission increased as temperature increased. These results can be explained by trend of calculated equilibrium CO concentration. However, $CO_2$ selectivity increased as pressure increased and fuel conversion increased as gas residence time increased.

A Study of Desulfation Characteristics of Circulating Fluidized Bed Combustion for Domestic Anthracite (국내 무연탄의 순환류동층 보일러에서 탈황 특성 연구)

  • 정진도;김장우;하준호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.429-436
    • /
    • 2004
  • Circulating fluidized bed combustion (hereafter CFBC) technology enables an efficient combustion for the materials with low heating values such as high ash coal and sludges. It also has desulfation function by adding limestone directly to combustor. The CFBC has been considered as one of the best processes for low grade coal containing with large contents of ash and sulfur. In this paper, in order to various tests were performed to find the optimum desulfation condition for CFBC using Korean Anthracite. We surveyed possible parameters and conducted desulfation efficiency test in D Thermal Power Plant. In addition, the result of some fundamental theoretical consideration was discussed with CFBC. Optimum limestone size could be considered to be 0.1-0.3mm irrespective of combustion temperature and Ca/S molar ratio variation. Desulfation efficiency increased as the molar ratio increased. Because desulfation process occurs at the surface at higher temperature, inner side of limestone can't be utilized. When surface area is not appropriate, some SO$_2$ emit without reaction. Optimum molar ratio should be decided after considering chemical and physical properties of limestone and coal thoroughly such as particle size, pore size and HGI. Commercial CFBC is operated at Ca/S 1.6. Combustor temperature 840-87$0^{\circ}C$ shows good desulfation efficiency.

The Characteristics of Desulfurization for Dry-Type High Temperature in a Fluidized Bed Reactor (고온건식탈황을 위한 유동층반응기 특성연구)

  • 장현태
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.78-85
    • /
    • 1999
  • The removal characteristics of H$_2$S from IGCC process over the natural manganese ore(NMO) containing several metal oxides($MnO_x$ : 51.85%, $FeO_y$ : 3.86%, CaO : 0.11%) were carried out in a batch type fluidized bed reactor(I.D.=40mm, height=0.8m). The $H_2S$ breakthrough curves were obtained as a function of temperature, initial gas velocity, initial gas concentration, and aspect ratio. The effect of particle size ratio and particle mixing fraction on $H_2S$ removal were investigated with binary system of different particle size. From this study, the adsorption capacity of $H_2S$ increased with temperature but decreased with excess gas velocity. The breakthrough time for $H_2S$ is reduced as the gas velocity is increased which leaded to gas by-passing and gas-solid contacting in a fluidized bed reactor. The results of the binary particle system with different size in batch experimental could predict to improve the behavior of continuous process of $H_2S$ removal efficiency. The natural manganese ore could be considered as potential sorbent in $H_2S$ removal.

  • PDF