• 제목/요약/키워드: bearing strength

검색결과 994건 처리시간 0.05초

준설토의 건조수축에 의한 강도증가 특성과 지지력에 관한 연구 (A Study on Characteristics of Strength Increase and Bearing Capacity in Dredged and Reclaimed Soil due to Desiccation Shrinkage)

  • 유남재;이종호;이명욱;김현주
    • 산업기술연구
    • /
    • 제20권A호
    • /
    • pp.101-111
    • /
    • 2000
  • This research is results of experimental and numerical works on characteristic of strength increase and bearing capacity in dredged and reclaimed soil due to desiccation shrinkage. For a soil sampled from southern coastal area in Korea, basic soil property tests and standard consolidation test with falling head permeability tests were carried out to obtain consolidational characteristics of soil. Double cone penetration test, laboratory vane test and unconfined compression test were also performed to investigate the change of shear strength with degree of desiccation. Model tests were performed in 1G environment and 30G level artificially accelerated condition by using the centrifuge model test facilities to investigate the bearing capacity of desiccated ground. Test results were analyzed by using the theoretical and load-settlement characteristics method proposed by Meyehof & Hanna(1978). On the other hands, the numerical technique, using the finite strain consolidation theory considering the effect of desiccation was used to estimate the appropriate time of using heavy construction equipments in field with respect to strength increase due to desiccation.

  • PDF

스틱모델에 의한 차체 경량화 설계 (Light weight vehicle design by stick model)

  • 김천욱;김지홍
    • 오토저널
    • /
    • 제12권5호
    • /
    • pp.97-106
    • /
    • 1990
  • A method of weight evaluation of the load-bearing structural elements of cars is presented and the weight ratio of the analysis model is investigated. Replacing the materials of floor elements of the car into the high-strength steel, a considerable weight-reduction of the model has been obtained. The 1500cc model is selected for the present study and the stick model analysis is employed for the structural analysis. The torsional stiffness of the weight-reduced model is also evaluated and it is shown it has a reasonable rigidity. The ratio of the weight of the load-bearing structural elements to the unladen vehicle weight of cars is about 0.12for the 1500cc model and the weight-reduction of this study can be obtained around 17% of the weight of the load-bearing structural elements.

  • PDF

납심의 온도상승효과를 고려한 납-고무받침(LRB)의 비탄성응답 평가 (Inelastic Response Evaluation of Lead-Rubber Bearing Considering Heating Effect of Lead Core)

  • 양광규;송종걸
    • 한국지진공학회논문집
    • /
    • 제20권5호
    • /
    • pp.311-318
    • /
    • 2016
  • The lead-rubber bearing (LRB) dissipates seismic energy through plastic deformation of lead core. Under large-displacement cyclic motion, the temperature increases in the lead core. The shear strength of a lead-rubber bearing is reduced due to the heating effect of the lead core. In this study, the seismic responses such as displacement increasing, shear strength and vertical stiffness degradations of LRB due to the heating effect are evaluated for design basis earthquake (DBE) and beyond design basis earthquake (150% DBE, 167% DBE, 200% DBE).

Investigations on the bearing strength of stainless steel bolted plates under in-plane tension

  • Kiymaz, G.
    • Steel and Composite Structures
    • /
    • 제9권2호
    • /
    • pp.173-189
    • /
    • 2009
  • This paper presents a study on the behavior and design of bolted stainless steel plates under in-plane tension. Using an experimentally validated finite element (FE) program strength of stainless steel bolted plates under tension is examined with an emphasis on plate bearing mode of failure. A numerical parametric study was carried out which includes examining the behavior of stainless steel plate models with various proportions, bolt locations and in two different material grades. The models were designed to fail particularly in bolt tear-out and material piling-up modes. In the numerical simulation of the models, non-linear stress-strain material behavior of stainless steel was considered by using expressions which represent the full range of strains up to the ultimate tensile strain. Using the results of the parametric study, the effect of variations in bolt positions, such as end and edge distance and bolt pitch distance on bearing resistance of stainless steel bolted plates under in-plane tension has been investigated. Finally, the results obtained are critically examined using design estimations of the currently available international design guidance.

3차원 유한요소해석에 의한 얕은 기초의 지지력 특성 (Bearing Capacity Characteristics of Shallow Foundation by Three Dimension FEM)

  • 박춘식;김종환
    • 한국지반공학회논문집
    • /
    • 제35권3호
    • /
    • pp.17-24
    • /
    • 2019
  • 본 연구는 지반 위 얕은 기초의 지지력에 대한 특성을 파악하기 위하여 지반 조건, 기초 크기, 기초 형상 등의 다양한 조건에 대하여 3차원 유한요소해석을 수행하여 기존의 지지력 이론과 비교 검토하였다. 유한요소해석 결과 극한지지력은 기초크기에 따라 지지력이 거듭제곱이나 로그 식으로 차츰 수렴하였고, 지반강도가 증가할수록 지지력 증가가 커지지 않는 직선적인 변화를 보였다. 기존 지지력 이론과 비교한 결과 순수모래는 지지력 비($q_{FEA}/q_{theory}$)가 Terzaghi식의 결과와 가장 유사하였다. 순수점토는 약 0.4~0.6, 일반토사는 0.3~1.3 정도로 산정되었고, 지반강도가 증가할수록 지지력 비가 감소하면서 1.0 이하로 나타났다. 기초 크기에 따른 지지력을 1.0m 기초의 지지력으로 정규화시킨 지지력 비($q_u/q_{u(1.0)}$)는 순수모래에서 ${\phi}=25^{\circ}$, $30^{\circ}$, $35^{\circ}$일 때 이론식의 35%, 15%, 5% 정도로 산정되었고, 순수점토는 크기 효과가 없었으며, 일반토사는 지반강도가 작은 경우에 순수모래의 이론식에 대해 약 10% 이하로 나타났다. 지반강도 증가에 따른 지지력 비는 내부마찰각의 영향이 큰 것으로 나타났다. 기초형상별 지지력 비에 따른 형상계수는 기초형상에 따라 다르게 나타났고, 원형기초는 1.5, 정사각형 기초는 1.3, 직사각형 기초와 연속 기초는 1.1~1.0의 형상계수를 나타내었다.

C-Sphere Strength-Size Scaling in a Bearing-Grade Silicon Nitride

  • Wereszczak, Andrew A.;Kirkland, Timothy P.;Jadaan, Osama M.;Strong, Kevin T.;Champoux, Gregory J.
    • 한국세라믹학회지
    • /
    • 제45권9호
    • /
    • pp.507-511
    • /
    • 2008
  • A "C-sphere" specimen geometry was used to determine the failure strength distributions of a commercially-available bearing-grade silicon nitride ($Si_3N_4$) with ball diameters of 12.7 and 25.4 mm. Strengths for both diameters were determined using the combination of failure load, C-sphere geometry, and finite element analysis and fitted using two-parameter Weibull distributions. Effective areas of both diameters were estimated as a function of Weibull modulus and used to explore whether the strength distributions predictably scaled between each size. They did not. That statistical observation suggested that the same flaw type did not limit the strength of both ball diameters indicating a lack of material homogeneity between the two sizes. Optical fractography confirmed that. It showed there were two distinct strength-limiting flaw types common to both ball diameters, that one flaw type was always associated with lower strength specimens, and that a significantly higher fraction of the 25.4-mm-diameter C-sphere specimens failed from it. Predictable strength-size-scaling would therefore not result as a consequence of this because these flaw types were not homogenously distributed and sampled in both C-sphere geometries.

지압각 감소이론을 이용한 높은마디면적 철근의 부착강도 해석 (Bond Strength Analysis of High Relative Rib Area Bars Using Decreasing Bearing Angle Theory)

  • 양승열;서동민;박영수;홍건호;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.185-188
    • /
    • 2005
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond strength of ribbed reinforcing bars tends to split concrete cover, by wedging action, or shear the concrete in front of the ribs. In this study, using a reducing bearing angle theory, bond strengths of beam end specimen are predicted. Values of bond strength obtained using the analytical model are in good agreement with the bond test results. The analytical model provides insight into bond mechanism and the effects of bearing angle on the bond strength of deformed bars to concrete.

  • PDF

PC계 유동화제가 고강도 그라우트에 유동성 및 강도에 미치는 영향 (The Effect of PC-Based SP on Rheology and Strength of High Strength Grout)

  • 김범휘;이종구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.148-149
    • /
    • 2022
  • The use of high-strength grout applied for facility foundations and bridges has recently been expanding in offshore wind farm. Wind farm in offshore require bearing capacity for horizontal loads such as wind, waves, and earthquakes. In order to improve the bearing force of the base part, sufficient fluidity and a certain strength should be ensured so that the high-strength grout is densely charged in the narrow space of the connection part. Therefore, in this study, changes in fluidity and strength according to the ratio of PC-based superplasticizer mixed in high-strength grout were measured. As a result, as the ratio of the superplasticizer increased, fluidity increased and strength decreased. However, the strength did not decrease when the ratio of superplasticizer was above a 0.005. Therefore, it was confirmed that the fluidity change was remarkable when a 0.005 ratio of PC-based superplasticizer were added.

  • PDF

The Steel Coupling Beam-Wall Connections Strength

  • 박완신;윤현도
    • 콘크리트학회논문집
    • /
    • 제18권1호
    • /
    • pp.135-145
    • /
    • 2006
  • In high multistory reinforced concrete buildings, coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic effects. Coupled shear walls are usually built over the whole height of the building and re laid out either as a series of walls coupled by beams and/or slabs or a central core structure with openings to accommodate doors, elevators walls, windows and corridors. A number of recent studies have focused on examining the seismic response of concrete, steel, and composite coupling beams. However, since no specific equations are available for computing the bearing strength of steel coupling beam-wall connections, it is necessary to develop such strength equations. There were carried out analytical and experimental studies to develop the strength equations of steel coupling beam-connections. Experiments were conducted to determine the factors influencing the bearing strength of the steel coupling beam-wall connection. The results of the proposed equations were in good agreement with both test results and other test data from the literature. Finally, this paper provides background for design guidelines that include a design model to calculate the bearing strength of steel coupling beam-wall connections.